Inspection history · 47
27 September 1995
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1189867
4 February 1994
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1162558
9 December 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1159788
24 November 1993
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1159785
19 May 1993
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1133229
29 January 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1132558
5 June 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265735
25 February 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 954927
4 February 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1265276
11 June 1991
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 482937
22 March 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997816
8 February 1991
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 904517
12 September 1990
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 538509
9 April 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 920605
3 April 1990
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 907086
13 March 1990
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1217826
8 February 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 921744
31 January 1990
Damage Survey · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 910833
30 December 1989
Permit to Proceed
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 922655
8 August 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1035007
21 July 1989
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 896231
18 July 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1204518
13 July 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1043530
8 June 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 457779
14 April 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1212081
10 March 1989
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1038934
17 October 1988
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 886628
13 October 1988
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 887563
23 August 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 475330
31 March 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 529859
11 March 1988
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1030448
2 February 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1325030
17 September 1987
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 487217
20 July 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020660
25 June 1987
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1013955
20 March 1987
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 523072
14 November 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1010479
8 October 1986
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 501295
12 April 1986
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 507048
12 March 1986
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1303452
9 October 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 462952
13 June 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1287683
6 June 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1287840
17 April 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 525069
5 November 1984
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 298716
1 November 1984
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 437242
15 May 1984
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 530819
Deck/Cargo
Issued 24 November 1993
Resolved
PRIOR TO CARRYING CARGOES CONTAINING MORE THAN 0.5% BENZENE BY VOLUME, COMPLETE REQUIREMENTS AS APPLICABLE IN ACCORDANCE WITH 46 CFR PART 197, SUBPART C.
Condition: Unknown
Due 24 December 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 24 November 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE, PROVIDE COPIES OF VALID LICENSES FOR REQUIRED CREW.
Condition: Unknown
Due 24 December 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 24 November 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE, PROVIDE EVIDENCE OF CURRENT PRE- EMPLOYMENT AND RANDOM DRUG TESTING IN ACCORDANCE WITH 46 CFR PART 4 AND PART 16.
Condition: Unknown
Due 24 December 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 24 November 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE, CONDUCT WEIGHT TEST OF THE PORT LIFEBOAT IN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Engineering
Issued 24 November 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE, OPEN AND MAKE AVAILABLE FOR INTERNAL EXAM OR CONDUCT A 125% MAWP HYDROSTATIC TEST OF THE 5 INSTALLED PRESSURE VESSELS.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Fire Fighting
Issued 24 November 1993
Resolved
REMOVE OR REPAIR AND PROVE PROPER OPERATION OF THE FIXED FOAM SYSTEM.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Lifesaving
Issued 29 January 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE, CONDUCT EMERGENCY DRILLS WITH THE ENTIRE CREW IN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 31 October 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 29 January 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE, CALCULATE AND POST NEAR THE PILOT HOUSEMAGNETIC STEERING COMPASS, A MAGNETIC COMPASS DEVIATION TABLE.
Condition: Unknown
Due 31 October 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 29 January 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE, PROVIDE ON BOARD CURRENT AND CORRECTED EDITIONS OF ALL REQUIRED CHARTS AND PUBLICATIONS.
Condition: Unknown
Due 31 October 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 29 January 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE, FABRICATE AND INSTALL A SHAFT GUARD ON THE PUMP AT THE BOTTOM OF THE ENGINE ROOM LADDER.
Condition: Unknown
Due 29 April 1993
Resolved 4 February 1993
Engineering
Issued 29 January 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE, TEST RELIEF VALVE ON AIR RECEIVER #3.
Condition: Unknown
Due 29 April 1993
Resolved 4 February 1993
Construction/Loadline
Issued 29 January 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE, FABRICATE AND INSTALL A SHAFT GUARD ON THE PORT SHAFT PACKING BILGE PUMP.
Condition: Unknown
Due 29 April 1993
Resolved 4 February 1993
Documentation
Issued 4 February 1992
Resolved
PROVIDE PLANS AND SPECIFICATIONS FOR NEW INSTALLATION OF ELECTRIC FIRE PUMPAND WATER HEATER. SUBMIT TO OCMI MSO BOSTON.
Condition: Unknown
Due 15 March 1992
Resolved 25 February 1992
Engineering
Issued 4 February 1992
Resolved
PROVE PROPER OPERATION OF PORT AND STARBOARD REMOTE FUEL OIL SHUT OFFS.
Condition: Unknown
Due 15 March 1992
Resolved 25 February 1992
Navigation
Issued 4 February 1992
Resolved
PORT AND STARBOARD RUDDER BUSHINGS WORN, RUDDER POSTS HAVE EXCESS MOVEMENT.RENEW RUDDER POST BUSHINGS.
Condition: Unknown
Due 4 February 1992
Resolved 4 February 1992
Construction/Loadline
Issued 4 February 1992
Resolved
RENEW VENT CLOSURES TO GALLEY, GOOSENECK PORTSIDE FANTAIL AND FORWARD COFFERDAM. REPAIRS TO BE MADE TO SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1992
Resolved 4 February 1992
Fire Fighting
Issued 4 February 1992
Resolved
PROVIDE PRESSURE GUAGE FOR DISCHARGE SIDE OF PORTSIDE ENGINE ROOM FIRE PUMP.
Condition: Unknown
Due 29 February 1992
Resolved 25 February 1992
Construction/Loadline
Issued 4 February 1992
Resolved
RENEW HATCH/SCUTTLE TO STEERING GEAR COMPARTMENT AND PROVE PROPER OPERATIONTO ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1992
Resolved 4 February 1992
Lifesaving
Issued 8 February 1990
Resolved
REPLACE OUTDATED ROCKETS FOR THE LINE THROWING GUN AND PROVIDE A GUN CLEARING KIT FOR THE SAME.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Engineering
Issued 8 February 1990
Resolved
PROVE PROPER OPERATION OF MAIN DIESEL ENGINE OVERSPEED TRIP.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Engineering
Issued 8 February 1990
Resolved
AMEND APPROVED AUTO MOTION TEST PROCEDURES DATED 28 MAR 1983 TO REFLECT CURRENT INSTALLATION/PROVEDURE FOR MAIN DIESEL ENGINE PROPULSION OVERSPEED TRIPS.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Construction/Loadline
Issued 18 July 1989
Resolved
MAINTAIN CARGO TANKS IN EMPTY CONDITION. GAS FREE AND MAKE AVAILABLE FOR INTERNAL EXAM #3 CARGO TNK. DRYDOCK VESSEL MAKE PERMANENT REPAIR TO WASTEDHOLE IN HULL IN PLACE OF TEMPERORY REPAIR.
Condition: Unknown
Due 18 July 1989
Resolved 18 July 1989
Construction/Loadline
Issued 13 July 1989
Resolved
GAS FREE AND PRESENT NO THREE STARBARD TANK FOR INSPECTION.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Navigation
Issued 10 March 1989
Resolved
REWIRE BRIDGE RUNNING LIGHTS AND MAKE WATERTIGHT.
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989
Lifesaving
Issued 10 March 1989
Resolved
CONDUCT FIRE AND BOAT DRILL.
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989
Lifesaving
Issued 10 March 1989
Resolved
PROCURE TWO ORANGE FLOATING SMOKE DISTRESS SIGNALS, TWO RATIONS MILK, 12 QUARTS OF WATER AND 12 HAND HELD RED FLARES FOR LIFEBOAT.
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989
Lifesaving
Issued 10 March 1989
Resolved
PROCURE 12 HAND HELD RED FLARES FOR VESSEL ITSELF.
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989
Construction/Loadline
Issued 10 March 1989
Resolved
REPAIR ONE BENT STANCHION MIDSHIP STARBOARD.
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989
Lifesaving
Issued 11 March 1988
Resolved
CONDUCT WEIGHT TEST OF LIFEBOAT.
Condition: Unknown
Due 11 March 1988
Resolved 11 March 1988
Deck/Cargo
Issued 2 February 1988
Resolved
OPEN-CLOSED INDICATORS MISSING FROM NON RISING STEM IN THE CARGO PIPING SYSIAW 46 CFR 56.20 PROVIDE NON RISING STEM CARGO VALVES WITH INDICATOR OR RE-PLACE VALVES WITH RISING STEM TYPE.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Lifesaving
Issued 25 June 1987
Resolved
CONDUCT AND LOG AN ABANDON SHIP DRILL WHICH INCLUDES LOWERING, RELEASING AND OPERATION OF LIFEBOATS IN WATER. SEND COPY OF LOG ENTRY TO OCMI, NY.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Construction/Loadline
Issued 12 March 1986
Resolved
EXHAUST STACK STRUCTURE WASTED THROUGH AT DECK LEVEL. EFFECT PERMANENT REPAIR BY CROPPING TO GOOD METAL AND RENEWING.
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986
Unknown
Issued 12 March 1986
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986
Lifesaving
Issued 12 March 1986
Resolved
PROVIDE PERMANENT MOUNTING BRACKET FOR RING BUOY ON FORWARD WEATHER DECK.
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986