Records from 1984 to 2024. Most recent: inspection, 30 September 2024.
Inspection history · 67
30 September 2024
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8020460
26 September 2023
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7798654
30 August 2022
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7547077
1 June 2021
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7211644
9 September 2020
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7054403
25 September 2019
Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6820845
3 July 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6737118
18 September 2018
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6542925
15 August 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6513224
16 August 2017
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6249403
15 June 2016
COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5910074
25 August 2015
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5225993
25 March 2014
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4822644
25 March 2014
Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4822651
1 December 2011
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4202801
22 July 2009
Drydock Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3542537
7 August 2008
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3291787
26 September 2007
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3071343
28 June 2007
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2976466
30 May 2007
Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2948466
9 August 2006
COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2741042
9 August 2005
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2452354
24 August 2004
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2174828
6 August 2003
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1863642
6 August 2003
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2049313
12 June 2003
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1819052
12 May 2003
Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1791754
23 September 2002
Hull Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1677277
8 August 2002
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1661273
9 August 2001
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1362412
9 August 2000
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1403218
12 October 1999
Excursion Permit
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 810080
17 August 1999
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1438902
7 August 1998
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1459450
23 September 1997
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1452331
20 August 1997
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1416556
22 January 1997
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1099870
7 August 1996
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1088517
6 October 1995
Excursion Permit
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 873262
7 August 1995
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 878552
10 August 1994
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 864290
3 February 1994
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 78953
10 August 1993
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1417542
7 October 1992
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 943729
22 September 1992
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1252729
16 August 1992
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 219838
7 August 1992
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1269707
20 May 1992
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 948332
9 September 1991
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1253254
8 August 1991
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1244849
8 August 1991
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1245967
8 August 1990
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1223206
8 August 1989
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1026499
8 August 1989
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1199570
18 August 1988
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1037229
17 August 1988
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1035669
4 May 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1347467
12 August 1987
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1336511
9 June 1987
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1029672
22 September 1986
Deficiency Check
Physical examination · MSO CINCINNATI · Activity 1314336
12 August 1986
Damage Survey
Physical examination · MSO CINCINNATI · Activity 1007142
8 August 1986
COI Inspection
Physical examination · MSO CINCINNATI · Activity 1007255
10 September 1985
Deficiency Check
Physical examination · MSO CINCINNATI · Activity 1296895
18 July 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 980907
19 April 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 1290101
15 April 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 982260
16 July 1984
Type not recorded
No type recorded · MSO CINCINNATI · Activity 980706
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 June 2021
Resolved
The remote fuel shutout valve was not marked showing purpose of valve. Remote fuel shutout valve must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Mark fuel shut out valve in accordance with 46 CFR 185.608 to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 21 June 2021
Resolution: Fuel shutout was labeled properly.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 June 2021
Resolved
Past drills were not logged or documented. The master shall conduct sufficient drills and give sufficient instruction to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or recovery of persons who have fallen overboard. Once each month if reasonable and perfectible but at least one within 3 months period. Provide records or documentation drills are being completed to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 21 June 2021
Resolution: New log was brought onboard and drills for 1 June, 2021 had been logged.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 June 2021
Resolved
Vessel FCC permit was not on board in accordance with 47 CFR 80.13 Obtain and provide vessel FCC permit to the
satisfaction of the attending Coast Guard Marine
Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 21 June 2021
Resolution: FCC permit onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 June 2021
Resolved
Vessel did not have current COI onboard. The certificate inspection must be posted under glass or suitable transparent , material such the that all pages are visible, in a conspicuous place where observation by passengers is likely. Place COI onboard to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 1 June 2021
Resolved 7 July 2021
Resolution: Issued renewal COI. Owner posted under glass.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 September 2018
Resolved
On a vessel authorized to carry one or more vehicles, suitable chains, cables, or other barriers must be installed at the end of each vehicle runway. In addition, temporary rails or equivalent protection must be installed in way of each vehicle ramp, in compliance with the following: Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers and crew and must be be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direction.
Please consult with this office before installation to ensure that it meets the intent of this regulation.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2018
Resolved 16 January 2020
Resolution: Safety cargo netting installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 August 2018
Resolved
The Master shall take any necessary precautions to see that automobiles or other vehicles have their motors turned off and their emergency brakes set when the vessel is underway, and that the motors are not started until the vessel is secured to the landing. In addition, the vehicles at each end shall have their wheels securely blocked, while the vessel is being navigated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 10 October 2018
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 August 2018
Resolved
The power fire pump shall be self-priming and of such size as to discharge an effective stream from a hose connected to the highest outlet. All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 10 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2018
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Some of the replacement lifejackets you have provided for your vessel are the new style and require different donning instructions in addition to the ones you already have.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 10 October 2018
Lifesaving › Lifefloat › Serviceable
Issued 16 August 2017
Resolved
PFD ripped.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 September 2017
Resolved 17 August 2017
Engineering › Bilge Water Management System › Not Operational
Issued 16 August 2017
Resolved
Bilge pump not self priming or holding prime IAW 46 CFR 182.25-10. "Existing Vessels"
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2017
Resolved 17 August 2017
Electrical › Electric Generation Source (service) › Power Requirement
Issued 25 March 2014
Resolved
Diagnose the cause for the loss of propulsion that occurred and make any necessary repairs. Prior to getting underway with passengers, demonstrate proper operation of the electric motor and the propulsion system to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2014
Resolved 3 April 2014
Resolution: Cause was determined to be a severed wire between the controller and the electric motor that drives the starboard side paddlewheel. Wire was replaced and underway test of the propulsion system was conducted.
Construction/Loadline › Hull › Stiffener
Issued 22 July 2009
Resolved
Crop and renew angle under port forward deck structure.
Due 7 September 2009
Resolved 7 September 2009
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Bearing
Issued 22 July 2009
Resolved
Replace worn bolts and fasteners in spindle bearings.
Due 7 September 2009
Resolved 7 September 2009
Construction/Loadline › Hull › Bracket
Issued 22 July 2009
Resolved
Repair fractured welds on ramp support angles.
Due 7 September 2009
Resolved 7 September 2009
Construction/Loadline › Structures › Deck Plating
Issued 22 July 2009
Resolved
Repair fractures on vehicle deck.
Due 7 September 2009
Resolved 7 September 2009
Construction/Loadline › Hull › Stiffener
Issued 22 July 2009
Resolved
Crop and renew channel in aft tank port side.
Due 7 September 2009
Resolved 7 September 2009
Construction/Loadline › Hull › Bottom Plating
Issued 22 July 2009
Resolved
Remove scale and rust in all voids, make repairs, and recoat.
Due 7 September 2009
Resolved 7 September 2009
Electrical › Lighting (service) › Conductor
Issued 22 July 2009
Resolved
Properly route wiring to machinery space.
Due 7 September 2009
Resolved 7 September 2009
Construction/Loadline › Structures › Deck Plating
Issued 7 August 2008
Resolved
Deck plating inboard of manhole cover has 1/4 fracture.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 7 September 2009
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 30 May 2007
Resolved
Make permanent repairs to Centerline Bulkhead located between #2 Starboard and #2 Port voids at deck between transverse bottom beams IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 May 2007
Resolved
Portside void #2, Crop and Renew 1st & 2nd transverse bottom beams from ast bulkhead adkacent to center line bulkhead where wasted IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 May 2007
Resolved
Starboard void #2, Crop and Renew 1st transverse bottom beams from ast bulkhead adkacent to center line bulkhead where wasted IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 30 May 2007
Resolved
Repair or Replace leaking diesel tank. Prove tank meets requirements of 46 CFR 182.440.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Construction/Loadline › Structures › Manhole
Issued 30 May 2007
Resolved
Repair area around #2 Starboard void cover where wasted IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Construction/Loadline › Structures › Door
Issued 30 May 2007
Resolved
Repair cracked welds on stern ramp on underside center near hinges IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Construction/Loadline › Structures › Deck Plating
Issued 30 May 2007
Resolved
Replace main deck plate where wasted in area of ladder to pilot house IAW NVIC 7-68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2007
Resolved 10 October 2007
Electrical › Lighting (service)
Issued 6 August 2003
Resolved
Install proper globe on passenger deck light fixture. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2003
Resolved 6 August 2003
Resolution: Missing globe replaced.
Engineering › Diesel Engine (propulsion-electric)
Issued 12 May 2003
Resolved
Inspect/make permanent repairs to effected paddle wheel, drive shaft and drive shaft bearing housings. LEGACY COMPONENT DESC: Bearing
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2003
Resolved 12 June 2003
Resolution: Replaced bearing housing and installed new buckets on paddel wheel.
Navigation › Manuals/Policy Documentation
Issued 8 August 2002
Resolved
Emergency broadcast placard missing, 46 CFR 184.506
Due 8 September 2002
Resolved 9 August 2002
Resolution: POSTED AS REQUIRED.
Documentation
Issued 10 August 1993
Resolved
POST VESSEL'S STABILITY LETTER, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Fire Fighting
Issued 10 August 1993
Resolved
SERVICE B-IV SEMI-PORTABLE FIRE EXTINGUISHER STBD SIDE LUBRICATION ROOM, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Fire Fighting
Issued 10 August 1993
Resolved
MOUNT PORTABLE B-II FIRE EXTINGUISHER IN BRACKET ADJACENT TO #2 STARBOARD VOID HATCH, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Fire Fighting
Issued 10 August 1993
Resolved
RENEW LEAKING FIRE HOSE, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Construction/Loadline
Issued 10 August 1993
Resolved
REPAIR HOLES IN DECK ADJACENT TO #2 STARBOARD VOID HATCH OPENING, NOT LATERTHAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Fire Fighting
Issued 10 August 1993
Resolved
SERVICE B-II PORTABLE FIRE EXTINGUISHER IN ENGINE ROOM, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Fire Fighting
Issued 10 August 1993
Resolved
SERVICE B-I PORTABLE FIRE EXTINGUISHER IN PASSENGER CABIN, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 17 August 1993
Resolved 19 August 1993
Fire Fighting
Issued 7 August 1992
Resolved
RECHARGE PORTABLE FIRE EXTINGUISHER LOCATED IN MACHINERY SPACE NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 15 August 1992
Resolved 19 August 1992
Navigation
Issued 7 August 1992
Resolved
ADJUST WHISTLE CONTROL CABLE SO IT OPERATES WITHOUT BINDING PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 15 August 1992
Resolved 19 August 1992
Electrical
Issued 7 August 1992
Resolved
MARK APPROPRIATE LIGHTING CIRCUITS IN PILOT HOUSE ELECTRICAL DISTRIBUTION PANEL NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 15 August 1992
Resolved 19 August 1992
Fire Fighting
Issued 7 August 1992
Resolved
ATTACH NOZZLE ON 5/8" FIRE HOSE NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 15 August 1992
Resolved 19 August 1992
Electrical
Issued 7 August 1992
Resolved
REPLACE ALL ELECTRICAL WIRE NUTS WITH PRESSURE TYPE WIRE CONNECTORS NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 15 August 1992
Resolved 19 August 1992
Construction/Loadline
Issued 8 August 1991
Resolved
MAKE PERMANENT REPAIR TO THE HOLED #4 STARBOARD VOID VENTILATION DUCT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 8 August 1991
Resolved 8 August 1991
Lifesaving
Issued 8 August 1991
Resolved
REPAIR OR REPLACE INOPERABLE RING BUOY WATERLIGHT PRIOR TO NIGHT TIME OPERATION, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 20 August 1991
Resolved 20 August 1991
Fire Fighting
Issued 12 August 1987
Resolved
PERMANENTLY MOUNT A FIXED FIRE PUMP ON BOARD THE VESSEL. THE SUCTION LINE FOR THIS SYSTEM MAY BE OF A TEMPORARY DESIGN, PROVIDED IT IS ADEQUATELY PROTECTED. A PERMANENT SUCTION LINE SHALL BE CONNECTED TO THE SEA CHEST PRIOR TO NEXT REINSPECTION.
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Lifesaving
Issued 8 August 1986
Resolved
REPLACE THE LINE ON THE LIFE RING.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Engineering
Issued 8 August 1986
Resolved
PLACE ADEQUATE GUARDS ON CHAIN SPROCKETS, CHAINS AND FAULK COUPLINGS ON THEPROPULSION MOTORS AND CHAIN ASSEMBLY ON BOTH SIDES OF THE VESSEL.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Lifesaving
Issued 8 August 1986
Resolved
REPLACE THE FALLS ON THE RESCUE BOAT.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Fire Fighting
Issued 8 August 1986
Resolved
PROVIDE PROPER BRACKETS FOR ALL ONBOARD FIRE EXTINGUISHERS.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Electrical
Issued 8 August 1986
Resolved
PROVIDE A NEW JUNCTION BOX AT THE KENTUCKY END PORT RUNNING LIGHT.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Lifesaving
Issued 8 August 1986
Resolved
PROVIDE 11 ADDITIONAL ADULT LIFE JACKETS TO REPLACE DESTROYED JACKETS.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Lifesaving
Issued 18 July 1985
Resolved
VESSEL RESTRICTED TO CARRIAGE OF NOT MORE THAN 36 ADULTS UNTIL THE PROPER NUMBER OF PFDS ARE PROVIDED AND INSPECTED.
Condition: Unknown
Due 18 July 1985
Resolved 18 July 1985
Construction/Loadline
Issued 18 July 1985
Resolved
BOTTOM PLATING CUT AWAY WHERE HOLED. NEW PLATE 48" X 20" INSERT WELDED IN PLACE OF OLD PLATING.
Condition: Unknown
Due 18 July 1985
Resolved 18 July 1985
Electrical
Issued 15 April 1985
Resolved
REMOVE ALL RENEWABLE TYPE FUSES FROM THE VESSEL'S ELECTRICAL SYSTEM, RE- PLACING THEM WITH PROPER EQUIPMENT. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985
Electrical
Issued 15 April 1985
Resolved
PROVIDE WATERPROOF FIXTURES FOR THE EXTERIOR LIGHTING. THESE UNPROTECTED LIGHTS ARE TO BE OPERATED IN FAIR WEATHER ONLY UNTIL PROPERLY PROTECTED.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985