FPS NEPTUNE is a 1996 industrial vessel. The Coast Guard has recorded 13 inspections since 2016, most recently in March 2021, along with 16 deficiencies.

Records from 2016 to 2021. Most recent: inspection, 12 March 2021.

Built
1996
Last inspected
12 March 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

420608
Flag
UNITED STATES
Maury page id
psix-420608

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

12 March 2021 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7154923
13 January 2021 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7123986
28 January 2020 Damage Survey · Administrative Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6922099
6 December 2019 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6866293
15 August 2019 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6835693
1 November 2018 Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6573683
10 August 2017 Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6235351
24 June 2017 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6201427
21 June 2017 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6186527
13 September 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5999549
5 July 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5931825
21 June 2016 Deficiency Check · Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5914033
16 June 2016 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5913179

Deficiency record · 16

09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 December 2019 Resolved
Cab mount bolts n crane are worn and wasted. Identified as needing replacement during quarterly inspection dated 30May2019 but was not rectified. Replace in kind.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2020
Resolved 9 December 2019
Resolution: Received photos that crane cab mount bolts had been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 December 2019 Resolved
Emergency generator has significant exhaust leak coming off the turbo charger. Repair leak and replace lagging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2019
Resolved 20 December 2019
Resolution: Photo evidence and statement from BS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 December 2019 Resolved
Emergency generator fuel oil supply line is dry rotted. Replace with flame resistant hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2019
Resolved 9 December 2019
Resolution: Photos received showing replacement of flexible rubber hoses for emergency generator with flame resistance designator showing.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 December 2019 Resolved
Draft Marks must be marked in contrasting color from the hull. Repaint Draft Marks. Extended 30 days due to inclimate weather.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2020
Resolved 11 May 2020
Resolution: Got photographic evidence from OIM on this date.
Electrical › Electric Supply System (service) › Cable
Issued 10 August 2017 Resolved
During inspection of lifeboat davits, MIs found plastic wire ties on davit electrical cables. Replace to the satisfaction of the attending USCG MI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 8 September 2017
Resolution: Documentation provided for closure.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 10 August 2017 Resolved
Replace all aluminum paint lockers with steel to the satisfaction of the attending USCG MI.
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 8 September 2017
Resolution: Based on email provided by [name withheld].
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 10 August 2017 Resolved
Extended to 10Oct17. RSM. Marine Inspectors reviewed both the Marine Operations Manual (MOM) and the Emergency Evacuation Plan (EEP). During the review, MI's noted that both manuals do not meet the regulation after owner/operators change. Submit corrected MOM and EEP for approval to the satisfaction of the attending USCG MI.
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 9 November 2017
Resolution: Documentation supplied [name withheld] to clear deficiency.
Operations/Management › Drills/Instruction › Using Visual Distress Signals
Issued 27 March 2017 Resolved
General alarm could not be heard over the background noise near MBF 270 1st stage scrubber area of the facility. Either add more General Alarms, or add red flashing lights. 46CFR113.25-10
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 11 April 2017
Resolution: Received official Noble Energy correspondence from company attesting that 2 speakers and a beacon have been installed at the 1st stage scrubber. Cleared 835.
Engineering › Pressure Vessel › Pressure Gauge
Issued 12 July 2016 Resolved
Fire pump nitrogen air receivers: remove iso valves upstream of releif valves; clean off stamped data plates that have been painted over.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 25 July 2016
Resolution: Data plates cleaned off, now legible. Upstream iso valves removed. Not possible to bypass relief valves.
Lifesaving › Inflatable Liferafts › Markings
Issued 12 July 2016 Resolved
Post clear launching instructions at liferaft launching stations. Mark liferaft number and persons it is permitted to accommodate in immediate vicinity. The word "liferaft" or IMO symbol shall be used to ID stowage location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2016
Resolved 25 July 2016
Resolution: Posted
Fire Fighting › Fire Main › Condition
Issued 12 July 2016 Resolved
Fire main has excessive corrosion on spar deck. Survey entire fire main to ID and rectify other areas of excessive corrosion. (Id'd 363 bolts need replacing)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 12 October 2016
Resolution: Received letter of attestation to completion of fire main repairs from Kim Farmakakis of Noble Energy. Called attending ABS Surveyor [name withheld], to verify status of repair work.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 12 July 2016 Resolved
Excessive wastage on primary escape ladder and backscratcher fall protection on column south side. Repair. mark/tape off potential hazard until repair work completed. Re-direct escape to water from only North side egress route. Replace corroded railing on spar deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 29 August 2016
Resolution: Replaced back-scatcher new and railings on spar deck. Witnessed work being performed during re-inspection/def check. ABS Surveyor [name withheld] will confirm work during next visit after tropical depression passes through.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 12 July 2016 Resolved
Renew ai rhoses on L/B#1. Markings are worn off w/ no pressure rating visible. Corrosion on fittings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 25 July 2016
Resolution: Replaced hoses in L/B#1
Lifesaving › Lifeboat › Canopy
Issued 12 July 2016 Resolved
L/B#1's retro tape on canopy is worn. Replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 25 July 2016
Resolution: replaced
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 12 July 2016 Resolved
Place 2" or taller wooden spacers beneath CO2 bottles serving MGT's to prevent corrosion.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 25 July 2016
Resolution: Placed fiberglass grating under bottles.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 12 July 2016 Resolved
Structural Fire Protection: i) mess deck exterior door has been modified. Repair/replace IAW FCP ii) Weightroom/laundry room quarters has 2 A/C units penetrating rated bulkhead. Rectify to comply w/ FCP iii)Control room door lockset removed and replaced w/ tape and door needs new gasket. Repair IAW FCP.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 9 September 2016
Resolution: [name withheld] submitted revised FCP that has spaces changed to Class-C bulkhead. [name withheld] approved FCP and sent back to Noble Energy. See Admin activity for approved FCP. Submitted FCP in documents.