← All vessels
CULEBRA DIVER
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named CULEBRA DIVER
CULEBRA DIVER is a 1994 passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 1994, most recently in April 2026, along with 150 deficiencies and 1 casualty investigation in 2009.
Records from 1994 to 2026. Most recent: inspection, 27 April 2026.
- Built
- 1994
- Last inspected
- 27 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 150 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2009
Identity
1029624
WDA3081
420200
Flag
UNITED STATES
368369350
Maury page id
psix-420200
Inspections, by type
…with no type recorded2
Years with a record
29 calendar years (1994–2026)
The 49 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)42.3 ft × 12.5 ft × 6.7 ft
Registered tonnagegross 23 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCUSTOM DIVE BOATS INC · DELAND, FL, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portST THOMAS, VI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Gross Ton
18 - Simplified, Net Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDP6089MMSI 368369350 · active · voluntarily equipped · granted 23 May 2024, expires 23 May 2034
WDA3081MMSI 366794420 · expired · compulsorily equipped · granted 3 December 2010, cancelled 13 February 2021
WCQ6162MMSI not assigned · expired · compulsorily equipped · granted 4 April 1995, cancelled 4 June 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 49
27 April 2026
Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8356701
5 January 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8290116
21 October 2024
Administrative Inspection · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8022460
16 January 2024
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7863428
11 January 2023
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7624573
21 October 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7584266
29 October 2021
Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7342017
23 October 2020
Drydock Exam · Internal Structural Exam · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7094225
25 October 2019
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6841784
22 April 2019
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6667614
29 January 2019
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6616529
26 October 2018
Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6568742
15 February 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6355582
3 October 2017
Damage Survey · In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6281779
15 February 2017
DAPI Audit · In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6090336
6 October 2016
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6017409
4 December 2015
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5775462
9 November 2015
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5779289
3 June 2014
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4878190
30 July 2012
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4396565
20 September 2011
Deficiency Check · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4150188
29 July 2011
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4105252
10 September 2010
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3846815
9 July 2008
Annual Inspection · Internal Structural Exam · Deficiency Check · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3262582
20 June 2008
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3243051
3 October 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3090924
14 May 2007
Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2930840
28 April 2006
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2635326
16 March 2006
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2606644
4 May 2005
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2349203
21 April 2004
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2049809
25 March 2004
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2030915
8 March 2003
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1754172
4 April 2002
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1603289
13 February 2002
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1487109
5 July 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1361569
28 June 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1051737
23 May 1999
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1471391
12 May 1999
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1434877
28 May 1998
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1381255
19 March 1998
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1375318
4 March 1998
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1375287
25 September 1997
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1375141
20 June 1996
Re-Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1448776
8 June 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1186377
31 May 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 874703
23 February 1995
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1459922
8 February 1995
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 845761
3 June 1994
Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1159656
Deficiency record · 150
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 15 February 2018
Resolved
Provide properly serviced fixed fire extinguisher in engine room.
Communications › Radio Communications › EPIRB
Issued 15 February 2018
Resolved
Provide EPIRB with valid battery.
Communications › Radio Communications › EPIRB
Issued 15 February 2018
Resolved
EPIRB hydrostatic release expired.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 15 February 2018
Resolved
Make electrical panel in fwd compartment water resistant or provide a drip shield.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 February 2018
Resolved
Properly secure starboard side navigation light.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 15 February 2018
Resolved
Provide current Coast Pilot [name withheld] and Light List.
Communications › Alarms/Indicators › High Water Alarm
Issued 3 October 2017
Resolved
High water alarm indicators at the operating station are not operational due to water damage from the storm.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 February 2017
Resolved
Provide current FCC Safety Radiotelephony Certificate.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 February 2017
Resolved
Provide log for EPIRB testing.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 February 2017
Resolved
Provide log book for drills and training.
Lifesaving › Lifebuoys › Serviceable
Issued 17 February 2017
Resolved
Replace ring buoy.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 February 2017
Resolved
Provide tether for waterlight on ring buoy.
Lifesaving › Lifefloat › Paddle
Issued 17 February 2017
Resolved
Provide paddles for life float.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 February 2017
Resolved
Provide vessel name on ring buoys.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 February 2017
Resolved
Provide batteries for water lights.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 February 2017
Resolved
Replace expired first aid items.
Communications › Visual Communication › Red Warning Signal
Issued 17 February 2017
Resolved
Provide required flares.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 February 2017
Resolved
Prove proper operation of bilge high water alarm.
Engineering › Fuel Oil Service System › Filter
Issued 9 November 2015
Resolved
1. Racor oil filter was found to have excessive sedimentation inside. Vessel operator was informed of situation and showed records of cleaning. Nevertheless it was required from them to ensure oil filters were cleaned within 7 days.
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 9 November 2015
Resolved
Air filter ILO turbo was found to extremely worn and it was required from them to replace it. Vessel operator was given 7 days to replace the parts.
Navigation › Piloting/Steering › Marine Charts
Issued 30 July 2012
Resolved
Provide up to date nautical chart.
Lifesaving › Lifefloat › Serviceable
Issued 30 July 2012
Resolved
Repair/replace lifefloat due to perforations and replace retroreflective material.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 30 July 2012
Resolved
Replace lifering grabline with an approved type grabline.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 July 2012
Resolved
Label all bilge alarms at the operating station panel.
Electrical › Electrical Distribution System (service) › Cable
Issued 30 July 2012
Resolved
Correct all dead end wiring found in the engine room.
Construction/Loadline › Hull › Bracket
Issued 30 July 2012
Resolved
Repair penetration found in portside, transom, steering compartment.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 30 July 2012
Resolved
Label all fire dampers.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 29 July 2011
Resolved
Prove proper operation of epirb and proof of battery expiration date. vessel is restricted to 3 miles.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 29 July 2011
Resolved
Provide up to date VOAA registration for the epirb.
Lifesaving › Lifefloat › Paddle
Issued 29 July 2011
Resolved
repair or replace lifefloat paddle.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 29 July 2011
Resolved
Provide 1 additional alcohol test kits for a total of 3 onboard.
Construction/Loadline › Penetrations › Pipe Flange
Issued 29 July 2011
Resolved
Properly block off unused discharge port on portside that is currently blocked off with duct tape
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 July 2011
Resolved
Provide proper supports for all loose wiring.
Engineering › Steering Gear System › Linkage
Issued 29 July 2011
Resolved
Tighten steering tie rod and prove proper operation.
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 29 July 2011
Resolved
Provide splash guard for terminal box in steering compartment.
Navigation › Piloting/Steering › Marine Charts
Issued 29 July 2011
Resolved
Provide up to date nautical charts.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 29 July 2011
Resolved
Properly fasten missing nut to port side chin.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 July 2011
Resolved
Provide proper size lifeline and proper amount of retroflective tape for ringbouy.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 29 July 2011
Resolved
Provide emergency instruction and post IAW 46 CFR 185.510
Engineering › Non-conventional Propulsion/Steering › Inlet Duct (jet)
Issued 29 July 2011
Resolved
Provide jet inspection cover plate and locking devise IAW manufactures specification.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 September 2010
Resolved
Repair all dead end wires on the vessel.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 10 September 2010
Resolved
Fire extinguisher needs to be properly mounted on fly bridge.
Engineering › Non-conventional Propulsion/Steering › Reverse Bucket (jet)
Issued 10 September 2010
Resolved
Engine slows to almost a stall when engaging from fwd to nuetral must prove proper operation of engine.
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 September 2010
Resolved
Repair compass light.
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 9 July 2008
Resolved
Replace broken cap on coolant reservoir.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 9 July 2008
Resolved
Rotate fire boy 90 degrees to face engine room.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 July 2008
Resolved
Replace first aid kit with Coast Guard approved first aid kit.
Electrical › Electric Supply System (service) › Battery Charger
Issued 9 July 2008
Resolved
Remove battery charger electrical run and replace with approved cable.
Engineering › Fuel Oil Service System › Filter
Issued 9 July 2008
Resolved
Install flame bowl on the bottom of the racor filter.
Electrical › Electric Supply System (service) › Cable
Issued 9 July 2008
Resolved
Remove dead end wiring from the fuel compartment space.
Engineering › Bilge Water Management System › Valve
Issued 9 July 2008
Resolved
Install handle on bilge discharge valve in way of fuel compartment aft bulkhead.
Engineering › Bilge Water Management System › Not Installed
Issued 9 July 2008
Resolved
Properly label all three separate bilge high level alarms.
Engineering › Steering Gear System › Hydraulic Hose
Issued 9 July 2008
Resolved
Replace collapsed hydraulic low pressure hose in the engine room.
Engineering › Bilge Water Management System › Valve
Issued 9 July 2008
Resolved
Install one way valve on rule bilge pump hose port side aft bulkhead fuel compartment space.
Engineering › Bilge Water Management System › Valve
Issued 9 July 2008
Resolved
Install one way valve on rule bilge pump hose port side aft compartment.
Engineering › Bilge Water Management System › Valve
Issued 9 July 2008
Resolved
Install one way valve on 4 rule bilge pump hoses port side fuel compartment space.
Engineering › Steering Gear System › Hydraulic Hose
Issued 3 October 2007
Resolved
Renew hose and fittings for jet drive selector bucket.
Construction/Loadline › Hull › Hull Plating
Issued 3 October 2007
Resolved
Renew all zinc anodes.
Engineering › Bilge Water Management System › Interface Detector
Issued 3 October 2007
Resolved
Permanently install fwd bilge switch.
Electrical › Electric Supply System (service) › Cable
Issued 3 October 2007
Resolved
Reinstall properly wiring in Aft jet drive compartment.
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 14 May 2007
Resolved
Provide navigation publications, US Coast Pilot [name withheld] and Tidal Current tables.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 May 2007
Resolved
Install visible high bilge water level alarm.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 May 2007
Resolved
Renew all faded retroreflective tape on all lifejackets.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 14 May 2007
Resolved
Repair inoperative engine RPM Gauge.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 4 May 2005
Resolved
Vessel to properly install stern markins. Vessel name and home port as per requirements of COD.
Documentation › Certificates/Documents › Stability Letter
Issued 4 May 2005
Resolved
Vessel does not have a copy of the stability letter. Copy found in unit files, to be delivered to vessel.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 4 May 2005
Resolved
Vessel to provide evidence of fixed fire fighting servicing.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 4 May 2005
Resolved
Vessel is required to have 1 B-I and 1 B-II portable ext. Vessel has 2 B-I. Vessel to obtain a B-II ext as per COI requirement and properly install.
Construction/Loadline › Structures
Issued 21 April 2004
Resolved
Reweld broken welds on Port side hand rails.
Construction/Loadline › Hull › Bottom Plating
Issued 21 April 2004
Resolved
Repair 16 fiber glass coat blisters to the satisfaction of attending marine inspector.
Documentation › Certificates/Documents
Issued 25 March 2004
Resolved
Vessel continued operating without a valid COI. Owner failed to completed a Reinspection within the 90 day window. LEGACY COMPONENT DESC: Certificate of Inspection
Engineering › Non-conventional Propulsion/Steering
Issued 25 March 2004
Resolved
Make proper repairs to the vsls Jet Drive. When running the drive in neutral, a large quantity of water leak inside the engine compartment. LEGACY COMPONENT DESC: Inlet Duct (jet)
Engineering › Steering Gear System
Issued 8 March 2003
Resolved
Hydraulic Hoses and fittings are wasted and require replacement. Replace all hoses and fittings with apporved type hoses and re-rigg using metal compression clamps and eliminate all plastice wire ties. LEGACY COMPONENT DESC: Hydraulic Hose
Fire Fighting › Semiportable CO2 Fire Extinguishers
Issued 8 March 2003
Resolved
Provide servicing reports for all extinguishers onboard. Inclusive of portable and the pre -Engineered engine space extinguisher system. Verify the proper installation of the fixed fire suppression system in specifically ensure the nozzle is faced in accordance with the manufactures instructions LEGACY COMPONENT DESC: Service
Lifesaving › Lifejacket/PFD (Type IV)
Issued 8 March 2003
Resolved
Replace all reflective tape on the ring bouy. Attach a line with a coroos LEGACY COMPONENT DESC: Retroreflective Material
Lifesaving › Buoyant Apparatus
Issued 8 March 2003
Resolved
Replace all Retro tape on the Life Foat.
Operations/Management › Navigation Safety
Issued 8 March 2003
Resolved
Provide copies of all required charts and publications that are applicable to the vessels operating area. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Operations/Management › Drug and Alcohol Testing
Issued 8 March 2003
Resolved
Provide proof of crews active participation in an approved drug screening program.
Documentation › Certificates/Documents
Issued 8 March 2003
Resolved
Attempt to locate the vessels current Certificate Of Inspection. LEGACY COMPONENT DESC: Certificate of Inspection
Operations/Management › Drills/Instruction
Issued 8 March 2003
Resolved
Post required Emergency Instructon Lists.
Construction/Loadline › Hull
Issued 4 April 2002
Resolved
Make permanent repairs to the 9 Blisters in the port side and 15 blisters in the starboard side of the hull below the water line. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull
Issued 4 April 2002
Resolved
Grind out and make available for inspection the 3 inch crack in the keel located approximately 10' aft of the stem. LEGACY COMPONENT DESC: Keel
Engineering › Bilge Water Management System
Issued 4 April 2002
Resolved
Replace damaged diaphram on the emergency bilge pump. LEGACY COMPONENT DESC: Pump
Construction/Loadline › Hull
Issued 4 April 2002
Resolved
Grind out and make permanent repairs to old damage putty filled area on the stem of the vessel. LEGACY COMPONENT DESC: Hull Plating
Engineering › Steering Gear System
Issued 4 April 2002
Resolved
Replace corroded mounting plate in the transom for the jet drive bucket. LEGACY COMPONENT DESC: Bracket/Clamp
Documentation › Logs/Records
Issued 13 February 2002
Resolved
SJ01: Conduct and log training as required by 46 CFR 185.420, 185.520, and 185.524. ( Last drills logged were performed on 24 APR 01.) LEGACY COMPONENT DESC: Logbook (official)
Documentation › Logs/Records
Issued 13 February 2002
Resolved
SJ02: Conduct and log monthly EPIRB test as required by 46 CFR 185.728. LEGACY COMPONENT DESC: Logbook (official)
Operations/Management › Navigation Safety
Issued 13 February 2002
Resolved
SJ03: Place onboard, the charts and nautical publications as required by 46 CFR 184.420. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Communications › Audible Communications
Issued 13 February 2002
Resolved
SJ04: Repair and prove proper operation of vessels sound signaling device (horn). LEGACY COMPONENT DESC: Horn/Whistle
Lifesaving › Hand Flares
Issued 13 February 2002
Resolved
SJ05: Provide onboard 6 hand orange smoke distress signals as required by 46 CFR 180.68.
Lifesaving › Buoyant Apparatus
Issued 13 February 2002
Resolved
SJ06: Repair or replace and prove proper operation of waterlight for life float. 46 CFR 180.175 LEGACY COMPONENT DESC: Water light
Lifesaving › Lifejacket/PFD (Type I)
Issued 13 February 2002
Resolved
SJ07: Provide 3 additional adult size, Type I life jackets as required by COI. Ensure jackets are marked with vessels name. LEGACY COMPONENT DESC: Quantity
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 13 February 2002
Resolved
SJ08: Replace discharged B-I fire extinguisher and provide proof of annual servicing of all portable fire extinguishers onboard in accordance with Chapter 4 of NFPA 10. 46 CFR 176.810 LEGACY COMPONENT DESC: Pressure
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 13 February 2002
Resolved
SJ09: Provide proof of annual service performed on the fixed halon system in the engine room in accordance with 46 CFR 176.810. LEGACY COMPONENT DESC: Proof of annual service
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 13 February 2002
Resolved
SJ10: Make permanent repairs to exhaust leak in the flexible hose driving the turbo charger. LEGACY COMPONENT DESC: Turbocharger
Engineering › Bilge Water Management System
Issued 13 February 2002
Resolved
SJ11: Permanently mount all 3 submersible bilge pumps and prove proper operation. 46 CFR 182.520 LEGACY COMPONENT DESC: Pump
Operations/Management › Pollution
Issued 13 February 2002
Resolved
SJ12: Remove all standing water and oil from all bilges. LEGACY COMPONENT DESC: Retention of Oily Mixture
Construction/Loadline › Penetrations
Issued 13 February 2002
Resolved
SJ13: Install positive shut off valves at the hull penetration of each submersible bilge pump's discharge.
46 CFR 182.520
LEGACY COMPONENT DESC: Positive shutoff valves for bilge discharge
Electrical › Electrical Distribution System (service)
Issued 13 February 2002
Resolved
SJ14: Make permanent repairs to main fuse panel at control station, in particular the fuse for the radio, and prove proper operation of panel and all fuses and switches. LEGACY COMPONENT DESC: Fuse
Operations/Management › Pollution
Issued 13 February 2002
Resolved
SJ15: Secure and lock the overboard discharge for the MSD. LEGACY COMPONENT DESC: Overboard discharge for MSD
Accommodation/Occupational Safety › Medical/First Aid
Issued 13 February 2002
Resolved
SJ16: Provide new first aid kit that is approved in accordance with 46 CFR 160.041 or restock current one. LEGACY COMPONENT DESC: Medicine Chest
Unknown
Issued 5 July 2000
Resolved
FUMIGATE AND REMOVE BUGS FROM FUEL TANK AREA FOR FURTHER INSPECTION.
Fire Fighting
Issued 5 July 2000
Resolved
SERVICE FIXED FIRE FIGHTING EXTINGUISHING SYSTEM
Engineering
Issued 5 July 2000
Resolved
REPAIR PROPULSION JET TURBINE STATOR, DETERMINE CAUSE OF NOZZLE STEERING PLAY.
Construction/Loadline
Issued 5 July 2000
Resolved
SEAL REVERSER BUCKET CONTROL CABLE IN TRANSOM STBD SIDE
Construction/Loadline
Issued 5 July 2000
Resolved
PROVIDE WRITTEN REPAIR PROPOSAL FOR DAMAGED PORT BOW SECTION.
Construction/Loadline
Issued 5 July 2000
Resolved
REPAIR GOUGES IN STEM ABOVE WATERLINE
Construction/Loadline
Issued 5 July 2000
Resolved
PROVIDE VISUAL INDICATOR FOR AUTOMATIC BILGE PUMPS
Construction/Loadline
Issued 5 July 2000
Resolved
REPAIR CRACKS IN TRANSOM STEP
Electrical
Issued 5 July 2000
Resolved
CONNECT BONDING SYSTEM, REPAIR BROKEN CONNECTING CABLES.
Engineering
Issued 5 July 2000
Resolved
RENEW RAW WATER SUCTION HOSE FROM SEA VALVE TO STRAINER, RENEW ALL HOSE CLAMPS.
Construction/Loadline
Issued 5 July 2000
Resolved
MAKE ALL SEA VALVES AND STRAINERS AVAILABLE FOR INSPECTION.
Construction/Loadline
Issued 5 July 2000
Resolved
TEST ALL BILGE PUMPS AND HIGH BILGE LEVEL ALARMS IN THE PRESENCE OF CG INSPECTORS.
Documentation
Issued 28 June 2000
Resolved
MAKE VESSEL AVAILABLE FOR REINSPECTION IAW 46 CFR 176.500 PRIOR TO CARRYINGPASSENGERS.
Fire Fighting
Issued 12 May 1999
Resolved
RENEW FIRE EXTINGUISHERS BRACKETS IN FWD COMPARTMENT.
Electrical
Issued 12 May 1999
Resolved
PROVIDE 2 PORTABLE LIGHTS FOR EMERGENCY LIGHTING.
Lifesaving
Issued 12 May 1999
Resolved
CONDUCT MAN OVERBOARD/FIRE DRILL IN PRESENCE OF CG INSPECTOR.
Lifesaving
Issued 12 May 1999
Resolved
REPAIR PUNCTURE HOLES ON LIFEFLOAT AND RENEW RETROTAPE.
Construction/Loadline
Issued 28 May 1998
Resolved
INSTALL BACKING PLATED ON THRU-BOLTS MOUNTING DIVE PLATFORM TO TRANSOM
Engineering
Issued 28 May 1998
Resolved
INSTALL HOSE CLAMPS ON ENGINE CRANKCASE OIL DRAIN HOSE
Engineering
Issued 28 May 1998
Resolved
INSTALL MISSING FORWARD MOUNTING CLAMP ON MUFFLER
Construction/Loadline
Issued 4 March 1998
Resolved
MAKE MAIN ENGINE SEA SUCTION VALVE OPERABLE
Lifesaving
Issued 4 March 1998
Resolved
PROVIDE 02 FLASHLIGHTS
Accommodation/Occupational Safety
Issued 4 March 1998
Resolved
PROVIDE DOUBLE CLAMPS ON ALL MSD THRU-HULL FITTINGS
Lifesaving
Issued 4 March 1998
Resolved
RENEW ZIPPERS ON LIFE JACKET STOWAGE BAGS
Navigation
Issued 4 March 1998
Resolved
RENEW CLEVIS PIN FOR STEERING RAM
Lifesaving
Issued 4 March 1998
Resolved
PROVIDE SEPARATE STOWAGE FOR CHILD SIZE LIFE JACKETS
Fire Fighting
Issued 4 March 1998
Resolved
PROVIDE 01 ADDITIONAL FIRE BUCKET WITH LANYARD
Fire Fighting
Issued 4 March 1998
Resolved
PROVIDE ANNUAL SERVICE FOR PILOT STATION FIRE EXTINGUISHER
Construction/Loadline
Issued 4 March 1998
Resolved
RENEW ALL BILGE SUCTION VALVE HANDLES
Electrical
Issued 4 March 1998
Resolved
PROVIDE PROPER WIRING FOR AFT ELECTRIC BILGE PUMP
Engineering
Issued 4 March 1998
Resolved
REFASTEN CATCH CAN FOR MAIN ENGINE EXPANSION TANK
Lifesaving
Issued 4 March 1998
Resolved
STENCIL VESSEL NAME ON LIFE FLOAT PADDLES
Navigation
Issued 4 March 1998
Resolved
PROVIDE TOOLS NEEDED TO INSTALL EMERGENCY TILLER TO BE LOCATED WITH TILLER
Documentation
Issued 25 September 1997
Resolved
PROVIDE LOG BOOK TO DOCUMENT CREW TRAINING AND DRILLS.
Lifesaving
Issued 25 September 1997
Resolved
PROVIDE COAST GUARD APPROVED FIRST AID KIT.
Lifesaving
Issued 25 September 1997
Resolved
PROVIDE A PAINTER FOR BOUYANT APPARATUS THAT DOES NOT LIMIT THE FLOAT FREE ARRANGEMENT
Navigation
Issued 25 September 1997
Resolved
PROVIDE EMERGENCY STEERING.
Lifesaving
Issued 25 September 1997
Resolved
PROVIDE PADDLES FOR BOUYANT APPARATUS.
Lifesaving
Issued 20 June 1996
Resolved
NO LATER THAN 11 MARCH 1997, INSTALL ON BOARD IN A FLOAT FREE ARRANGEMENT, A FCC ACCEPTED, CATEGORY 1, 406MHz EPIRB.
Fire Fighting
Issued 23 February 1995
Resolved
PROVIDE PORTABLE FIRE PUMP, MINIMUM CAPACITY 5 GPM.
Fire Fighting
Issued 23 February 1995
Resolved
PROPERLY INSTALL ALL HAND PORTABLE FIRE EXTINGUISHERS.
Lifesaving
Issued 23 February 1995
Resolved
PLACE ON BOARD ONE ADDITIONAL CHILD LIFE PRESERVER FOR A TOTAL OF THREE PRIOR TO CARRYING MORE THAN TWO CHILDREN.
Navigation
Issued 23 February 1995
Resolved
PROVIDE FCC STATION LIC. & SAFETY CERT.
Fire Fighting
Issued 23 February 1995
Resolved
LABLE HAND PORTABLE FIRE EXTINGUISHER LOCATION.
Documentation
Issued 3 June 1994
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, CONTACT THE [name withheld] OF THE ZONEWHICH THE VESSEL IS OPERATING IN._x001C_ _x001C_ _x001C_
Lifesaving
Issued 3 June 1994
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, SUPPLY LIFESAVING EQUIPMENT AS REQUIRED IN 46 CFR PART 180.
Fire Fighting
Issued 3 June 1994
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVIDE PORTABLE FIRE EXTINGUISHERS_x001C_ IN ACCORDANCE WITH 46 CFR 181.30
Documentation
Issued 3 June 1994
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, ENSURE ALL REQUIREMENTS FOR THE FEDERAL COMMUNICATION COMMISSION ARE MET IN ACCORDANCE 46CFR 184.25-1._x001C_ _x001C_ _x001C_
Documentation
Issued 3 June 1994
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVIDE VESSEL DOCUMENTATION IN ACCORDANCE WITH 46CFR PART 67.
Casualty record · 1
12 September 2009Routine · role: Involved in a Marine Casualty · activity 3634012
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.