MAURY USCG vessel records Sign in
← All vessels

WHEN AND IF

WHEN AND IF is a 1939 passenger vessel (inspected). The Coast Guard has recorded 100 inspections since 1985, most recently in July 2026, along with 63 deficiencies and 1 casualty investigation in 2020.

Records from 1985 to 2026. Most recent: inspection, 3 July 2026.

Built
1939
Last inspected
3 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI8019
Flag
UNITED STATES
369018000
Maury page id
psix-41993

Inspections, by type

…with no type recorded6
Years with a record 35 calendar years (1985–2026)
The 100 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.5 ft × 15.0 ft × 8.0 ft
Registered tonnagegross 30 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderF.F. PENDLETON · WISCASSET, ME, UNITED STATES · built 1939
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 21 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR3990MMSI 369018000 · active · compulsorily equipped · granted 27 August 2026, expires 27 August 2036
WDI8019MMSI 369018000 · expired · compulsorily equipped · granted 17 May 2016, cancelled 27 June 2026
WDD2125MMSI 367047000 · expired · compulsorily equipped · granted 3 May 2006, cancelled 9 July 2016
WCS2400MMSI 368245000 · expired · compulsorily equipped · granted 22 April 2005, cancelled 8 August 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 100

3 July 2026 Attraction Vessel Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8430510
19 May 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8372245
15 August 2025 In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8212594
31 July 2025 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8199390
10 July 2025 Administrative Inspection · Attraction Vessel Exam · In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8182903
30 April 2025 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8113766
19 November 2024 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8036531
21 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7915839
24 January 2024 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7853776
5 October 2023 In-Service Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7804199
18 May 2023 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7686832
28 April 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7676019
13 April 2023 Attraction Vessel Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7667437
8 March 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7647438
1 November 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7586457
16 June 2022 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7478647
12 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7445159
27 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7193361
29 November 2020 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7104201
12 November 2020 Drydock Exam · Internal Structural Exam · In-Service Inspection · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7094088
15 June 2020 Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6978030
13 May 2020 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6944908
18 November 2019 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6860793
14 June 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6705825
24 January 2019 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6617170
18 October 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6563557
28 September 2018 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6557705
6 June 2018 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6436111
23 May 2018 Administrative Inspection · Attraction Vessel Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6394969
7 May 2018 Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6402302
19 April 2018 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6398230
8 March 2018 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6368306
8 November 2017 Administrative Inspection · In-Service Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6323881
16 June 2017 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6180449
1 May 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6134637
23 March 2017 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6119163
18 January 2017 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6072652
18 January 2017 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6072695
14 September 2016 Attraction Vessel Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6000839
7 September 2016 Administrative Inspection · Attraction Vessel Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6004508
2 September 2016 Attraction Vessel Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5990748
26 July 2016 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5960190
14 July 2016 Attraction Vessel Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5953287
6 July 2016 Administrative Inspection · Attraction Vessel Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5931657
3 May 2016 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5867046
22 March 2016 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5838321
8 February 2016 Administrative Inspection · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5810324
26 January 2016 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5803449
3 December 2015 Administrative Inspection · Drydock Exam · In-Service Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5774509
13 November 2015 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5762905
11 August 2015 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5212777
12 June 2014 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4886632
12 June 2014 In-Service Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4886635
27 July 2009 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3547224
5 August 2008 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3213756
24 January 2008 Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3135559
14 September 2007 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3057767
28 June 2007 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2976222
16 May 2007 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2939271
11 October 2006 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2798593
26 June 2006 MARPOL Annex V Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2693403
9 May 2006 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2650715
9 November 2005 Administrative Inspection
Administrative · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2531541
16 May 2005 Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2347992
28 July 2004 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2147944
3 June 2004 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2088334
17 July 2003 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1846856
17 June 2003 Hull Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1820035
5 September 2002 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1671232
18 June 2002 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1632014
26 June 2001 Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1415638
6 July 2000 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1052002
20 July 1999 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 773765
23 June 1999 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1082209
8 July 1998 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1127462
30 July 1997 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 778508
30 May 1997 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1110020
17 September 1996 Drydock Extension
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1136935
15 July 1996 Deficiency Check · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1090140
7 July 1995 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1182645
22 June 1995 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 872841
15 December 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 831469
9 October 1990 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 904015
1 June 1990 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 925652
8 May 1990 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 917474
16 April 1990 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1238107
27 April 1989 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1352452
11 April 1989 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 895426
19 April 1988 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1197368
7 April 1988 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1199327
24 November 1987 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1333580
25 September 1987 Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1319027
10 July 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1327614
1 May 1987 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1014238
29 April 1987 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1320273
17 April 1987 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1005069
30 May 1986 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 987859
18 April 1986 Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1000110
20 September 1985 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1298061
17 May 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 981537

Deficiency record · 63

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2026 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 29 June 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2026 Resolved
Mark each fire bucket with the words "FIRE BUCKET" in contrasting color.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 2 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 August 2025 Resolved
Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q and Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q or Twelve hand red flares. MI discovered six expired hand red flares. 46 CFR 180.68
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2025
Resolved 19 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2025 Resolved
Install a battery box cover on the battery bank in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 14 May 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 April 2025 Resolved
Install or provide a cover to secure the small ventilation hole between the engine room and the doghouse.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 14 May 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 April 2025 Resolved
Provide a waste receptacle constructed of non-combustible material in the vessel's main cabin space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 14 May 2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 May 2024 Resolved
Vessel's hydrostatic release for the Cat 1 EPIRB is expired. Provide and mark a new hydrostatic release prior to operating beyond 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 21 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2024 Resolved
Install a cover on the engine room battery installation to protect it against falling objects.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 May 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 May 2024 Resolved
Log EPIRB tests monthly.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 May 2022 Resolved
The battery in the vessel's FCC Type Accepted Category 1, 406 MHz EPIRB is expired. Provide proof of the current EPIRB properly serviced with a new battery installed or purchase a new Category 1, 406 MHz EPIRB and show proof of registration prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2022
Resolution: Vessel rep purchased, registered, and installed a new Category 1 406 MHz EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 May 2022 Resolved
Vessel has four hand red flare distress signals. Provide eight additional hand red flare distress signals (or two red and six orange distress signals) prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2022
Resolution: Vessel rep purchased 8 additional hand red flare distress signals.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 May 2022 Resolved
Vessel's Inflatable Buoyant Apparatus (IBA) is off the vessel for servicing. Provide proof of servicing and properly install the IBA prior to operating beyond three miles from shore.
Action required: 705 - Other - as specified
Resolved 31 May 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 May 2022 Resolved
Properly document fire fighting drills and training to include the date of the training and and a general description of the drill scenario.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 May 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 May 2022 Resolved
Provide the following information for the vessel's sail rigging Preventative Maintenance Plan: -General description of the sailing vessel and type of rig. -An inventory of all major rigging components with the date of install and a replacement schedule.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 May 2021 Resolved
The battery in the ring life buoy's floating waterlight expired 10/2020. The waterlight is operational, but the battery must be replaced within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2021 Resolved
Vessel has 30 adult life jackets on board and is limited to carrying 27 passengers and 30 total people until an additional 5 adult life jackets are provided. Provide life jackets within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 November 2020 Resolved
Water is weeping out of a 2’ section of caulking on the port side aft, between the A and B strakes. Remove caulking in the area and determine the cause of the weeping.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 May 2020 Resolved
Vessel lacks required overboard protection for excursion vessel in way of the outboard bench seating port and starboard along with the port and starboard areas aft of the aft stay to the operating station. Install adequate protection (no more than 4" gapped)in above mentioned areas to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2020
Resolved 15 June 2020
Resolution: Operator installed dyneema line in the gaps between the existing rails
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2019 Resolved
Three turnbuckles were found to have excessive bending due to the strain on the load path of the rigging. See Pictures.
Action required: 10 - Deficiency Rectified
Due 18 November 2019
Resolved 18 November 2019
Resolution: Owner Purchased new Turnbuckles on the spot.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2019 Resolved
Goblin Striker has a crack. Propose Repair prior to credit unstepping.
Action required: 705 - Other - as specified
Due 25 November 2019
Resolved 2 December 2019
Resolution: crack found to be imperfection from casting process and does not comprimise the safety of the rigging.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2019 Resolved
Toggle pin too small for chainplate/turnbuckle in which it is fitted. Replace pin to minimize play allowed.
Action required: 705 - Other - as specified
Due 25 November 2019
Resolved 2 December 2019
Resolution: Pin replaced with appropriately sized toggle pin.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2019 Resolved
Battery connections (terminal post) must be protected from falling objects and short-circuiting or arcing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 June 2019 Resolved
Replace SOLAS tape on 01 Adult PFD and Ring Buoys.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 June 2019 Resolved
Provide a total of 12 red hand held flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 July 2019
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 7 May 2018 Resolved
Resecure IBA to vessel. Vessel is restricted to 3nm.
Action required: 705 - Other - as specified
Due 12 May 2018
Resolved 14 May 2018
Resolution: IBA serviced and installed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 May 2018 Resolved
Provide valid FCC safety certificate.
Action required: 705 - Other - as specified
Due 12 May 2018
Resolved 14 May 2018
Resolution: New FCC safety certificate onboard.
Sail Rigging › Spars › Boom and Gooseneck Fitting
Issued 8 November 2017 Resolved
Make repairs to bobstay tang on cranse iron.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2017
Resolution: Repaired bobstay tang.
Construction/Loadline › Hull › Hull Plating
Issued 8 November 2017 Resolved
Vessel must be dry-docked and fasteners pulled no later than 5 years from last time fasteners were pulled.
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 18 October 2018
Resolution: Sector Boston conducted Credit Hull Exam and Fastener Removal/Examination.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 May 2017 Resolved
Provide bilge high level alarm for collision bulkhead, provide audible and visual indicator at operating station.
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 19 April 2018
Resolution: Tested sat. bilge alarm
Sail Rigging › Stays/Shrouds › Wires
Issued 1 May 2017 Resolved
Provide report of standing rigging installment date.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 19 April 2018
Resolution: Vessel Captain provided report of standing rigging installment date
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 1 May 2017 Resolved
Install IBA in accordance with COI. Vessel limited to 3 miles.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 12 May 2017
Resolution: IBA serviced and properly installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 May 2017 Resolved
Provide first aid kit IAW 46CFR160.041
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 19 April 2018
Resolution: Witnessed first aid kit is onboard.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 May 2017 Resolved
Provide GPS input for VHF radio.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 19 April 2018
Resolution: Verified GPS input for VHF radio.
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 May 2017 Resolved
Renew/repair leak in cooling system.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 12 May 2017
Resolution: Leak repaired with welder.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 May 2017 Resolved
Provide plans to OCMI for deck courses (4") prior to installation.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 15 May 2017
Resolution: Proposal was emailed, approved proposal.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 1 May 2017 Resolved
Provide means to make collision bulkhead watertight, install gasket on hatch.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 12 May 2017
Resolution: Gasket installed.
Communications › Alarms/Indicators › High Water Alarm
Issued 3 May 2016 Resolved
Make visual indicator on aft high water alarm operable.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: Vessel proved proper operation of visual indicator on aft high water alarm.
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 May 2016 Resolved
Make visual indicator on forward automatic bilge pump operable.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: Vessel proved proper operation of visual indicator on forward automatic bilge pump.
Documentation › Certificates/Documents › FCC SSL
Issued 3 May 2016 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: Vessel provided valid FCC SSL.
Communications › Radio Communications › VHF Radiotelephone
Issued 3 May 2016 Resolved
Program MMSI number from FCC SSL into Digital Select Calling VHF Radio.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: Vessel programed MMSI number into DSC VHF Radio.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 December 2015 Resolved
Separate child size and adult life jackets and relable storage lockers as appropriate.
Action required: 705 - Other - as specified
Due 11 January 2016
Resolved 11 January 2016
Resolution: Vessel separated child size life jackets from adult life jackets by placing a divider in deck storage locker. Vessel also relabled life jacket storage lockers throughout with correct number and type of life jacket stored in each.
Stability › Watertight Integrity › General
Issued 13 November 2015 Resolved
Vessel is overdue for a required hull exam. Vessel will be changing from a freshwater route to a saltwater route therefore vessel is required to be drydocked every two years vs. five years. Hull exam shall be completed to the satisfaction of a CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2015
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 18 July 2007 Resolved
Provide an approved fire detection system or automatic activation capability for fixed CO2 system in Engine Room. Until completed, provide a smoke detector meeting UL Standard 217 as a temporary equivalent measure of safety.
Action required: 705 - Other - as specified
Due 31 August 2007
Resolved 14 September 2007
Resolution: Completed this date.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 June 2007 Resolved
Provide 60 feet of floating, UV-resistent line with a minimum diameter of 5/16 inch for the ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2007
Resolved 5 July 2007
Resolution: [name withheld] examined new line for ring buoy. All sat.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 28 June 2007 Resolved
Renew retro-tape on 6 adult PFD's.
Due 6 July 2007
Resolved 5 July 2007
Resolution: [name withheld] examined renewed retro-tape. All sat.
Engineering › Bilge Water Management System › Pump
Issued 28 June 2007 Resolved
Prove proper operation of fwd (manual) bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2007
Resolved 5 July 2007
Resolution: [name withheld] witnessed test of fwd bilge pump. All sat.
Fire Fighting › Ventilation Systems › Ducts
Issued 28 June 2007 Resolved
Provide suitable vent closure devices in case of fire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2007
Resolved 5 July 2007
Resolution: [name withheld] examined renewed vent closure devices. All sat.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 28 June 2007 Resolved
Provide a plan for installation of an approved fire detection system or automatic activation for the fixed carbon dioxide fire extinguishing system for the engine room.
Due 13 July 2007
Resolved 18 July 2007
Resolution: Master confirmed he has contacted with Firex, Inc. to install the approved Ansul Check Fire detection system.
Engineering › Bilge Water Management System › Pump
Issued 28 June 2007 Resolved
Tighten drive belt on the PTO bilge/fire combo pump.
Due 6 July 2007
Resolved 5 July 2007
Resolution: [name withheld] examined drive belt on PTO pump. All sat.
Lifesaving › Lifebuoys › Serviceable
Issued 11 October 2006 Resolved
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2006
Resolved 23 August 2007
Resolution: Closed because def is showing up in our reports. Since def is on vessel from another zone and has been inspected since with inspection reults indicating it was good.
Communications › Radio Communications › EPIRB
Issued 3 June 2004 Resolved
REPLACE EPIRB BATTERY. VESSEL RESTRICTED TO NOT MORE THAN 3 MILES FROM SHORE UNTIL REPLACED.
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 28 July 2004
Resolution: VESSEL REP REPORTS BATTERY REPLACED.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 June 2004 Resolved
INSTALL METALLIC CLIP TO ATTACH FLOAT LIGHT TO LIFE RING.
Action required: 705 - Other - as specified
Due 18 June 2004
Resolved 28 July 2004
Resolution: VESSEL REP REPORTS CLIP INSTALLED.
Communications › Alarms/Indicators
Issued 18 June 2002 Resolved
MAKE BILGE ALARM IN ENGINEROOM OPERATIONAL AND INSTALL OPERATING LIGHTS FOR AUTOMATIC BILGE PUMPS AS REQUIRED BY 46 CFR 182.530. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 5 September 2002
Resolution: BILGE ALARM AND LIGHTS INSTALLED.
Communications › Radio Communications › EPIRB
Issued 18 June 2002 Resolved
PROVIDE PROOF OF CURRENT EPIRB REGISTRATION WITH NOAA.
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 18 June 2002
Resolution: FAXED TO NOAA AND RECEIVED CONFIRMATION.
Documentation › Markings/Placards
Issued 18 June 2002 Resolved
PROVIDE NEW LABELS FOR THE EMERGENCY F/O SHUTOFFS AS REQUIRED BY 46 CFR 185.608 WITH 1" LETTERS AND DIRECTION OF OPERATION.
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 5 September 2002
Resolution: LABELS INSTALLED.
Lifesaving
Issued 26 June 2001 Resolved
VESSEL IS LIMITED TO NOT MORE THAN THREE (3) MILES FROM SHORE UNTIL INFLATABLE LIFERAFT IS REPLACED AS REQUIRED BY 46 CFR 180.205(E)(2).
Condition: Unknown
Due 18 July 2001
Resolved 18 July 2001
Lifesaving
Issued 15 July 1996 Resolved
PROVIDE PELICAN HOOK FOR QUICK RELEASE OF LIFERAFT.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Documentation
Issued 15 July 1996 Resolved
PROVIDE COPY OF FCC OPERATOR'S LICENSE.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Construction/Loadline
Issued 15 July 1996 Resolved
RENEW STARBOARD COCKPIT SCUPPER FLEXIBLE HOSE.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Accommodation/Occupational Safety
Issued 8 May 1990 Resolved
INSTALL USCG APPROVED MARINE SANITATION DEVICE FOR BOTH HEADS, WHICH COMPLYWITH 33 CFR 159. HEADS MAY NOT BE USED INSIDE TERRITORIAL WATERS OF THE U.S., AND PASSENGERS MAY NOT BE CARRIED ON TRIPS OVER THIRTY (30) MINUTES IN DURATION UNTIL THIS REQUIREMENT IS COMPLETE.
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Lifesaving
Issued 8 May 1990 Resolved
MARK ALL LIFE PRESERVER STOWAGE IN ACCORDANCE WITH 46 CFR 180.25-15(B).
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Fire Fighting
Issued 8 May 1990 Resolved
SERVICE FIXED CO2 SYSTEM, INCLUDING WEIGHING BOTTLE AND TESTING LINES AND RELEASE.
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990

Casualty record · 1

29 November 2020Routine · role: Involved in a Marine Casualty · activity 7104201
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.