MAURY USCG vessel records
← All vessels

ST MICHAEL

ST MICHAEL is a 1995 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 2016, most recently in May 2026, along with 36 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 29 May 2026.

Built
1995
Last inspected
29 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 May 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD2624
419782
Flag
UNITED STATES
Maury page id
psix-419782

Documentation record

Registered dimensions (L × B × D)65.0 ft × 23.0 ft × 6.0 ft
Registered tonnagegross 27 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALLEN MARINE TOURS INC · SITKA AK, UNITED STATES · built 1995
Hull materialAluminum
PropulsionJet Drive
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portSITKA, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Net Ton
27 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 37

29 May 2026 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8382233
5 November 2025 Hull Examination · Internal Structural Exam · Vessel Attendance
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8264290
20 July 2025 Damage Survey
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8190367
22 May 2025 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8141886
7 June 2024 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7929625
1 November 2023 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7818887
22 August 2023 Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7775026
21 July 2023 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7748642
24 April 2023 Deficiency Check · Internal Structural Exam · COI Inspection · Examination of Repairs · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7671409
1 March 2023 Liferaft Servicing
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7647789
22 April 2022 Liferaft Servicing
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7438009
20 April 2022 Liferaft Servicing
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7438020
18 February 2022 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7398441
16 June 2020 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6978713
16 December 2019 Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6874913
12 November 2019 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6854347
29 October 2019 Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6844209
11 September 2019 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6809750
1 July 2019 Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6732570
17 May 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6688871
27 November 2018 Hull Examination · Internal Structural Exam · Deadweight Survey
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6588353
25 October 2018 Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6569074
25 July 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6490798
6 July 2018 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6469854
22 June 2018 In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6455670
8 June 2018 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6441118
8 June 2018 Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6441360
21 May 2018 Examination of Repairs · Deficiency Check · Construction Oversight · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6421841
18 May 2018 Administrative Inspection · Deadweight Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6418130
9 November 2017 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6304554
29 September 2017 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6277969
24 July 2017 Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6221637
1 May 2017 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6136832
10 November 2016 Internal Structural Exam · Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6038662
4 October 2016 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6015262
3 May 2016 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5870864
19 April 2016 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5859818

Deficiency record · 36

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 June 2024 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant. Waterlight had incorrect batteries installed not IAW approval letter. 46 CFR 180.70
Action required: 10 - Deficiency Rectified
Resolved 7 June 2024
Resolution: Correct batteries were installed in floating marker light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2023 Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. Vessels ammeter and voltmeter were inoperable. 46 CFR 183.320(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2023
Resolution: Voltmeter and Ammeter tested SAT.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2023 Resolved
All electrical equipment and circuits must be clearly marked and identified. Galley electrical panel had several circuits that were improperly labeled. 46 CFR 183.220(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2023
Resolved 12 May 2023
Resolution: Circuits were properly labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Starboard engine room high water switch was not mounted in the bilge and the port engine room high water switch had a broken mount. Both were found operating properly. 46 CFR 182.530(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2023
Resolved 12 May 2023
Resolution: Both high water alarms were properly mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2023 Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers: (b) Each life jacket, must be marked in clearly legible block capital letters with the vessel's name. 05 child PFD's were found not properly marked with the vessel's name. 46 CFR 185.604(b)
Action required: 10 - Deficiency Rectified
Resolved 25 April 2023
Resolution: Corrected on the spot. Names were properly marked on all PFD's.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2023 Resolved
by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. On board fire buckets were not properly labeled. 46 CFR 181.610
Action required: 10 - Deficiency Rectified
Resolved 25 April 2023
Resolution: Corrected on the spot. Fire buckets were properly labeled.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 24 April 2023 Resolved
Inspection of ships subject to the Communications Act or the Safety Convention. A certification that the ship has passed an inspection must be entered into the ship's log by the inspecting tech. FCC Safety Radio Cert is expired 47 CFR 80.59(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2023
Resolved 12 May 2023
Resolution: FCC Safety Radio Certificate was renewed.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 8 March 2022 Resolved
Identified unfinished weld in way of collision bulkhead near inboard knuckle/chine. Make watertight.
Action required: 705 - Other - as specified
Resolved 2 September 2022
Resolution: Unfinished weld repaired SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 March 2022 Resolved
Identify wastage exceeding 25% in port/stbd void 2 tunnel plate. Crop and renew to good metal.
Action required: 705 - Other - as specified
Resolved 8 March 2022
Resolution: No wastage exceeding 25% identified.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 25 February 2022 Resolved
Identify wastage exceeding 25% in both engine room's bottom plate. Crop and renew to good metal.
Action required: 705 - Other - as specified
Resolved 2 September 2022
Resolution: Identified wastage exceeding 25% has been cropped out and renewed. NDT testing SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 February 2022 Resolved
Remove water in bilges of void #2 and #3. Clean and descale for re-inspection.
Action required: 705 - Other - as specified
Resolved 7 March 2022
Resolution: All sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 October 2019 Resolved
Complete fire drill, man overboard and sea trials to the satisfactory of an attending CG Marine Inspector prior to carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2022
Resolution: Vessel does not have a valid issued COI. Drills will be conducted at COI renewal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 October 2019 Resolved
Provide water light for ring buoy.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2019
Resolution: New light installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 October 2019 Resolved
Repair fuel leak on #1 MDE secondary fuel filter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2019
Resolution: Fuel leak corrected.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 October 2019 Resolved
Make permanent repairs to port side engine room exhaust ventilation guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2019
Resolution: Properly repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 October 2019 Resolved
Provide two hose clamps at all flex pipe connections for bilge pumping system. #2 MDE in port engine room missing several hose clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2019
Resolution: Clamps installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 29 October 2019 Resolved
Replace missing lagging on #1 MDE in port engine room exhaust piping in way of piping flange.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2019
Resolution: Installed.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 29 October 2019 Resolved
Prove proper operation of compass light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2019
Resolution: LIght repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 29 October 2019 Resolved
Replace cracked window in forward main cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2020
Resolution: Window replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 October 2019 Resolved
Properly secure D8 batter below helm area.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 October 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 October 2019 Resolved
Remove extra car battery below helm area.
Action required: 10 - Deficiency Rectified
Resolved 29 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2019 Resolved
Both port and starboard forward MDE have leaks from their charge air line between the turbo and charge air cooling box. Repair leaks and clean leaked fuel oil. Code 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2019
Resolved 24 September 2019
Resolution: Gaskets replaced and fuel oil cleaned.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 27 May 2018 Resolved
Develop procedures and conduct tests to demonstrate the FTP engine's alarms, shutdowns, and derate features.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2018
Resolved 22 June 2018
Resolution: Witnessed an operational test of newly installed engine's derating features.
Documentation › Certificates/Documents › Stability Letter
Issued 21 May 2018 Resolved
The vessel must maintain an up-to-date stability letter to account for changes in the weight and LCG. Following a main engine repower, the configuration of the vessel is not reflected in the current stability analysis.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2018
Resolved 25 July 2018
Resolution: Vessel underwent a stability review and was issued a new stability letter.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 21 May 2018 Resolved
Submit a Qualitative Failure Analysis for a "Loss of Power" to the Marine Safety Center for the main engine's electronic propulsion controls and conduct tests IAW approved procedures.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2018
Resolved 1 March 2022
Resolution: Received MSC approval letter for submitted QFA and DVTP's.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 September 2017 Resolved
Renew or repair stern light
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 May 2018
Resolution: Verified vessel's stern light was working properly.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 29 September 2017 Resolved
Provide proper amount of child size life jackets. Considering current compliment of 10 child size life jackets, total persons permitted aboard shall not exceed 100.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 9 November 2017
Resolution: Verified full compliment of child size PFD's were aboard.
Navigation › Piloting/Steering › Marine Charts
Issued 29 September 2017 Resolved
Provide current corrected nautical charts for area normally transited.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 22 June 2018
Resolution: Verified appropriate charts were aboard.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 29 September 2017 Resolved
Repair or renew port fuel vent flame screen.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 9 November 2017
Resolution: Verified installatin of the flame screen in the port fuel tank vent.
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 September 2017 Resolved
Conduct drills in Spring 2018
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 8 June 2018
Resolution: Conducted underway drills, all sat
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 September 2017 Resolved
Make AC raw water cooling line bulkhead penetration valve operable from the bulkhead deck or provide 1 valve on either side of the bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 9 November 2017
Resolution: Verified installation of a metallic valve on both sides of the transverse bulkhead.
Engineering › Bilge Water Management System › Piping
Issued 10 November 2016 Resolved
Identified a bilge piping softpatch just fwd of the stbd aft MDE bilge pump. Make permanent repairs to bilge piping.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 22 November 2016
Resolution: Bilge piping was renewed.
Electrical › Electrical Distribution System (service) › Conductor
Issued 10 November 2016 Resolved
Identified a dead ended wire in the vicinity of bilge pump in the #3 port void. Identify function and reconnect as necessary within an enclosure.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 22 November 2016
Resolution: Dead ended conductor was inadvertently pulled from the vessel 12 volt bilge pump. Conductor was reconnected with a butt splice and covered with a heat shrink. Determination was made by Sector Juneau this connections met the conditions of an enclosure.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 October 2016 Resolved
Drills required to be conducted in the spring of 2017.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 1 May 2017
Resolution: Witnessed fire, abandon ship, and man overboard drills.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 4 October 2016 Resolved
Label remote fuel oil shutoff valves showing purpose and directions of operations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 10 November 2016
Resolution: Verified proper labeling for remote F/O shutoff valves.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 October 2016 Resolved
Label forward main deck PFD storage locker.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 10 November 2016
Resolution: Verified proper labeling for PFD stowage.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.