MAURY USCG vessel records Sign in
← All vessels

SCAN BULKER

SCAN BULKER is a 1994 freight ship. The Coast Guard has recorded 20 inspections since 1995, most recently in January 2012, along with 12 deficiencies and 5 operational controls.

Records from 1995 to 2012. Most recent: inspection, 3 January 2012.

Built
1994
Last inspected
3 January 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9105396 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
419557
Flag
PANAMA
—
Maury page id
psix-419557

Inspections, by type

…with no type recorded11
Years with a record 12 calendar years (1995–2012)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it16446 - Convention (Subpart B), Gross Ton
9409 - Convention (Subpart B), Net Ton
27308 - Dead Weight, Ton
33272 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

3 January 2012 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4217558
11 August 2011 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4112054
10 February 2010 ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3674909
28 October 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2809652
28 October 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2810428
22 October 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2808456
14 February 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2584961
13 February 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2584277
4 May 2005 ISPS III Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2349445
25 April 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2342608
7 February 2005 Random ISPS/MTSA/PSC
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2288272
28 January 2005 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2281370
18 February 2004 Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2008653
18 February 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2009290
24 May 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1800222
2 August 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 292166
3 March 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 425956
29 January 1998 Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 412320
9 August 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 406588
30 July 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 381121

Deficiency record · 12

Navigation › Piloting/Steering › US Coast Pilot
Issued 28 January 2005 Resolved
Provide a current copy of the US Coast Pilot. 33CFR 164 (33) To the satisfaction of the US Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2005
Resolution: Fax of receipt sent to USCG.
Fire Fighting › Nozzles › Condition
Issued 28 January 2005 Resolved
Test to the satisfaction of class all fire hose nozzles on vessel. SOLAS 74 amd II-2/4.8
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2005
Resolution: Class report attesting to the functionality of all fire nozzles onboard received via fax @ MSO Portland.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 28 January 2005 Resolved
Provide proof of the last external ISM audit. SOLAS 74 amd IX/6. Must be completed to the satisfaction of the US Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2005
Resolution: [name withheld] confered with NKK class representative to confirm that a satisfactory audit had taken place.
Documentation › Certificates/Documents › IOPP Certificate
Issued 28 January 2005 Resolved
Update the IOPP certificate to include the sludge settling tank. MARPOL 73/78 annex I/17. To the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2005
Engineering › Bilge Water Management System › Piping
Issued 28 January 2005 Resolved
Modify the piping arrangement for the bilge system to correspond with the piping diagram. The existing arrangement allows for pumping from the bilge pump through the OWS discharge valve bypassing the OWS. MARPOL 734/78 annex I/17. To the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2005
Resolution: NKK approved the cropping and welded blind flange in accordance with original bilge piping diagram to prevent pumping of bilge slops directly overboard. Class did not re-certify drawings as original line diagram installlation was not altered.
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 January 2005 Resolved
Install the fuel shutoff valve for the emergency generator fuel tank outside the space. SOLAS 74 amd II-2/15.2.5 To the satisfaction of class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 April 2005
Resolved 25 April 2005
Resolution: Externally located fuel shut-off valve installed on 600 liter EDG fuel oil tank, and functioning appropriately.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 28 January 2005 Resolved
Install permanent piping for the MSD flushing line. There is a fire hose connecting this system currently. SOLAS 74 amd I/II. To the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2005
Resolution: Soft fire hose jumper line replaced with welded schedule 40 equivalent pipe to original condition.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 January 2005 Resolved
Install non-slip surface around the steering gear machinery and controls. SOLAS 74 amd II-1/29.13.2 to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2005
Resolution: Wooden grating built around entire steering gear ram and rudder assembly. Well constructed.
Navigation › Collision/Grounding Avoidance
Issued 18 February 2004 Resolved
Vessel's secondary radar screen is malfunctioning. Radar seems to be functioning properly though the screen is flickering continously. Repairs to be completed prior to 1600 on 22 FEB2004. LEGACY COMPONENT DESC: Radar
Action required: 705 - Other - as specified
Due 22 February 2004
Resolved 19 February 2004
Resolution: Received satisfactory technician''s report on 19 FEB 2004, cleared deficiency.
Deck/Cargo
Issued 3 March 1999 Resolved
Repair or renew hydraulic hose to #1 port/aft hatch cover hydraulic ram where leaking. SOLAS 74 amd. I/II. Complete prior to next U.S. Port.
Condition: Unknown
Due 15 December 2000
Resolved 15 December 2000
Engineering
Issued 3 March 1999 Resolved
Repair main shaft at hull penetration where leaking oil. The oil is a slow drip into a bucket tied under the shaft in the engine room. _x001C_ SOLAS 74 amd. I/II Complete prior to next U.S. Port.
Condition: Unknown
Due 15 December 2000
Resolved 15 December 2000
Documentation
Issued 3 March 1999 Resolved
Provide Oil Transfer procedure prior to next U.S. port. 33 C.F.R. 155.720
Condition: Unknown
Due 15 December 2000
Resolved 15 December 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.