MAURY USCG vessel records
← All vessels

GALLANT LADY

GALLANT LADY is a 1940 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2016, most recently in December 2022, along with 23 deficiencies — 19 with no resolution recorded —.

Records from 2016 to 2022. Most recent: inspection, 7 December 2022.

Built
1940
Last inspected
7 December 2022
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 December 2022
…past their stated due date17
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI9636
Flag
UNITED STATES
Maury page id
psix-42020

Documentation record

Registered dimensions (L × B × D)61.0 ft × 15.9 ft × 6.3 ft
Registered tonnagegross 57 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTACOMA BOAT MAR · TACOMA, WA, UNITED STATES · built 1940
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portTACOMA, WA
Trade endorsementsRecreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton
47 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 8

7 December 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7605777
16 March 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7412931
9 December 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7105321
11 September 2019 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6809236
7 August 2019 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6776153
22 October 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6557610
4 June 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6438446
1 September 2016 Internal Structural Exam · COI Inspection · Drydock Exam · Simplified Stability Test · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6138423

Deficiency record · 23

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 April 2022 No resolution recorded
Vessel must submit plans for the installation and use of monitoring devices to ensure wakefulness of the required night watch IAW 87 Federal Register 73160.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 April 2022 No resolution recorded
Vessel must submit evidence of developed safe handling procedures for the operation and storage of potentially hazardous items such as rechargeable batteries IAW 87 Federal Register 73160.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 April 2022 No resolution recorded
Vessel must submit evidence of marine firefighting training programs to improve crewmember training and proficiency, including egress training for each member of the crew. Vessel is not allowed to operate with overnight accommodations or on a Coastwise / Oceans route until above deficiencies are rectified. IAW 87 Federal Register 73160
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 December 2020 No resolution recorded
The life ring needs to be replaced or serviced, because lines are frayed and ring is very worn in certain spots. 46CFR176.808(b)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 December 2020 No resolution recorded
The hydrostatic release on the lifefloat needs to be removed, because it is improperly installed. 46CFR176.808(b)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2020 No resolution recorded
Chemical testing program is missing New policy statement, Signed statement of understanding, New Swabs. 46CFR16.230
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 December 2020 No resolution recorded
DSC is not installed on VHF radio. 47 CFR 80.1085(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 December 2020 No resolution recorded
Bilge alarm locations are not labeled in the pilot house. 46CFR182.100
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 December 2020 No resolution recorded
The life jackets that are stowed in forward berthing are not stored in a convenient place. 46CFR180.78
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 December 2020 No resolution recorded
Bilge high level alarm in engine room is inoperable and needs to be operating.46CFR182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 9 December 2020 No resolution recorded
No FCC operators permit present on board, operator needs permit. 47CFR13
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 9 December 2020 No resolution recorded
Forward most compartment has battery present and does not have ventilation. Ventilation needs to be present.46CFR183.350(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 9 December 2020 No resolution recorded
Forward most compartment has a light that is not intrinsically safe. 46CFR183.200(d)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 December 2020 No resolution recorded
Fireboy sytem has not been serviced and needs to be serviced.46CFR176.810(b)(1)(iv)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 December 2020 No resolution recorded
Generator needs guards where the belts are. 46CFR182.100
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 December 2020 No resolution recorded
Battery charger has loose terminal wires and needs safety cap.46CFR183.340
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 December 2020 No resolution recorded
Fire extinguishers need to be serviced. 46CFR176.810(b)(1)(iv)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 December 2020 No resolution recorded
"Daisy Chains" with multiple outlets were found on board. 46CFR183.340
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2021 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 December 2020 No resolution recorded
Certificate of Documentation needs to be current. 46CFR67.7
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 June 2018 Resolved
03 KAPOK style deteriorated and destroyed. Replace with new CG approved type 1 adult PFDs. 46 CFR 180.71(A)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2018
Resolution: Vessel equiped with 03 new adult PFDs.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 June 2018 Resolved
Child PFDs not segregated from adult PFDs. Segregate Child from adult PFDs. 46 CFR 180.78
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2018
Resolution: Child PFDs placed in trash bag.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 June 2018 Resolved
01 Child PFD missing corrosion resistant clip. Provide new clip. 46 CFR 160.005-4(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2018
Resolution: New clip installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 June 2018 Resolved
Secure cable and wiring in engine room with metal supports not more than 24 inches apart.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2018

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.