MAURY USCG vessel records Sign in
← All vessels

SAN PAULO

SAN PAULO is a 1986 freight ship. The Coast Guard has recorded 32 inspections since 1995, most recently in September 2010, along with 24 deficiencies and 2 operational controls.

Records from 1995 to 2010. Most recent: inspection, 13 September 2010.

Built
1986
Last inspected
13 September 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8620129 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
419549
Flag
BELIZE
—
Maury page id
psix-419549

Inspections, by type

…with no type recorded18
Years with a record 16 calendar years (1995–2010)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it12410 - Convention (Subpart B), Gross Ton
4837 - Convention (Subpart B), Net Ton
19111 - Displacement, Ton
11862 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

13 September 2010 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3844967
13 September 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3848937
12 September 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3845391
27 February 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3424281
25 February 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3423939
24 February 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3423055
13 November 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3358222
4 March 2008 PII Safety Exam · Deficiency Check · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3156760
21 September 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3063114
20 September 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3062484
10 September 2007 PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3042275
9 May 2006 ISPS II Exam · PII Safety Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2645011
18 March 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2311307
5 January 2005 ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2269154
7 December 2004 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2255301
5 February 2004 Re-Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2000843
18 July 2003 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1849817
8 May 2003 Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1788569
25 February 2002 Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1489014
11 June 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 290640
19 September 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 282285
14 June 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 105151
22 November 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 434992
2 November 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 422110
24 June 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 416693
20 April 1998 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 205363
20 April 1998 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 761101
27 January 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 442602
20 November 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 507029
17 July 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 494405
21 October 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 396250
11 July 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 380211

Deficiency record · 24

Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 4 March 2008 Resolved
The vessel has an outstanding deficiency from 10SEP07 see activity #3042275. The vessel was prohibited from bunkering in U.S waters. The PSCO found the vessel violated this requirement. Vessel was required to submit a Letter of Undertaking in the amount of $32,500.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2008
Resolved 5 March 2008
Resolution: The responsible company provided the U.S.C.G with a Letter of Undertaking in the amount of $ 32,500.00. This satisfied to the above requirement.
Engineering › Steering Gear System › Piping
Issued 20 September 2007 Resolved
A tubing line on the discharge piping of the no.2 steering pump broke causing a steering power failure.
Action required: 705 - Other - as specified
Due 20 September 2007
Resolved 21 September 2007
Resolution: Received class report from Bureau Veritas satisfying requirement
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 10 September 2007 Resolved
Vessel master or chief engineer could not provide proof of hydrostatic test within the last year. Hydrostatic test of fuel and lube oil piping must be completed prior to conducting bunkering operations within US waters.
Action required: 703 - Prior to bunkering operations
Due 15 September 2007
Resolved 4 March 2008
Resolution: Received, reviewed and accepted proper documentation from the vessel Master attesting to a Hydrostatic pressure test of the bunkering lines in accordance with 33 CFR 156.170.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 March 2005 Resolved
Issued deficiency on light fixtures. Various light fixtures on vessel found to be not working and not have light covers which poses a safety hazard to crew. Areas where observed were: the engine control room, Aft Steering, Provision Stores, Aft deck by pool, Crane #4 control room, FWD Bosun Stores. SOLAS 74A II-1/45.1 / ILO 134 Article 43a,d
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2005
Resolved 8 May 2006
Resolution: Inspected light fixtures. All fixtures in good working order and have light covers. J [name withheld], LTJG
Deck/Cargo › Holds/Tanks
Issued 5 February 2004 Resolved
FORWARD CARGO HATCH TO BOS'N HOLE MISSING FWD. DOG AND NOT FORMING WATER/WEATHER TIGHT SEAL. LL 66 ANEX 1. LEGACY COMPONENT DESC: Hatch
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 March 2004
Resolved 1 April 2004
Resolution: Rcv''''d Class Report (BV) dated 30-Mar-04. Forward dog on hatch replaced and rubber seal renewed. hatch tested and found watertight.
Electrical › Lighting (service)
Issued 5 February 2004 Resolved
LIGHT FIXTURES ON FOCSLE AND PORT FWD. MAIN DECK FOUND BROKEN AND WASTED. SOLAS 74 II-1 45. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 March 2004
Resolved 1 April 2004
Resolution: Rcv''d Class Report (BV) dated 30-Mar-04. Forward lights renewed/replaced and in good condition.
Accommodation/Occupational Safety › Occupational Safety
Issued 8 May 2003 Resolved
REMOVE OLD BANK OF BATTERIES FROM BATTERY ROOM AND DISPOSE OF PROPERLY. SOLAS 74(A) IV/REG 13 LEGACY COMPONENT DESC: BATTERY ROOM
Due 8 June 2003
Resolved 18 July 2003
Resolution: CLEARED DEF
Engineering › Lubricating Oil Storage/Transfer System
Issued 8 May 2003 Resolved
REMOVE RUBBER HOSES BEING USED IN OIL TRANSER SYSTEM (ENGINE ROOM) / MAIN ENG LUBRICATING. SOLAS 74(A) II-1/REG 27 LEGACY COMPONENT DESC: Hose
Due 8 June 2003
Resolved 18 July 2003
Resolution: CLEARED DEF
Lifesaving › Lifeboat Equipment
Issued 8 May 2003 Resolved
REPLACE MISSING FOOD RATIONS: 37 PORT; 37 STBD; FOR A TOTAL OF 74 RATIONS TOTALING NOT LESS THAN 10,000 JS EACH. FAX RECEIPT TO ATENDING MARINE INSPECTOR PRIOR TO DEP PORT OF BALTIMORE. SOLAS 74(A) III-11 LEGACY COMPONENT DESC: Food Ration
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2003
Resolved 13 May 2003
Resolution: RECEIVED FAXED RECEIPT FOR RATIONS.
Electrical › Electrical Distribution System (service)
Issued 25 February 2002 Resolved
PROVIDE NON CONDUCTIVE MATTING THROUGHOUT ENGINE ROOM AT ELECTRICAL PANELS. CLASS TO ADDRESS - PROVIDE REPORT TO USCG. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2002
Resolved 8 May 2003
Resolution: Found to be corrected.
Fire Fighting
Issued 25 February 2002 Resolved
FIRE DOOR #460 LOCAL OPERATION NOT WORKING PROPERLY - AND UPON RELEASE, DOOR DOES NOT SEAL SHUT. LEGACY COMPONENT DESC: FIRE DOOR
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2002
Resolved 25 February 2002
Resolution: BEFORE COMPLETION OF THE EXAM, DOOR WAS MAITENANCED BY CREW AND USCG WITNESSED SAT OEPRATION OF LOCAL RELEASE AND SATISFACTORY SEAL OF DOOR EDGE.
Pollution Prevention/Response › Prevention Equipment
Issued 25 February 2002 Resolved
OWS CONTENT METER AND ALARM NEED TO BE CALIBRATED TO ACTIVATE AUTOMATICALLY AT 15 PPM NOT 23 PPM SHUT DOWN OF PUMP OPERATIONAL BUT FIVE SECOND DELAY EXISTS IN ACTUAL SHUTDOWN OF PUMPING THROUGH SYSTEM. CLASS TO ADDRESS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2002
Resolved 23 May 2003
Resolution: Rcv''d BV class report from agent in JACMS. Report dated 27Feb02 states that the OWS was tested and found to be operating satisfactory.
Engineering › Sea-water System (primary cooling)
Issued 25 February 2002 Resolved
SEAWATER OVERBOARD VALVE LEAKING IN ENGINE ROOM AT TANK TOP DECK, AFT, STARBOARD SIDE OF ENGINE ROOM. CLASS TO ADDRESS - PROVIDE REPORT TO USCG FOR REVIEW. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2002
Resolved 23 May 2003
Resolution: Rcv''d BV class report dated 27Feb02 stating item was dealt with to the satisfaction of attending class surveyor.
Electrical › Electrical Distribution System (service)
Issued 25 February 2002 Resolved
EXPOSED WIRING OUTSIDE MESS DECK, PORTSIDE, MAIN DECK. CLASS TO ADDRESS - PROVIDE REPORT TO USCG. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2002
Resolved 8 May 2003
Resolution: Found to be corrected.
Construction/Loadline › Hull
Issued 25 February 2002 Resolved
WASTAGE AT EMERGENCY FIRE PUMP BULK HEADS AND DECK PLATES. CLASS TO ADDRESS - PROVIDE REPORT TO USCG FOR REVIEW. LEGACY COMPONENT DESC: Stiffener
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2002
Resolved 8 May 2003
Resolution: Found to be corrected.
Stability › Watertight Integrity
Issued 25 February 2002 Resolved
LABEL POWER OPERATED WATERTIGHT DOORS IN ENGINE ROOM WITH OPERATING INSTRUCTIONS IN LANGUAGE OF THE CREW. CLASS TO ADDRESS.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2002
Resolved 8 May 2003
Resolution: Found to be corrected.
Operations/Management
Issued 25 February 2002 Resolved
ADDRESS OUTSTANDING CONDITIONS OF CLASS NO LATER THAN 31 JUL 02. 1)REPAIR SHELL PLATE INSET IN WAY OF TANK NO. 47, PORT QUARTER 2) REPLACE RUDDER PINTLE TO RETAIN "ICE" CLASS ON CERTIFICATION
Action required: 705 - Other - as specified
Due 31 July 2002
Resolved 23 May 2003
Resolution: Rcv''d BV class report dated 11Nov02, issues were corrected at drydock.
Lifesaving › Lifeboat
Issued 25 February 2002 Resolved
PROVIDE CLASS STATEMENT OF FACT THAT STARBOARD LIFE BOAT MOTOR IS OPERATIONAL AND THAT ANY REPAIRS NECCESSARY HAVE BEEN CARRIED OUT. LEGACY COMPONENT DESC: Propulsion Starting System
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2002
Resolved 25 February 2002
Resolution: RECEIVED CLASS STATEMENT OF FACT ATTESTING TO INSTALLATION ON NEW START BATTERY AND PROPER OPERATION OF THE LIFEBOAT ENGINE.
Fire Fighting
Issued 19 September 2000 Resolved
Noted several vent dampners in engine room space to be damaged, preventing quick closure. SOLAS 74/78 II-2/48.
Condition: Unknown
Due 30 October 2000
Resolved 15 November 2000
Navigation
Issued 19 September 2000 Resolved
During test of steering to clear NEWMS Def. 01 dtd 08JUN00 concerning the #1 steering pump, noted that #2 pump was also showing signs of wear. (Most likely bushings). SOLAS 74/78 II-1/29/2.1
Condition: Unknown
Due 30 October 2000
Resolved 15 November 2000
Construction/Loadline
Issued 24 June 1998 Resolved
RENEW AS ORIGINAL DETERIORATED BALLAST PIPING, MIDSHIP ON LOWER DECK OF ENGINE ROOM. SOLAS 74(AMENDED) I 11(a).
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Accommodation/Occupational Safety
Issued 24 June 1998 Resolved
RENEW AS ORIGINAL DETERIORATED SEWAGE TANK VENT AND PIPING. MARPOL 73/78 ANNEX IV REG. 3(1)(a)(i).
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Engineering
Issued 11 July 1995 Resolved
Flame screen on forward most vent, port side, aft of forcastle, is holed. Temporary repairs made. Vessel required to make permanent repairs before entering next U.S. Port
Condition: Unknown
Due 21 October 1996
Resolved 21 October 1996
Construction/Loadline
Issued 11 July 1995 Resolved
Metal Deck Grating alongside of each lifeboat wasted away, both port and starbord side. Grating at risk of colasping under load. Vessel required to make permanent repairt prior to entry into next U.S. Port.
Condition: Unknown
Due 21 October 1996
Resolved 21 October 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.