Records from 1981 to 2000. Most recent: inspection, 6 August 2000.
Documentation record
Registered dimensions (L × B × D)42.1 ft × 13.5 ft × 2.8 ft
Registered tonnagegross 10 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderN P COLLINS · PANAMA CITY, FL, UNITED STATES · built 1941
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPANAMA CITY, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationNo Operation - PM · issued 26 February 1998 · expires 29 February 2000
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Gross Ton
7 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
6 August 2000
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 73694
3 August 2000
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 821452
16 March 1999
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1041286
3 March 1999
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1453550
24 November 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1436011
25 June 1997
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1443896
15 November 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427268
27 November 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1459199
11 August 1995
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1457293
31 October 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1444913
28 October 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1465179
14 October 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 834801
14 October 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1145121
10 March 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 944658
10 March 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1256463
4 December 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1223067
10 April 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 909036
7 November 1989
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 930156
14 June 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1342701
29 December 1988
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1349975
29 December 1987
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1314980
12 November 1987
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1334839
22 December 1986
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1322709
25 April 1986
Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 985671
7 November 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 976918
7 June 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277201
23 March 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1278382
25 August 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 968081
Construction/Loadline
Issued 25 June 1997
Resolved
RENEW DETERIORATED SECTIONS OF HULL PLANKING, ASSOCIATED INTERNAL FRAMING AND OTHER STRUCTURAL MEMBERS AS POINTED OUT BY THE ATTENDING MARINE INSPECTOR AS NOTED IN THE NARRATIVE SUPPLEMENT OF MSIS CASE # MI97014150.
Condition: Unknown
Due 25 June 1997
Resolved 12 September 1997
Lifesaving
Issued 7 November 1989
Resolved
REPAIR OR REPLACE 11 ADULT PFD'S.
Condition: Unknown
Due 7 November 1989
Resolved 7 November 1989
Construction/Loadline
Issued 7 November 1989
Resolved
UNDERGO A SEA TRAIL RUN PROVING OPERATION OF ALL INSTALLED EQUIPMENT.
Condition: Unknown
Due 7 November 1989
Resolved 7 November 1989
Lifesaving
Issued 7 November 1989
Resolved
STENCIL VESSEL NAME AND CAPACITY IN LETTERS AT LEAST 1.5 ON BOUYANT APPS.
Condition: Unknown
Due 7 November 1989
Resolved 7 November 1989
Lifesaving
Issued 7 November 1989
Resolved
RENEW OUTTER GRAB LINES OR REPLACE RING LIFE BUOY.
Condition: Unknown
Due 7 November 1989
Resolved 7 November 1989
Engineering
Issued 7 November 1989
Resolved
PROVE PROPER OPERATION OF REMOTE FUEL OIL EMERGENCY SHUTDOWN SWITCH.
Condition: Unknown
Due 7 November 1989
Resolved 7 November 1989
Documentation
Issued 12 November 1987
Resolved
RENEW CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 12 November 1987
Resolved 12 November 1987
Documentation
Issued 22 December 1986
Resolved
PROVIDE AND PLACE ONBOARD VALID FCC SHIP/AIRCRAFT RADIO STATION LICENSE.
Condition: Unknown
Due 22 December 1986
Resolved 22 December 1986
Construction/Loadline
Issued 22 December 1986
Resolved
REPLACE ALL FLEXIBLE ELECTRIC BILGE PIPING WITH HARD WALLED PVC SKED 40 PIPE.
Condition: Unknown
Due 22 December 1986
Resolved 22 December 1986
Construction/Loadline
Issued 22 December 1986
Resolved
PROVE PROPER OPERATION OF AFT ELECTRIC BILGE PUMP.
Condition: Unknown
Due 22 December 1986
Resolved 22 December 1986
Accommodation/Occupational Safety
Issued 22 December 1986
Resolved
VENT MSD HOLDING TANK TO OUTSIDE ATMOSPHERE AND PROVIDE 30X30 MESH FLAME SCREEN.
Condition: Unknown
Due 22 December 1986
Resolved 22 December 1986