MAURY USCG vessel records Sign in
← All vessels

REBECCA K

REBECCA K is a 1938 freight ship. The Coast Guard has recorded 3 inspections since 1984, most recently in February 1986, along with 28 deficiencies.

Records from 1984 to 1986. Most recent: inspection, 13 February 1986.

Built
1938
Last inspected
13 February 1986
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5351337 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WB3557
Flag
UNITED STATES
—
Maury page id
psix-41969

Inspections, by type

…with no type recorded3
Years with a record 3 calendar years (1984–1986)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 40 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1429 - Regulatory (Subpart C or D), Gross Ton
813 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

13 February 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1293074
10 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 983375
6 December 1984 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 976281

Deficiency record · 28

Engineering
Issued 6 December 1984 Resolved
REPLACE THE FLEXIBLE FUEL OIL HOSES AT THE END OF EACH MAIN DIESEL ENGINE WITH ONES COMPLING WITH 46 CFR 56.60-25(C) (FUEL SYSTEMS)
Condition: Unknown
Due 15 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 6 December 1984 Resolved
REPLACE/RENEW THE STERN TUBE COOLING VALVE AT THE STARBOARD TAIL SHAFT AND AND THE PIPING BETWEEN THE VALVE AND THE BHD PENETRATION.
Condition: Unknown
Due 15 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 6 December 1984 Resolved
MAKE A PERMANENT MOUNT FOR THE AUX BOILER'S FUEL OIL FILTER.
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Engineering
Issued 6 December 1984 Resolved
HYDROSTATICALLY TEST AUX BOILER TO IT'S MAWP (30 PSI).
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Electrical
Issued 6 December 1984 Resolved
REMOVE ALL PLASTIC CABLES TIES ON ELECTRICAL WIRING THROUGHOUT THE SHIP (INCLUDING, BUT LIMITED TO THE ENGINEROOM, ACCOMMODATIONS AND BOSN'S LOCKER FORWARD) AND/OR REPLACE WITH STEEL CABLE BANDS OF AT LEAST 1/4" WIDTH AT LEAST 14 INCH CENTER
Condition: Unknown
Due 15 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 6 December 1984 Resolved
REPLACE THE PLEXI GLASS COVER ON THE M.G. SET WIRING TERMINAL WITH STEEL COVER AND MAKE COVER SPLASH PROOF.
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Electrical
Issued 6 December 1984 Resolved
REMOVE THE FOLLOWING DEAD ENDED CABLES IN THE ER AND MAINDECK. A) ABOVE THE"STB BLOWER" AT THE FWD ER BHD LOWER LEVEL B) AT THE TOP OF FRESH WATER CONTROL UNIT #2 C) OBSOLETE CO2 ALARM ON STB MAINDECK ACCOMM. D) IN AFT STEERING (PORT SIDE)
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Construction/Loadline
Issued 6 December 1984 Resolved
REPAINT PLIMSOLL MARKS
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Accommodation/Occupational Safety
Issued 6 December 1984 Resolved
REPAIR OR REMOVE HANDRAILS ON VENT MAST MIDSHIPS.
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Deck/Cargo
Issued 6 December 1984 Resolved
PROVIDE DOCUMENTATION OF LOADLINE CERTIFICATION WITH CURRENT ENDORCEMENT.
Condition: Unknown
Due 22 February 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 6 December 1984 Resolved
REPAIR PINHOLE LEAK IN STARBOARD BOW
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Construction/Loadline
Issued 6 December 1984 Resolved
REPLACE THE FOLLOWING PORTLIGHTS: 5 IN MACHINERY SPACE SKYLIGHT, 1 IN GALLEY SKYLIGHT.
Condition: Unknown
Due 15 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 6 December 1984 Resolved
RELAG THE EXPOSED MAIN STEAM LINE IN THE AUXILIARY BOILER AND IT'S RECIRCULATING STEAM LINE (TO BOTTOM OF BOILER).
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Engineering
Issued 6 December 1984 Resolved
RELAG THE AUX. BOILER EXHAUST PIPING FROM THE BOILER'S COMBUSTION CHAMBER UP TO THE UPPER LEVEL OF THE ER (APPROX. 30 FT).
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Engineering
Issued 6 December 1984 Resolved
REPAIR PORT ENGINEROOM ENGINE ORDER TELEGRAPH SO IT MATCHES THE SAME COMMAND AS THE BRIDGE.
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Accommodation/Occupational Safety
Issued 6 December 1984 Resolved
REPAIR HOLE IN OVERHEAD OF CO2 ROOM BETWEEN #1 AND #2 TRANSVERSE UNDERDECK LONG'L AND THE 1ST AND 2ND LONG'L RIVETED JOINTS.
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Navigation
Issued 6 December 1984 Resolved
PROVIDE ADEQUATE CLEARANCE FOR THE OUTBOARD RED HANDLE ON THE STB HYDRAULIC PUMP WHERE IT HIS THE CROSSOVER PIPE.
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Construction/Loadline
Issued 6 December 1984 Resolved
RENEW DOGS AND GASKET IN THE AFT STEERING MAIN DECK HATCH.
Condition: Unknown
Due 15 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 6 December 1984 Resolved
RENEW COFFERDAM GOOSENECK AND PROVIDE A SCREEN AT THE PORT SIDE ACCOMMODATIONS MAIN WEATHER DECK.
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Fire Fighting
Issued 6 December 1984 Resolved
REMOVE ON STARBOARD MAIN DECK (WEATHER) ACCOMMODATIONS THE OBSOLETE CO2 PULL BOX AND ALARM AND ALL REFERENCES TO THEIR OPERATIONS.
Condition: Unknown
Due 15 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 6 December 1984 Resolved
PROVIDE ELECTRICAL SHOCK PROTECTION TO THE FOLLOWING EQUIPMENT: A) FWD BOSN'S LOCKER (ELECTRICAL WINDLASS MOTOR CONTROLLER (2)) B) CO2 ROOM- THE ELECTRICAL CONTRACTOR FOR THE STBD CAPSTAN
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Electrical
Issued 6 December 1984 Resolved
TEST EMERGENCY LIGHTING AND LABEL SAME.
Condition: Unknown
Due 15 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 6 December 1984 Resolved
REPLACE AIR PRESSURE GAGE AND RELIEF VALVE ON THE #3 AIR RECEIVER (FROM AFTTO FWD, IN THE ENGINE ROOM ON THE STBD SIDE). THE AIR RELIEF VALVE SHALL HAVE A HAND LIFTING DEVICE. BOTH DEVICES SHALL BE SUITABLE FOR THE SERVICEPRESSURE AND SET NO HIGHER THAN MAWP OF TANK (450 PSI).
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Engineering
Issued 6 December 1984 Resolved
REPLACE THE AIR PRESSURE RELIEF VALVE IN KIND AND SMALL PIPE NIPPLE TO WHICH IT IS ATTACHED TO THE FWD MOST OF 6 AIR PRESSURE VESSELS ON THE STBD SIDE OF THE ENGINE ROOM. UNTIL IT IS REPLACED THIS TANK SHALL BE OPENED TOTHE ATMOSPHERE AND SECURED FROM THE CHARGING AIR.
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Accommodation/Occupational Safety
Issued 6 December 1984 Resolved
INSTALL A RELIEF VALVE ON THE SANITARY HEAD TANK IN THE ENGINE ROOM (PORT SIDE AFT) OF PROPER SIZE FOR THE INTENDED SERVICE SET TO RELIEVE AT NO GREATER THAN THE MAWP OF THIS TANK.
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Construction/Loadline
Issued 6 December 1984 Resolved
GAGE AND SHOW BY CALCULATION THAT THE PORT TAILSHAFT BHD (OUTBOARD) IS OF ADEQUATE THICKNESS.
Condition: Unknown
Due 15 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 6 December 1984 Resolved
REMOVE THE BOTTOM L.O. SIGHT GLASS GAGE VALVE AND REPLACE WITH ONE THAT IS SELF-CLOSING (IN ENGINEROOM).
Condition: Unknown
Due 15 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 6 December 1984 Resolved
PROVIDE A BATTERY BOX COVER ON THE EMERGENCY GENERATOR START BATTERIES IN THE ENGINEROOM.
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.