Records from 2016 to 2022. Most recent: inspection, 7 December 2022.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 April 2022
No resolution recorded
Vessel must submit plans for the installation and use of monitoring devices to ensure wakefulness of the required night watch IAW 87 Federal Register 73160.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 April 2022
No resolution recorded
Vessel must submit evidence of developed safe handling procedures for the operation and storage of potentially hazardous items such as rechargeable batteries IAW 87 Federal Register 73160.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 April 2022
No resolution recorded
Vessel must submit evidence of marine firefighting training programs to improve crewmember training and proficiency, including egress training for each member of the crew.
Vessel is not allowed to operate with overnight accommodations or on a Coastwise / Oceans route until above deficiencies are rectified. IAW 87 Federal Register 73160
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 December 2020
No resolution recorded
The life ring needs to be replaced or serviced, because lines are frayed and ring is very worn in certain spots. 46CFR176.808(b)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 December 2020
No resolution recorded
The hydrostatic release on the lifefloat needs to be removed, because it is improperly installed. 46CFR176.808(b)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2020
No resolution recorded
Chemical testing program is missing New policy statement, Signed statement of understanding, New Swabs. 46CFR16.230
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 December 2020
No resolution recorded
DSC is not installed on VHF radio. 47 CFR 80.1085(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 December 2020
No resolution recorded
Bilge alarm locations are not labeled in the pilot house. 46CFR182.100
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 December 2020
No resolution recorded
The life jackets that are stowed in forward berthing are not stored in a convenient place. 46CFR180.78
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 December 2020
No resolution recorded
Bilge high level alarm in engine room is inoperable and needs to be operating.46CFR182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 9 December 2020
No resolution recorded
No FCC operators permit present on board, operator needs permit. 47CFR13
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 9 December 2020
No resolution recorded
Forward most compartment has battery present and does not have ventilation. Ventilation needs to be present.46CFR183.350(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 9 December 2020
No resolution recorded
Forward most compartment has a light that is not intrinsically safe. 46CFR183.200(d)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 December 2020
No resolution recorded
Fireboy sytem has not been serviced and needs to be serviced.46CFR176.810(b)(1)(iv)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 December 2020
No resolution recorded
Generator needs guards where the belts are. 46CFR182.100
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 December 2020
No resolution recorded
Battery charger has loose terminal wires and needs safety cap.46CFR183.340
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 December 2020
No resolution recorded
Fire extinguishers need to be serviced. 46CFR176.810(b)(1)(iv)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 December 2020
No resolution recorded
"Daisy Chains" with multiple outlets were found on board. 46CFR183.340
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 December 2020
No resolution recorded
Certificate of Documentation needs to be current. 46CFR67.7
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 June 2018
Resolved
03 KAPOK style deteriorated and destroyed. Replace with new CG approved type 1 adult PFDs. 46 CFR 180.71(A)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2018
Resolution: Vessel equiped with 03 new adult PFDs.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 June 2018
Resolved
Child PFDs not segregated from adult PFDs. Segregate Child from adult PFDs. 46 CFR 180.78
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2018
Resolution: Child PFDs placed in trash bag.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 June 2018
Resolved
01 Child PFD missing corrosion resistant clip. Provide new clip. 46 CFR 160.005-4(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2018
Resolution: New clip installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 June 2018
Resolved
Secure cable and wiring in engine room with metal supports not more than 24 inches apart.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2018