Inspections, by type

…with no type recorded6
…past their stated due date1
Years with a record 27 calendar years (1995–2025)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)70.7 ft × 20.0 ft × 5.4 ft
Registered tonnagegross 51 / net 34
ITC dimensions (L × B × D)70.7 ft × 20.0 ft × 5.4 ft
ITC tonnagegross 133 / net 52
BuilderSKIPPERLINER INDUSTRIES INC · LA CROSSE, WI, UNITED STATES · built 1995
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDUBUQUE, IA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 16 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Regulatory (Subpart C or D), Net Ton
52 - Convention (Subpart B), Net Ton
51 - Regulatory (Subpart C or D), Gross Ton
53 - Displacement, Gross Ton
133 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI8147MMSI 367735720 · expired · compulsorily equipped · granted 21 May 2016, cancelled 27 June 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDB8336MMSI 366957060 · expired · compulsorily equipped · granted 17 June 2004, cancelled 23 August 2014 · licensed under a name not among this hull’s recorded names (not shown)
WCZ7458MMSI not assigned · cancelled · compulsorily equipped · granted 11 April 2000, cancelled 25 February 2010 · licensed under a name not among this hull’s recorded names (not shown)
WCX9359MMSI not assigned · expired · compulsorily equipped · granted 27 January 1998, cancelled 29 March 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 66

26 September 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8243709
30 September 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8011665
15 July 2024 Damage Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7959015
26 September 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7798851
24 May 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7695438
22 November 2022 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7598936
9 October 2022 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7575125
26 July 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7517585
29 June 2021 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7239386
19 August 2020 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7037583
18 June 2019 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6717902
28 May 2019 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6703669
5 June 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6436055
2 November 2017 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6300395
11 July 2017 Spot Check · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6205770
23 June 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6184337
19 June 2017 Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6180831
16 June 2017 Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6177528
16 May 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6147208
10 April 2017 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6121595
23 March 2017 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6110381
22 July 2016 Administrative Inspection · Spot Check · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5949628
21 July 2016 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5948566
4 April 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5846621
28 March 2016 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5842067
26 February 2016 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5822876
10 August 2015 DAPI Audit · Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5219022
13 July 2015 MARPOL Annex VI Survey · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5198383
7 October 2014 Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5000825
26 August 2014 Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4966707
26 June 2014 Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4900093
25 June 2014 DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4901664
9 June 2014 Annual Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4885703
8 May 2012 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4306650
23 February 2012 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4249466
22 September 2011 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4151978
7 September 2011 Damage Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4139196
4 September 2011 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4137106
3 September 2008 In-Service Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3317813
9 May 2008 DAPI Audit · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3202959
19 March 2008 Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3180946
21 May 2007 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 2938674
4 October 2006 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2793369
20 April 2006 COI Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2628457
10 April 2006 Hull Examination · Internal Structural Exam
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2622931
3 October 2005 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2506935
23 May 2005 In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2365640
25 June 2004 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2110364
17 June 2004 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2100534
11 February 2004 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2004396
20 April 2003 Deficiency Check · Damage Survey · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1777715
17 April 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1775545
7 February 2003 Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1741176
3 May 2002 Deficiency Check · Administrative Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1618587
21 March 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1495667
14 March 2002 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1493567
29 January 2002 Hull Examination · Administrative Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1482206
29 March 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1456956
9 March 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1468117
25 January 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1408434
19 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 778366
31 March 1999 MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1388765
23 March 1999 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1113691
21 January 1998 COI Inspection · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1368606
20 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1092991
24 April 1995 Plan Review "T" Boat · Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1398238

Deficiency record · 173

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 September 2025 No resolution recorded
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Operator installed a new generator approximately 2 years ago, no plans were submitted to OCMI for review prior to install. Submit electrical plans for new generator in accordance with procedure E2-23 "Review of Small Passenger Vessels" 46 CFR 176.700(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 September 2025 Resolved
The engine head, block, and exhaust manifold must be water-jacketed and cooled by water from a pump that operates whenever the engine is operating. MI witnessed cooling pumps leaking on starboard engine and hose for cooling leaking on port engine. 46 CFR 182.420(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 26 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2025 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Bilge strainer in fuel void found wasted and inadequate. 46 CFR 182.510(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2025
Resolved 26 March 2026
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards. MI observed thermal breaker dangling at generator battery box and not properly secured. 46 CFR 183.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 26 March 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 September 2025 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Loose combustible material is being stowed on top of fuel tank and in fuel tank void, remove excess material to the satisfaction of the MI. 46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 26 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2025 Resolved
MI observed 02 life rings faded and cracked. Repair or replace to the satisfaction of the marine inspector. 46 CFR 180.70(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 26 March 2026
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2025 Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. Repair or replace warped starboard battery bank cover. 46 CFR 183.354(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 26 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 September 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices... must be corrected. MI observed expansion tank for generator coolant dangling by hose and not properly secured. 46 CFR 176.830(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 26 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 September 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI observed first aid kit on board with expired medications and outdated items list. 46 CFR 184.710 46 CFR 199.175(b)(10)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 26 March 2026
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 September 2025 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Label for fuel shut off is faded and unreadable. 46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 26 March 2026
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 26 September 2025 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions. Emergency instructions are not posted at the operating station. 46 CFR 185.510
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 26 March 2026
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Guards - fencing around dangerous machinery parts
Issued 26 September 2025 Resolved
An exposed hazard...must be properly protected by a... guard. MI observed guard for starboard engine belt uninstalled. 46 CFR 177.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 26 March 2026
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 October 2024 Resolved
Vessel must have a first-aid kit that meets the requirements in ISO 18813:2006(E) paragraph 4.12.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 11 October 2024
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 October 2024 Resolved
Vessel must have current up to date charts and publications. Vessel did not have current Nav rules or charts on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 11 October 2024
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 2 October 2024 Resolved
Vessel captain must have a current medical certificate with their credential while operating a vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 11 October 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 October 2024 Resolved
All MOB, FIRE and ABANDON SHIP drills must be logged to include the date, general descriptions, training topics and who participated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 11 October 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 October 2023 Resolved
If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the OCMI. Vessel representative has failed to correct the deficiencies in the time allotted. Three deficiencies were past due as of October 10, 2023, vessel rep has failed to contact local Coast Guard Marine Inspectors regarding correction. Correct all past due deficiencies prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2023
Resolution: vessel corrected past due deficiencies.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2023 Resolved
Vessel required to have 139 serviceable adult life jackets on board. 44 life jackets had minimal retro-reflectivity remaining. Remove degraded life jackets and replace with CG Approved life jackets with vessel name marked in accordance with 46 CFR 185.604. Each life jacket must be approved in accordance with either 46 CFR 160.002, § 160.005, or § 160.055.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2023
Resolved 25 October 2023
Resolution: passenger count limited to current number of life jackets on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2023 Resolved
Overboard discharge hoses are splitting near the connection to the valve. Replace hoses with appropriate hose material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2023
Resolved 25 October 2023
Resolution: hoses replaced
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2023 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Remove the jumper cables from the generator batteries to the port engine batteries and determine the cause for the batteries to be losing charge, possible alternator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2023
Resolved 25 October 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2023 Resolved
All equipment must be suitable for the voltage and current utilized. Outlet behind food prep table appears burnt. Replace outlet and verify appropriate fuse is installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2023
Resolved 25 October 2023
Resolution: outlet replaced
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2023 Resolved
Cap off or removed wires that are not permanently attached. Wires are in the bilge near the AC skid.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2023
Resolved 25 October 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 September 2023 Resolved
A hatch exposed to the weather must be watertight. Forward bow void hatch is allowing excessive amounts of water in the void. Repair or replace hatch cover gasket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2023
Resolved 25 October 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2023 Resolved
Electrical equipment must be protected from wet environments. Determine the cause of the water intrusion into the pilot house and repair it.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2023
Resolved 25 October 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Starboard battery missing cover, outlet behind buffet missing wall plate, wires not secured in the overhead, Opening in wire pass through from breaker box to engine room (not resealed after the addition of the new battery charger).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2023
Resolved 17 July 2023
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 May 2023 Resolved
Fire extinguishing equipment installed on a vessel must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant. Smoke detectors in the bathrooms were not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2023
Resolved 17 July 2023
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 May 2023 Resolved
The overhead in the engine room was coated in oil and was missing the insulation above both engines. Clean over head and replace the insulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2023
Resolved 11 July 2023
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 24 May 2023 Resolved
The Captain and crew must be aware of the location of all fire equipment and any fire and smoke detectors. The captain as unaware if there were detectors in the engine room and how a fire could be discovered. Train the Captain to the components on the vessel. Determine how a fire will be identifed in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2023
Resolved 13 June 2023
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 July 2022 Resolved
Starboard main engine and Generator leaking oil. Identify cause of leak and repair. Remove excess oil from bilges and off machinery. Conduct a round of engine room prior to getting underway and log it until corrected to the satisfaction of USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 15 August 2022
Resolution: replaced cracked fuel housing.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 26 July 2022 Resolved
Visual and audible high water alarm must be provided at the operating station. The only compartment that was operational was the rudder room. All others need to be repaired/replaced. Conduct rounds of all spaces prior to getting underway and log it until corrected to the satisfaction of USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 15 August 2022
Resolution: all operational
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 26 July 2022 Resolved
The master shall conduct sufficient drills and give sufficient instruction to make sure all crew members are familiar with their duties during emergencies. Crew members had not participated in or received adequate training for MOB, Abandon ship or fire drills since they had been employed. Conduct at least 1 live drill (non table top)for MOB, Fire and abandon ship prior to getting underway with passengers and 2 additional drills of MOB, fire and abandon ship within the following week ensuring that all crew members participate in at least one of each drill and all are logged appropriately.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 15 August 2022
Resolution: conducted multiple drills with all crewmembers
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 July 2022 Resolved
Vessel required to have fixed power Bilge pumps with a capacity of 25 gallons per minute and a portable hand pump with the capacity of 5 GPM. Fixed system tested under the bar was not sufficient was significantly caked with rust and sediment and had not been run since previous CG inspection. Repair/clean out bilge piping to get to required capacity to the satisfaction of USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 15 August 2022
Resolution: tested engine room and bow thruster bilges.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 July 2022 Resolved
Bilge pumps located near the shafts have exposed wiring laying in the bilges. all wiring needs to be protected from bilge water.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 15 August 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 July 2022 Resolved
Repair/ replace/install fresh water pump. DC pump has exposed wiring and is laying in the bilge. Secure power to DC pump until properly repaired and installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 15 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 July 2022 Resolved
Overboard discharge piping the penetrates the exterior hull below or near the water line shall have a operational valve at the hull penetration. Numerous valve handles were stuck and were not operational. will correct during drydock
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 November 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 July 2022 Resolved
Overhead leaking water at operating station onto gauges and electronics panel. Crew member shall be protected from electrical shock and electrical systems shall be protected fro water ingress. Repair the overhead to prevent water from coming through the overhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 15 August 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 July 2022 Resolved
Secure CO2 cylinders in soda room void. 02 cylinders are in bilge unsecured.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 15 August 2022
Resolution: secured cylinders
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 July 2022 Resolved
Battery terminals should only have up to four wires attached with the largest on the bottom and scaling up to the smallest on top. One battery had at least 7 wires off one terminal and 5 off the other terminal.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 15 August 2022
Resolution: installing breaker blocks
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 July 2022 Resolved
Open exposed wiring on aft galley wall port side. Outlet on starboard side behind buffet cart does not have an outlet cover. Passengers and crew shall be protected from electrical shock.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 15 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2022 Resolved
Cover is missing from over the windings on the generator. Replace the cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 22 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 July 2022 Resolved
Retro-reflective materials of sufficient width (5cm) should be applied around or on both sides of the body of the ring buoy at 4 evenly spaced points. The Retro-reflective is only located on one side of the ring buoys and is peeling off.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 15 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 26 July 2022 Resolved
Placards for life jacket donning must be posted for all types of life jackets located on board. Vessel has new vest type life jackets in addition to the previous version. Post additional placard where crew and passengers can see.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 15 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 July 2022 Resolved
Condemned 40 adult life jackets. replace with new life jackets that are marked with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 15 August 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 July 2022 Resolved
Provide USCG Marine Inspectors with Drug and Alcohol Program documentation of implementation and testing program.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 15 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 26 July 2022 Resolved
Vessel owner, master or operator shall instruct each crew member upon first being employed and prior to getting underway and at least once every 3 months of their duties they are expected to perform in an emergency . Crew training shall be logged with date of training and description of training and topics covered and available to coast guard upon request.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 15 August 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 26 July 2022 Resolved
Vessel must have a current light list on board for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 20 September 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 July 2022 Resolved
Provide on board an approved first aid kit with Approval
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 20 September 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 July 2022 Resolved
Hatch coming to bow thruster room is significantly degraded and will need to be repaired during upcoming dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 March 2023
Resolution: Hatch cover and ring were replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 July 2022 Resolved
The intake piping for the fire main as an approx. 4 inch section of nonmetallic flex hose. Remove nonmetallic section and replace with adequate metallic piping during dry dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 16 March 2023
Resolution: nonmettalic piping replaced with steel piping
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 June 2021 Resolved
Vessel to carry 6 distress signals. Order and place onboard 6 USCG approved commercial distress signals.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 July 2021
Resolution: 6 new flares purchased and on board
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 June 2021 Resolved
Vessel has 40 adult lifejackets that are not serviceable. Replace 40 adult life jackets with approved USCG commercial lifejackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 July 2021
Resolution: Replaced 40 adult life jackets
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 June 2021 Resolved
Vessel to maintain generator in serviceable condition. Vessel's generator had windings excessively coated with oil and debris. Service generator windings in accordance with manufactures specifications. Until windings are properly serviced, rounds are to be conducted in the engine room and reported to Master.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 July 2021
Resolution: GENERATOR WINGDINGS CLEANED
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2021 Resolved
Vessel to have fire retardant insulation in engine room. Place fire retardant material on appropriate hangers in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 July 2021
Resolution: NEW INSULATION INSTALLED
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 August 2020 Resolved
Replace 17 condemned adults PFDs. Passenger count reduced to 130 passengers until all 139 PFD on board and placed into service.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 28 September 2020
Resolution: Verified appropiate numbers of PFDs onboard as per the COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2020 Resolved
Replace floating electric water light and water light battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 28 September 2020
Resolution: Verified new waterlight and battery placed into service.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 August 2020 Resolved
Provide on board required amount of distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 28 September 2020
Resolution: Verified appropiate number of approved flares on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2020 Resolved
Service undercharged fire extinguisher near bridge/ 02 deck pax area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 28 September 2020
Resolution: Fire extinguisher was taken out of serviced and a newly serviced, approved extinguisher in place.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 August 2020 Resolved
Install metal supports for wires through engine room, specifically over engines and over egress routes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 28 September 2020
Resolution: Verified metal brackets in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2020 Resolved
Relabel fuel shut off valves in accordance w/ regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 28 September 2020
Resolution: Verified both fuel shut offs properly labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2020 Resolved
Fix or replace crimped hose on power supply for generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 28 September 2020
Resolution: Verified hose was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 August 2020 Resolved
Replace missing light cover in bow thruster room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 28 September 2020
Resolution: Verified all light installed had proper covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2020 Resolved
Affix wires to battery with permanent connections; remove wing nuts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 28 September 2020
Resolution: Verified all batteries had permanent connections.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 August 2020 Resolved
Replace high bilge float switch in bow thruster room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 2 October 2020
Resolution: Vessel rep sent video of bilge alarm testing and function at location and on the bridge.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 August 2020 Resolved
Provide on board an approved first aid kit with Approval Series 160.041 and all approved contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 28 September 2020
Resolution: Verified approved first aid kit and contents.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 19 August 2020 Resolved
Replace non-metal section of fire main in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 28 September 2020
Resolution: Verified fire main was metal pipe throughout, non-metal section was removed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 May 2019 Resolved
Provide onboard required number of distress flares in accordance with 46 CFR 180.68 (b) or (c).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 17 July 2019
Resolution: Owner sent picture to prove new flares with valid expiration date onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 May 2019 Resolved
Install blanks in fuse ports within electrical box in accordance with 46 CFR 183.01-15.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2019
Resolved 17 July 2019
Resolution: Owner sent pictures to porve blanks installed in electrical pannel.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 May 2019 Resolved
Log details of drills such as scenario, training topics and lessons learned for fire and Man Overbaord drills in accordance with 46 CFR 185.524 and 46 CFR 185.520.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2019
Resolved 3 June 2019
Resolution: Master showed logbook created to record all drills, training, etc.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 May 2019 Resolved
Provide suitable bilge strainer having an open area not less than three times the area of the bilge pipe in accordnace with 46 CFR 182.510(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2019
Resolved 3 June 2019
Resolution: Verified installation of new bilge strainer.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 5 June 2018 Resolved
Vessel currently utilizes plastic waste receptacles. Vessel to replace with non combustible receptacles.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2018
Resolved 15 June 2018
Resolution: Vessel currently utilizes plastic waste receptacles. Vessel to replace with non combustible receptacles. .
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 June 2018 Resolved
Bilge High level alarms do not function.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 June 2018
Resolved 5 June 2018
Resolution: Vessel replaced wire connectors to high level alarms.
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 11 July 2017 Resolved
Vessels Starboard Main Engine bolts on the coupling between the prime mover and the shaft were loose. Take bolts and nuts apart and place lock tight on the bolts and tighten them, he will run the vessel and check the tightness' of the bolts. Vessel shall not carry passengers until repairs are made
Condition: Improper/Lack of Maintenance
Due 14 July 2017
Resolved 11 July 2017
Resolution: Vessels Starboard Main Engine bolts on the coupling between the prime mover and the shaft were tightened. Lock tight was placed on the bolts and then tightened, he run the vessel and checked the tightness' of the bolts. Bolts were tight.
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 23 May 2017 Resolved
Vessel needs to install AIS
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 23 June 2017
Resolution: Vessel has installed a Coast Guard approved AIS
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 May 2017 Resolved
Bow thruster does not have a guard cover on belt.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 15 June 2017
Resolution: Guard was installed.
Fire Fighting › Fire Hydrants › Condition
Issued 16 May 2017 Resolved
Fire station on second deck port side needs to be properly marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 15 June 2017
Resolution: Fire station was remarked.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 May 2017 Resolved
Wing nuts on batteries in engine room need to be replaced with bolts.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 15 June 2017
Resolution: wing nuts replaced with bolts
Electrical › Lighting (service) › Lighting Fixture
Issued 16 May 2017 Resolved
LED light behind bar has spliced wire which needs to be replaced.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 15 June 2017
Resolution: Lighting replaced
Lifesaving › Lifebuoys › Serviceable
Issued 16 May 2017 Resolved
Two ring bouys on 2nd deck need retro tape installed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 15 June 2017
Resolution: Retro-flective tape installed
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 May 2017 Resolved
Ring bouy on starboard side 2nd deck needs bouyant line attached to light.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 15 June 2017
Resolution: Buoyant line installed with light
Operations/Management › Vessel Safety Management › Designated Person(s)
Issued 16 May 2017 Resolved
Provide designation of senior deck hand.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 19 June 2017
Resolution: Provided Senior Deck Hand letter
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 April 2016 Resolved
Vessels 60' life line was not buoyant. Vessel is to replace line with 60' buoyant line of a dark color or certified U/V resistant.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 22 July 2016
Resolution: Vessels 60' of non buoyant line was replaced with certified buoyant line
Documentation › Certificates/Documents › FCC SSL
Issued 21 April 2016 Resolved
Station license: (a) Requirement. Stations must have an authorization granted by the Federal Communications Commission. 47CFR 80.405 (a).
Condition: Placed in Improper Service
Due 4 June 2016
Resolved 21 May 2016
Resolution: Verified on FCC website vessel has new FCC SSL Issued 21MAY16, expires 21MAY26.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 21 April 2016 Resolved
Operators License for Licensed members: Operator requirements of the Bridge-to-Bridge Act. Each ship subject to the Bridge-to- Bridge Act must have on board a radio operator who holds a restricted radio telephone operator permit or higher class license. 47 CFR 80.163
Condition: Placed in Improper Service
Due 4 June 2016
Resolved 22 July 2016
Resolution: Captains on board both hold a valid restricted radio telephone operators permit
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 21 April 2016 Resolved
Chaffing identified on starboard main engine throttle cable. Vessel to replace cable and address cause of chaffing. 46CFR152.200
Condition: Damaged By Earlier Event
Due 4 June 2016
Resolved 22 July 2016
Resolution: Throttle cable was replaced and chaffing material was secured to the cable
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 April 2016 Resolved
Station Logs: (3) Radiotelephony stations subject to the Bridge-to-Bridge Act must record entries indicated by paragraphs (e)(1), (3), (5) (6), (7), (10), and (11) of this section. 47CFR80.409 (f)(2)
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 22 July 2016
Resolution: Station logs: (3) Radiotelephony stations subject to the bridge to bridge Act are now being maintained on the bridge
Lifesaving › Hand Flares › Expired
Issued 13 July 2015 Resolved
Replace 2 red flares. 46CFR180.68
Due 20 July 2015
Resolved 30 July 2015
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 13 July 2015 Resolved
Remove empty uncapped oil bottles from under steering console. 46CFR176.830
Due 13 August 2015
Resolved 30 July 2015
Resolution: Uncapped oil bottles removed from under the steering console.
Engineering › Bilge Water Management System › Strainer
Issued 13 July 2015 Resolved
Replace strainer with a strainer that has an open area of not less than 3 times the area of the bilge pipe in the steering room. 46CFR182.510(b)
Due 13 August 2015
Resolved 30 July 2015
Resolution: New strainer replaced the old one which was wasted.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 July 2015 Resolved
Post renewed COD on board the vessel, one on vessel expired on 30JUN15. 46CFR67.163
Due 20 July 2015
Resolved 30 July 2015
Resolution: New COD posted.
Engineering › Bilge Water Management System › Pump
Issued 13 July 2015 Resolved
Remove the automatic aspect of electrical bilge pumps in the bow thruster room. Potential exists for unknowingly pumping oil in to the water. Only can be used and connected to the battery when manned until fixed to the satisfaction of the MI. 46CFR176.830
Due 13 August 2015
Resolved 30 July 2015
Resolution: Manual switch for electric bilge pump replaced the previous automatic switch in the bow thruster room to prevent potential pollution in an overboard discharge situation.
Electrical › Electric Generation Source (service) › Conductor
Issued 13 July 2015 Resolved
Remove or reconnect loose wire on generator. 46CFR183.340
Due 13 August 2015
Resolved 30 July 2015
Resolution: Loose wiring on the generator has been removed
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 July 2015 Resolved
Repair or replace all 6 bilge high level alarms. Vessel must make 30 minute rounds of all 6 spaces while passengers are onboard until fixed to the satisfaction of [name withheld] must be logged. 46CFR182.530, 46CFR182.115(d).
Due 20 July 2015
Resolved 30 July 2015
Resolution: All bilge high level alarms tested SAT.
Fire Fighting › Fire Hoses › Condition
Issued 9 June 2014 Resolved
Vessel fire hose was leaking during functional operational test and does not meet minimum standard of fire hoses as required by 46CFR181.320(b)(1) and 46CFR181.15-5 . Owner must destroyed the current leaking fire hose in the presence of Marine Inspector per 46CFR176.810(c) and replace with a fire hose that meets the above standard. Vessel restricted from carrying passengers U/W until corrected.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2014
Resolved 10 June 2014
Resolution: Old hose was destroyed, New hose installed and tested SAT.
Engineering › Bilge Water Management System › Strainer
Issued 9 June 2014 Resolved
Vessels bilge piping strainer in the #3 compartment was corroded and does not meet minimum standard of bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe as required by 182.25-5(b). Owner must replace stainer. Vessel has to 10JUL14 (30 days) to correct deficiency to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 9 June 2014
Resolution: Owner reinstalled new strainer and tested sat.
Engineering › Lubricating Oil Service System › Gauge
Issued 9 June 2014 Resolved
Vessel port main diesel engine lubricating oil pressure gage was not functioning at the operating station and does not meet minimum standard of gauges to indicate lubricating oil pressure must be provided and readily visible at the operating station as required by 182.410(b) and 182.20-5. Owner must replace the gage. Vessel has to 10JUL14 (30 days) to correct deficiency to the satisfaction of MI
Action required: 705 - Other - as specified
Due 5 September 2014
Resolved 9 June 2014
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 June 2014 Resolved
Vessels remote fuel shutoff valve markings were not ledgable and does not meet minimum standard Remote fuel shutoff stations shall be marked in at least I-inch letters indicating purpose of the valve and direction of operation as required by 185.608. Vessel must remark fuel shut off valve. Vessel has to 10JUL14 (30 days) to correct deficiency to the satisfaction of the attending Marine Inspector
Action required: 705 - Other - as specified
Due 10 July 2014
Resolved 25 June 2014
Resolution: Vessel stenciled new lettering on bulkhead to indicate shutoff valves.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 9 June 2014 Resolved
Vessel has dead end wiring in the compartment containing the Water Heater and does not meet minimum standard of protecting crew, other and the vessel from electrical hazards as required by 46CFR183.200(b) . Owner must make a permanent repair to the electrical installation. Vessel has to 10JUL14 ( 30 days) to correct deficiency to the satisfaction of the attending Marine Inspector
Action required: 705 - Other - as specified
Due 5 September 2014
Resolved 9 June 2014
Stability › Weathertight Integrity › General
Issued 9 June 2014 Resolved
Vessel hatch leading into compartment 1 is not attached and does not meet the minimum standard of Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss as required by 46CFR171.124(b)(2). Owner must fix to meet above standard. Vessel has to 10JUL14 ( 30 days) to correct deficiency to the satisfaction of the attending Marin
Action required: 705 - Other - as specified
Due 5 September 2014
Resolved 9 June 2014
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 June 2014 Resolved
Vessels CO2 bottle for the soda machine was not properly secured from movement and was laying in the bilge in compartment #3 and does not meet the minimum standard suitability for miscellaneous systems as required by46CFR184.01-5. Owner must securely fasten CO2 Bottle. Vessel has to 17JUN14 (7 days) to correct deficiency to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 17 June 2014
Resolved 25 June 2014
Resolution: Vessel demonstrated to MI that the CO2 bottle was properly secured to prevent against shifting.
Engineering › Thrusters › Motor
Issued 9 June 2014 Resolved
Vessel is rebuilding engine and battery charging system for the bow thruster in the collision bulkhead compartment engine. Prior to work being completed, owner must submit plans to Marine Inspectors for evaluation under 46CFR182 and 46CFR183 as required by 46CFR176.700. Once vessels plans are approved, owner can carry out plans to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 5 September 2014
Resolved 9 June 2014
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 8 May 2012 Resolved
Life Jacket stowage location must be marked in a minimum of 2" letters. Child life jackets
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 5 July 2012
Resolution: Life Jacket stowage location is marked in a minimum of 2" letters. Child life jackets
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 8 May 2012 Resolved
Adult life jacket stowage location must be marked with the words "Life Jacket" and not "PFD"
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 5 July 2012
Resolution: Adult life jacket stowage location is marked with the words "Life Jacket" and not "PFD"
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 May 2012 Resolved
Life Ring must be marked with Vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 5 July 2012
Resolution: Life Ring is marked with Vessel name.
Lifesaving › Hand Flares › Quantity
Issued 8 May 2012 Resolved
Vessel did not have sufficient quantity of Distress signals
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 18 July 2012
Resolution: Vessel has sufficient quantity of Distress signals
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 May 2012 Resolved
Medications in first aid kit found expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 10 July 2012
Resolution: Medications in first aid kit replaced with current medication.
Stability › Watertight Integrity › General
Issued 8 May 2012 Resolved
Wire run between the collision bulkhead and No.1 Void must be made watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 10 July 2012
Resolution: Wire was run between the collision bulkhead and No.1 Void, was replaced with watertight fitting.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 May 2007 Resolved
Conduct annual servicing of portable fire fighting extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2007
Resolved 24 May 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 May 2007 Resolved
Demonstrate proper operation of bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2007
Resolved 24 May 2007
Resolution: Bilge alarms are in satisfactory operation.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 20 April 2006 Resolved
Provide proof of DAPI enrollment
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 5 May 2006
Resolution: reviewed Dapi info all sat.
Personnel › Training › Familiarization Training
Issued 20 April 2006 Resolved
Perform man overboard and fire drills when new owner has crew in place.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 5 May 2006
Resolution: Performed sat drills with crew at La Crosse, WI
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 23 May 2005 Resolved
CAP OFF OR LOCK SEWAGE DISCHARGE IN WAY OF LAZERETTE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2006
Resolution: Vessel Fitted with Pump out port on deck above waterline.
Construction/Loadline › Hull › Bottom Plating
Issued 23 May 2005 Resolved
GUAGE BOTTOM PLATE IN WAY OF KEEL IN LAZERETTE, PORT SIDE AFT WHERE WASTED AND PROVIDE LOCAL OCMI W/PROPOSED REPAIR PLANS
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2006
Resolution: Vessel repaired to the satisfaction of attending marine inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 23 May 2005 Resolved
REMOVE ALL BILGE SUCTION STRAINERS AND DE-RUST HULL PLATE UNDERNEATH.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2006
Resolution: All voids cleaned and painted
Navigation › Piloting/Steering › Steering Magnetic Compass
Issued 17 June 2004 Resolved
Properly install and prove proper operation of the compass light.
Action required: 705 - Other - as specified
Due 2 July 2004
Resolved 12 July 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 17 June 2004 Resolved
Properly wire the 2 VHF radios on seperate circuits.
Action required: 705 - Other - as specified
Due 2 July 2004
Resolved 12 July 2004
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 17 June 2004 Resolved
Properly place the vessel name on the port and starboard bows.
Action required: 705 - Other - as specified
Due 2 July 2004
Resolved 12 July 2004
Construction/Loadline › Hull › Bottom Plating
Issued 11 February 2004 Resolved
Descale and make ready for gauging hull plate under fuel tank.
Due 11 March 2004
Resolved 16 February 2004
Construction/Loadline › Hull › Hull Plating
Issued 11 February 2004 Resolved
Re-install fender screws along port side of vsl along the gunnel. LEGACY COMPONENT DESC: Side Shell
Action required: 705 - Other - as specified
Due 11 March 2004
Resolved 16 February 2004
Construction/Loadline › Hull › Bottom Plating
Issued 11 February 2004 Resolved
De-scale and make ready for gauging plate under A/C condenser in engine room.
Due 11 March 2004
Resolved 16 February 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 February 2004 Resolved
Remove dead ended cables throughout the vessel. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 11 March 2004
Resolved 24 February 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 February 2004 Resolved
All electrical splices must be in an enclouser. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 11 March 2004
Resolved 24 February 2004
Engineering › Bilge Water Management System › Hose
Issued 11 February 2004 Resolved
Re-new gray water discharge hose on port side of engine room.
Due 11 March 2004
Resolved 16 February 2004
Construction/Loadline › Penetrations › Valve Flange
Issued 11 February 2004 Resolved
In void 5, prepare thru-hull valves for inspection.
Due 11 March 2004
Resolved 16 February 2004
Construction/Loadline › Hull › Side Shell
Issued 11 February 2004 Resolved
Make proper repair to starboard transom corner, crop out plate where heated and peened and re-new.
Due 11 March 2004
Resolved 24 February 2004
Construction/Loadline › Structures › Scuttle
Issued 11 February 2004 Resolved
Make repairs to closure device for forepeak hatch.
Due 31 March 2004
Resolved 4 March 2004
Construction/Loadline › Structures › Superstructure
Issued 11 February 2004 Resolved
Repair broken window at aft starboard side.
Due 31 March 2004
Resolved 4 March 2004
Engineering › Bilge Water Management System › Piping
Issued 11 February 2004 Resolved
Prove suction from all spaces served by bilge dewatering system.
Due 11 March 2004
Resolved 4 March 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 February 2004 Resolved
Make repairs to damaged transverse frames in #2 void
Due 11 March 2004
Resolved 24 February 2004
Fire Fighting › Fire Pumps
Issued 21 April 2003 Resolved
Demonstrate a properly operating fire pump LEGACY COMPONENT DESC: Power Source
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 27 June 2003
Communications › Alarms/Indicators
Issued 21 April 2003 Resolved
Demonstrate a properly operating bilge high level alarm LEGACY COMPONENT DESC: Bilge Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 27 June 2003
Navigation › Piloting/Steering
Issued 21 April 2003 Resolved
Provide current navaigation publications LEGACY COMPONENT DESC: US Coast Pilot
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 27 June 2003
Fire Fighting › Remote Fuel Shutoff
Issued 21 April 2003 Resolved
Provide properly operating emergency F/O shut-off valves
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 27 June 2003
Lifesaving › Lifejacket/PFD (General)
Issued 21 April 2003 Resolved
Ensure all lifejackets are correctly labeled with vessel name. Lifejackets are labeled with vessels previous name. LEGACY COMPONENT DESC: Marking
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 27 June 2003
Engineering › Fuel Oil Service System
Issued 21 April 2003 Resolved
Provide flameshield for Racor fuel filter LEGACY COMPONENT DESC: Filter
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 30 June 2003
Engineering › Sea-water System (primary cooling)
Issued 21 April 2003 Resolved
Repair sea suction valve for Bow thruster engine LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 27 June 2003
Operations/Management › Drug and Alcohol Testing
Issued 21 April 2003 Resolved
Provide participation documentation of drug testing program LEGACY COMPONENT DESC: Employee Coverage
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 30 June 2003
Personnel › Certificates/Documents/Licenses
Issued 21 April 2003 Resolved
Provide current COI and post behind transparent material
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 27 June 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 21 April 2003 Resolved
Provide sea rails for oven hotplates
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 30 June 2003
Engineering › Bilge Water Management System
Issued 21 April 2003 Resolved
Provide a properly operating bilge pump LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 27 June 2003
Engineering › Bilge Water Management System
Issued 21 April 2003 Resolved
Provide a portable hand bilge pump LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 27 June 2003
Documentation › Certificates/Documents
Issued 21 April 2003 Resolved
Provide a current FCC Station llicense LEGACY COMPONENT DESC: FCC SSL
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 30 June 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 April 2003 Resolved
Repair port engine, verify quality of fuel, demonstrate to CG inspector proper operation of engine.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2003
Resolved 21 April 2003
Lifesaving › Lifebuoys
Issued 21 April 2003 Resolved
Replace lifering on starboard aft embarkation station
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2003
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 21 April 2003 Resolved
Provide anchor
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2003
Resolved 17 June 2003
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 21 April 2003 Resolved
Repair port MDE R/W strainer
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 7 February 2003 Resolved
RENEW ALL BROKEN WINDOWS IN WAY OF PASSENGER ACCOMODATIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2003
Resolved 28 February 2003
Construction/Loadline › Hull
Issued 7 February 2003 Resolved
PROPERLY REPAIR FRACTURE APPROX 8" LONG LOCATED AT STARBOARD STERN SIDESHELL/SUPERSTRUCTURE CONNECTION. LEGACY COMPONENT DESC: Side Shell
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2003
Resolved 28 February 2003
Navigation › Collision/Grounding Avoidance
Issued 7 February 2003 Resolved
PROVIDE A PROPER STERN NAVIGATION LIGHT. LEGACY COMPONENT DESC: Navigation Lights
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2003
Resolved 28 February 2003
Documentation › Certificates/Documents
Issued 3 May 2002 Resolved
Provide new documentation certificate reflecting name change. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 31 May 2002
Resolved 26 July 2002
Personnel › Training
Issued 3 May 2002 Resolved
Conduct crew training and repeat drills. LEGACY COMPONENT DESC: Familiarization Training
Due 6 May 2002
Resolved 6 May 2002
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 3 May 2002 Resolved
Provide tide tables, tidal currents and light list.
Due 6 May 2002
Resolved 6 May 2002
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 May 2002 Resolved
Replace water light battery.
Due 6 May 2002
Resolved 6 May 2002
Engineering › Sea-water System (primary cooling)
Issued 14 March 2002 Resolved
Properly repair raw water pump leak on bow thruster engine. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Due 1 April 2002
Resolved 3 May 2002
Navigation › Piloting/Steering
Issued 14 March 2002 Resolved
Provide all current navigation publications required. LEGACY COMPONENT DESC: Coast Guard Light List
Due 15 April 2002
Resolved 21 March 2002
Personnel › Training
Issued 14 March 2002 Resolved
Provide current training log. LEGACY COMPONENT DESC: Training log
Condition: Improper/Lack of Maintenance
Due 15 April 2002
Resolved 21 March 2002
Navigation › Piloting/Steering
Issued 14 March 2002 Resolved
Provide current bridge log. LEGACY COMPONENT DESC: Bridge log
Due 15 April 2002
Resolved 21 March 2002
Documentation › Certificates/Documents
Issued 14 March 2002 Resolved
Provide documentaton with proper name of vessel.
Due 15 May 2002
Resolved 3 May 2002
Documentation › Markings/Placards
Issued 14 March 2002 Resolved
Properly post maximum passengers allowed on upper deck. LEGACY COMPONENT DESC: Capacity Marking
Due 15 April 2002
Resolved 3 May 2002
Engineering › Shafting/Propeller Arrangements
Issued 28 January 2002 Resolved
Replace cutlass bearings on port and staboard shafts prior to 25 mar 02. LEGACY COMPONENT DESC: Strut Bearing
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 2002
Resolved 21 March 2002
Engineering › Thrusters
Issued 28 January 2002 Resolved
Replace/renew engine mounts on bow thruster engine mounts. LEGACY COMPONENT DESC: Diesel Engine Mounts
Condition: Unknown
Due 25 March 2002
Resolved 3 May 2002
Deck/Cargo
Issued 31 March 1999 Resolved
Install chain and line combination on vsl anchor.
Condition: Unknown
Due 7 April 1999
Resolved 27 May 1999
Construction/Loadline
Issued 31 March 1999 Resolved
Install bilge high level alarm. IAW 46 CFR 182.530.
Condition: Unknown
Due 14 April 1999
Resolved 27 May 1999
Accommodation/Occupational Safety
Issued 31 March 1999 Resolved
Repair water leak on AC overboard discharge line prior to sailing.
Condition: Unknown
Due 1 April 1999
Resolved 27 May 1999
Electrical
Issued 31 March 1999 Resolved
Remove dead end wires from galley.
Condition: Unknown
Due 7 April 1999
Resolved 27 May 1999
Documentation
Issued 31 March 1999 Resolved
Provide drug testing documentation as per check list.
Condition: Unknown
Due 7 April 1999
Resolved 27 May 1999
Documentation
Issued 31 March 1999 Resolved
Provide vsl Certificate of documentation.
Condition: Unknown
Due 7 April 1999
Resolved 27 May 1999
Fire Fighting
Issued 31 March 1999 Resolved
Install one B-I fire extinguisher in pilot house prior to sailing.
Condition: Unknown
Due 1 April 1999
Resolved 27 May 1999
Electrical
Issued 31 March 1999 Resolved
Renew raw water suction flex hose on S/S generator and double clamp at both ends.
Condition: Unknown
Due 7 April 1999
Resolved 27 May 1999
Lifesaving
Issued 31 March 1999 Resolved
Provide one child's life jacket proir to sailing.
Condition: Unknown
Due 1 April 1999
Resolved 27 May 1999
Construction/Loadline
Issued 21 January 1998 Resolved
Provide oil pollution plaque
Condition: Unknown
Due 12 March 1998
Resolved 27 February 1998
Lifesaving
Issued 21 January 1998 Resolved
Provide life jacket plaque
Condition: Unknown
Due 21 January 1998
Resolved 27 February 1998
Fire Fighting
Issued 21 January 1998 Resolved
Provide B-I portable extinguisher for pilot house.
Condition: Unknown
Due 12 February 1998
Resolved 27 February 1998
Lifesaving
Issued 21 January 1998 Resolved
Install latches on galley hatch and #3 hold hatch.
Condition: Unknown
Due 12 March 1998
Resolved 27 February 1998

Casualty record · 3

4 September 2011Routine · role: Involved in a Marine Casualty · activity 4137106
18 June 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6717902
9 October 2022Routine · role: Involved in a Marine Casualty · activity 7575125
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.