← All vessels
SAN PAULO
SAN PAULO is a 1986 freight ship. The Coast Guard has recorded 32 inspections since 1995, most recently in September 2010, along with 24 deficiencies and 2 operational controls.
Records from 1995 to 2010. Most recent: inspection, 13 September 2010.
- Built
- 1986
- Last inspected
- 13 September 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8620129 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V3WY2
419549
Flag
BELIZE
—
Maury page id
psix-419549
Inspections, by type
…with no type recorded18
Years with a record
16 calendar years (1995–2010)
The 32 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Documentation record
Tonnage as PSIX records it12410 - Convention (Subpart B), Gross Ton
4837 - Convention (Subpart B), Net Ton
19111 - Displacement, Ton
11862 - Dead Weight, Ton
4837 - Convention (Subpart B), Net Ton
19111 - Displacement, Ton
11862 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 32
13 September 2010
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3844967
13 September 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3848937
12 September 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3845391
27 February 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3424281
25 February 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3423939
24 February 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3423055
13 November 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3358222
4 March 2008
PII Safety Exam · Deficiency Check · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3156760
21 September 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3063114
20 September 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3062484
10 September 2007
PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3042275
9 May 2006
ISPS II Exam · PII Safety Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2645011
18 March 2005
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2311307
5 January 2005
ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2269154
7 December 2004
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2255301
5 February 2004
Re-Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2000843
18 July 2003
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1849817
8 May 2003
Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1788569
25 February 2002
Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1489014
11 June 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 290640
19 September 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 282285
14 June 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 105151
22 November 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 434992
2 November 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 422110
24 June 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 416693
20 April 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 205363
20 April 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 761101
27 January 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 442602
20 November 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 507029
17 July 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 494405
21 October 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 396250
11 July 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 380211
Deficiency record · 24
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 4 March 2008
Resolved
The vessel has an outstanding deficiency from 10SEP07 see activity #3042275. The vessel was prohibited from bunkering in U.S waters. The PSCO found the vessel violated this requirement. Vessel was required to submit a Letter of Undertaking in the amount of $32,500.
Engineering › Steering Gear System › Piping
Issued 20 September 2007
Resolved
A tubing line on the discharge piping of the no.2 steering pump broke causing a steering power failure.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 10 September 2007
Resolved
Vessel master or chief engineer could not provide proof of hydrostatic test within the last year. Hydrostatic test of fuel and lube oil piping must be completed prior to conducting bunkering operations within US waters.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 March 2005
Resolved
Issued deficiency on light fixtures. Various light fixtures on vessel found to be not working and not have light covers which poses a safety hazard to crew. Areas where observed were: the engine control room, Aft Steering, Provision Stores, Aft deck by pool, Crane #4 control room, FWD Bosun Stores. SOLAS 74A II-1/45.1 / ILO 134 Article 43a,d
Deck/Cargo › Holds/Tanks
Issued 5 February 2004
Resolved
FORWARD CARGO HATCH TO BOS'N HOLE MISSING FWD. DOG AND NOT FORMING WATER/WEATHER TIGHT SEAL. LL 66 ANEX 1. LEGACY COMPONENT DESC: Hatch
Electrical › Lighting (service)
Issued 5 February 2004
Resolved
LIGHT FIXTURES ON FOCSLE AND PORT FWD. MAIN DECK FOUND BROKEN AND WASTED. SOLAS 74 II-1 45. LEGACY COMPONENT DESC: Lighting Fixture
Accommodation/Occupational Safety › Occupational Safety
Issued 8 May 2003
Resolved
REMOVE OLD BANK OF BATTERIES FROM BATTERY ROOM AND DISPOSE OF PROPERLY.
SOLAS 74(A) IV/REG 13 LEGACY COMPONENT DESC: BATTERY ROOM
Engineering › Lubricating Oil Storage/Transfer System
Issued 8 May 2003
Resolved
REMOVE RUBBER HOSES BEING USED IN OIL TRANSER SYSTEM (ENGINE ROOM) / MAIN ENG LUBRICATING.
SOLAS 74(A) II-1/REG 27 LEGACY COMPONENT DESC: Hose
Lifesaving › Lifeboat Equipment
Issued 8 May 2003
Resolved
REPLACE MISSING FOOD RATIONS: 37 PORT; 37 STBD; FOR A TOTAL OF 74 RATIONS TOTALING NOT LESS THAN 10,000 JS EACH. FAX RECEIPT TO ATENDING MARINE INSPECTOR PRIOR TO DEP PORT OF BALTIMORE.
SOLAS 74(A) III-11 LEGACY COMPONENT DESC: Food Ration
Electrical › Electrical Distribution System (service)
Issued 25 February 2002
Resolved
PROVIDE NON CONDUCTIVE MATTING THROUGHOUT ENGINE ROOM AT ELECTRICAL PANELS. CLASS TO ADDRESS - PROVIDE REPORT TO USCG. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Fire Fighting
Issued 25 February 2002
Resolved
FIRE DOOR #460 LOCAL OPERATION NOT WORKING PROPERLY - AND UPON RELEASE, DOOR DOES NOT SEAL SHUT. LEGACY COMPONENT DESC: FIRE DOOR
Pollution Prevention/Response › Prevention Equipment
Issued 25 February 2002
Resolved
OWS CONTENT METER AND ALARM NEED TO BE CALIBRATED TO ACTIVATE AUTOMATICALLY AT 15 PPM NOT 23 PPM SHUT DOWN OF PUMP OPERATIONAL BUT FIVE SECOND DELAY EXISTS IN ACTUAL SHUTDOWN OF PUMPING THROUGH SYSTEM. CLASS TO ADDRESS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Engineering › Sea-water System (primary cooling)
Issued 25 February 2002
Resolved
SEAWATER OVERBOARD VALVE LEAKING IN ENGINE ROOM AT TANK TOP DECK, AFT, STARBOARD SIDE OF ENGINE ROOM. CLASS TO ADDRESS - PROVIDE REPORT TO USCG FOR REVIEW. LEGACY COMPONENT DESC: Valve
Electrical › Electrical Distribution System (service)
Issued 25 February 2002
Resolved
EXPOSED WIRING OUTSIDE MESS DECK, PORTSIDE, MAIN DECK. CLASS TO ADDRESS - PROVIDE REPORT TO USCG. LEGACY COMPONENT DESC: Wiring
Construction/Loadline › Hull
Issued 25 February 2002
Resolved
WASTAGE AT EMERGENCY FIRE PUMP BULK HEADS AND DECK PLATES. CLASS TO ADDRESS - PROVIDE REPORT TO USCG FOR REVIEW. LEGACY COMPONENT DESC: Stiffener
Stability › Watertight Integrity
Issued 25 February 2002
Resolved
LABEL POWER OPERATED WATERTIGHT DOORS IN ENGINE ROOM WITH OPERATING INSTRUCTIONS IN LANGUAGE OF THE CREW. CLASS TO ADDRESS.
Operations/Management
Issued 25 February 2002
Resolved
ADDRESS OUTSTANDING CONDITIONS OF CLASS NO LATER THAN 31 JUL 02.
1)REPAIR SHELL PLATE INSET IN WAY OF TANK NO. 47, PORT QUARTER
2) REPLACE RUDDER PINTLE TO RETAIN "ICE" CLASS ON CERTIFICATION
Lifesaving › Lifeboat
Issued 25 February 2002
Resolved
PROVIDE CLASS STATEMENT OF FACT THAT STARBOARD LIFE BOAT MOTOR IS OPERATIONAL AND THAT ANY REPAIRS NECCESSARY HAVE BEEN CARRIED OUT. LEGACY COMPONENT DESC: Propulsion Starting System
Fire Fighting
Issued 19 September 2000
Resolved
Noted several vent dampners in engine room space to be damaged, preventing quick closure. SOLAS 74/78 II-2/48.
Navigation
Issued 19 September 2000
Resolved
During test of steering to clear NEWMS Def. 01 dtd 08JUN00 concerning the #1 steering pump, noted that #2 pump was also showing signs of wear. (Most likely bushings). SOLAS 74/78 II-1/29/2.1
Construction/Loadline
Issued 24 June 1998
Resolved
RENEW AS ORIGINAL DETERIORATED BALLAST PIPING, MIDSHIP ON LOWER DECK OF ENGINE ROOM. SOLAS 74(AMENDED) I 11(a).
Accommodation/Occupational Safety
Issued 24 June 1998
Resolved
RENEW AS ORIGINAL DETERIORATED SEWAGE TANK VENT AND PIPING. MARPOL 73/78 ANNEX IV REG. 3(1)(a)(i).
Engineering
Issued 11 July 1995
Resolved
Flame screen on forward most vent, port side, aft of forcastle, is holed. Temporary repairs made. Vessel required to make permanent repairs before entering next U.S. Port
Construction/Loadline
Issued 11 July 1995
Resolved
Metal Deck Grating alongside of each lifeboat wasted away, both port and starbord side. Grating at risk of colasping under load. Vessel required to make permanent repairt prior to entry into next U.S. Port.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.