Records from 1995 to 2026. Most recent: inspection, 29 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 66
29 May 2026
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8382233
5 November 2025
Hull Examination · Internal Structural Exam · Vessel Attendance
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8264290
20 July 2025
Damage Survey
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8190367
22 May 2025
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8141886
7 June 2024
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7929625
1 November 2023
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7818887
22 August 2023
Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7775026
21 July 2023
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7748642
24 April 2023
Deficiency Check · Internal Structural Exam · COI Inspection · Examination of Repairs · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7671409
1 March 2023
Liferaft Servicing
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7647789
22 April 2022
Liferaft Servicing
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7438009
20 April 2022
Liferaft Servicing
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7438020
18 February 2022
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7398441
16 June 2020
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6978713
16 December 2019
Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6874913
12 November 2019
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6854347
29 October 2019
Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6844209
11 September 2019
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6809750
1 July 2019
Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6732570
17 May 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6688871
27 November 2018
Hull Examination · Internal Structural Exam · Deadweight Survey
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6588353
25 October 2018
Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6569074
25 July 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6490798
6 July 2018
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6469854
22 June 2018
In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6455670
8 June 2018
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6441118
8 June 2018
Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6441360
21 May 2018
Examination of Repairs · Deficiency Check · Construction Oversight · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6421841
18 May 2018
Administrative Inspection · Deadweight Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6418130
9 November 2017
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6304554
29 September 2017
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6277969
24 July 2017
Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6221637
1 May 2017
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6136832
10 November 2016
Internal Structural Exam · Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6038662
4 October 2016
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6015262
3 May 2016
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5870864
19 April 2016
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5859818
15 October 2015
DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5746054
6 May 2014
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 4853446
16 September 2011
Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 4147199
22 July 2011
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 4090629
9 December 2010
COI Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3907698
19 March 2009
Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3436561
24 February 2009
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3423690
31 March 2008
Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3174993
10 May 2007
Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 2927252
9 January 2007
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2852947
2 May 2006
COI Inspection
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2639844
12 October 2005
Examination of Repairs · Deficiency Check
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2513251
6 May 2005
Annual Inspection
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2351347
2 November 2004
Internal Structural Exam · Hull Examination
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2234389
3 August 2004
Annual Inspection
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2198445
22 May 2003
Annual Inspection
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1799356
4 April 2003
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1772222
20 March 2002
Administrative Inspection · Annual Inspection · MARPOL Annex V Examination
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1490161
4 May 2001
MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1382243
9 May 2000
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1049941
4 May 2000
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1423367
26 May 1999
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 802680
28 April 1999
Re-Inspection · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1413522
24 February 1999
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1457629
11 February 1999
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 104504
15 May 1998
COI Inspection · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1395003
24 January 1997
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1383434
7 May 1996
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1407690
23 May 1995
Hull Examination · Initial Certification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1190174
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 June 2024
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant. Waterlight had incorrect batteries installed not IAW approval letter.
46 CFR 180.70
Action required: 10 - Deficiency Rectified
Resolved 7 June 2024
Resolution: Correct batteries were installed in floating marker light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2023
Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. Vessels ammeter and voltmeter were inoperable.
46 CFR 183.320(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2023
Resolution: Voltmeter and Ammeter tested SAT.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2023
Resolved
All electrical equipment and circuits must be clearly marked and identified. Galley electrical panel had several circuits that were improperly labeled.
46 CFR 183.220(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2023
Resolved 12 May 2023
Resolution: Circuits were properly labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2023
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Starboard engine room high water switch was not mounted in the bilge and the port engine room high water switch had a broken mount. Both were found operating properly.
46 CFR 182.530(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2023
Resolved 12 May 2023
Resolution: Both high water alarms were properly mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2023
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers: (b) Each life jacket, must be marked in clearly legible block capital letters with the vessel's name. 05 child PFD's were found not properly marked with the vessel's name.
46 CFR 185.604(b)
Action required: 10 - Deficiency Rectified
Resolved 25 April 2023
Resolution: Corrected on the spot. Names were properly marked on all PFD's.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2023
Resolved
by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. On board fire buckets were not properly labeled.
46 CFR 181.610
Action required: 10 - Deficiency Rectified
Resolved 25 April 2023
Resolution: Corrected on the spot. Fire buckets were properly labeled.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 24 April 2023
Resolved
Inspection of ships subject to the Communications Act or the Safety Convention. A certification that the ship has passed an inspection must be entered into the ship's log by the inspecting tech. FCC Safety Radio Cert is expired
47 CFR 80.59(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2023
Resolved 12 May 2023
Resolution: FCC Safety Radio Certificate was renewed.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 8 March 2022
Resolved
Identified unfinished weld in way of collision bulkhead near inboard knuckle/chine. Make watertight.
Action required: 705 - Other - as specified
Resolved 2 September 2022
Resolution: Unfinished weld repaired SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 March 2022
Resolved
Identify wastage exceeding 25% in port/stbd void 2 tunnel plate. Crop and renew to good metal.
Action required: 705 - Other - as specified
Resolved 8 March 2022
Resolution: No wastage exceeding 25% identified.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 25 February 2022
Resolved
Identify wastage exceeding 25% in both engine room's bottom plate. Crop and renew to good metal.
Action required: 705 - Other - as specified
Resolved 2 September 2022
Resolution: Identified wastage exceeding 25% has been cropped out and renewed. NDT testing SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 February 2022
Resolved
Remove water in bilges of void #2 and #3. Clean and descale for re-inspection.
Action required: 705 - Other - as specified
Resolved 7 March 2022
Resolution: All sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 October 2019
Resolved
Complete fire drill, man overboard and sea trials to the satisfactory of an attending CG Marine Inspector prior to carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2022
Resolution: Vessel does not have a valid issued COI. Drills will be conducted at COI renewal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 October 2019
Resolved
Provide water light for ring buoy.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2019
Resolution: New light installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 October 2019
Resolved
Repair fuel leak on #1 MDE secondary fuel filter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2019
Resolution: Fuel leak corrected.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 October 2019
Resolved
Make permanent repairs to port side engine room exhaust ventilation guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2019
Resolution: Properly repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 October 2019
Resolved
Provide two hose clamps at all flex pipe connections for bilge pumping system. #2 MDE in port engine room missing several hose clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2019
Resolution: Clamps installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 29 October 2019
Resolved
Replace missing lagging on #1 MDE in port engine room exhaust piping in way of piping flange.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2019
Resolution: Installed.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 29 October 2019
Resolved
Prove proper operation of compass light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2019
Resolution: LIght repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 29 October 2019
Resolved
Replace cracked window in forward main cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2020
Resolution: Window replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 October 2019
Resolved
Properly secure D8 batter below helm area.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 October 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 October 2019
Resolved
Remove extra car battery below helm area.
Action required: 10 - Deficiency Rectified
Resolved 29 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2019
Resolved
Both port and starboard forward MDE have leaks from their charge air line between the turbo and charge air cooling box. Repair leaks and clean leaked fuel oil. Code 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2019
Resolved 24 September 2019
Resolution: Gaskets replaced and fuel oil cleaned.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 27 May 2018
Resolved
Develop procedures and conduct tests to demonstrate the FTP engine's alarms, shutdowns, and derate features.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2018
Resolved 22 June 2018
Resolution: Witnessed an operational test of newly installed engine's derating features.
Documentation › Certificates/Documents › Stability Letter
Issued 21 May 2018
Resolved
The vessel must maintain an up-to-date stability letter to account for changes in the weight and LCG. Following a main engine repower, the configuration of the vessel is not reflected in the current stability analysis.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2018
Resolved 25 July 2018
Resolution: Vessel underwent a stability review and was issued a new stability letter.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 21 May 2018
Resolved
Submit a Qualitative Failure Analysis for a "Loss of Power" to the Marine Safety Center for the main engine's electronic propulsion controls and conduct tests IAW approved procedures.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2018
Resolved 1 March 2022
Resolution: Received MSC approval letter for submitted QFA and DVTP's.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 September 2017
Resolved
Renew or repair stern light
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 May 2018
Resolution: Verified vessel's stern light was working properly.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 29 September 2017
Resolved
Provide proper amount of child size life jackets. Considering current compliment of 10 child size life jackets, total persons permitted aboard shall not exceed 100.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 9 November 2017
Resolution: Verified full compliment of child size PFD's were aboard.
Navigation › Piloting/Steering › Marine Charts
Issued 29 September 2017
Resolved
Provide current corrected nautical charts for area normally transited.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 22 June 2018
Resolution: Verified appropriate charts were aboard.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 29 September 2017
Resolved
Repair or renew port fuel vent flame screen.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 9 November 2017
Resolution: Verified installatin of the flame screen in the port fuel tank vent.
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 September 2017
Resolved
Conduct drills in Spring 2018
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 8 June 2018
Resolution: Conducted underway drills, all sat
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 September 2017
Resolved
Make AC raw water cooling line bulkhead penetration valve operable from the bulkhead deck or provide 1 valve on either side of the bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 9 November 2017
Resolution: Verified installation of a metallic valve on both sides of the transverse bulkhead.
Engineering › Bilge Water Management System › Piping
Issued 10 November 2016
Resolved
Identified a bilge piping softpatch just fwd of the stbd aft MDE bilge pump. Make permanent repairs to bilge piping.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 22 November 2016
Resolution: Bilge piping was renewed.
Electrical › Electrical Distribution System (service) › Conductor
Issued 10 November 2016
Resolved
Identified a dead ended wire in the vicinity of bilge pump in the #3 port void. Identify function and reconnect as necessary within an enclosure.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 22 November 2016
Resolution: Dead ended conductor was inadvertently pulled from the vessel 12 volt bilge pump. Conductor was reconnected with a butt splice and covered with a heat shrink. Determination was made by Sector Juneau this connections met the conditions of an enclosure.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 October 2016
Resolved
Drills required to be conducted in the spring of 2017.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 1 May 2017
Resolution: Witnessed fire, abandon ship, and man overboard drills.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 4 October 2016
Resolved
Label remote fuel oil shutoff valves showing purpose and directions of operations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 10 November 2016
Resolution: Verified proper labeling for remote F/O shutoff valves.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 October 2016
Resolved
Label forward main deck PFD storage locker.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 10 November 2016
Resolution: Verified proper labeling for PFD stowage.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 15 October 2015
Resolved
Provide a current copy of Radiotelephony Certificate. 47 CFR 13
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 3 May 2016
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 October 2015
Resolved
Conduct Drills (MOB, Fire, Abandon Ship) 46CFR185.520
Drills will be conducted in the spring prior to start of the 2016 season
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 3 May 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 October 2015
Resolved
Prove proper operation of stbd laz bilge alarm. 46CFR182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 19 April 2016
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 15 October 2015
Resolved
Prove proper operation of Stbd FWD exhaust temperature gauge. 46CFR182.410(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 3 May 2016
Engineering › Generator (propulsion-electric) › Receptacle
Issued 15 October 2015
Resolved
Repare/replace stbd generator exhaust flexible hose. 46CFR182.720
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 19 April 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 May 2007
Resolved
Prove proper operation of the stern light.
Due 10 June 2007
Resolved 10 May 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2007
Resolved
Remove dead-ended wiring in aft stbd engine room possibly identified as old waterflow alarm.
Due 10 June 2007
Resolved 15 May 2007
Stability › Watertight Integrity › General
Issued 2 May 2006
Resolved
Provide watertight hatches in main deck in lieu of 6" coaming in accordance with [name withheld] letter of 2004.
Due 2 June 2006
Resolved 21 November 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2006
Resolved
Make repairs to chaffed electrical wires on engine harness of aft engine in the stbd engine room.
Due 3 June 2006
Resolved 21 November 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2006
Resolved
Remove dead ended wires marked "port" & "stbd" beneath operator's console in pilothouse. Or, properly terminate and place in "J" box.
Due 2 June 2006
Resolved 21 November 2006
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 2 May 2006
Resolved
Make repairs to mounting tab for walkway/rotating equipment guard for intermediate shaft in stbd engine room.
Due 2 June 2006
Resolved 21 November 2006
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 6 May 2005
Resolved
Remove vent for Marine Sanitation Device where it is connected to overboard discharge. Run vent properly up through deck and provide flame screen. As installed vent is designed to allow overflow to freely discharge overboard.
Due 6 June 2005
Resolved 15 November 2005
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 6 May 2005
Resolved
Make repairs to mount for heat detector that is hanging by it's wires in the stbd engine room.
Due 6 June 2005
Resolved 13 November 2005
Engineering › Bilge Water Management System › Pump
Issued 6 May 2005
Resolved
Repair Rule pump in stbd engine room. It is out of it's mount and disconnected from the hose.
Due 6 June 2005
Resolved 15 November 2005
Construction/Loadline › Hull › Hull Plating
Issued 6 May 2005
Resolved
Repair hull plate on the cross deck on the port side of the generator where there are two holes drilled.
Due 6 June 2005
Resolved 15 November 2005
Construction/Loadline › Structures › Deck Plating
Issued 2 November 2004
Resolved
Make repairs to main deck on port side where cracked approx. 1.5 inches and displaced. Area is directly above first frame aft of collision bulkhead.
Action required: 705 - Other - as specified
Due 2 December 2004
Resolved 26 November 2004
Construction/Loadline › Hull › Hull Plating
Issued 2 November 2004
Resolved
Remove fiberglass insulation located in "tunnel" between second voids due to water logged and presence of corrosion. Clean area for examination to determine if renewal is required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2004
Resolved 15 November 2004
Construction/Loadline › Hull › Weld
Issued 2 November 2004
Resolved
Pickup missing weld at fwd end of fuel tank space on port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 December 2004
Resolved 15 November 2004
Construction/Loadline › Hull › Hull Plating
Issued 2 November 2004
Resolved
Remove insulation in way of Marine Sanitation Device in Port Jet room. Clean area to determine extent of exfoliation corrosion and area to be cropped and renewed.
Action required: 705 - Other - as specified
Due 2 December 2004
Resolved 15 November 2004
Construction/Loadline › Penetrations › Weld
Issued 2 November 2004
Resolved
Crop and renew 4 areas in both port and stbd jet rooms on transom where 2" holes were cut in wrong places, rewelded improperly and now are failing or corroded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2004
Resolved 26 November 2004
Construction/Loadline › Structures › Door
Issued 22 May 2003
Resolved
Provide a 3" coaming in the accommodations doors and the doors leading to the engine rooms, in accordance with 46CFR Table 171.124 LEGACY COMPONENT DESC: Door
Due 22 June 2003
Resolved 3 August 2004
Construction/Loadline › Structures
Issued 4 April 2003
Resolved
Plug weld 4 holes in Jet room forward watertight bulkhead. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 4 May 2003
Resolved 11 April 2003
Resolution: Holes plug welded.
Engineering › Bilge Water Management System
Issued 4 April 2003
Resolved
Provide a reach rod for the bilge system valves at the collision bulkhead on both the port and starboard sides. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 May 2003
Resolved 24 April 2003
Resolution: Reach rod installed
Engineering › Bilge Water Management System
Issued 4 April 2003
Resolved
Provide a double clamp on the starboard bilge pump flexible line to the manifold. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 4 May 2003
Resolved 24 April 2003
Resolution: Double clamp provided
Construction/Loadline › Structures
Issued 4 April 2003
Resolved
Repair water tight integrity where lost in starboard engine room, inboard, on forward transverse watertight bulkhead, due to removal of electrical wiring and remaining penetration closed with masking tape. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 4 May 2003
Resolved 24 April 2003
Resolution: Hole properly sealed
Construction/Loadline › Hull
Issued 4 April 2003
Resolved
Repair "chine plates" on both sides of each bow where welds are fracturing. Provide drydocking plugs to air test inaccessible voids to 2psi at each drydock. Provide proposal for suitable modification for hull forms which does not include hidden voids. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2003
Resolved 24 April 2003
Resolution: Voids tested, cracks v & rewelded
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 March 2002
Resolved
COD was missing, but a MISLE check showed it was current. A new one was received in the mail.
Condition: Unknown
Due 20 March 2002
Resolved 20 March 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 20 March 2002
Resolved
The Starboard aft main engine had an exhaust leak into the engine room. The leak was fixed during the inspection.
Condition: Unknown
Due 20 March 2002
Resolved 20 March 2002
Fire Fighting › Nozzles › Type
Issued 20 March 2002
Resolved
The fire hose had a plastic nozzle. It was replaced with a suitable metal nozzle during the inspection.
Condition: Unknown
Due 20 March 2002
Resolved 20 March 2002
Fire Fighting
Issued 4 May 2000
Resolved
Covered metal trash containers shall be provided in lounge areas in accordance with 46 CFR 177.30-7.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Navigation
Issued 4 May 2000
Resolved
Repair or replace vessels horn/whistle. A portable sound producing device shall be carried until the vessels has an operable whistle.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Lifesaving
Issued 4 May 2000
Resolved
Vessel may not carry passengers until the inflatable buoyant apparatus are installed in accordance with 46 CFR 180.10-20.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Lifesaving
Issued 28 April 1999
Resolved
PROVIDE DOCUMENTARY EVIDENCE LIFESAVING EQUIPMENT IS REGULARLY INSPECTED.
Condition: Unknown
Due 28 May 1999
Resolved 26 May 1999
Lifesaving
Issued 28 April 1999
Resolved
DEMONSTRATE SATISFACTORY EMERGENCY DRILLS WITH SEASONAL CREW.
Condition: Unknown
Due 28 May 1999
Resolved 26 May 1999
Lifesaving
Issued 28 April 1999
Resolved
ENSURE FIRST AID KIT IS COMPLETE AND CONTAINS NO EXPIRED MEDICINES.
Condition: Unknown
Due 28 May 1999
Resolved 26 May 1999
Construction/Loadline
Issued 24 February 1999
Resolved
Submit proposal to repair casualty damage to superstructure in the bow and rail area.(46CFR176.700)
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Accommodation/Occupational Safety
Issued 24 February 1999
Resolved
Install bulwarks or 4 inch rail courses below the rail in all passenger accessible locations as required by 46CFR177.900(g)(1). No passengers may be carried on the upper deck until this is corrected.
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Engineering
Issued 24 February 1999
Resolved
Properly ground fuel tanks to fuel fill pipe. Fill pipe is connected to fuel tank with a flexable rubber hose. Proper grounding is required to prevent a static discharge.(46CFR182.445)
Condition: Unknown
Due 24 March 1999
Resolved 18 March 1999
Engineering
Issued 24 February 1999
Resolved
Repair or adjust fuel tank shut offs on port and starboard tanks. _x001C_ (46CFR182.455(b)(4))
Condition: Unknown
Due 24 March 1999
Resolved 18 March 1999
Navigation
Issued 24 February 1999
Resolved
Replace the hydraulic hose on the port hulls inboard jet drive.(46CFR182.100)
Condition: Unknown
Due 24 March 1999
Resolved 18 March 1999
Electrical
Issued 24 February 1999
Resolved
Remove all dead end wire runs in the port and starboard jet rooms.(46CFR183.200)
Condition: Unknown
Due 24 March 1999
Resolved 18 March 1999
Construction/Loadline
Issued 24 February 1999
Resolved
Repair cracked welds in Exhaust box covers on both hulls in the tunnel. Both had cracks at connection points to hull. Reinforce the forward area with a continuous weld to prevent reoccurrences.(46CFR176.700)
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Navigation
Issued 24 February 1999
Resolved
Repair or replace damaged steering control transmitter rod in starboard jetroom. This linkage controls both jets. (46CFR182.610)
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Construction/Loadline
Issued 24 February 1999
Resolved
Place two hose clamps on the end of each hose connected to thru hull fittings below the waterline.(46CFR182.410(d)(1))
Condition: Unknown
Due 24 March 1999
Resolved 18 March 1999
Navigation
Issued 15 May 1998
Resolved
CALCULATE MAGNETIC DEVIATION FOR NEW MAGNETIC COMPASS AND POST DEVIATION TABLE.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Navigation
Issued 15 May 1998
Resolved
PROVE OPERATION OF COMPASS LIGHT PRIOR TO NIGHT-TIME OPERATION.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Documentation
Issued 15 May 1998
Resolved
PROVIDE FCC RADIO OPERATOR'S LICENSE FOR MASTER.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Lifesaving
Issued 15 May 1998
Resolved
CONDUCT AND LOG WEEKLY INSPECTION OF INFLATABLE BUOYANT APPARATUSES.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Lifesaving
Issued 15 May 1998
Resolved
PROVIDE ONE ADDITIONAL CHILD'S LIFE JACKET; VESSEL MAY CARRY NO CHILDREN FOR WHICH A CHILD'S LIFE JACKET IS NOT PROVIDED.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998