Records from 1995 to 2008. Most recent: inspection, 9 December 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
9 December 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3368363
17 September 2008
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3317588
5 February 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3142384
8 March 2007
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2884061
6 February 2006
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2578900
3 December 2004
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2252941
29 November 2004
Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2250341
1 April 2004
Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2035364
19 September 2003
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1908658
20 February 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1747738
12 November 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 295452
10 October 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 284269
2 November 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 434259
23 June 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 429929
27 January 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 424839
26 January 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 412105
21 August 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 381937
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 17 September 2008
Resolved
Oil containment at bunker station is cracked and will not retain oil. Containment must be repaired/replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 December 2008
Resolution: Received class report from Russian Maritime Register of Shipping, satisfying requirement.
Engineering › Fuel Oil Service System › Valve
Issued 17 September 2008
Resolved
Line for remote fuel shut-off valve for emergency generator fuel tank is broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 December 2008
Resolution: Received class report from Russian Maritime Register of Shipping, satisfying requirement.
Deck/Cargo › Cargo Refrigeration › General
Issued 17 September 2008
Resolved
Ventilation cover for reefer plant is wasted. Cover must be replaced/repaired to ensure watertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 December 2008
Resolution: Received class report from Russian Maritime Register of Shipping, satisfying requirement.
Engineering › Fuel Oil Service System › Pump
Issued 1 April 2004
Resolved
Noted portable ventilation fo main engine room fuel pump. Flag rep to attest to condition of pump and reason for overheating.SOLAS60/II LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 1 April 2004
Resolved 29 November 2004
Resolution: 06MAY2004 Class Society report has verified that fuel oil pump has been tested, and is in good condition.
Lifesaving › Lifeboat › Hull
Issued 1 April 2004
Resolved
Both Stbd and port life boat hulls in state of serious disrepair. Stbd hull has definate holes/failing patches around davit cradle shoes . Port lifeboat hull has extensive bubling, hull apears to be compromised. SOLAS60/ III. Flag state to attest to seaworthiness of both lifeboats. LEGACY COMPONENT DESC: Hull
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2004
Resolution: RMRS Class report by Sueveyor V. Utrobin attesting to both Stbd and Port Lifeboats being repaired and seaworthy.
Lifesaving › Lifebuoys
Issued 1 April 2004
Resolved
Lifebuoy light port side adjacent to EDG inoperable LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 1 April 2004
Resolution: new batt. install
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 1 April 2004
Resolved
Infirmary room has inoperable toilet and sink. ILO 147 LEGACY COMPONENT DESC: Hospital Space
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2004
Resolution: RMRS Class report by Surveyor V. Utrobin attesting to Infirmary having operable toilet and sink.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 1 April 2004
Resolved
Out of seven toilets checked on board four were not operable. ILO 147 LEGACY COMPONENT DESC: Toilet
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2004
Resolution: RMRS Class report by Surveyor V. Utrobin attesting to all toilet on board being operable.
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 April 2004
Resolved
base of main seawater pump #2 severly wasted. repair prior to next US port. Solas60/1/11 LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2004
Engineering › Sea-water System (primary cooling) › Pump
Issued 1 April 2004
Resolved
Base of seawater pump #2 severly wasted. Solas 60/1/11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2004
Resolved 29 November 2004
Resolution: Corroded foundation supports replaced to the satisfaction of the Coast Guard Marine Inspector. Class Society Report also verifies this.
Fire Fighting › Fire Pumps
Issued 20 February 2003
Resolved
VESSEL TO REPLACE GLAND SEALS ON MAIN FIRE PUMPS LEGACY COMPONENT DESC: Gland Sealing
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 19 September 2003
Resolution: RMRS Class report by surveyor M. Shcherbakov dated 4/11/03. The gaskets on both main fire pumps have been replaced, the main fire pumps have been tested under operation and found in fit condition.
Pollution Prevention/Response › Prevention Equipment
Issued 20 February 2003
Resolved
VESSEL TO PROVIDE 1BBL CONTAINMENT AROUND BUNKERING MANIFOLDS. LEGACY COMPONENT DESC: Fixed Containment
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 19 September 2003
Resolution: RMRS class report by surveyor M. Shcherbakov. The casings around bunkering manifold have been done.
Documentation › Certificates/Documents
Issued 20 February 2003
Resolved
VESSEL TO PROVIDE VALID MINIMUM SAFE MANNING DOCUMENT. LEGACY COMPONENT DESC: Minimum Safe Manning Document
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2003
Resolution: Rcvd interim safe manning document from Panama via fax.
Personnel › Certificates/Documents/Licenses
Issued 20 February 2003
Resolved
VESSEL TO PROVIDE STCW FLAG STATE ENDORSEMENT FOR ONE AB. LEGACY COMPONENT DESC: STCW Endorsement
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2003
Resolution: Rcvd copy from Panama via fax
Construction/Loadline
Issued 10 October 2000
Resolved
Repair as orginal hatch from steering gear room to aft weather deck. Base of hatch has holes which prevent hatch from being weather or water tight._x001C_ ILLC 66 I/18
Condition: Unknown
Due 13 November 2001
Resolved 13 November 2001
Lifesaving
Issued 2 November 1999
Resolved
LIFEBOAT ON STARBOARD SIDE WAS LOWERED WITH A 3/4 TO 1 DEGREE LIST TO PORT.AT FIRST,STBD LIFEBOAT WOULD NOT LOWER WHEN VESSEL HAD LIST TO PORT OF 1.5.CLASS SOCIETY IS TO ATTEST TO SATISFACTORY LOWERING OF STBD LIFEBOAT WITH ALIST TO PORT OF 1.5-15 DEGREE PER SOLAS 60 III/36, IN EITHER DIRECTION.
Condition: Unknown
Due 30 November 2000
Resolved 30 November 2000
Lifesaving
Issued 23 June 1999
Resolved
LIFEBOAT ON STARBOARD SIDE WAS LOWERED WITH A 3/4 TO 1 DEGREE LIST TO PORT.AT FIRST,STBD LIFEBOAT WOULD NOT LOWER WHEN VESSEL HAD LIST TO PORT OF 1.5.CLASS SOCIETY IS TO ATTEST TO SATISFACTORY LOWERING OF STBD LIFBOAT WITH A LIST TO PORT OF 1.5-15 DEGREE PER SOLAS 60 III/36,IN EITHER DIRECTION.
Condition: Unknown
Due 8 November 1999
Resolved 8 November 1999
Lifesaving
Issued 27 January 1999
Resolved
REPAIR OR REPLACE LIMIT SWITCHES ON PORT & STARBOARD LIFE BOAT DAVITS._x001C_ SOLAS 74 (AMENDED) III/48.2.5
Condition: Unknown
Due 23 June 1999
Resolved 23 June 1999
Electrical
Issued 26 January 1998
Resolved
Passageway light outside crew cabin #247 missing protective cover and fluorescent light interior cover, exposing all wiring inside the fixture. Required to repair/renew prior to return to U.S. Waters. Chief Engineer made immediate repair prior to departure of USCG Boarding Team.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Navigation
Issued 26 January 1998
Resolved
Vessel masthead, including lignts, were broken off during a storm. Vessel does not display proper configuration and the section of broken masthead isstrapped to the remaining support. Required to repair prior to departure and provide Class report attesting to the acceptance of the repairs.
Condition: Unknown
Due 28 January 1999
Resolved 28 January 1999
Documentation
Issued 26 January 1998
Resolved
Vessel officers did not have Flag State (PN) STCW endorsements on their previous Flag State licenses (UP). Required officers to correct deficiencyprior to arrival at next U.S. Port. Further research found Panama accepts Ukranian STCW standards and their endorsements.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Accommodation/Occupational Safety
Issued 21 August 1995
Resolved
PROVIDE PROPER MANUFACTURING PLATE TO BE ATTACHED TO THE MSD._x001C_ _x001C_ _x001C_ 33 CFR 159.7 (b) (1)
Condition: Unknown
Due 27 January 1998
Resolved 27 January 1998
Fire Fighting
Issued 21 August 1995
Resolved
PRIOR TO DEPARTING PORT OF HOUSTON, REPLACE ALL LEAKING FIREHOSES ON DECK_x001C_ AND IN THE ENGINE ROOM WITH NEW OR RENEWED FIREHOSES._x001C_ _x001C_ SOLLAS II-2/4.7
Condition: Unknown
Due 22 August 1995
Resolved 24 August 1995
Electrical
Issued 21 August 1995
Resolved
REPAIR EXPLOSIVE PROOF LIGHTING LOCATED IN PAINT LOCKER.
Condition: Unknown
Due 22 August 1995
Resolved 24 August 1995
Fire Fighting
Issued 21 August 1995
Resolved
PRIOR TO DEPARTING PORT OF HOUSTON, DEMONSTRATE OPERATION OF EMERGENCY FIREFIGHTING PUMP TO THE SATISFACTION OF LOCAL U.S. COASTGUARD OIMC_x001C_ _x001C_ SOLAS II-2/4
Condition: Unknown
Due 22 August 1995
Resolved 24 August 1995
Lifesaving
Issued 21 August 1995
Resolved
PROVIDE LOCAL U.S. COASTGUARD OCMI WITH COPY OF LIFERAFT SERVICING AS SOON_x001C_AS LIFERAFTS RETURNED FROM FIRE PROTECTION.
Condition: Unknown
Due 22 August 1995
Resolved 24 August 1995
Fire Fighting
Issued 21 August 1995
Resolved
ENSURE FIRE DRILLS ARE PROPERLY RECORDED IN SHIP'S LOG BOOK NO RECORD OF_x001C_ DRILLS._x001C_ _x001C_ SOLAS III 18/5
Condition: Unknown
Due 27 January 1998
Resolved 27 January 1998
Lifesaving
Issued 21 August 1995
Resolved
ENSURE INSPECTION OF LIFE SAVING APPLIANCES ARE PROPERLY RECORDED IN LOG_x001C_ BOOK._x001C_ _x001C_ SOLAS III 19/7
Condition: Unknown
Due 27 January 1998
Resolved 27 January 1998
Lifesaving
Issued 21 August 1995
Resolved
PROVIDE THE PROPER REFLECTIVE TAPE MATERIAL ON ALL LIFEBUOYS._x001C_ _x001C_ _x001C_ SOLAS III 30.2.7
Condition: Unknown
Due 27 January 1998
Resolved 27 January 1998
Accommodation/Occupational Safety
Issued 21 August 1995
Resolved
REPAIR THE SEWAGE (MSD) CIRCULATION PIPE LOCATED ON TOPSIDE OF MSD AND_x001C_ REPAIR ALL LEAKING FLANGES ON THE MSD._x001C_ _x001C_ 33 CFR 159
Condition: Unknown
Due 27 January 1998
Resolved 27 January 1998