MAURY USCG vessel records Sign in
← All vessels

BOONE NO.7

BOONE NO.7 is a 1937 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1984, most recently in September 2024, along with 54 deficiencies and 1 casualty investigation in 2014.

Records from 1984 to 2024. Most recent: inspection, 30 September 2024.

Built
1937
Last inspected
30 September 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTW9167
Flag
UNITED STATES
—
Maury page id
psix-41960

Inspections, by type

…with no type recorded11
Years with a record 38 calendar years (1984–2024)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 23.1 ft × 4.3 ft
Registered tonnagegross 58 / net 58
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTANWOOD CORPORATION · COVINGTON, KY, UNITED STATES · built 1937
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
58 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SUSAN E Towing Vessel · MISLE 201901 · 25 March 2014 · activity 4822644

Inspection history · 67

30 September 2024 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8020460
26 September 2023 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7798654
30 August 2022 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7547077
1 June 2021 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7211644
9 September 2020 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7054403
25 September 2019 Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6820845
3 July 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6737118
18 September 2018 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6542925
15 August 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6513224
16 August 2017 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6249403
15 June 2016 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5910074
25 August 2015 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5225993
25 March 2014 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4822644
25 March 2014 Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4822651
1 December 2011 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4202801
22 July 2009 Drydock Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3542537
7 August 2008 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3291787
26 September 2007 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3071343
28 June 2007 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2976466
30 May 2007 Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2948466
9 August 2006 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2741042
9 August 2005 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2452354
24 August 2004 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2174828
6 August 2003 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1863642
6 August 2003 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2049313
12 June 2003 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1819052
12 May 2003 Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1791754
23 September 2002 Hull Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1677277
8 August 2002 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1661273
9 August 2001 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1362412
9 August 2000 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1403218
12 October 1999 Excursion Permit
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 810080
17 August 1999 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1438902
7 August 1998 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1459450
23 September 1997 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1452331
20 August 1997 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1416556
22 January 1997 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1099870
7 August 1996 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1088517
6 October 1995 Excursion Permit
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 873262
7 August 1995 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 878552
10 August 1994 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 864290
3 February 1994 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 78953
10 August 1993 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1417542
7 October 1992 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 943729
22 September 1992 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1252729
16 August 1992 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 219838
7 August 1992 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1269707
20 May 1992 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 948332
9 September 1991 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1253254
8 August 1991 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1244849
8 August 1991 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1245967
8 August 1990 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1223206
8 August 1989 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1026499
8 August 1989 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1199570
18 August 1988 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1037229
17 August 1988 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1035669
4 May 1988 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1347467
12 August 1987 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1336511
9 June 1987 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1029672
22 September 1986 Deficiency Check
Physical examination · MSO CINCINNATI · Activity 1314336
12 August 1986 Damage Survey
Physical examination · MSO CINCINNATI · Activity 1007142
8 August 1986 COI Inspection
Physical examination · MSO CINCINNATI · Activity 1007255
10 September 1985 Deficiency Check
Physical examination · MSO CINCINNATI · Activity 1296895
18 July 1985 Type not recorded
No type recorded · MSO CINCINNATI · Activity 980907
19 April 1985 Type not recorded
No type recorded · MSO CINCINNATI · Activity 1290101
15 April 1985 Type not recorded
No type recorded · MSO CINCINNATI · Activity 982260
16 July 1984 Type not recorded
No type recorded · MSO CINCINNATI · Activity 980706

Deficiency record · 54

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 June 2021 Resolved
The remote fuel shutout valve was not marked showing purpose of valve. Remote fuel shutout valve must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Mark fuel shut out valve in accordance with 46 CFR 185.608 to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 21 June 2021
Resolution: Fuel shutout was labeled properly.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 June 2021 Resolved
Past drills were not logged or documented. The master shall conduct sufficient drills and give sufficient instruction to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or recovery of persons who have fallen overboard. Once each month if reasonable and perfectible but at least one within 3 months period. Provide records or documentation drills are being completed to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 21 June 2021
Resolution: New log was brought onboard and drills for 1 June, 2021 had been logged.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 June 2021 Resolved
Vessel FCC permit was not on board in accordance with 47 CFR 80.13 Obtain and provide vessel FCC permit to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 21 June 2021
Resolution: FCC permit onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 June 2021 Resolved
Vessel did not have current COI onboard. The certificate inspection must be posted under glass or suitable transparent , material such the that all pages are visible, in a conspicuous place where observation by passengers is likely. Place COI onboard to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 1 June 2021
Resolved 7 July 2021
Resolution: Issued renewal COI. Owner posted under glass.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 September 2018 Resolved
On a vessel authorized to carry one or more vehicles, suitable chains, cables, or other barriers must be installed at the end of each vehicle runway. In addition, temporary rails or equivalent protection must be installed in way of each vehicle ramp, in compliance with the following: Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers and crew and must be be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direction. Please consult with this office before installation to ensure that it meets the intent of this regulation.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2018
Resolved 16 January 2020
Resolution: Safety cargo netting installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 August 2018 Resolved
The Master shall take any necessary precautions to see that automobiles or other vehicles have their motors turned off and their emergency brakes set when the vessel is underway, and that the motors are not started until the vessel is secured to the landing. In addition, the vehicles at each end shall have their wheels securely blocked, while the vessel is being navigated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 10 October 2018
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 August 2018 Resolved
The power fire pump shall be self-priming and of such size as to discharge an effective stream from a hose connected to the highest outlet. All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 10 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2018 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Some of the replacement lifejackets you have provided for your vessel are the new style and require different donning instructions in addition to the ones you already have.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 10 October 2018
Lifesaving › Lifefloat › Serviceable
Issued 16 August 2017 Resolved
PFD ripped.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 September 2017
Resolved 17 August 2017
Engineering › Bilge Water Management System › Not Operational
Issued 16 August 2017 Resolved
Bilge pump not self priming or holding prime IAW 46 CFR 182.25-10. "Existing Vessels"
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2017
Resolved 17 August 2017
Electrical › Electric Generation Source (service) › Power Requirement
Issued 25 March 2014 Resolved
Diagnose the cause for the loss of propulsion that occurred and make any necessary repairs. Prior to getting underway with passengers, demonstrate proper operation of the electric motor and the propulsion system to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2014
Resolved 3 April 2014
Resolution: Cause was determined to be a severed wire between the controller and the electric motor that drives the starboard side paddlewheel. Wire was replaced and underway test of the propulsion system was conducted.
Construction/Loadline › Hull › Stiffener
Issued 22 July 2009 Resolved
Crop and renew angle under port forward deck structure.
Due 7 September 2009
Resolved 7 September 2009
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Bearing
Issued 22 July 2009 Resolved
Replace worn bolts and fasteners in spindle bearings.
Due 7 September 2009
Resolved 7 September 2009
Construction/Loadline › Hull › Bracket
Issued 22 July 2009 Resolved
Repair fractured welds on ramp support angles.
Due 7 September 2009
Resolved 7 September 2009
Construction/Loadline › Structures › Deck Plating
Issued 22 July 2009 Resolved
Repair fractures on vehicle deck.
Due 7 September 2009
Resolved 7 September 2009
Construction/Loadline › Hull › Stiffener
Issued 22 July 2009 Resolved
Crop and renew channel in aft tank port side.
Due 7 September 2009
Resolved 7 September 2009
Construction/Loadline › Hull › Bottom Plating
Issued 22 July 2009 Resolved
Remove scale and rust in all voids, make repairs, and recoat.
Due 7 September 2009
Resolved 7 September 2009
Electrical › Lighting (service) › Conductor
Issued 22 July 2009 Resolved
Properly route wiring to machinery space.
Due 7 September 2009
Resolved 7 September 2009
Construction/Loadline › Structures › Deck Plating
Issued 7 August 2008 Resolved
Deck plating inboard of manhole cover has 1/4 fracture.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 7 September 2009
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 30 May 2007 Resolved
Make permanent repairs to Centerline Bulkhead located between #2 Starboard and #2 Port voids at deck between transverse bottom beams IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 May 2007 Resolved
Portside void #2, Crop and Renew 1st & 2nd transverse bottom beams from ast bulkhead adkacent to center line bulkhead where wasted IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 May 2007 Resolved
Starboard void #2, Crop and Renew 1st transverse bottom beams from ast bulkhead adkacent to center line bulkhead where wasted IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 30 May 2007 Resolved
Repair or Replace leaking diesel tank. Prove tank meets requirements of 46 CFR 182.440.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Construction/Loadline › Structures › Manhole
Issued 30 May 2007 Resolved
Repair area around #2 Starboard void cover where wasted IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Construction/Loadline › Structures › Door
Issued 30 May 2007 Resolved
Repair cracked welds on stern ramp on underside center near hinges IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Construction/Loadline › Structures › Deck Plating
Issued 30 May 2007 Resolved
Replace main deck plate where wasted in area of ladder to pilot house IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Electrical › Lighting (service)
Issued 6 August 2003 Resolved
Install proper globe on passenger deck light fixture. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2003
Resolved 6 August 2003
Resolution: Missing globe replaced.
Engineering › Diesel Engine (propulsion-electric)
Issued 12 May 2003 Resolved
Inspect/make permanent repairs to effected paddle wheel, drive shaft and drive shaft bearing housings. LEGACY COMPONENT DESC: Bearing
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2003
Resolved 12 June 2003
Resolution: Replaced bearing housing and installed new buckets on paddel wheel.
Navigation › Manuals/Policy Documentation
Issued 8 August 2002 Resolved
Emergency broadcast placard missing, 46 CFR 184.506
Due 8 September 2002
Resolved 9 August 2002
Resolution: POSTED AS REQUIRED.
Documentation
Issued 10 August 1993 Resolved
POST VESSEL'S STABILITY LETTER, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Fire Fighting
Issued 10 August 1993 Resolved
SERVICE B-IV SEMI-PORTABLE FIRE EXTINGUISHER STBD SIDE LUBRICATION ROOM, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Fire Fighting
Issued 10 August 1993 Resolved
MOUNT PORTABLE B-II FIRE EXTINGUISHER IN BRACKET ADJACENT TO #2 STARBOARD VOID HATCH, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Fire Fighting
Issued 10 August 1993 Resolved
RENEW LEAKING FIRE HOSE, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Construction/Loadline
Issued 10 August 1993 Resolved
REPAIR HOLES IN DECK ADJACENT TO #2 STARBOARD VOID HATCH OPENING, NOT LATERTHAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Fire Fighting
Issued 10 August 1993 Resolved
SERVICE B-II PORTABLE FIRE EXTINGUISHER IN ENGINE ROOM, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Fire Fighting
Issued 10 August 1993 Resolved
SERVICE B-I PORTABLE FIRE EXTINGUISHER IN PASSENGER CABIN, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Fire Fighting
Issued 7 August 1992 Resolved
RECHARGE PORTABLE FIRE EXTINGUISHER LOCATED IN MACHINERY SPACE NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 15 August 1992
Resolved 19 August 1992
Navigation
Issued 7 August 1992 Resolved
ADJUST WHISTLE CONTROL CABLE SO IT OPERATES WITHOUT BINDING PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 15 August 1992
Resolved 19 August 1992
Electrical
Issued 7 August 1992 Resolved
MARK APPROPRIATE LIGHTING CIRCUITS IN PILOT HOUSE ELECTRICAL DISTRIBUTION PANEL NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 15 August 1992
Resolved 19 August 1992
Fire Fighting
Issued 7 August 1992 Resolved
ATTACH NOZZLE ON 5/8" FIRE HOSE NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 15 August 1992
Resolved 19 August 1992
Electrical
Issued 7 August 1992 Resolved
REPLACE ALL ELECTRICAL WIRE NUTS WITH PRESSURE TYPE WIRE CONNECTORS NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 15 August 1992
Resolved 19 August 1992
Construction/Loadline
Issued 8 August 1991 Resolved
MAKE PERMANENT REPAIR TO THE HOLED #4 STARBOARD VOID VENTILATION DUCT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 8 August 1991
Resolved 8 August 1991
Lifesaving
Issued 8 August 1991 Resolved
REPAIR OR REPLACE INOPERABLE RING BUOY WATERLIGHT PRIOR TO NIGHT TIME OPERATION, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 20 August 1991
Resolved 20 August 1991
Fire Fighting
Issued 12 August 1987 Resolved
PERMANENTLY MOUNT A FIXED FIRE PUMP ON BOARD THE VESSEL. THE SUCTION LINE FOR THIS SYSTEM MAY BE OF A TEMPORARY DESIGN, PROVIDED IT IS ADEQUATELY PROTECTED. A PERMANENT SUCTION LINE SHALL BE CONNECTED TO THE SEA CHEST PRIOR TO NEXT REINSPECTION.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Lifesaving
Issued 8 August 1986 Resolved
REPLACE THE LINE ON THE LIFE RING.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Engineering
Issued 8 August 1986 Resolved
PLACE ADEQUATE GUARDS ON CHAIN SPROCKETS, CHAINS AND FAULK COUPLINGS ON THEPROPULSION MOTORS AND CHAIN ASSEMBLY ON BOTH SIDES OF THE VESSEL.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Lifesaving
Issued 8 August 1986 Resolved
REPLACE THE FALLS ON THE RESCUE BOAT.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Fire Fighting
Issued 8 August 1986 Resolved
PROVIDE PROPER BRACKETS FOR ALL ONBOARD FIRE EXTINGUISHERS.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Electrical
Issued 8 August 1986 Resolved
PROVIDE A NEW JUNCTION BOX AT THE KENTUCKY END PORT RUNNING LIGHT.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Lifesaving
Issued 8 August 1986 Resolved
PROVIDE 11 ADDITIONAL ADULT LIFE JACKETS TO REPLACE DESTROYED JACKETS.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Lifesaving
Issued 18 July 1985 Resolved
VESSEL RESTRICTED TO CARRIAGE OF NOT MORE THAN 36 ADULTS UNTIL THE PROPER NUMBER OF PFDS ARE PROVIDED AND INSPECTED.
Condition: Unknown
Due 18 July 1985
Resolved 18 July 1985
Construction/Loadline
Issued 18 July 1985 Resolved
BOTTOM PLATING CUT AWAY WHERE HOLED. NEW PLATE 48" X 20" INSERT WELDED IN PLACE OF OLD PLATING.
Condition: Unknown
Due 18 July 1985
Resolved 18 July 1985
Electrical
Issued 15 April 1985 Resolved
REMOVE ALL RENEWABLE TYPE FUSES FROM THE VESSEL'S ELECTRICAL SYSTEM, RE- PLACING THEM WITH PROPER EQUIPMENT. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985
Electrical
Issued 15 April 1985 Resolved
PROVIDE WATERPROOF FIXTURES FOR THE EXTERIOR LIGHTING. THESE UNPROTECTED LIGHTS ARE TO BE OPERATED IN FAIR WEATHER ONLY UNTIL PROPERLY PROTECTED.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985

Casualty record · 1

25 March 2014Routine · role: Involved in a Marine Casualty · activity 4822644
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.