MAURY USCG vessel records Sign in
← All vessels

CALIBOGUE

CALIBOGUE is a 1920 passenger vessel (inspected). The Coast Guard has recorded 58 inspections since 1985, most recently in September 2011, along with 88 deficiencies, 1 operational control and 2 casualty investigations between 2010 and 2014.

Records from 1985 to 2014. Most recent: casualty investigation, 4 July 2014.

Built
1920
Last inspected
1 September 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG5073
Flag
UNITED STATES
367543010 (licence lapsed)
Maury page id
psix-41962

Inspections, by type

…with no type recorded2
Years with a record 27 calendar years (1985–2011)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDG5073MMSI 367543010 · expired · compulsorily equipped · granted 21 August 2012, cancelled 22 October 2022
WCX3603MMSI not assigned · expired · compulsorily equipped · granted 1 April 1997, cancelled 3 June 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 58

1 September 2011 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4133098
2 February 2011 Hull Examination · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3928478
30 March 2010 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4197511
15 January 2010 Annual Inspection · Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3664727
5 January 2010 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3658798
4 January 2010 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3658750
14 May 2009 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3467902
5 March 2008 Annual Inspection · Administrative Inspection · Simplified Stability Test
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3158835
29 January 2008 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3145401
14 March 2007 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2911797
14 February 2007 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2871891
22 May 2006 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2673974
5 May 2006 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2672129
7 April 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2331062
14 March 2005 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2328565
15 March 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2024670
10 March 2003 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1751890
4 March 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1752919
4 March 2002 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1490521
29 May 2001 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1452820
14 March 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1422033
23 March 2000 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1381863
5 May 1999 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1429143
20 April 1999 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 807514
24 March 1999 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1120635
24 March 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1402660
7 May 1997 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1448910
25 March 1997 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1409667
10 December 1996 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1092660
25 March 1996 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1380470
23 May 1995 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1355245
28 December 1994 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1178333
1 July 1994 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1367118
16 March 1994 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1025725
19 July 1993 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 842315
15 March 1993 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1152403
10 February 1993 Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 832458
7 April 1992 Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 946020
20 May 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 914173
17 May 1991 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1213412
20 December 1990 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1221814
29 November 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1236242
17 May 1990 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1215145
4 May 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1214671
4 April 1990 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1212411
7 March 1990 COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1218861
28 June 1989 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1348058
24 May 1989 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1210536
9 March 1989 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1043605
20 October 1988 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 888232
27 April 1988 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1037640
18 February 1988 Re-Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1344958
21 May 1987 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1310560
11 March 1987 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1026228
12 May 1986 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1295157
9 April 1986 Credit Drydock
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 998477
13 August 1985 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 984433
14 May 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 982604

Deficiency record · 88

Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 September 2011 Resolved
Failed to make vessel available for annual inspection within 3 months before or after the anniversary date of issuance of Certificate of Inspection. Vessel's anniversary date was 26 Feb 2011 and vessel did not schedule the inspection until 8Sep11.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2011
Resolution: Conducted COI inspection, issued temp COI.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 1 September 2011 Resolved
Bilges shall be kept clean of oil and debris. Machinery space and void space bilges have excessive amounts of oil in them and need to be offloaded and cleaned.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2011
Resolution: Returned to vessel 3 hours after issuing no-sail cg-835. Bilge oily water had been pumped into drums and the bilges wiped clean with oil absorbent mats.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 1 September 2011 Resolved
All openings to the machinery space shall be air tight. Fill the gap in the bottom outboard section of the forward engine room bulkhead.
Condition: Design Flaw
Due 6 October 2011
Resolved 6 October 2011
Resolution: calked and filled hole with foam.
Construction/Loadline › Hull › Keel
Issued 2 February 2011 Resolved
Crop out and replace deteriorated sections of worm shoe
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2011
Resolved 15 February 2011
Resolution: Replaced deteriorated section of worm shoe
Construction/Loadline › Hull › Bottom Plating
Issued 2 February 2011 Resolved
Replace deteriorated sheerstrake plank stbd side of engine rm compt
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2011
Resolved 15 February 2011
Resolution: Replaced sheerstrake plank with pressure treated pine.
Construction/Loadline › Structures › Superstructure
Issued 2 February 2011 Resolved
Replace deteriorated section of overhead of main deck port side
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2011
Resolved 17 February 2011
Resolution: cropped out and replaced deteriorate plywood and 3 stiffiners.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 February 2011 Resolved
Replace deteriorated hand rails on the port side and the stern.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2011
Resolved 17 February 2011
Resolution: Port side - installed support brackets on stanchion and aluminum doubler on handrail. stern - reinforced hand rail at connection with stanchion using epoxy and wood screws.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 February 2011 Resolved
Remove exposed dead-end wires in amidships bilge compartment.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2011
Resolved 15 February 2011
Resolution: Installed junction box on dead-end wire
Documentation › Certificates/Documents › FCC SSL
Issued 14 May 2009 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 22 June 2009
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Certificates/Documents › Stability Letter
Issued 14 May 2009 Resolved
No stability letter onboard. As discussed in Activity ID 3467902, undergo new simplified stability test IAW 46 CFR 78.330 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2009
Resolution: Modified this deficiency to allow for carriage of passengers up to 49 passengers without stability letter IAW 46 CFR 178.320(c). New stability letter for carriage of up to 90 passengers is pending signature authority.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 May 2009 Resolved
Man overboard drill not conducted. Conduct satisfactory man overboard drill IAW 46 CFR 176.840 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2009
Resolution: Conducted man overboard drill with crew; all sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 May 2009 Resolved
Waterlight for ring buoy inoperable. Replace with new waterlight IAW 46 CFR 180.70(d) within 30 days.
Action required: 705 - Other - as specified
Due 14 June 2009
Resolved 22 June 2009
Resolution: Replaced inoperable ring buoy waterlight with new waterlight.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 May 2009 Resolved
Provide battery for waterlight on starboard life float IAW 46 CFR 180.175(f)(4) within 30 days.
Action required: 705 - Other - as specified
Due 14 June 2009
Resolved 22 June 2009
Resolution: Provided battery for waterlight on starboard life float.
Lifesaving › Lifefloat › Markings
Issued 14 May 2009 Resolved
Re-stencil vessel name and max persons on each side of both life floats with 3 inch lettering IAW 46 CFR 185.604(a) within 30 days.
Action required: 705 - Other - as specified
Due 14 June 2009
Resolved 22 June 2009
Resolution: Vessel name and max persons were re-stenciled on each side of both life floats with 3 inch lettering.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 5 March 2008 Resolved
Renew forward packing gland.
Due 3 April 2008
Resolved 14 May 2009
Resolution: Renewed forward packing gland.
Engineering › Bilge Water Management System › Valve
Issued 5 March 2008 Resolved
Install postive shutoff valves on bilge overboard.
Due 3 April 2008
Resolved 14 May 2009
Resolution: Installed positive shutoff valves on bilge overboard.
Engineering › Bilge Water Management System › Piping
Issued 5 March 2008 Resolved
Double clamp hoses on bilge system.
Due 3 April 2008
Resolved 14 May 2009
Resolution: Double clamped hoses on bilge system.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 March 2008 Resolved
Remove dead end wiring in forward peak.
Condition: Improper/Lack of Maintenance
Due 3 April 2008
Resolved 14 May 2009
Resolution: Removed dead end wiring in forward peak.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 5 March 2008 Resolved
Replace fire ext in e/r, missing nozzle.
Condition: Improper/Lack of Maintenance
Due 5 March 2008
Resolved 5 March 2008
Fire Fighting › Fire Pumps › Pressure
Issued 5 March 2008 Resolved
Install pressure gauge on firepump.
Due 3 April 2008
Resolved 14 May 2009
Resolution: Installed pressure gauge on firepump.
Fire Fighting › Nozzles › Condition
Issued 5 March 2008 Resolved
Replace nozzle on fire hose.
Condition: Improper/Lack of Maintenance
Due 3 April 2008
Resolved 14 May 2009
Resolution: Replaced nozzle on fire hose.
Lifesaving › Lifebuoys › Serviceable
Issued 5 March 2008 Resolved
Replace damaged liferings.
Condition: Improper/Lack of Maintenance
Due 5 March 2008
Resolved 5 March 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 March 2008 Resolved
Install pipefittings on all transverse watertight bulkhead penetrations.
Due 3 April 2008
Resolved 14 May 2009
Resolution: Installed pipefittings on all transverse watertight bulkhead penetrations.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 5 March 2008 Resolved
Have tides tables, light list and charts onboard.
Due 5 March 2008
Resolved 5 March 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 March 2008 Resolved
Missing eyewash and aspirin
Condition: Improper/Lack of Maintenance
Due 3 April 2008
Resolved 14 May 2009
Resolution: Provided new first aid kit.
Lifesaving › Lifefloat › Serviceable
Issued 27 February 2007 Resolved
Provide proof of approved repair to both lifefloats. Vessel is restricted from carrying passengers during cold winter months (Oct31-May15) until repairs are completed to the satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 14 March 2007
Resolved 14 March 2007
Resolution: Lifefloats repaired.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 February 2007 Resolved
Replace first aid kit.
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 14 March 2007
Resolution: First aid kit replaced.
Navigation › Collision/Grounding Avoidance › Radar
Issued 26 February 2007 Resolved
Repair radar NLT 31Mar07.
Action required: 705 - Other - as specified
Due 31 March 2007
Resolved 14 March 2007
Resolution: Radar Repaired.
Navigation › Piloting/Steering › US Coast Pilot
Issued 15 March 2004 Resolved
Provide current U S Coast Pilot.
Due 15 April 2004
Resolved 9 April 2004
Resolution: Coast Pilot provided.
Fire Fighting › Fire Pumps
Issued 15 March 2004 Resolved
Demonstrate proper operation of fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2004
Resolved 9 April 2004
Resolution: Demonstrated proper operation.
Documentation › Markings/Placards › Garbage Placard
Issued 15 March 2004 Resolved
Post Garbage placard.
Due 15 April 2004
Resolved 9 April 2004
Resolution: Placard posted.
Construction/Loadline › Hull › Transverse Frame
Issued 10 March 2003 Resolved
Repair or renew aft-most deck beam in way of steering gear/rudder stock. Deck beam decayed in center above rudder support bracket. LEGACY COMPONENT DESC: Deck beam
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 April 2003
Resolved 22 May 2006
Resolution: Repairs made to aft deck beam by sistering on both sides of original beam.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 March 2003 Resolved
MARK LIFE JACKET STORAGE COMPARTMENTS FOR NUMBER OF LIFE JACKETS.
Action required: 705 - Other - as specified
Due 4 April 2003
Resolved 20 August 2004
Lifesaving › Buoyant Apparatus
Issued 4 March 2003 Resolved
ATTACH WATER-LIGHT PAINTERS TO BODY OR EYE OF LIFE FLOATS, VICE GRAB LINES.
Action required: 705 - Other - as specified
Due 4 April 2003
Resolved 4 March 2003
Resolution: WATER LIGHT PAINTERS REMOVED FROM GRAB LINES AND ATTACHED TO BODY OF LIFE FLOAT.
Personnel › Training › First Aid/CPR
Issued 4 March 2003 Resolved
RENEW RED CROSS FIRST AID/CPR CERTIFICATION.
Action required: 705 - Other - as specified
Due 4 April 2003
Resolved 20 August 2004
Operations/Management › Drug and Alcohol Testing
Issued 4 March 2002 Resolved
PROVIDE PROOF OF ENROLLMENT IN DRUG TESTING PROGRAM. ITEM TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Due 15 March 2002
Resolved 23 May 2002
Stability › Watertight Integrity
Issued 4 March 2002 Resolved
SEAL PENETRATION IN BULKHEAD BETWEEN ENGINE SPACE AND TANK SPACE.
Due 11 March 2002
Resolved 4 March 2002
Fire Fighting › Ventilation Systems
Issued 4 March 2002 Resolved
PROVIDE PERMANENT VENTILATION CLOSURES FOR ENGINE COMPARTMENT.
Due 18 March 2002
Resolved 23 May 2002
Lifesaving
Issued 14 March 2001 Resolved
RENEW REFLECTIVE TAPE ON 10 ADULT PFDS.
Condition: Unknown
Due 14 April 2001
Resolved 19 March 2001
Documentation
Issued 14 March 2001 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Navigation
Issued 14 March 2001 Resolved
PROVIDE TIDE TABLE AND COAST PILOT.
Condition: Unknown
Due 14 April 2001
Resolved 19 March 2001
Lifesaving
Issued 14 March 2001 Resolved
REPLACE THREE ADULT PFDS AND REDUCE PASSENGER COUNT BY THREE UNTIL COMPLETED.
Condition: Unknown
Due 14 April 2001
Resolved 19 March 2001
Lifesaving
Issued 14 March 2001 Resolved
PROVIDE CLIP ON RING BUOY WATER LIGHT LINE.
Condition: Unknown
Due 14 April 2001
Resolved 19 March 2001
Navigation
Issued 23 March 2000 Resolved
TIGHTEN RUDDER PACKING.
Condition: Unknown
Due 7 April 2000
Resolved 13 April 2000
Lifesaving
Issued 23 March 2000 Resolved
RENEW REFLECTIVE TAPE ON 20 ADULT LIFE JACKETS.
Condition: Unknown
Due 7 April 2000
Resolved 13 April 2000
Navigation
Issued 23 March 2000 Resolved
REPAIR DEPTH GAUGE.
Condition: Unknown
Due 7 April 2000
Resolved 13 April 2000
Documentation
Issued 23 March 2000 Resolved
PROVIDE PROOF OF RANDOM DURG TESTING.
Condition: Unknown
Due 7 April 2000
Resolved 13 April 2000
Engineering
Issued 23 March 2000 Resolved
PROVIDE CAP FOR VALVE ON BOTTOM OF FUEL TANK.
Condition: Unknown
Due 7 April 2000
Resolved 13 April 2000
Engineering
Issued 23 March 2000 Resolved
REPLACE HOSE CLAMP ON STBD FULE FILL.
Condition: Unknown
Due 7 April 2000
Resolved 13 April 2000
Engineering
Issued 23 March 2000 Resolved
DOUBLE CLAMP FUEL TANK VENT HOSE PORT SIDE.
Condition: Unknown
Due 7 April 2000
Resolved 13 April 2000
Documentation
Issued 24 March 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Engineering
Issued 24 March 1999 Resolved
USE SAE J-1942 FUEL HOSE OR COPPER FOR LENGTHS OVER 30".
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Accommodation/Occupational Safety
Issued 24 March 1999 Resolved
REPAIR LADDER IN FOREPEAK.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Lifesaving
Issued 10 February 1993 Resolved
REPLACE 3 ADULT AND 4 CHILD SIZE LIFE PRESERVERS. TOTAL REQUIRED ON BOARD 93 ADULT AND 10 CHILD SIZE LIE PRESERVERS.
Condition: Unknown
Due 10 February 1993
Resolved 10 February 1993
Construction/Loadline
Issued 10 February 1993 Resolved
REPLACE ALL NONMETALLIC BILGE PIPING, VALVES AND FLEXABLE HOSE WITH METALLIC PIPING AND VALVES. ANY FLEXABLE HOSE USED IN THE BILGE SYSTEM OR FIRE MAIN SYSTEM MUST MEET SAE J-1942 STANDARDS. SEE 46CFR56.60-25(C)
Condition: Unknown
Due 10 February 1993
Resolved 10 February 1993
Lifesaving
Issued 10 February 1993 Resolved
STENCIL ALL STORAGE AREAS FOR LIFE PRESERVERS.
Condition: Unknown
Due 10 February 1993
Resolved 10 February 1993
Lifesaving
Issued 10 February 1993 Resolved
REPAIR OR REPLACE BUOYANT APPARATUS WHICH IS CRACKED AND TORN.
Condition: Unknown
Due 10 February 1993
Resolved 10 February 1993
Construction/Loadline
Issued 10 February 1993 Resolved
CONDUCT AN UNDERWAY EXAM IN ACCORDANCE WITH U.S. COAST GUARD ALDIST 091/85
Condition: Unknown
Due 10 February 1993
Resolved 10 February 1993
Construction/Loadline
Issued 17 May 1991 Resolved
MAKE PERMANENT REPAIRS TO UNDERDECK BREAST PLATE IN FORE PEAK. ISSUED 8MAY91.
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Construction/Loadline
Issued 17 May 1991 Resolved
MAKE PERMANENT REPAIRS TO PORT UNDERDECK LONG IN OUTBOARD CREWS QUARTERS. ISSUED 8MAY91.
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Construction/Loadline
Issued 17 May 1991 Resolved
REPLACE ALL KNEE FRAMES/SAWN FRAMES IN PORT OUTBOARD CREW QUARTERS. ISSUED8MAY91.
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Fire Fighting
Issued 20 December 1990 Resolved
INSTALL SECOND HOSE CLAMP ON RAW WATER INTAKE PORT SIDE ENGINE ROOM.
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Accommodation/Occupational Safety
Issued 20 December 1990 Resolved
PLUG HOSE ENDS AND REMOVE SEACOCK HANDLES FROM THROUGH HULL MIDSHIPS.
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Electrical
Issued 20 December 1990 Resolved
SHORE BATTERIES TO PREVENT EXCESSIVE MOVEMENT.
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Lifesaving
Issued 20 December 1990 Resolved
REMARK PFD STORAGE FOR BOW AREA.
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Construction/Loadline
Issued 20 December 1990 Resolved
EFFECT REPAIR ON SECOND FRAME AFT OF MIDSHIPS BULKHEAD STARBOARD SIDE.
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Engineering
Issued 20 December 1990 Resolved
INSTALL HEAT DEFLECTORS ON FUEL FILTERS
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Engineering
Issued 7 March 1990 Resolved
SHOW THAT FUEL TANK VENTS CONTAIN VENT SCREENS TO BE COMPLETED BY 21MAR90
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Construction/Loadline
Issued 7 March 1990 Resolved
RENEW UPPER SECTION OF FLOOR IN AFT BULKHEAD OF MIDSHIPS COMPARTMENT (PORT/STBD). CROP, SCARF AND RENEW ACCEPTABLE. TO BE COMPLETED BY 7APR90
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Construction/Loadline
Issued 7 March 1990 Resolved
CROP, SCARF/RENEW FRAME HEADS IN MIDSHIP COMPARTMENT (BEAM SECTION) IN FOLLOWING LOCATIONS (PORT SIDE, FRAME IMMEDIATELY FORWARD OF AFT BULK- HEAD, MIDSHIPS COMPARTMENT, STBD SIDE, FOUR FRAMES FORWARD OF AFT BULKHEAD,MIDSHIPS COMPARTMENT. TO BE COMPLETED BY 7APR90
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Documentation
Issued 7 March 1990 Resolved
SUBMIT CERTIFICATE OF DOCUMENTATION TO HAVE COASTWISE ENDORSEMENT PLACED ON CERTIFICATE TO BE COMPLETED BY 7APR90
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Navigation
Issued 7 March 1990 Resolved
PLACE COPY OF RULES OF THE ROAD (INLAND) ON VESSEL TO BE COMPLETED BY 21MAR90
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Fire Fighting
Issued 9 March 1989 Resolved
RENEW OR REPAIR B-II FIRE EXTINGUISHER HANGER ON FIRE EXTINGUISHER IN ENG RM
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Lifesaving
Issued 9 March 1989 Resolved
HANK TOGETHER GRAB LINES ON BOUYANT APPARATUS
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Engineering
Issued 9 March 1989 Resolved
REMOVE WASTE OIL FROM ENG ROOM AND MIS-SHIP BILGES
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Accommodation/Occupational Safety
Issued 18 February 1988 Resolved
PROVIDE ADDITIONAL VENT LINE TO MACHINERY SPACE. VENT SHALL BE OF RIGID FIRE-PROOF CONSTRUCITON.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Lifesaving
Issued 18 February 1988 Resolved
PROVIDE PROPER SIZE WEAKLING FOR 2-20 PERSONS BUOYANT APPARATUS. WEAKLINK SHOULD BE FOR 40 PERSONS.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Navigation
Issued 18 February 1988 Resolved
PROVIDE COPIES OF SMALL PASSENGER VSL REGS (SUB-CHAPTER T), TIDE TABLES, COAST PILOT, NAVIGATION RULES OF ROAD.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Lifesaving
Issued 18 February 1988 Resolved
PROVIDE 12 DISTRESS SIGNALS.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Navigation
Issued 18 February 1988 Resolved
DEMONSTRATE 25 WATT BULB IN PERKO MASTHEAD AND STERN LIGHT PROVIDES SUF- FICIENT VISIBILITY OR RENEW LIGHTS.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Construction/Loadline
Issued 18 February 1988 Resolved
PROVIDE CAPTIVE CHAIN (HINGE) AND SECURING DEVICE TO AFT HATCH COVER. PROVIDE CAPTIVE CHAIN TO FORWARD HATCH COVER TO FOREPEAK.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Engineering
Issued 18 February 1988 Resolved
PROVIDE REACHROD TO SHUT-OFF VALVE TO FUEL VALVE TO TANK. VALVE/REACH ROD SHALL BE ACCESSIBLE FROM WEATHER DECK.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Electrical
Issued 18 February 1988 Resolved
PROPERLY BLOCK BATTERIES IN BATTERY BOX.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Unknown
Issued 11 March 1987 Resolved
REMOVE OIL FROM BILGE.
Condition: Unknown
Due 11 March 1987
Resolved 11 March 1987
Unknown
Issued 11 March 1987 Resolved
PROVE WATERTIGHT INTEGRITY OF COLLISION BULKHEAD IN WAY OF TWO WIRING PENETRATIONS.
Condition: Unknown
Due 11 March 1987
Resolved 11 March 1987
Unknown
Issued 11 March 1987 Resolved
PROVIDE SATISFACTORY OPERATION OF ANCHOR LIGHT.
Condition: Unknown
Due 11 March 1987
Resolved 11 March 1987
Unknown
Issued 11 March 1987 Resolved
PROVIDE PROPER INSTALLATION OF WEAKLINK/PAINTER CANNISTER IN WAY OF BUOYANTAPPARATUS.
Condition: Unknown
Due 11 March 1987
Resolved 11 March 1987
Unknown
Issued 11 March 1987 Resolved
PROVIDE PROPER GRAB LINES FOR RING BUOYS AS NECESSARY.
Condition: Unknown
Due 11 March 1987
Resolved 11 March 1987

Casualty record · 2

30 March 2010Routine · role: Involved in a Marine Casualty · 1 injured · activity 4197511
4 July 2014Routine · role: Involved in a Marine Casualty · activity 4915471
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.