Records from 1986 to 2001. Most recent: inspection, 18 January 2001.
Documentation record
Registered dimensions (L × B × D)43.0 ft × 12.4 ft × 3.3 ft
Registered tonnagegross 14 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderW A ALBERTSON · PORTLAND OR, UNITED STATES · built 1941
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDEPOE BAY, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itUnclassified
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
5 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
18 January 2001
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 825414
24 October 2000
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 824004
12 October 1999
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1369387
28 August 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 482
21 August 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 97365
7 June 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 806953
12 November 1998
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1429034
13 February 1998
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1112646
19 November 1997
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1392805
6 February 1997
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1390437
21 April 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 3486
21 March 1996
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1409457
17 February 1995
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1358661
17 March 1994
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 856074
24 February 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1387476
19 February 1993
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1435347
2 July 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 125992
22 April 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 956761
27 February 1992
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1270067
4 February 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1257805
7 March 1991
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 918611
19 February 1991
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1240266
10 April 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1233366
20 February 1990
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1241330
6 March 1989
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1201079
8 December 1988
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1034759
28 September 1988
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1197625
23 February 1988
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1333470
29 April 1987
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1334870
26 March 1987
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1018579
15 April 1986
Credit Drydock
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1312537
26 February 1986
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 992346
Engineering
Issued 19 November 1997
Resolved
CONDUCT OPERATIONAL TEST OF PROPULSION, STEERING, AND BILGE SYSTEM IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Navigation
Issued 19 November 1997
Resolved
PROVIDE CURRENT NAVIGATION PUBLICATIONS.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Lifesaving
Issued 19 November 1997
Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS UNDERWAY IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Lifesaving
Issued 19 November 1997
Resolved
PROVIDE FIRST AID KIT IN COMPLIANCE WITH 46 CFR 160.041.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Accommodation/Occupational Safety
Issued 19 November 1997
Resolved
MARK EXTERIOR OF FORWARD EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Navigation
Issued 24 February 1994
Resolved
MAKE EFFECTIVE REPAIRS TO STEERING LINKAGE TO REDUCE PLAY IN SWIVEL, STARBOARD SIDE.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Engineering
Issued 27 February 1992
Resolved
PROVIDE EXHAUST DUCTING FOR THE ENGINE ROOM THAT EXTEND DOWN CLOSE TO THE BILGE AND IS MADE OF FIRE PROOF MATERIAL.
Condition: Unknown
Due 27 February 1992
Resolved 27 February 1992
Engineering
Issued 27 February 1992
Resolved
SEAL THE ENGINE ROOM VENT IN THE COCKPIT AND RELOCATE IT SO THE VENT IS ABOVE THE GUNWALE.
Condition: Unknown
Due 27 February 1992
Resolved 27 February 1992
Construction/Loadline
Issued 4 February 1992
Resolved
REARRANGE LAZARETTE VENTING SO IT VENTS ABOVE GUNWALE.
Condition: Unknown
Due 3 March 1992
Resolved 3 March 1992
Construction/Loadline
Issued 4 February 1992
Resolved
INCREASE SILL HEIGHT OF COMPANION WAY DOOR TO 6 INCHES ABOVE DECK.
Condition: Unknown
Due 3 March 1992
Resolved 3 March 1992
Navigation
Issued 19 February 1991
Resolved
SHOW PROOF THAT NAVIGATION EQUIPMENT WORKS PROPERLY.
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Documentation
Issued 19 February 1991
Resolved
SUBMIT OPERATIONAL TEST FORM.
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Documentation
Issued 19 February 1991
Resolved
UNDERGO SEA TRIALS.
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Accommodation/Occupational Safety
Issued 19 February 1991
Resolved
PROPERLY STENCIL OR LOCK SHUT MSD DISCHARGE VALVE.
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Documentation
Issued 20 February 1990
Resolved
PROVIDE A COPY OF THE INLAND NAV RULES AND KEEP ON BOARD.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Construction/Loadline
Issued 20 February 1990
Resolved
MAKE VESSEL AVAILABLE FOR SEA TRIALS, ONCE BACK IN THE WATER.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Construction/Loadline
Issued 20 February 1990
Resolved
REMOVE AND TREAT FUNGI IN LOWER BILGE AREA IN THE FORWARD BERTHING AREA ANDGALLEY AREA.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Construction/Loadline
Issued 28 September 1988
Resolved
EXPAND FREEING PORT AREA TO MEET REQUIREMENTS OF 46CFR171.150 ; APPROX. 980 IN.SQ.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Construction/Loadline
Issued 28 September 1988
Resolved
MAKE LAZARETTE HATCH WATERTIGHT AS REQUIRED BY 46CFR171.124.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Construction/Loadline
Issued 28 September 1988
Resolved
PROVIDE SECURING DEVICES FOR LAZARETTE HATCH IAW 46CFR171.124(B)(1).
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Construction/Loadline
Issued 28 September 1988
Resolved
PROVIDE MEANS OF RETENTION FOR ALL DECK HATCHES IAW 46CFR171.124(B)(2).
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Construction/Loadline
Issued 26 March 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE REFASTEN HULL PLANKING ACCORDING TO APPROVED SCHEDULE AND PRESENT VESSEL FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Construction/Loadline
Issued 26 March 1987
Resolved
MAKE VESSEL AVAILABLE FOR UNDERWAY INSPECTION OF HULL INTERIOR.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Construction/Loadline
Issued 26 March 1987
Resolved
REMOVE ELECTROLYTIC ROT FROM WOOD IN WAY OF SHAFT LOG AND RENEW WITH LIKE WOOD.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987