QUARRY BAY is a 1988 freight ship. The Coast Guard has recorded 8 inspections since 1995, most recently in March 1998, along with 24 deficiencies and 1 operational control.

Records from 1995 to 1998. Most recent: inspection, 16 March 1998.

Built
1988
Last inspected
16 March 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8302260 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
419451
Flag
HONG KONG
—
Maury page id
psix-419451

Inspections, by type

…with no type recorded8
Years with a record 4 calendar years (1995–1998)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6166 - Regulatory (Subpart C or D), Net Ton
11572 - Regulatory (Subpart C or D), Gross Ton
13891 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 8

16 March 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 413588
20 December 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 411100
22 May 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 757168
15 May 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 208283
2 December 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 398074
25 November 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 397872
29 August 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 646207
10 August 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 381492

Deficiency record · 24

Accommodation/Occupational Safety
Issued 20 December 1997 Resolved
PROVIDE U.S.C.G. APPROVAL DATA FOR VESSEL'S MARINE SANITATIOIN DEVICE. VESSEL SHALL NOT DISCHAGE TREATED SEWAGE WITH-IN 3 NAUTICAL MILES OF U.S. UNTIL APPROVAL OF MSD IS DETERMINED.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Navigation
Issued 20 December 1997 Resolved
TRANSLATE EMERGENCY STEERING INSTRUCTIONS AND BLOCK DIAGRAM INTO LANGUAGE UNDERSTOOD BY THE CREW.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Documentation
Issued 20 December 1997 Resolved
PROVIDE CLASS ACCEPTANCE REPORT FOR FIRE PUMP REPAIRS PRIOR TO NEXT U.S. PORT CALL.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Fire Fighting
Issued 20 December 1997 Resolved
PROVIDE SECOND PUMP WITH ADEQUATE PRESSURE TO SUPPLY VESSSEL'S FIRE MAIN SYSTEM.
Condition: Unknown
Due 23 December 1997
Resolved 23 December 1997
Electrical
Issued 20 December 1997 Resolved
REINSTALL 3 COVERS ON ELECTRICAL PANELS LOCATED IN THE FORWARD MAIN DECK ELECTRICAL CONTROL ROOM.
Condition: Unknown
Due 23 December 1997
Resolved 23 December 1997
Fire Fighting
Issued 20 December 1997 Resolved
REPAIR HANDLE TO ESCAPE DOOR #5 LOCATED IN THE ENGINEROOM.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Fire Fighting
Issued 20 December 1997 Resolved
REPAIR AND PROVE PROPER OPERATION THE THE PRIMARY FIRE PUMP.
Condition: Unknown
Due 23 December 1997
Resolved 23 December 1997
Fire Fighting
Issued 20 December 1997 Resolved
PROVIDE FIRE NOZZLE AT ENGINEROOM FIRE STATION PORT SIDE LOWER LEVEL AFT.
Condition: Unknown
Due 23 December 1997
Resolved 23 December 1997
Navigation
Issued 20 December 1997 Resolved
PROVE PROPER OPERATION OF THE STEERING SYSTEM BY LOCAL CONTROL IN THE STEERING COMPARTMENT.
Condition: Unknown
Due 23 December 1997
Resolved 23 December 1997
Engineering
Issued 20 December 1997 Resolved
UPDATE OIL TRANSFER PROCEDURES AS OUTLINED IN 33 CFR 155.750.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Documentation
Issued 25 November 1996 Resolved
Pollution placards missing.(33 CFR 155.450)
Condition: Unknown
Due 20 February 1997
Resolved 20 February 1997
Fire Fighting
Issued 25 November 1996 Resolved
Emergency fire pump unable to generate water pressure. Prove proper operation.(SOLAS 74 (AMENDED) REG 4)
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Lifesaving
Issued 10 August 1995 Resolved
PROVIDE ONBOARD OPERATING INSTRUCTIONS FOR PORT AND STBD LIFEBOATS IAW SOLAS 74 AMENDED III/9
Condition: Unknown
Due 12 August 1995
Resolved 13 August 1995
Documentation
Issued 10 August 1995 Resolved
PROVIDE UP TO DATE LETTERS FOR THE [name withheld] OFFICER._x001C_ STCW 78 II/4,3/4
Condition: Unknown
Due 12 August 1995
Resolved 14 August 1995
Navigation
Issued 10 August 1995 Resolved
Provide on-board Manuvering Fact Sheet with Warning Statement.
Condition: Unknown
Due 11 September 1995
Resolved 13 August 1995
Documentation
Issued 10 August 1995 Resolved
Provide on board Oil Transfer Procedures.
Condition: Unknown
Due 11 September 1995
Resolved 13 August 1995
Documentation
Issued 10 August 1995 Resolved
COMPLETE ALL LOG BOOK ENTRIES AS REQUIRED BY SOLAS 74 AMENDED III/19.6.1, 19.6.2, 19.6.3, 19.7, 18.4, 18.5, AND AS REQUIRED BY SOLAS 74 AMENDED V/19.2.
Condition: Unknown
Due 11 September 1995
Resolved 25 January 1996
Fire Fighting
Issued 10 August 1995 Resolved
PROVIDE FIRE HOSE AT EACH FIRE STATION THROUGHOUT VESSEL IN GOOD CONDITION AND AVAILABLE FOR IMMEDIATE USE, SOLAS 74 AMENDED II-2/21.
Condition: Unknown
Due 14 August 1995
Resolved 13 August 1995
Fire Fighting
Issued 10 August 1995 Resolved
PROVIDE ON BOARD INSTRUCTIONS FOR ON BOARD MAINTENANCE OF LIFESAVING APPLIANCES SOLAS 74 AMENDED III 19.3/52.
Condition: Unknown
Due 13 August 1995
Resolved 13 August 1995
Documentation
Issued 10 August 1995 Resolved
PROVIDE ON BOARD AN APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 August 1995
Resolved 29 August 1995
Lifesaving
Issued 10 August 1995 Resolved
REPAIR/RENEW BOAT DAVIT LIMIT SWITCH STARBOARD SIDE AFT. _x001C_ SOLAS 74 AMENEDED III/41.8
Condition: Unknown
Due 13 August 1995
Resolved 13 August 1995
Navigation
Issued 10 August 1995 Resolved
PROVIDE UP TO DATE CHARTS AND MATERIALS PUBLICATIONS FOR INTENDED VOYAGE, SOLAS 74 AMENDED V/20.
Condition: Unknown
Due 14 August 1995
Resolved 17 August 1995
Navigation
Issued 10 August 1995 Resolved
PROVE OPERATION OF STEERING GEAR POWER FAILURE AUDIBLE AND VISUAL ALARM ON THE NAVIGATION BRIDGE, SOLAS 74 AMENDED II-2/29.5.
Condition: Unknown
Due 13 August 1995
Resolved 13 August 1995
Fire Fighting
Issued 10 August 1995 Resolved
PROVIDE ONBOARD INSTRUCTIONS FOR MAINTENANCE AND OPERATIONS OF ALL INSTALLATIONS/EQUIPMENT FOR FIGHTING AND CONTAINMENT OF FIRE IN ACCORDANCE WITH SOLAS 74 (AMENDED) II-2/20.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996

Ownership record