GALLANT LADY

GALLANT LADY is a 1940 passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 1986, most recently in December 2022, along with 67 deficiencies — 19 with no resolution recorded — and 2 operational controls.

Records from 1986 to 2022. Most recent: inspection, 7 December 2022.

Built
1940
Last inspected
7 December 2022
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI9636
Flag
UNITED STATES
367750660
Maury page id
psix-42020

Inspections, by type

…past their stated due date17
Years with a record 28 calendar years (1986–2022)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.0 ft × 15.9 ft × 6.3 ft
Registered tonnagegross 57 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTACOMA BOAT MAR · TACOMA, WA, UNITED STATES · built 1940
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTACOMA, WA
Trade endorsementsRecreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton
47 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI9636MMSI 367750660 · active · voluntarily equipped · granted 13 August 2016, expires 13 August 2026
WTT8337MMSI not assigned · expired · compulsorily equipped · granted 10 September 1996, cancelled 3 February 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 49

7 December 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7605777
16 March 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7412931
9 December 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7105321
11 September 2019 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6809236
7 August 2019 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6776153
22 October 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6557610
4 June 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6438446
1 September 2016 Internal Structural Exam · COI Inspection · Drydock Exam · Simplified Stability Test · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6138423
2 June 2008 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3222315
14 June 2007 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2961829
17 May 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2933354
27 April 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2918991
16 March 2006 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2603501
19 May 2005 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2363361
7 May 2005 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2351769
6 May 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2086281
23 June 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1824453
1 May 2003 Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1783853
18 June 2002 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1632901
4 March 2002 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1492006
7 March 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1389324
12 February 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386962
31 March 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1440290
26 April 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1378664
27 January 1999 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1458596
24 February 1998 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1394910
25 April 1997 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1364070
18 February 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1380761
28 February 1996 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1371296
6 March 1995 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1407433
3 May 1994 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1171595
1 March 1994 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1164112
26 February 1993 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 839053
8 January 1993 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1357980
14 October 1992 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1264503
3 April 1992 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1462294
27 March 1992 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1266103
9 March 1992 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 945848
19 July 1991 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1250185
22 March 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1305535
8 March 1991 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1305534
18 May 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 930574
16 March 1990 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 926538
12 March 1990 Drydock Extension · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1220168
23 March 1989 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1275832
21 March 1988 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1339459
13 November 1987 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1331781
27 March 1987 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1023190
7 April 1986 COI Inspection · Credit Drydock
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1304772

Deficiency record · 67

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 April 2022 No resolution recorded
Vessel must submit plans for the installation and use of monitoring devices to ensure wakefulness of the required night watch IAW 87 Federal Register 73160.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 April 2022 No resolution recorded
Vessel must submit evidence of developed safe handling procedures for the operation and storage of potentially hazardous items such as rechargeable batteries IAW 87 Federal Register 73160.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 April 2022 No resolution recorded
Vessel must submit evidence of marine firefighting training programs to improve crewmember training and proficiency, including egress training for each member of the crew. Vessel is not allowed to operate with overnight accommodations or on a Coastwise / Oceans route until above deficiencies are rectified. IAW 87 Federal Register 73160
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 December 2020 No resolution recorded
The life ring needs to be replaced or serviced, because lines are frayed and ring is very worn in certain spots. 46CFR176.808(b)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 December 2020 No resolution recorded
The hydrostatic release on the lifefloat needs to be removed, because it is improperly installed. 46CFR176.808(b)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2020 No resolution recorded
Chemical testing program is missing New policy statement, Signed statement of understanding, New Swabs. 46CFR16.230
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 December 2020 No resolution recorded
DSC is not installed on VHF radio. 47 CFR 80.1085(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 December 2020 No resolution recorded
Bilge alarm locations are not labeled in the pilot house. 46CFR182.100
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 December 2020 No resolution recorded
The life jackets that are stowed in forward berthing are not stored in a convenient place. 46CFR180.78
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 December 2020 No resolution recorded
Bilge high level alarm in engine room is inoperable and needs to be operating.46CFR182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 9 December 2020 No resolution recorded
No FCC operators permit present on board, operator needs permit. 47CFR13
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 9 December 2020 No resolution recorded
Forward most compartment has battery present and does not have ventilation. Ventilation needs to be present.46CFR183.350(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 9 December 2020 No resolution recorded
Forward most compartment has a light that is not intrinsically safe. 46CFR183.200(d)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 December 2020 No resolution recorded
Fireboy sytem has not been serviced and needs to be serviced.46CFR176.810(b)(1)(iv)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 December 2020 No resolution recorded
Generator needs guards where the belts are. 46CFR182.100
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 December 2020 No resolution recorded
Battery charger has loose terminal wires and needs safety cap.46CFR183.340
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 December 2020 No resolution recorded
Fire extinguishers need to be serviced. 46CFR176.810(b)(1)(iv)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 December 2020 No resolution recorded
"Daisy Chains" with multiple outlets were found on board. 46CFR183.340
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 December 2020 No resolution recorded
Certificate of Documentation needs to be current. 46CFR67.7
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 June 2018 Resolved
03 KAPOK style deteriorated and destroyed. Replace with new CG approved type 1 adult PFDs. 46 CFR 180.71(A)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2018
Resolution: Vessel equiped with 03 new adult PFDs.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 June 2018 Resolved
Child PFDs not segregated from adult PFDs. Segregate Child from adult PFDs. 46 CFR 180.78
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2018
Resolution: Child PFDs placed in trash bag.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 June 2018 Resolved
01 Child PFD missing corrosion resistant clip. Provide new clip. 46 CFR 160.005-4(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2018
Resolution: New clip installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 June 2018 Resolved
Secure cable and wiring in engine room with metal supports not more than 24 inches apart.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2018
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 2 June 2008 Resolved
Provide proof of current first aid/CPR training for 50% of crew.
Due 1 July 2008
Resolved 8 July 2008
Resolution: Vsl owner provided proof of first aid/CPF training via photograph of certification card issued 01JUL08.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 June 2008 Resolved
Replace 2 rejected lifejackets. Limited passenger count to # lifejackets available until replaced.
Due 1 July 2008
Resolved 20 June 2008
Resolution: 2 lifejackets replaced.
Engineering › Bilge Water Management System › Pump
Issued 2 June 2008 Resolved
Replace or prove proper operation of faulty bilge pump in engine room and shower area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2008
Resolved 20 June 2008
Resolution: bilge pump replaced in shower area. proper operation of bilge pump in engine room demonstrated
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 June 2008 Resolved
Provide battery covers for all batteries in engine space.
Due 1 July 2008
Resolved 4 June 2009
Resolution: Battery covers installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 June 2008 Resolved
Provide buoyant lifeline, retro reflective tape, operable light for ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2008
Resolved 20 June 2008
Resolution: all items provided
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 June 2008 Resolved
Provide Coast Guard Light List.
Due 1 July 2008
Resolved 20 June 2008
Resolution: light list provided
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 June 2008 Resolved
Provide US Coast Pilot.
Due 1 July 2008
Resolved 20 June 2008
Resolution: coast pilot provided
Lifesaving › Buoyant Apparatus › Marking
Issued 2 June 2008 Resolved
Provide proper markings for 2 buoyant apparatus.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2008
Resolved 20 June 2008
Resolution: proper markings provided for two 11 man buoyant apparatuses
Lifesaving › Lifefloat › Markings
Issued 2 June 2008 Resolved
Provide proper markings for lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2008
Resolved 20 June 2008
Resolution: lifefloat marked properly with the vessel''s name
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 June 2008 Resolved
Provide light for lifefloat
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2008
Resolved 20 June 2008
Resolution: light provided
Lifesaving › Lifefloat › Paddle
Issued 2 June 2008 Resolved
Provide paddles for lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2008
Resolved 27 June 2008
Resolution: Paddles provided.
Lifesaving › Lifefloat › Float-free Link
Issued 2 June 2008 Resolved
Prove proper arrangement and breaking strength of weak link for both lifefloat and buoyant apparatus.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2008
Resolved 27 June 2008
Resolution: Unsat survival craft was removed from vessel and passenger count reduced to allow vessel to carry passengers.
Communications › Alarms/Indicators › Fire Alarm
Issued 2 June 2008 Resolved
Prove proper operation of 2 smoke detectors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2008
Resolved 12 June 2008
Resolution: Tested sat.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 June 2008 Resolved
Provide emergency fuel shut-down located near fuel tank.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2008
Resolved 20 June 2008
Resolution: emergency fuel shut offs installed and operate properly
Lifesaving › Lifefloat › Capacity
Issued 2 June 2008 Resolved
provide appropriate number of survival craft for a total of 34 persons. total persons allowed reduced to 32.
Action required: 705 - Other - as specified
Due 20 July 2008
Resolved 30 June 2008
Resolution: survuval craft needs to be provided for 100% of total persons on board. New 835 issued to reduce passenger count to 22.
Lifesaving › Lifefloat › Capacity
Issued 2 June 2008 Resolved
Provide 100% of total personals allowed survival craft capacity. Total persons allowed recuded to 22 until additional survival craft is supplied and installation is completed to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 31 March 2012
Resolved 31 May 2017
Resolution: Vessel equiped with (2) life floats, providing 100% life saving equipment for 30 passengers in total.
Construction/Loadline › Structures › Superstructure
Issued 17 May 2007 Resolved
Replace rotted planks on port and starboard bow under rub rail.
Due 17 June 2007
Resolved 14 June 2007
Resolution: 4 planks from main deck removed and new planking installed.
Construction/Loadline › Structures › Deck Plating
Issued 17 May 2007 Resolved
Replace in kind soft plywood planking in the overhead on the aft deck, port side, specifically the 5th plank forward of the stern.
Action required: 705 - Other - as specified
Due 17 March 2008
Resolved 17 May 2007
Construction/Loadline › Penetrations › Bottom Plug
Issued 17 May 2007 Resolved
Renew bottom plug in bottom planking on the port side of the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2007
Resolved 14 June 2007
Resolution: New plug installed
Construction/Loadline › Structures › Superstructure
Issued 17 May 2007 Resolved
Replace deteriorated bow stanchion.
Due 17 June 2007
Resolved 14 June 2007
Resolution: Rewelded stanchion
Construction/Loadline › Penetrations
Issued 1 May 2003 Resolved
2 SEA VALVES IN PORT HEAD NEED TO BE REPLACED. LEGACY COMPONENT DESC: Valve Flange
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 4 June 2003
Resolution: Received faxed receipt for sea valves and mention that they were replaced.
Documentation › Logs/Records
Issued 5 March 2002 Resolved
Provide proof of enrollment in a drug and alcohol program. LEGACY COMPONENT DESC: Drug Test Records
Condition: Unknown
Due 14 March 2002
Resolved 5 March 2002
Electrical › Lighting (service)
Issued 5 March 2002 Resolved
Repair navigation lights. LEGACY COMPONENT DESC: navigation
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2002
Resolved 18 June 2002
Lifesaving › Buoyant Apparatus
Issued 5 March 2002 Resolved
Total persons allowed reduced to 44 until additional primary lifesaving is provided.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 April 2002
Resolved 18 June 2002
Resolution: Additional lifefloat installed.
Fire Fighting
Issued 26 April 1999 Resolved
PROVIDE SERVICE REPORT FOR FIXED CO2 NLT 25MAY99._x001C_
Condition: Unknown
Due 6 May 1999
Resolved 17 May 1999
Construction/Loadline
Issued 27 January 1999 Resolved
PROVIDE REPAIR PROPOSAL FOR RENEWAL OF FLOOR/RIB THROUGHBOLTS THROUGHOUT VESSEL.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Construction/Loadline
Issued 27 January 1999 Resolved
RENEW PLANK ABOVE RUB RAIL STARBOARD SIDE IWO TRANSOM.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Construction/Loadline
Issued 27 January 1999 Resolved
RENEW ROTTED PLANKING AFT OF #5 PORT SIDE PORTHOLE.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Lifesaving
Issued 27 January 1999 Resolved
REPAIR BROKEN RAILING MOUNTINGS, FORWARD, PORT SIDE.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Unknown
Issued 28 February 1996 Resolved
PROVIDE DOCUMENTATION OF AN ACCEPTABLE RANDOM DRUG TESTING POLICY BEING IMPLEMENTED.
Condition: Unknown
Due 7 March 1996
Resolved 4 March 1996
Lifesaving
Issued 6 March 1995 Resolved
PROVIDE A RESCUE PLATFORM AT BOTTOM OF LADDER TO ASSIST IN MAN OVERBOARD SITUATIONS.
Condition: Unknown
Due 6 March 1995
Resolved 6 March 1995
Electrical
Issued 1 March 1994 Resolved
PROVIDE DRIP SHIELDS ABOVE PORT AND STARBOARD BATTERY CHARGERS
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Lifesaving
Issued 1 March 1994 Resolved
PROVIDE WATERLIGHT FOR RING BUOY
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Lifesaving
Issued 1 March 1994 Resolved
PROVIDE WATERLIGHT FOR STARBOARD SIDE BUOYANT APPARATUS
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Fire Fighting
Issued 1 March 1994 Resolved
PROVIDE BATTERIES FOR SMOKE DETECTORS
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Lifesaving
Issued 1 March 1994 Resolved
REPAINT VESSEL NAME AND CAPACITY ON PORT SIDE BUOYANT APPARATUS
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Lifesaving
Issued 1 March 1994 Resolved
REATTACH WATERLIGHT CHAIN TO BUOYANT APPARATUS'
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Engineering
Issued 1 March 1994 Resolved
REPLACE FUEL LINE TO PORT SIDE GENERATOR
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Lifesaving
Issued 1 March 1994 Resolved
RESTRICT NUMBER OF PASSENGERS TO NUMBER OF SERIVICABLE LIFE PRESERVERS
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Electrical
Issued 9 March 1992 Resolved
PROVIDE U.S. COAST GUARD APPROVED PLANS FOR GALLANT LADY'S ELECTRICAL INSTALLATION.
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Electrical
Issued 9 March 1992 Resolved
REMOVE ALL WIRING FROM THE VESSEL THAT IS NOT CURRENTLY IN USE.
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Documentation
Issued 9 March 1992 Resolved
PROVIDE EVIDENCE OF VALID RADIOTELEPHONY CERTIFICATE TO THE SATISFACTION OFTHE ATTENDING MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Lifesaving
Issued 12 March 1990 Resolved
MARK LIFE PRESERVER STOWAGE WITH THE WORDS "LIFE PRESERVERS" AND WITH THE NUMBER CONTAINED IN EACH STOWAGE AREA. MARKING SHALL INDICATE SEPARATE STOWAGE OF ADULT AND CHILDRENS LIFE PRESERVERS.
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Navigation
Issued 21 March 1988 Resolved
PROVIDE BULBS OF PROPER FILAMENT HEIGHT FOR PORT AND STBD NAVIGATION RUNNNING LIGHTS.
Condition: Unknown
Due 21 March 1988
Resolved 21 March 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.