Records from 1986 to 1994. Most recent: inspection, 8 February 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
8 February 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1163540
6 June 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 910925
8 November 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1239356
31 October 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 919823
7 June 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346109
23 June 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206362
2 June 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1201209
18 February 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1008116
8 July 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1015528
3 June 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030314
12 June 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1301760
24 April 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 985036
Accommodation/Occupational Safety
Issued 31 October 1989
Resolved
REPAIR OR REPLACE THE TWELVE HANDRAIL STANCHIONS FORWARD, SIX EACH PORT & STBE, FROM THE STANCHION BASE UPWARD TO GOOD METAL UNTIL THIS REQUIREMENT IS MET THE VESSEL MAY NOT CARRY PASSENGERS.
Condition: Unknown
Due 31 October 1989
Resolved 31 October 1989
Electrical
Issued 2 June 1988
Resolved
THERE ARE APPROXIMATELY 4 TWIST TIE CONNECTORS IN THE FORWARD STORAGE LOCKER THAT MUST BE PROPERLY SPLICED IAW 46 CFR 183.05-50(B).
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Fire Fighting
Issued 2 June 1988
Resolved
HAND BILGE/FIRE PUMP NEEDS HOSE ADDED SO THAT IT MAY REACH THE WATER SO THAT IT MAY BE USED AS A FIRE PUMP. IN ADDITION IT NEEDS A HOSE ADDED TO MEET THE FIRE HOSE REQUIREMENT AS PER 46 CFR 181.105.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Lifesaving
Issued 2 June 1988
Resolved
VSL IS SHORT ONE PFD TO MEET COI CAPACITY. PLEASE PROVIDE OR REQUEST A CHANGE TO THE COI.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Navigation
Issued 2 June 1988
Resolved
STERN LIGHT IS ONE MILE VISIBILITY TYPE VICE 2 MILE. A 2 MILE LIGHT MUST BE INSTALLED.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Construction/Loadline
Issued 18 February 1988
Resolved
RANDOMLY PULLED FASTENERS, AND RENEW MID-BODY FASTENERS BOTH SIDES OF KEEL.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Engineering
Issued 18 February 1988
Resolved
REPAIR DIESEL FUEL TANK(S) VENTS AND SCREENS. USE PROPER FASTENING DEVICE AND WIRE MESH.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Construction/Loadline
Issued 18 February 1988
Resolved
E/ROOM BILGE PLANKING. RENEW TO GOOD WOOD, THE "A" TO "C" STRAKE, BOTH SIDES OF KEEL APPROX 15 FEET LENGTH OF EACH PLANK.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Construction/Loadline
Issued 18 February 1988
Resolved
REPAIR/PLUG 3-1/8 IN PLANK ON PORT BOW AT WATERLINE.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Electrical
Issued 3 June 1987
Resolved
REMOVE ALL IMPROPER WIRE SPLICES AND SPLICE IN ACCORDANCE WITH 46 CFR 183.05-50(B).
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Fire Fighting
Issued 3 June 1987
Resolved
EXTEND EXHAUST VENT LINE IN ENGINE SPACE TO BILGE LEVEL.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Navigation
Issued 3 June 1987
Resolved
REPLACE PORT AND STARBOARD RUNNING LIGHTS WITH LIGHTS HAVING 2 MILE VISIBILITY.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Engineering
Issued 3 June 1987
Resolved
FOR ELECTRIC BILGE PUMPS: (A) INSTALL STOP OR CHECK VALVES AT THROUGH HULL PENTRATIONS, (B) INSTALL HEAVY DUTY SUPPORTED HOSE FOR DISCHARGE LINES, AND(C) INSTALL INDICATOR LIGHTS ON BRIDGE FOR AUTOMATIC PUMP.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987