BOONE NO.7 is a 1937 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in September 2024, along with 10 deficiencies and 1 casualty investigation in 2014.
Records from 2014 to 2024. Most recent: inspection, 30 September 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)64.8 ft × 23.1 ft × 4.3 ft
Registered tonnagegross 58 / net 58
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTANWOOD CORPORATION · COVINGTON, KY, UNITED STATES · built 1937
Hull materialSteel
PropulsionDiesel Electric
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton 58 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 June 2021Resolved
The remote fuel shutout valve was not marked showing purpose of valve. Remote fuel shutout valve must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Mark fuel shut out valve in accordance with 46 CFR 185.608 to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 21 June 2021
Resolution: Fuel shutout was labeled properly.
Past drills were not logged or documented. The master shall conduct sufficient drills and give sufficient instruction to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or recovery of persons who have fallen overboard. Once each month if reasonable and perfectible but at least one within 3 months period. Provide records or documentation drills are being completed to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 21 June 2021
Resolution: New log was brought onboard and drills for 1 June, 2021 had been logged.
Vessel FCC permit was not on board in accordance with 47 CFR 80.13 Obtain and provide vessel FCC permit to the
satisfaction of the attending Coast Guard Marine
Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 21 June 2021
Resolution: FCC permit onboard.
Vessel did not have current COI onboard. The certificate inspection must be posted under glass or suitable transparent , material such the that all pages are visible, in a conspicuous place where observation by passengers is likely. Place COI onboard to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 1 June 2021
Resolved 7 July 2021
Resolution: Issued renewal COI. Owner posted under glass.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 September 2018Resolved
On a vessel authorized to carry one or more vehicles, suitable chains, cables, or other barriers must be installed at the end of each vehicle runway. In addition, temporary rails or equivalent protection must be installed in way of each vehicle ramp, in compliance with the following: Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers and crew and must be be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direction.
Please consult with this office before installation to ensure that it meets the intent of this regulation.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2018
Resolved 16 January 2020
Resolution: Safety cargo netting installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 August 2018Resolved
The Master shall take any necessary precautions to see that automobiles or other vehicles have their motors turned off and their emergency brakes set when the vessel is underway, and that the motors are not started until the vessel is secured to the landing. In addition, the vehicles at each end shall have their wheels securely blocked, while the vessel is being navigated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 10 October 2018
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 August 2018Resolved
The power fire pump shall be self-priming and of such size as to discharge an effective stream from a hose connected to the highest outlet. All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 10 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2018Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Some of the replacement lifejackets you have provided for your vessel are the new style and require different donning instructions in addition to the ones you already have.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 10 October 2018
Lifesaving › Lifefloat › Serviceable
Issued 16 August 2017Resolved
PFD ripped.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 September 2017
Resolved 17 August 2017
Engineering › Bilge Water Management System › Not Operational
Issued 16 August 2017Resolved
Bilge pump not self priming or holding prime IAW 46 CFR 182.25-10. "Existing Vessels"
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2017
Resolved 17 August 2017
25 March 2014Routine · role: Involved in a Marine Casualty · activity 4822644
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.