POSEIDON'S MAIDEN I

POSEIDON'S MAIDEN I is a passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1995, most recently in May 2026, along with 108 deficiencies, 1 operational control and 3 casualty investigations between 2011 and 2021.

Records from 1995 to 2026. Most recent: inspection, 31 May 2026.

Built
Not recorded
Last inspected
31 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ7636
420307
Flag
UNITED STATES
367691000
Maury page id
psix-420307

Inspections, by type

…with no type recorded9
Years with a record 30 calendar years (1995–2026)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it3 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDJ7636MMSI 367691000 · active · compulsorily equipped · granted 4 October 2017, expires 4 October 2027 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 66

31 May 2026 Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8385024
11 May 2026 Drydock Exam · In-Service Inspection · Vessel Attendance
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8370488
10 February 2026 In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8309595
5 September 2025 Periodic Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8227446
19 May 2025 In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8138759
18 January 2025 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8065325
30 July 2024 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7970246
22 May 2024 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7916815
7 June 2023 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7916840
17 May 2022 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7448032
21 April 2022 Administrative Inspection · COI Inspection · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7435142
22 November 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7355264
4 November 2021 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7345152
2 November 2021 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7345783
27 August 2021 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7297889
21 July 2020 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7012647
3 March 2020 Internal Structural Exam · In-Service Inspection · Examination of Repairs · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6919353
8 January 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6884765
7 December 2019 In-Service Inspection · Damage Survey · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6869627
7 December 2019 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6869686
22 May 2019 Deficiency Check · Periodic Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6695986
24 August 2018 Annual Inspection · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6523827
11 July 2018 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6476148
17 May 2018 Hull Examination · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6419279
7 February 2017 Hull Examination · Administrative Inspection · Examination of Repairs · COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6083748
21 June 2016 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5913916
30 May 2016 Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 5892139
30 March 2016 Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5844037
23 March 2016 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5838607
13 August 2015 Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 5215511
19 October 2014 Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 5007709
28 March 2014 Annual Inspection · DAPI Audit
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4820138
17 August 2011 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4120169
24 January 2011 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3933975
23 January 2010 Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3668784
15 January 2009 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3393660
21 January 2008 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3133963
28 February 2007 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2878845
25 January 2007 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2860774
22 March 2006 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2606882
23 February 2006 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2590298
23 January 2006 Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2571079
23 March 2005 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2317092
26 February 2004 Internal Structural Exam · Hull Examination · Periodic Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2014095
18 April 2003 Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1775910
1 April 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1766175
25 March 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1762524
18 March 2003 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1758726
23 November 2002 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1709669
15 March 2002 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1615933
28 February 2002 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1490288
24 January 2001 MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361938
9 May 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 818421
25 February 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 815768
26 January 2000 Hull Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1397333
6 June 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 72438
22 March 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1340802
14 January 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1378550
30 May 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 797187
9 February 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 792315
3 February 1998 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1107457
26 January 1998 COI Inspection · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 773646
7 March 1997 Hull Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1098249
15 April 1996 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1086188
15 April 1995 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 909577
7 March 1995 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1387712

Deficiency record · 108

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 January 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. While operating in the vicinity of Apra Harbor with passengers, main engine experienced overheating and was towed back to berth. Determine cause, affect repairs, and perform sea trials to the satisfaction of attending Marine Inspector. 46 CFR 182.200(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2025
Resolved 12 March 2025
Resolution: Turbo charger replaced. Sea trials conducted in prescence of attending Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 July 2024 Resolved
A valid certificate of number or temporary certificate for that vessel issued by the issuing authority in the State in which the vessel is principally operated. Vessels state registration was expired at the time of inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2024
Resolved 9 August 2024
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 July 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: 1.Charts of large enough scale to make safe navigation possible 2. Tide tables Vessel could not provide charts or tide tables during the time of inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2024
Resolved 9 August 2024
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 June 2022 Resolved
EPIRB registration is valid but incorrect call sign.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 June 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 9 June 2022 Resolved
Missing asprin in the first aid kit.
Action required: 10 - Deficiency Rectified
Resolved 9 June 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 June 2022 Resolved
Bilge pump in operation light is not illuminating.
Action required: 10 - Deficiency Rectified
Resolved 9 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 June 2022 Resolved
Fuel tank gauge inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 June 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 May 2022 Resolved
Bilge alarm and fuel tank gauge inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 May 2022
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 May 2022 Resolved
EPIRB registration call sign is incorrect.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2022 Resolved
Expired aspirin in the first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 November 2021 Resolved
Replace missing battery cover for both port/starboard batteries. Batteries are located directly below overboard discharge valves that penetrates the transom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2021
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 November 2021 Resolved
Properly close gaps/openings on port/stbd aft engine compartment to prevent passage of smoke and fire extinguishing from escaping engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 November 2021 Resolved
Missing double clamps on both ends of the hoses for submersible bilge pumps in engine room compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 November 2021 Resolved
Repair engine hatch cover with wasted and cracked flange in way of hinges; install spacers for disimilar metals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 30 July 2024
Resolution: Deficiency verified corrected during 2024 annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 November 2021 Resolved
Determine cause of engine failure and effect repairs. Prior to scheduling USCG for follow up attendance, conduct operational test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2021
Resolution: Fuel valve was found partially closed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 August 2021 Resolved
Floating water light lanyard was wasted and needs to be replaced.
Action required: 10 - Deficiency Rectified
Resolved 27 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 August 2021 Resolved
Portable fire extinguisher at the operating station was discharged and need to be replaced.
Action required: 10 - Deficiency Rectified
Resolved 27 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 June 2019 Resolved
Replace the battery in the life ring buoy floating water light with expiration date of 2015 as required by 46 CFR 185.726(d).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 June 2019 Resolved
Effect repairs to the jet drive bucket control cables through hull fitting, fitting currently installed is allowing the ingress of sea water in the engine compartment as required by 46 CFR 320(c).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 June 2019 Resolved
Renew engine compartment gaskets to the vessels transom to mitigate the potential for water ingress and down flooding as required by 46 CFR 360.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 19 June 2019 Resolved
FCC radio station authorization and safety radio telephony certificates do no have the same call signs assigned, 47 CFR 80.141
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2019
Resolved 2 September 2019
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 19 June 2019 Resolved
Permanently affix state registration numbers to the port and starboard sides of the vessel, 33 CFR 173.27.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 June 2019 Resolved
Install appropriate length lanyard to the life ring buoy floating water light IAW 46 CFR 180.70.(d)(2).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2019
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 June 2019 Resolved
Repair or replace missing lanyard on 01 fire buckets IAW 46 CFR 181.610.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2019
Resolution: Lanyard replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 June 2019 Resolved
Install gasketing under operating console portable fire extinguisher, extinguisher is chaffing through the aluminum base, 46 CFR 181.520.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2019
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 19 June 2019 Resolved
Ensure proper fit and seal for engine compartment fire dampeners, current dampeners are unable to completely seal off the engine intake air, 46 CFR 182.460(l).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2019
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 June 2019 Resolved
Re-install mounting hardware for vessel canopy top, 46 CFR 177.800(c).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2019
Resolution: Hardware installed.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 22 May 2019 Resolved
Make repairs to the attachment point for the starboard quarter dive ladder.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2019
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2018 Resolved
Install visual indicating light at the operating station for the automatic actuation for the engine compartment electric submersible pump as required by 46 CFR 182.530(c).
Action required: 705 - Other - as specified
Due 4 September 2018
Resolved 4 September 2018
Resolution: Visual indicating light installed at the operating station, light and bilge pump succesfully op tested. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2018 Resolved
Provide proof of required chemical testing for vessel master IAW 46 CFR 16.210.
Action required: 705 - Other - as specified
Due 4 September 2018
Resolved 29 August 2018
Resolution: Received chain of custody for pre-employment testing. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 August 2018 Resolved
Attach lanyards to the 03 fire buckets onboard IAW 46 CFR 181.610.
Action required: 10 - Deficiency Rectified
Resolved 28 August 2018
Resolution: Vessel crew installed satisfactory lanyard to fire buckets, corrected on the spot.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 24 August 2018 Resolved
Provide proof of marine radio operators permit for vessel master IAW 47 CFR 80.175.
Action required: 705 - Other - as specified
Due 4 September 2018
Resolved 4 September 2018
Resolution: A FCC Reference copy of the MRO permit was provided as proof of the Captain holding a valid permit.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2018 Resolved
Zipties were sole cable securing device on board. Replace with metallic securing devices.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2018
Resolved 21 May 2018
Resolution: Zipties were replaced with metallic cable securing devices.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 3 August 2017 Resolved
Provide valid Guam registration.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 8 August 2017
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 August 2017 Resolved
Provide 2017 USCG Light Light
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Navigation › Piloting/Steering › US Coast Pilot
Issued 3 August 2017 Resolved
Provide 2017 Coast Pilot
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Navigation › Piloting/Steering › Marine Charts
Issued 3 August 2017 Resolved
Provide up to date navigation chart.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 3 August 2017 Resolved
Provide current tide tables.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 August 2017 Resolved
Prove proper operation of all around white light.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 3 August 2017 Resolved
Enter vessel MMSI number into VHF radio.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 1 October 2017
Documentation › Certificates/Documents › FCC SSL
Issued 3 August 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 1 October 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 January 2010 Resolved
Found death end wire under operator control counsel. Remove death end wire.
Action required: 705 - Other - as specified
Due 5 February 2010
Resolved 27 January 2010
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 23 January 2010 Resolved
Found salt water leaking from non- metallic exhaust pipe. Repair salt water leak.
Due 5 February 2010
Resolved 27 January 2010
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 January 2010 Resolved
Found (3) poor condition type i child life jackets due to deteriorate inner core. Replace (3) children life jackets.
Action required: 705 - Other - as specified
Due 5 February 2010
Resolved 28 March 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 January 2010 Resolved
Provide a proof of service conducted on all portable fire extinguishers.
Due 9 February 2010
Resolved 27 January 2010
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 15 January 2009 Resolved
Provide proof of currency in First Aid/CPR for 50% of crew IAW NVIC 1-91.
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 23 January 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 January 2009 Resolved
Renew expired items in first aid kit IAW 46CFR184.710.
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 23 January 2009
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 15 January 2009 Resolved
Provide donning placards for the jacket style lifejacket IAW 46CFR185.516.
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 15 January 2009
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (electric)
Issued 15 January 2009 Resolved
Prove proper operation of propulsion machinery (unable to turn off engine from operating station).
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 20 January 2009
Construction/Loadline › Hull › Hull Plating
Issued 15 January 2009 Resolved
Make permanent repairs to the internal bulkheads of the main tubes. Provide written repair proposal prior to start of repairs.
Action required: 705 - Other - as specified
Due 1 July 2009
Resolved 5 June 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 January 2008 Resolved
Replace expired items in first aid kit.
Action required: 705 - Other - as specified
Due 21 February 2008
Resolved 28 January 2008
Resolution: All expired items replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 January 2007 Resolved
Found dead end wires in way of the operators station. Remove dead end wires or end in a junction box with labels on both ends.
Due 25 February 2007
Resolved 1 March 2007
Navigation › Piloting/Steering › Marine Charts
Issued 25 January 2007 Resolved
Found the chart on board not up to date. Prove vessel's chart is current with correction from the local notice to mariners.
Due 25 February 2007
Resolved 27 February 2007
Stability › Unintentional Flooding › General
Issued 25 January 2007 Resolved
Found water leaking into the bilge from the jet drive shifting cable grommet. Make permanent repairs to prevent leak.
Due 25 February 2007
Resolved 27 February 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 January 2007 Resolved
Found the first aid kit with expired asprin. Remove and replace exprired asprin.
Due 25 February 2007
Resolved 27 February 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 25 January 2007 Resolved
Found the portable CO2 extinguisher at the operators station not fully charged. Recharge and service fire extinguisher.
Due 25 February 2007
Resolved 1 March 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 25 January 2007 Resolved
Found the visual bilge alarm not properly operating. Repair or replace visual bilge alarm.
Due 25 February 2007
Resolved 27 February 2007
Documentation › Certificates/Documents › FCC SSL
Issued 25 January 2007 Resolved
Found vessel operator without a current Marine Radio Operator Permit. Prove all vessel operators have current Marine Radio Operator Permits.
Due 25 February 2007
Resolved 1 March 2007
Operations/Management › Drills/Instruction › Fire
Issued 23 January 2006 Resolved
Found vessel missing emergency instruction list for fire flooding and man overboard. Post emergency instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 23 February 2006
Resolution: Witnessed emergency instructions
Lifesaving › Lifefloat › Float Free
Issued 23 January 2006 Resolved
Found life float not in a float free arrangement. Prove life float will float free.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 22 March 2006
Lifesaving › Lifefloat › Retroreflective Material
Issued 23 January 2006 Resolved
Found retro-reflective material worn. Replace retro-reflective material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 22 March 2006
Lifesaving › Lifefloat › Paddle
Issued 23 January 2006 Resolved
Found life float paddles missing vessel name. Stencil paddles with vessels name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 23 February 2006
Resolution: Witness paddles stenciling.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 January 2006 Resolved
Found lifebuoy retro-reflective material worn. Replace retro-reflective material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 23 February 2006
Resolution: Witnessed new lifebouy retro-reflective material.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 January 2006 Resolved
Found outdated medical supplies in first aid kit. Replace all outdated medical supplies.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 23 February 2006
Resolution: Witnessed updated medical supplies.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 23 January 2006 Resolved
Found emergency fire ducting covers made of combustible materials. Replace ducting covers with non-combustible materials.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 23 February 2006
Resolution: Witnessed metal ventilation duct covers.
Construction/Loadline › Hull › Hull Plating
Issued 23 January 2006 Resolved
Found plastic end cap on disconnected through hull pipe. Install approved end cap or crop and renew as original hull plate to eliminate disconnected through hull pipe.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 23 February 2006
Resolution: Witnessed metal end cap
Documentation
Issued 18 March 2003 Resolved
Vessel operator, [name withheld], without FCC Operators Permit in non-adherence with 47 CFR 80. Operator may not be employed on this craft or other vessel's owned by Saipan Aqua Jet if he fails to comply by April 18, 2003.
Due 18 April 2003
Resolved 18 April 2003
Resolution: Company has employed different operator.
Personnel › Training
Issued 18 March 2003 Resolved
Vessel operator and crewmember not familiar with Saipan Aqua Jet Inc.'s Employee Assistance Program (EAP) under 46 CFR 16. Saipan Aqua Jet Inc. shall instruct employees on their EAP and provide appropriate documentation pertaining to the EAP.
Due 18 April 2003
Resolved 18 April 2003
Resolution: Corrected.
Lifesaving
Issued 18 March 2003 Resolved
Life float/Boyant Apparatus paddle broken. A satisfactory replacement paddle shall be provided not later than 25 Mar 03.
Due 18 April 2003
Resolved 18 April 2003
Resolution: Corrected.
Engineering
Issued 18 March 2003 Resolved
Vessel sea valves shall be made available for inspection not later than 25 March 2003.
Due 25 March 2003
Resolved 25 March 2003
Lifesaving
Issued 18 March 2003 Resolved
Some lifejacket (PFDs) retroreflective material is deteriorated in non-adherence with 46 CFR 180 and Q specs. Owner/operator shall go through PFDs and replace deteriorated retroreflective material not later than 18 April 2003.
Due 18 April 2003
Resolved 18 April 2003
Resolution: Corrected.
Operations/Management
Issued 18 March 2003 Resolved
Drills not being conducted on a periodic (monthly basis). Owner/operator shall ensure that periodic man overboard drills, firefighting drills, and monthly EPIRB test conducted and documented in accordance with 46 CFR 185 and NVIC 1-91.
Due 18 April 2003
Resolved 18 April 2003
Resolution: Corrected.
Navigation
Issued 18 March 2003 Resolved
Navigation Charts & pubs not currently corrected in non-adherence with 46 CFR 184. Charts & pubs shall be corrected not later than 25 March 2003. This is a recurrent deficiency.
Due 1 April 2003
Resolved 1 April 2003
Navigation
Issued 18 March 2003 Resolved
Navigation lights not working in non-adherence with the COLREGs. Until such time navlights repaired to the satisfaction of the attending USCG marine inspector, vessel ops limited to daylight hours only subject to visibility not less than 3 nm. This is a recurrent problem.
Due 25 March 2003
Resolved 25 March 2003
Construction/Loadline
Issued 18 March 2003 Resolved
Stbd side aft engine cover closure removed in non-adherence with 49 CFR 179 and original vessel plan approval. Cover closure shall be reinstalled to the satisfaction of the attending USCG marine inspector not later than 25 March 2003.
Due 25 March 2003
Resolved 25 March 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 28 February 2002 Resolved
Fuel tank corroded iwo fills/discharges. Temporary repair to be conducted NLT 03Mar2002, w/permanent weld repair NLT 30Apr2002. Tank removal required w/USCG inspection of vsl structure iwo tank & full tank structure. Post tank repair NDE & pressure test required. LEGACY COMPONENT DESC: Tank
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 April 2002
Resolved 18 April 2002
Resolution: Corrected by Seafix w/required pressure test.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 28 February 2002 Resolved
Propulsion engine seawater intake valve frozen in place. Satisfactory repair/replacement required NLT 03Mar2002.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 March 2002
Resolved 6 March 2002
Resolution: Valve replaced.
Lifesaving
Issued 26 January 2000 Resolved
Provide and post a life jacket donning placard for the type of life jacketscarried on the vessel.
Condition: Unknown
Due 26 January 2000
Resolved 26 January 2000
Lifesaving
Issued 26 January 2000 Resolved
Log the performance of quarterly fire and man overboard drills in the vessel's log.
Condition: Unknown
Due 26 January 2000
Resolved 26 January 2000
Navigation
Issued 26 January 2000 Resolved
Prove the operation of the navigation lights.
Condition: Unknown
Due 26 January 2000
Resolved 26 January 2000
Fire Fighting
Issued 26 January 2000 Resolved
Provide a USCG approved Type B-I fire extinguisher. New extinguisher shallbe located at the operating station.
Condition: Unknown
Due 26 January 2000
Resolved 26 January 2000
Engineering
Issued 14 January 1999 Resolved
Prove the operation of the fuel tank shut-off valve.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Construction/Loadline
Issued 14 January 1999 Resolved
Install an indicator light at the operating station for all automatically operated bilge pumps.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Construction/Loadline
Issued 14 January 1999 Resolved
Provide a sponsoon repair kit for the vessel. The kit shall be maintained on the vessel.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Documentation
Issued 14 January 1999 Resolved
Obtain a FCC Marine Operator's permit for all vessel personnel that operatethe vessel's VHF radio._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Fire Fighting
Issued 14 January 1999 Resolved
Conduct monthly and annual servicing of all portable fire extinguishers on the vessel.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Electrical
Issued 14 January 1999 Resolved
Provide 2 portable flashlights for the vessel.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Electrical
Issued 26 January 1998 Resolved
Install corrosion resistant battery tray per 46 CFR 186.350._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 26 January 1998 Resolved
Install satisfactory set-up with shut-off valve adjacent to through hull spool piece._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Lifesaving
Issued 26 January 1998 Resolved
Provide proof of satisfactory passenger count as per 46 CFR Part 185.504._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Lifesaving
Issued 26 January 1998 Resolved
Provide proof of satisfactory passenger safety orientation briefs being conducted before each voyage per 46 CFR 185.506.._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Lifesaving
Issued 26 January 1998 Resolved
Conduct man overboard drills, firefighting drills/training, log Date of drill and training with general description of scenario and topics. Conduct and log monthly EPIRB test and survival craft maintenance; per 46 CFR 185.520/185.524/185.728/185.702._x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Lifesaving
Issued 26 January 1998 Resolved
Provide approved first aid kit as per 46 CFR Part 184.710._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Navigation
Issued 26 January 1998 Resolved
Provide updated chart, applicable section of Coast Pilot [name withheld] and Tide Tables per 46 CFR 1184.420._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Fire Fighting
Issued 26 January 1998 Resolved
Provide three (3), two-and-ahalf gallon fire buckets, labeled, with lanyards attached per 46 CFR 181.610._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Engineering
Issued 26 January 1998 Resolved
Install second means of engine control as per 46 CFR Part 184.620. There was no evidence of equipment to readily disconnect the remote engine control linkage to permit local operation.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Documentation
Issued 26 January 1998 Resolved
Provide FCC Safety Certificate per 47 CFR 80._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Documentation
Issued 26 January 1998 Resolved
Provide FCC Operators Permit for all operators of vessel as per 47 CFR 80.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Documentation
Issued 26 January 1998 Resolved
Provide stability letter per 46 CFR 176.306.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Documentation
Issued 26 January 1998 Resolved
Post Certificate of Inspection per 46 CFR 176.302.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Lifesaving
Issued 26 January 1998 Resolved
Provide proof (calculations) that the 15 person BA onboard the vessel has been correctly converted to a Life Float. Life float capacity must be 50% of vessel capacity._x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Navigation
Issued 26 January 1998 Resolved
Repair/replace vessels sounding device/horn._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Electrical
Issued 26 January 1998 Resolved
Fuse VHF radio at main distribution panel per 46 CFR 183.392._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 26 January 1998 Resolved
Install fwd bilge pump._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 26 January 1998 Resolved
Install bilge pump operation indicator for automatic and manual operation per 46 CFR 182.530._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 7 March 1995 Resolved
REPLACE THROUGH HULL NONMETALLIC FITTINGS WITH METALLIC FITTINGS OR APPROVED NONMETALLIC FITTINGS IF SUCH ARE ALLOWED BY OCMI IN AREA OF OPERATION.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Construction/Loadline
Issued 7 March 1995 Resolved
REMOVE SHARP POINTS ON SCREWS IN WAY OF TRANSOM WHERE TUBE IS ATTACHED, PORT SIDE.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Lifesaving
Issued 7 March 1995 Resolved
PREPARE VESSEL FOR INSPECTION ON ARRIVAL IN SAIPAN PRIOR TO PLACING VESSEL IN OPERATION.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995

Casualty record · 3

17 August 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4120169
7 December 2019Routine · role: Involved in a Marine Investigation (non-casualty) · activity 6869686
2 November 2021Routine · role: Involved in a Marine Casualty · activity 7345783
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record