PAN AMERICAN CLIPPER

PAN AMERICAN CLIPPER is a 1937 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1983, most recently in November 2021, along with 65 deficiencies — 1 with no resolution recorded — and 2 operational controls.

Records from 1983 to 2021. Most recent: inspection, 15 November 2021.

Built
1937
Last inspected
15 November 2021
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE3857
Flag
UNITED STATES
367345180
Maury page id
psix-41956

Inspections, by type

…with no type recorded5
…past their stated due date1
Years with a record 34 calendar years (1983–2021)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.6 ft × 20.3 ft × 5.6 ft
Registered tonnagegross 53 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTOCHE BROTHERS BOAT BUILDERS · BILOXI, MS, UNITED STATES · built 1937
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portOCEAN SPRINGS, MS
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 30 September 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it53 - Regulatory (Subpart C or D), Gross Ton
46 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE3857MMSI 367345180 · active · compulsorily equipped · granted 15 March 2018, expires 26 March 2028
WA9300MMSI not assigned · expired · compulsorily equipped · granted 12 December 1997, cancelled 3 May 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 64

15 November 2021 Administrative Inspection · In-Service Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7351046
4 January 2021 COI Inspection · Administrative Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7119569
6 November 2019 Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6850885
6 November 2019 MTSA Verification · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6850893
16 January 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6611287
23 February 2018 DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6360629
4 January 2018 Examination of Repairs · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6332795
31 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6161957
22 February 2017 Administrative Inspection · DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6092942
25 May 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5886885
8 December 2015 Internal Structural Exam · DAPI Audit · Examination of Repairs · Hull Examination · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5777805
21 January 2011 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3928610
13 January 2011 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3910413
14 January 2010 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3659753
15 December 2009 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3632865
10 December 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3359234
19 November 2007 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3093350
1 November 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3085675
29 January 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2863607
9 January 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2852665
19 January 2006 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2535248
12 October 2005 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2502360
12 October 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2513065
24 May 2005 MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2366641
3 March 2005 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2302802
25 October 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2228185
8 March 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2020215
11 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963344
2 December 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1954864
15 October 2003 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1929083
12 December 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1719552
20 November 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1690104
11 December 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1391744
16 November 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1397783
5 April 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1061538
21 March 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 817682
19 January 2000 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1403038
7 January 1999 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 811236
10 December 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1429061
20 February 1998 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1431916
27 February 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1104369
7 January 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1113673
7 January 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1448846
14 July 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1089553
27 February 1996 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1078607
18 January 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1443657
28 December 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1438262
3 November 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1432847
9 May 1994 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1013927
19 February 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1148565
27 January 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1138703
20 May 1992 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1261882
13 May 1992 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1266644
30 October 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1245637
13 September 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1253148
4 June 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1009393
6 March 1990 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 985402
6 March 1989 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1209033
21 April 1988 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1343523
5 March 1987 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1017123
14 March 1986 Credit Drydock · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 999369
2 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 977945
29 February 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971350
16 February 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967503

Deficiency record · 65

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 December 2021 No resolution recorded
Repairs or alternations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval of the cognizant [name withheld] worklist items noted while conducting hull exam. Vessel is required to correct all worklist items and schedule an re-inspection prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2021 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 December 2019 Resolved
Identified rotted deck area under the starboard toilet. Vessel is to repair rotted deck under toilet.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2020
Resolved 8 January 2020
Resolution: The rotted deck area under the starboard toilet was cropped out and replaced with a pvc board with a fiberglass/polyester resin overlay. All sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 14 March 2018 Resolved
The delay bottle for the unit is not working, 30 second delay was discharging at 20 and 26 seconds. New assembly required by certified technician.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2018
Resolved 19 March 2018
Resolution: Received proof of repairs.
Engineering › Bilge Water Management System › Piping
Issued 21 March 2017 Resolved
Replace discharge line in fwd compartment with rigid non-metallic pipe IAW 46 CFR 182.40-1
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 30 May 2017
Resolution: Line replaced with proper hose.
Construction/Loadline › Hull › Transverse Frame
Issued 21 March 2017 Resolved
Secure stanchion for deck frames in tank compartment IAW 46 CFR 176.25-5
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 31 May 2017
Resolution: Frame attached and secured.
Documentation › Markings/Placards › Warning Signs
Issued 21 March 2017 Resolved
Label bilge pump lights to match compartments IAW 46 CFR 182.530
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 31 May 2017
Resolution: Bilge lights labeled.
Stability › Watertight Integrity › General
Issued 9 March 2016 Resolved
Collision B/H fwd of snack bar stowage area shows light thru, patch as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 25 May 2016
Resolution: Area of concern was properly sealed.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 9 March 2016 Resolved
FWD void for collision B/H area, hatch needs to be secured from being lost.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 25 May 2016
Resolution: Chain was added to hatch cover for securing purpose.
Construction/Loadline › Structures › Ventilators
Issued 9 March 2016 Resolved
E/R vents need repaired, found loose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 25 May 2016
Resolution: Both port and stbd e/r vents were mounted and able to be closed for e/r fire.
Electrical › Electric Supply System (service) › Cable
Issued 9 March 2016 Resolved
E/R cable above port engine need cable holders ever 24", no zip ties.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 25 May 2016
Resolution: Added cable support was done.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 March 2016 Resolved
Panel box in E/R needs labeled.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 25 May 2016
Resolution: Panel box was labeled.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 March 2016 Resolved
Battery box on stbd side in E/R needs properly mounted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 25 May 2016
Resolution: Battery boxes properly mounted.
Engineering › Bilge Water Management System › Manifold
Issued 9 March 2016 Resolved
Bilge manifold in E/R leaks at fitting, needs repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 25 May 2016
Resolution: Found leak was welded and no leaks.
Engineering › Bilge Water Management System › Pump
Issued 9 March 2016 Resolved
Bilge pump in E/R leaks at fitting when running, needs repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 9 March 2016
Resolution: Repaired during exam, and tested.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 9 March 2016 Resolved
Nav lights port and stbd need to verify meeting UL1104 or rule 22.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 25 May 2016
Resolution: Running lights were replaced and working.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 January 2011 Resolved
Provide protective guards for belts on FWD end of port engine
Action required: 705 - Other - as specified
Due 13 February 2011
Resolved 15 February 2011
Resolution: Guards installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 January 2011 Resolved
Replace deteriorated wiring at engine room entrance between light switch and junction box.
Action required: 705 - Other - as specified
Due 13 February 2011
Resolved 15 February 2011
Resolution: Replaced wiring.
Fire Fighting › Fire Main › Valves
Issued 13 January 2011 Resolved
Provide and install cut out valve at fire hydrant
Action required: 705 - Other - as specified
Due 13 February 2011
Resolved 15 February 2011
Resolution: Installed valve.
Lifesaving › Liferaft Equipment › Paddle
Issued 13 January 2011 Resolved
stencil oars with vessel name on the oars of life floats
Action required: 705 - Other - as specified
Due 13 February 2011
Resolved 15 February 2011
Resolution: Stenciled oars.
Lifesaving › Lifefloat › Painter
Issued 13 January 2011 Resolved
Properly mount life float painter line spools
Action required: 15 - Rectify deficiencies by next port
Due 13 February 2011
Resolved 15 February 2011
Resolution: Properly mounted painter spools.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 13 January 2011 Resolved
Provide correct number of lifejackets according to vessels COI
Action required: 705 - Other - as specified
Due 13 February 2011
Resolved 15 February 2011
Resolution: Provided correct number of life preservers.
Construction/Loadline › Hull › Hull Plating
Issued 13 January 2011 Resolved
Vessel is restricted from carrying passengers until fasteners are pulled
Action required: 705 - Other - as specified
Due 13 February 2011
Resolved 15 February 2011
Resolution: Vessel completed hull exam with fasteners pulled.
Lifesaving › Lifefloat › Float-free Link
Issued 15 December 2009 Resolved
Prove proper capacity of all lifefloat painter weak links per 46 CFR 180.137(b).
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 14 January 2010
Lifesaving › Lifefloat › Paddle
Issued 15 December 2009 Resolved
Renew vessel name on lifefloat paddles per 46 CFR 185.604(g).
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 14 January 2010
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 December 2009 Resolved
Provide and install a non-corrosive clip at the waterlight on the ring lifebuoy per 46 CFR 180.70(d).
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 14 January 2010
Construction/Loadline › Hull › Side Shell
Issued 12 October 2005 Resolved
Renew deteriorated planking port side in way of the turn of the approximately six feet forward of the strut to the satisfaction of the attending marine inspector.
Due 21 October 2005
Resolved 21 October 2005
Resolution: Planking was renewed as original and found satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 12 October 2005 Resolved
Renew as original deteriorated planking port side aft eighth plank from keel approximately twelve feet forward of the strut to the satisfaction of the attending marine inspector.
Due 21 October 2005
Resolved 21 October 2005
Resolution: Planking was renewed as original and found satisfactory.
Construction/Loadline › Hull › Keel Plate
Issued 12 October 2005 Resolved
Renew as original deteriorated worm shoe as identified by the attending marine inspector.
Due 21 October 2005
Resolved 21 October 2005
Resolution: Worm shoe was renewed in two areas. An area ten feet forward of the end of the keel and an area just aft of the stem. All repairs were found to be satisfactory as per NVIC 2-95.
Construction/Loadline › Hull › Hull Plating
Issued 12 October 2005 Resolved
Recaulk all butts and seam throughout the underwaterboady of the vessel to the satisfaction of the attending marine inspector in accordance with NVIC 7-95.
Due 21 October 2005
Resolved 21 October 2005
Resolution: All butts and seams were recauled and found satisfactory.
Personnel › Training › First Aid/CPR
Issued 25 October 2004 Resolved
Provide proof of CPR training for 50% of crew.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 January 2005
Resolved 23 February 2005
Resolution: Proof of CPR training was provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 25 October 2004 Resolved
Replace as new worn hoses going from CO2 bottles to fixed piping IAW 46 CFR 181.410.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 January 2005
Resolved 23 February 2005
Resolution: Fire servicing pressure tested hoses to hoses and proved that existing hoses are SAT.
Engineering › Bilge Water Management System
Issued 2 December 2003 Resolved
Provide check valves which are missing on the bilge manifold in the engine room per 46 CFR 182.510(c). LEGACY COMPONENT DESC: Valve
Due 2 January 2004
Resolved 8 March 2004
Resolution: Check valves installed and found satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 2 December 2003 Resolved
Provide shutdowns which are missing for the main engines & generator engine to shutdown the engines prior to release of CO2 in the engine room. 46 CFR 181.410(b)(10).
Due 2 January 2004
Resolved 8 March 2004
Resolution: Conducted operational test of CO2 shutdowns and found satisfactory.
Engineering › Bilge Water Management System
Issued 2 December 2003 Resolved
Replace/renew disconnected emergency bilge piping to the suction side of the fire pump. 46 CFR 182.710. LEGACY COMPONENT DESC: Piping
Due 2 January 2004
Resolved 8 March 2004
Resolution: Piping renewed and operationally tested. No problems noted.
Engineering › Fuel Oil Service System
Issued 2 December 2003 Resolved
Replace the plastic drain cock on the raycor filter wiht a non-combustible drain cock. LEGACY COMPONENT DESC: Filter
Due 2 January 2004
Resolved 8 March 2004
Resolution: Plastic drain cocks replaced with metal drain cocks.
Lifesaving › Buoyant Apparatus
Issued 2 December 2003 Resolved
Replace netting on the lifefloats to comply with 46 CFR 160.027-3(f).
Due 2 January 2004
Resolved 8 March 2004
Resolution: Netting on lifefloats examined and found satisfactory.
Engineering › Fuel Oil Storage/Transfer System
Issued 20 November 2002 Resolved
Tighten reach rod for starboard side fuel tank space. LEGACY COMPONENT DESC: Emergency shut off
Due 20 December 2002
Resolved 12 December 2002
Resolution: Rod tightened at connection.
Lifesaving › Liferaft Equipment
Issued 20 November 2002 Resolved
Replace 6 pairs of lifefloat paddles and label as per 46CFR117.75 LEGACY COMPONENT DESC: Paddle
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2002
Resolution: Paddles replaced and labeled with ship''s name.
Fire Fighting › Fire Pumps
Issued 20 November 2002 Resolved
Provide fire pump gauge on fire main system and prove pump pressure is 60 psi as per 46CFR181.10-1c LEGACY COMPONENT DESC: Gauge
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2002
Resolution: Requirement issued in error. Old "T'' boats are not required to meet this requirement.
Accommodation/Occupational Safety › Medical/First Aid
Issued 20 November 2002 Resolved
Replace expired items in first aid kit as per 46CFR121.710 LEGACY COMPONENT DESC: First Aid kit
Due 20 December 2002
Resolved 12 December 2002
Resolution: Expired items replaced.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 20 November 2002 Resolved
Permanently mount battery box port side engine room as per 46CFR120.350 LEGACY COMPONENT DESC: Battery
Due 20 December 2002
Resolved 12 December 2002
Resolution: Battery box mounted.
Documentation › Certificates/Documents
Issued 20 November 2002 Resolved
Provide proof of certificate of Documentation, valid LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 20 December 2002
Resolved 12 December 2002
Resolution: Verified COD in possession of vessel owner.
Fire Fighting
Issued 19 January 2000 Resolved
PROVIDE SERVICING REPORT FOR THE FIXED CO2 SYSTEM AS PER 46 CFR 176.810(b)(1).
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Lifesaving
Issued 10 December 1998 Resolved
Replace ring buoy as required by 46 CFR 117.70.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Lifesaving
Issued 10 December 1998 Resolved
Remark vessels name and replace retroflective tape on adult life jackets asneeded as required by 46 CFR 117.71.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Construction/Loadline
Issued 20 February 1998 Resolved
RENEW ROTTED PLANK IN WAY OF STARBOARD KEEL COOLER. NVIC 7-95.
Condition: Unknown
Due 20 February 1998
Resolved 11 March 1998
Construction/Loadline
Issued 20 February 1998 Resolved
RENEW 2 ROTTED PLANKS JUST FORWARD OF THE PORT KEEL COOLER. NVIC 7-95.
Condition: Unknown
Due 20 February 1998
Resolved 11 March 1998
Construction/Loadline
Issued 20 February 1998 Resolved
DIG OUT ROTTED AREA OF DEAD WOOD AND FILL WITH SIUTABLE FILLER. NVIC 7-95.
Condition: Unknown
Due 20 February 1998
Resolved 11 March 1998
Construction/Loadline
Issued 20 February 1998 Resolved
SOFT AREA ON PLANK STARBOARD SIDE NEAR THE STEM, SAND DOWN TO GOOD WOOD ANDPAINT NVIC 7-95.
Condition: Unknown
Due 20 February 1998
Resolved 11 March 1998
Construction/Loadline
Issued 20 February 1998 Resolved
RENEW ROTTED BUTT JOINT STARBOARD SIDE, FIRST PLANK OUTBOARD OF THE GARBOARD. NVIC 7-95.
Condition: Unknown
Due 20 February 1998
Resolved 11 March 1998
Electrical
Issued 7 January 1997 Resolved
PROVE PROPER OPERATION OF THE SERVICE GENERATORS AMPERAGE METER.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Electrical
Issued 7 January 1997 Resolved
PROVIDE A MEANS TO MOUNT HAND HELD EMERGENCY LIGHTING (FLASHLIGHTS) 1 EACH IN THE PILOT HOUSE AND 1 EACH AT THE ENGINE ROOM ACCESS.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Construction/Loadline
Issued 7 January 1997 Resolved
PROVIDE BONDING WIRES/STRAPS TO EACH THROUGH HULL FITTING AND MAIN ENGINES IAW COAST GUARD NVIC 7-95.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Navigation
Issued 7 January 1997 Resolved
PROVIDE, INSTALL AND PROVE OPERATION OF COMPASS LIGHT IAW 46 CFR 120.402.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Electrical
Issued 7 January 1997 Resolved
PROVIDE DOCUMENTATION THAT THE SERVICE GENERATOR IS RATED TO 50 DEGREES C OR 40 DEGREES C DERATED TO 80% OF RATED MAXIMUM AMPERAGE. PROVIDE AND POSTPLACARDS IAW 46 CFR 120.312.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Construction/Loadline
Issued 7 January 1997 Resolved
MAKE ALL WATERTIGHT SUBDIVISION BULKHEADS WATER TIGHT IAW 46 CFR 179.320.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Engineering
Issued 7 January 1997 Resolved
PROVIDE AND PORPERLY INSTALL MACHINERY GUARDS ON SERVICE GENERATOR PULLY SYSTEM AND CHAIN/SPROCKET SYSTEM IN STEERING SPACE.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Navigation
Issued 7 January 1997 Resolved
REPACK BOTH THE PORT AND STBD RUDDER STUFFING BOXES.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Engineering
Issued 7 January 1997 Resolved
PROVIDE AND PROPERLY INSTALL FUEL SHUT OFF VALVES AT EACH DIESEL ENGINE IAW46 CFR 119.455(b)(3).
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Lifesaving
Issued 7 January 1997 Resolved
PROVIDE AND INSTALL RETRO REFLECTIVE TAPE ON THE MAIN DECK RING BUOY IAW 46CFR 122.604(i).
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Accommodation/Occupational Safety
Issued 7 January 1997 Resolved
PROVIDE A MEANS TO DETERMINE WHEN THE MSD TANK IS 3/4 FULL BY VOLUME IAW 33CFR 159.83.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Documentation
Issued 28 December 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 December 1994
Resolved 28 December 1994
Documentation
Issued 28 December 1994 Resolved
PROVIDE WRITTEN TRASH DISPOSAL PLAN TO THE [name withheld].
Condition: Unknown
Due 28 December 1994
Resolved 28 December 1994
Navigation
Issued 14 March 1986 Resolved
MOVE MASTHEAD LIGHT TO PROVIDE UNOBSTRUCTED VIEW AS REQUIRED PRIOR TO OPERATING VESSEL AT NIGHT.
Condition: Unknown
Due 14 March 1986
Resolved 14 March 1986
Construction/Loadline
Issued 14 March 1986 Resolved
CONDUCT A STABILITY TEST IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 14 March 1986
Resolved 14 March 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.