Records from 1984 to 2010. Most recent: operational control imposed, 14 December 2010.
Inspection history · 96
14 December 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3910519
13 December 2010
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3909668
22 July 2009
Internal Structural Exam · Cargo Tank Internal · Drydock Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3537232
12 November 2008
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3364868
9 February 2008
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3144940
8 January 2008
Plan Review (Other than "T") · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3126805
7 January 2008
Deficiency Check · Plan Review (Other than "T")
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3125960
27 June 2007
Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2975323
22 January 2007
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2859632
18 January 2007
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2858465
10 January 2006
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2563895
27 June 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2405353
27 June 2005
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2405546
8 June 2005
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2383453
21 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2315609
24 February 2005
Deficiency Check · MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2298787
24 December 2004
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2264340
23 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2265022
6 December 2004
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2254022
4 December 2004
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2253253
4 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2266199
12 September 2004
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2194077
12 September 2004
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2366718
21 July 2004
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2140194
27 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995436
1 December 2003
Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1956564
1 March 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1751253
14 November 2002
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1705373
14 November 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1707398
7 October 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1685676
4 October 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1684302
20 August 2002
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1663517
18 April 2002
Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1606871
3 January 2001
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1457866
28 June 2000
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1408552
27 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 157770
12 April 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 817579
2 March 2000
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1046887
8 February 2000
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1045891
22 January 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 126235
22 January 2000
Examination of Repairs · Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1376043
5 January 2000
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 474918
17 November 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 815072
14 November 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 88763
14 November 1999
Damage Survey
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1361213
26 July 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 518028
14 July 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 78751
25 June 1999
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1413534
17 June 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1430704
20 January 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029683
20 January 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1336832
6 January 1999
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1442781
7 July 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 417739
3 June 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1442713
6 April 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788330
2 October 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 531512
4 September 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 447590
2 July 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 449597
27 April 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 478591
28 March 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1098845
1 March 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 503138
20 February 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 537885
17 January 1997
Hull Examination · COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1428720
15 December 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1160372
10 December 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1160547
28 January 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1138580
21 December 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 828731
26 October 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1255087
24 September 1992
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 499948
10 February 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 950452
21 January 1992
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 518245
4 November 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1004105
8 October 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1257092
14 August 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942746
21 March 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1305264
20 February 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 922699
22 June 1990
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 478351
17 November 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1223287
10 August 1989
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 538956
6 February 1989
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 440655
22 September 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1042441
28 March 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202976
31 January 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1300023
20 July 1987
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328569
20 July 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328730
5 March 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1007495
5 March 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1322316
15 January 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1011487
16 December 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1012027
21 August 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 481937
10 March 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1303132
24 February 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 994598
27 August 1985
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993304
19 April 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 467234
8 January 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 439030
17 December 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 977673
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 22 January 2007
Resolved
Small automatic auxiliary steam boiler was installed without plan review. Safeties, alarms, and controls are not IAW Part 63. Operator to provide approved plans, and test procedures, and prove proper operation of same prior to using unit.
Action required: 705 - Other - as specified
Resolved 12 November 2008
Resolution: The Periodic safety test procedures were provided by JMS 20 November 2007, and were reviewed by MSC, tested on this date and found to be IAW approved plans.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 January 2007
Resolved
OWS installed without plan approval. Provide approved plans and test procedures.
Action required: 705 - Other - as specified
Resolved 12 November 2008
Resolution: Attended vessel to inspect the oily water separator installation, found that the system was installed IAW approved plans. Operationally tested the OWS at 15 PPM tests were satisfactory.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 January 2007
Resolved
OWS discharge piping wastred and leaking IWO solenoid valve.
Condition: Improper/Lack of Maintenance
Due 22 February 2007
Resolved 22 February 2007
Resolution: Piping system replaced.
Engineering › Fuel Oil Service System › Hose
Issued 22 January 2007
Resolved
Various hose installed on engines are of improper material, or dry cracked and beyond a reasonable service life. Details are on the original CG-835.
Condition: Improper/Lack of Maintenance
Due 22 February 2007
Resolved 22 February 2007
Resolution: New hoses have been installed.
Engineering › Pressure Vessel › Relief Valve
Issued 22 January 2007
Resolved
Relief valve on lower air receiver failed to operate. Open and isolate vessel until new valve can be supplied. Prove proper operation to USCG.
Condition: Improper/Lack of Maintenance
Due 22 February 2007
Resolved 22 February 2007
Resolution: Relief valve operates properly.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 22 January 2007
Resolved
Main engine L/O pump controler missing cover. Supply cover.
Condition: Improper/Lack of Maintenance
Due 22 February 2007
Resolved 22 February 2007
Resolution: Cover installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 January 2007
Resolved
Main engine exhaust manifold cracked IWO risers. Provide repair proposal.
Condition: Improper/Lack of Maintenance
Due 22 February 2007
Resolved 22 February 2007
Resolution: Repair will be made during next dry-dock.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 22 January 2007
Resolved
AC generator fuel control jury rigged. Provide OEM controls
Condition: Improper/Lack of Maintenance
Due 22 February 2007
Resolved 22 February 2007
Resolution: Repaired the fuel controls.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 22 January 2007
Resolved
AC and stbd DC generator are missing exhaust lagging. Replace.
Due 22 February 2007
Resolved 22 February 2007
Resolution: Lagging installed.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 22 January 2007
Resolved
Engineer unable to test high water temp and low L/O pressure alarms on various engines. Provide test procedures for all generator alarms and prove same to USCG.
Due 22 February 2007
Resolved 22 February 2007
Resolution: Alarms were tested satisfactorily.
Engineering › Electric Propulsion System › Reverse Power Protection Relay Circuitry
Issued 22 January 2007
Resolved
Stbd DC generator reverse current relay failed to operate. Provide required reverse current protection.
Condition: Unknown
Due 22 February 2007
Resolved 22 February 2007
Resolution: Mechanical interlock was installed to prevent the 2 systems from being on-line at the same time.
Communications › Alarms/Indicators › High Water Alarm
Issued 22 January 2007
Resolved
Engineer unable to test high water temp alarm on the main engine. Provide test procedures for and prove same to USCG.
Due 22 February 2007
Resolved 22 February 2007
Resolution: Tested satisfactorily.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 January 2007
Resolved
Galley range, protect wires form J-box to blower.
Due 22 February 2007
Resolved 22 February 2007
Resolution: Wire is protected from heat source.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Dsicharge Nozzle
Issued 22 January 2007
Resolved
Co2 Hose reel, applicator valve handle broken. Replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2007
Resolution: Replaced handle.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 22 January 2007
Resolved
Portable extinguisher in athwart ships passage depleted. Replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2007
Resolution: Portable extinguisher has been recharged.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 January 2007
Resolved
Vessel overdue for annual/periodic inspection as required by 46 CFR 31.10-17 making the COI invalid as per 46 CFR 31.10-17a. Vessel is restricted from all movements or operations unless authorized by the local OCMI.
Due 24 January 2007
Resolved 22 January 2007
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 10 January 2006
Resolved
COFR expires 10 Jan 06. Vsl restricted from operating after midnight 10 Jan 06 until proof of valid COFR is provided to USCG.
Action required: 705 - Other - as specified
Due 11 January 2006
Resolved 10 January 2006
Fire Fighting › Fire Main › Condition
Issued 10 January 2006
Resolved
Firemain piping port side aft found ruptured. Vsl restricted from getting underway until proper repairs made to the satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 10 January 2006
Resolved 10 January 2006
Engineering › Fuel Oil Service System › Ventilation
Issued 10 January 2006
Resolved
Reinstall flame screen on stbd F/O tank vent.
Action required: 705 - Other - as specified
Due 10 January 2006
Resolved 10 January 2006
Communications › Visual Communication › Signalling Lamp
Issued 10 January 2006
Resolved
Light on EOT power failure alarm inop. Prove proper operation of light.
Action required: 705 - Other - as specified
Due 24 January 2006
Resolved 10 January 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Nozzle, Injection (fuel injection)
Issued 27 June 2005
Resolved
Prove proper operation of the MDE to the attending Coast Guard Marine Inspector prior to getting underway.
Action required: 705 - Other - as specified
Due 27 June 2005
Resolved 28 June 2005
Resolution: Witnessed operational test of the MDE - sat.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 8 June 2005
Resolved
The installed small package boiler is not approved for shipboard use. Vessel must disable the small package boiler.
Action required: 705 - Other - as specified
Due 15 June 2005
Resolved 28 June 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 December 2004
Resolved
Prior to getting underway the tanker must install a temporary port running light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2004
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 24 December 2004
Resolved
Tanker is to proceed directly to Getty Petroleum Long Island City without deviation for the purpose of discharging cargo only.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 December 2004
Resolution: Tanker arrived safely at intended destination.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 24 December 2004
Resolved
Immediately upon discharging ethanol cargo the tanker is to proceed directly to a cleaning facility for gas-freeing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2004
Resolution: Corrected.
Construction/Loadline › Structures › Superstructure
Issued 24 December 2004
Resolved
Tanker must make permanent repairs prior to resuming commercial operations.
Action required: 705 - Other - as specified
Resolved 18 June 2005
Navigation › Piloting/Steering › Marine Charts
Issued 6 December 2004
Resolved
Correct and update charts to the most recent NTM.
Due 14 December 2004
Resolved 15 December 2004
Resolution: Purchased nine Ocean Grafix updated charts through November 30, 2004.
Construction/Loadline › Structures › Door
Issued 6 December 2004
Resolved
Make engine room door watertight.
Due 14 December 2004
Resolved 15 December 2004
Resolution: Renewed gasket.
Engineering › Lubricating Oil Service System › Piping
Issued 6 December 2004
Resolved
Repair reduction gear lube oil cooler piping above the door to the steering gear.
Due 14 December 2004
Resolved 15 December 2004
Resolution: Replaced with schedule ASTM-53 stamped, schedule 40 threaded pipe.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 6 December 2004
Resolved
Repair the MDE rpm tach.
Due 22 December 2004
Resolved 15 December 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 December 2004
Resolved
Cover the exposed electrical connections for the pressure switch on the forward end of the MDE.
Due 22 December 2004
Resolved 15 December 2004
Engineering › Fuel Oil Service System › Hose
Issued 6 December 2004
Resolved
Replace the FO hose on the starboard DC generator with an approved hose and fitting.
Due 14 December 2004
Resolved 22 December 2004
Electrical › Electric Generation Source (service) › Generator
Issued 6 December 2004
Resolved
Replace the commutator cover on teh starboard DC generator.
Due 14 December 2004
Resolved 15 December 2004
Engineering › Fuel Oil Service System › Gauge
Issued 6 December 2004
Resolved
Replace the hose and mount on the FO pressure gauge on the AC generator.
Due 14 December 2004
Resolved 15 December 2004
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 6 December 2004
Resolved
Replace the cap for the reduction gear LO fill pipe.
Due 22 December 2004
Resolved 15 December 2004
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 6 December 2004
Resolved
Replace the lamps in the engine room alarm panel.
Due 14 December 2004
Resolved 22 December 2004
Fire Fighting › Fire Main › Condition
Issued 6 December 2004
Resolved
Label the fire pump controller in the engine room and the start/stop switches.
Due 14 December 2004
Resolved 15 December 2004
Fire Fighting › Fire Pumps › Gland Sealing
Issued 6 December 2004
Resolved
Tighten or replace the packing of the fire pump.
Due 14 December 2004
Resolved 15 December 2004
Resolution: Packing added to the seal.
Construction/Loadline › Hull › Keel
Issued 6 December 2004
Resolved
Replace the flex hose on the four keel coolers with either solid pipe or an approved non-metallic hose.
Due 22 December 2004
Resolved 22 December 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 December 2004
Resolved
Remove or mount the duplex recepticle on the MDE LO cooler.
Due 14 December 2004
Resolved 15 December 2004
Resolution: Removed.
Electrical › Electric Supply System (service) › Cable
Issued 6 December 2004
Resolved
Install metallic wire hangers in accordance with IEEE (every 24 inches) in the engine room overhead.
Due 22 December 2004
Resolved 22 December 2004
Engineering › Fuel Oil Service System › Hose
Issued 6 December 2004
Resolved
Replace the LO hose and mount the LO pressure gauge on the port DC generator.
Due 14 December 2004
Resolved 22 December 2004
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 December 2004
Resolved
Prove proper operation of the oily water seperator prior to use.
Action required: 705 - Other - as specified
Due 22 December 2004
Resolved 28 June 2005
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 6 December 2004
Resolved
Post the stability letter under glass.
Due 14 December 2004
Resolved 15 December 2004
Engineering › Steering Gear System › Linkage
Issued 4 December 2004
Resolved
Determine the cause of the steering gear coupling failure and make repairs to the satisfaction of the attending CG inspector.
Action required: 705 - Other - as specified
Due 4 December 2004
Resolved 6 December 2004
Engineering › Steering Gear System › Motor
Issued 12 September 2004
Resolved
Vessel must demonstrate the proper operation of the steering gear motor before getting underway. Request for deadship tow denied.
Action required: 705 - Other - as specified
Resolved 13 September 2004
Resolution: Witnessed sat test of steering gear.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 September 2004
Resolved
Make repairs to the steering gear cable run by providing enough slack in the cable to properly mount.
Due 20 September 2004
Resolved 20 September 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 12 September 2004
Resolved
Make permanent repairs to the lighting circuit in the steering gear room (re-connect the cable).
Due 20 September 2004
Resolved 20 September 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 September 2004
Resolved
Make repairs to the WTB between the E/R and steering gear room (weld up the hole IWO steering gear cable penetrations).
Due 20 September 2004
Resolved 20 September 2004
Fire Fighting › Fire Hydrants
Issued 1 December 2003
Resolved
Replace fire hose box on fwd end of vsl, or make permanent repairs to hinges. LEGACY COMPONENT DESC: Condition
Due 23 December 2003
Resolved 2 December 2003
Deck/Cargo › Cargo Stowage
Issued 1 December 2003
Resolved
Replace flame screens IWO #1 P/S PV's and #4S ullage gauging. LEGACY COMPONENT DESC: Flame Screens
Due 1 December 2003
Resolved 2 December 2003
Deck/Cargo › Cargo Stowage
Issued 1 December 2003
Resolved
Replace gasket IWO #1S ullage gauging cover. LEGACY COMPONENT DESC: Gasket
Due 1 December 2003
Resolved 2 December 2003
Lifesaving › Rescue Boat
Issued 1 December 2003
Resolved
Replace P/S embarkation ladders. LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Due 8 December 2003
Resolved 7 January 2004
Resolution: Witnessed replacement of embarkation ladders.
Lifesaving › Lifebuoys
Issued 1 December 2003
Resolved
Replace port wheel house life ring and water light. LEGACY COMPONENT DESC: Self-igniting Lights
Due 8 December 2003
Resolved 2 December 2003
Electrical › Electric Supply System (service)
Issued 1 December 2003
Resolved
Remove dead end wires in galley and remove brown electrical cord behind refer. LEGACY COMPONENT DESC: Cable
Due 23 December 2003
Resolved 2 December 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 1 December 2003
Resolved
Make permanent repairs to paint locker.
Due 23 December 2003
Resolved 7 January 2004
Resolution: Witnessed repair of holes in paint locker.
Engineering › Lubricating Oil Storage/Transfer System
Issued 1 December 2003
Resolved
Repair hydraulic leak at union under port cargo pump engine. LEGACY COMPONENT DESC: Piping
Due 23 December 2003
Resolved 2 December 2003
Accommodation/Occupational Safety › Messroom
Issued 1 December 2003
Resolved
Repair port lights in galley port and starboard sides.
Due 23 December 2003
Resolved 7 January 2004
Resolution: Witnessed repair of lights.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 1 December 2003
Resolved
Properly enclose block heater electrical box in upper engine room.
Due 23 December 2003
Resolved 7 January 2004
Resolution: Witnessed proper repair of block heater box.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 December 2003
Resolved
C/R wasted sections of deck rail port side fwd. LEGACY COMPONENT DESC: Deck Rail
Due 30 June 2004
Resolved 18 January 2005
Engineering › Generator (propulsion/auxiliary-electric)
Issued 1 December 2003
Resolved
Double clamp hose connections on A/C generator.
Due 15 December 2003
Resolved 2 December 2003
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 1 December 2003
Resolved
Replace missing bolts on stbd DC generator mount.
Due 15 December 2003
Resolved 1 December 2003
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 1 December 2003
Resolved
Propperly install lagging on stbd DC generator exhaust. LEGACY COMPONENT DESC: Piping (exhaust)
Due 15 December 2003
Resolved 2 December 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 1 December 2003
Resolved
Install splash guard on main engine, IVO switchboard.
Due 1 December 2003
Resolved 2 December 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 1 December 2003
Resolved
Remove oil and water from engine room bilges.
Due 15 December 2003
Resolved 7 January 2004
Resolution: Witnessed proper removal of oil and water from bilge
Engineering › Bilge Water Management System
Issued 1 December 2003
Resolved
Prover proper operation of bilge pumps (both power and pnuematic) in the presence of USCG [name withheld]: Pump
Due 15 December 2003
Resolved 20 January 2004
Resolution: Rcvd statement from master that bilge pump had been tested and bilge strainers inspected.
Engineering › Bilge Water Management System
Issued 1 December 2003
Resolved
Remove water from steering compartment.
Due 15 December 2003
Resolved 2 December 2003
Navigation › Emergency Steering
Issued 1 December 2003
Resolved
Prover proper operation of emergency steering gear.
Due 1 December 2003
Resolved 2 December 2003
Engineering › Compressed Air System (start air)
Issued 1 December 2003
Resolved
Remove old compressor from engine room. LEGACY COMPONENT DESC: Compressor
Due 15 December 2003
Resolved 7 January 2004
Resolution: Witnessed removal of old compressor.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 1 December 2003
Resolved
Remove foreign material from exhaust lagging on port DC gen. LEGACY COMPONENT DESC: Piping (exhaust)
Due 15 December 2003
Resolved 2 December 2003
Electrical › Lighting (service)
Issued 1 December 2003
Resolved
Make permanent repairs to light fixture above lube oil filter on port side. LEGACY COMPONENT DESC: Outlet Box
Due 15 December 2003
Resolved 7 January 2004
Resolution: Witnessed repair to light fixture.
Fire Fighting › Fire Pumps
Issued 1 December 2003
Resolved
Replace pakcing on fire pump. LEGACY COMPONENT DESC: Pumpshaft
Due 15 December 2003
Resolved 2 December 2003
Electrical › Electrical Distribution System (service)
Issued 1 December 2003
Resolved
Replace electrical receptacle fwd of boiler with approved type/or remove. LEGACY COMPONENT DESC: Outlet Box
Due 15 December 2003
Resolved 7 January 2004
Resolution: Witnessed replacement of outlet box.
Electrical › Electrical Distribution System (service)
Issued 1 December 2003
Resolved
Proper terminate dead end wires behind switchboard. LEGACY COMPONENT DESC: Switchboard
Due 15 December 2003
Resolved 7 January 2004
Resolution: Witnessed proper termination of dead end wires.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 1 December 2003
Resolved
Replace valve on pre-lube pump line (no gate).
Due 15 December 2003
Resolved 2 December 2003
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 1 December 2003
Resolved
Replace missing exhaust pipe lagging on boiler. LEGACY COMPONENT DESC: Exhaust
Due 15 December 2003
Resolved 7 January 2004
Resolution: Witnessed installation of new lagging.
Navigation › Piloting/Steering
Issued 1 December 2003
Resolved
Provide copy of most recent steering gear system overhaul to USCG.
Due 1 December 2003
Resolved 2 December 2003
Engineering › Diesel Engine (auxiliary)
Issued 1 December 2003
Resolved
Repair/Replace leaking fuel piping for port cargo pump engine. LEGACY COMPONENT DESC: Distributor (fuel injection)
Due 1 December 2003
Resolved 2 December 2003
Navigation › Piloting/Steering
Issued 1 December 2003
Resolved
Provide technician report verifying proper operation on steering system (ram movement, tightening of bolts) to USCG.
Due 1 December 2003
Resolved 1 December 2003
Engineering › Steering Gear System
Issued 1 December 2003
Resolved
Submit repair proposal regarding the permanent repairs of main engine mojnt and steering gear system cracks. LEGACY COMPONENT DESC: Fastener
Due 1 December 2003
Resolved 2 December 2003
Resolution: Discussed with [name withheld] during meeting at ACTNY and verified cracking was self arrested and did not weaken structural feet (dye pen tested).
Construction/Loadline › Hull
Issued 14 November 2002
Resolved
Proceed directly to cleaning facility and make vessel gas free, and available for inspection. Make permanent repairs to C.T. 4P to satisfaction of [name withheld]: Bottom Plating
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2002
Construction/Loadline › Hull
Issued 14 November 2002
Resolved
C/R damaged plate (3 areas) min 18"X30" iwo DD block #2, stbd side. LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2002
Construction/Loadline › Hull
Issued 14 November 2002
Resolved
C/R stbd/port side keel plate iwo Block #4, min 18"X30" insert. LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2002
Construction/Loadline › Hull
Issued 14 November 2002
Resolved
C/R Bottom plate iwo block #5, port side. Min 18"X 30". LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2002
Construction/Loadline › Hull
Issued 14 November 2002
Resolved
Make available for internal inspection all damaged areas listed and keel plating iwo block #5 (stbd side); Bottom plating gouge between blocks #4, #5 (stbd side)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2002
Navigation › Piloting/Steering
Issued 6 September 2002
Resolved
Provide valid compass deviation table LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 8 October 2002
Resolution: Provided table
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 September 2002
Resolved
Prove proper operation of engine tachometer for MDE.
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 8 October 2002
Resolution: Proved proper operation.
Electrical › Electrical Distribution System (service)
Issued 6 September 2002
Resolved
Replace cover on electrical junction box on stbd generator; also install guard over belt. LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 8 October 2002
Resolution: Installed both covers.
Engineering › Freshwater System (piston cooling)
Issued 6 September 2002
Resolved
Repair cooling water leak on port generator LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 8 October 2002
Resolution: repaired
Accommodation/Occupational Safety › Occupational Safety
Issued 6 September 2002
Resolved
Install deck plate hand hole cover outboard side (stbd) red gear. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 8 October 2002
Resolution: Installed
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 September 2002
Resolved
Prove proper operation of air gauge on local MDE control station
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 8 October 2002
Resolution: Tested-sat
Accommodation/Occupational Safety › Occupational Safety
Issued 6 September 2002
Resolved
Repair hand rail iwo focsle deck aft, stbd side. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 8 October 2002
Resolution: Repaired
Engineering › Bilge Water Management System
Issued 6 September 2002
Resolved
Provide diagram of bilge piping system and fire main system in E/R. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 8 October 2002
Engineering › Bilge Water Management System
Issued 6 September 2002
Resolved
Provide aditional pump (total of 2) for service as emergency bilge pump. Pump must tie into main bilge suction line in E/R and have capacity of 400 ft/min. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 8 October 2002
Electrical › Electrical Distribution System (service)
Issued 6 September 2002
Resolved
Replace electrical junction box iwo C.T. #1 stbd wih intrisically safe (explosion proof) type. To be cleared prior to cargo ops. LEGACY COMPONENT DESC: Junction Box
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2002
Resolved 6 September 2002
Resolution: Received fax showing purchase of intrisically safe box with confirmation of owner installation.
Lifesaving
Issued 2 March 2000
Resolved
Prove proper operation of stbd ring bouy light.
Condition: Unknown
Due 3 April 2000
Resolved 2 March 2000
Lifesaving
Issued 2 March 2000
Resolved
Provide damage stability information IAW 33 CFR 155.240. Meeting the requirements of 33 CFR 155.245 will be accepted in lieu of the previous.
Condition: Unknown
Due 2 March 2000
Resolved 2 March 2000
Deck/Cargo
Issued 2 March 2000
Resolved
Port anchor brake band is severely wasted. Renew brake band to satisfactionof USCG inspector.
Condition: Unknown
Due 2 March 2000
Resolved 2 March 2000
Construction/Loadline
Issued 22 January 2000
Resolved
GAS-FREE VSL AND MAKE PERMANENT REPAIRS TO CRACK IN #3-P CARGO TANK TO SATISFACTION OF THE ATTENDING MARINE INSPECTOR. REPAIRS MUST BE MADE PRIORTO CONDUCTAND ANY COMMERCIAL OPERATIONS.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Navigation
Issued 14 November 1999
Resolved
HAVE STEERING TESTED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 16 November 1999
Resolved 17 November 1999
Lifesaving
Issued 14 November 1999
Resolved
VESSEL MUST HAVE A TUG BOAT IN ATTENDANCE UNTIL VESSEL IS MADE FAST TO FINAL MOORING AT STATEN ISLAND.
Condition: Unknown
Due 14 November 1999
Resolved 17 November 1999
Accommodation/Occupational Safety
Issued 6 January 1999
Resolved
PROPVE PROPER OPERATION OF VESSELS MSD SYSTEM. TO BE USED AS A TYPE III ONLY UNTIL TYPE II UNIT IS REPAIRED.
Condition: Unknown
Due 6 January 1999
Resolved 6 January 1999
Lifesaving
Issued 6 January 1999
Resolved
PROPERLY EMERGENCY MUSTER STATION FOR LIFE RAFT AND RESCUE BOATS
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Construction/Loadline
Issued 6 January 1999
Resolved
PROPERLY PLUG HOLE IN WT BULK TO AFT STEERING
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Accommodation/Occupational Safety
Issued 6 January 1999
Resolved
PROPERLY LABEL AND CLEAR EMERGENCY EXIT FROM ENGINE ROOM
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Accommodation/Occupational Safety
Issued 6 January 1999
Resolved
INSTALL MISSING GUARD ON MAIN ENGINE POWER TAKEOFF FOR RAW WATER COLLING PUMP DRIVE
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Construction/Loadline
Issued 6 January 1999
Resolved
REPAIR WT DOOR DOG TO AFT STEERING FLAT
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Engineering
Issued 6 January 1999
Resolved
REPAIR EXHAUST LEAK ON STBD DC GENERATOR SET
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Navigation
Issued 6 January 1999
Resolved
PROPERLY INSTALL PORT WRIST PIN ON STEERING GEAR
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Electrical
Issued 6 January 1999
Resolved
INSTALL METAL WIRE STRAPS IN LIEU OF PLASTIC ZIP TIES THROUGHOUT ENGINE ROOM
Condition: Unknown
Due 6 January 1999
Resolved 6 January 1999
Electrical
Issued 6 January 1999
Resolved
INSTALL PROPER COVERS AND CONNECTORS ON ALL WIRING JUNCTION BOXES THROUGHOUT ENGINE ROOM
Condition: Unknown
Due 6 January 1999
Resolved 6 January 1999
Electrical
Issued 6 January 1999
Resolved
INSTALL PROPER CONNECTIONS ON BATTERY CABLES FOR AC GENERATOR
Condition: Unknown
Due 6 January 1999
Resolved 6 January 1999
Engineering
Issued 6 January 1999
Resolved
INSTALL MISSING LAGGING ON VESSELS OIL FIRED HEATING BOILER UPTAKE
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Engineering
Issued 6 January 1999
Resolved
REPAIR/REMOVE INOP TACHS ON BOTH DC GEN SETS
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Engineering
Issued 6 January 1999
Resolved
INSTALL MISSING BOLTS IN BRUSH COVERS ON BOTH DC GEN SETS
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Electrical
Issued 6 January 1999
Resolved
INSTALL MISSING GUARD ON LIGHT OVER WORKBENCH
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Fire Fighting
Issued 6 January 1999
Resolved
PROPERLY STENCIL VESSEL'S NAME ON FIRE AXE IN PILOTHOUSE
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Accommodation/Occupational Safety
Issued 6 January 1999
Resolved
REPAIR AIR START FLASK RELIEF VALVES
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Engineering
Issued 6 January 1999
Resolved
PROVE PROPER OPERATION OF MAIN ENGINE OVERSPEED TRIP
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Navigation
Issued 6 April 1998
Resolved
PROVIDE SHIP'S BELL
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Construction/Loadline
Issued 6 April 1998
Resolved
REPLACE WASTED PIPING BETWEEN SEA CHEST AND STRAINER TO FIRE PUMP
Condition: Unknown
Due 6 April 1998
Resolved 7 April 1998
Engineering
Issued 6 April 1998
Resolved
REMOVE OR MAKE OPERABLE TACHOMETERS ON OUTBOARD D/C GENERATORS
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Engineering
Issued 6 April 1998
Resolved
REPAIR EXCESS FLOW OF WATER FROM TAILSHAFT PACKING IWO AFT ENGINE ROOM BULKHEAD
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Electrical
Issued 6 April 1998
Resolved
REPLACE STARBOARD LIGHT BULB & INSTALL GLOBE AND INSTALL GUARDS ON BOTH PORT & STARBOARD LIGHTING FIXTURES IN STEERING COMPARTMENT
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Electrical
Issued 6 April 1998
Resolved
INSTALL COVERPLATE ON SWITCHBOX TO SANITARY PUMP & INSTALL CABLE PLUG
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Accommodation/Occupational Safety
Issued 6 April 1998
Resolved
REPAIR COVER TO MSD TANK, INSTALL ALL MISSING STUDS & NUTS.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Engineering
Issued 6 April 1998
Resolved
INSTALL FLAME SCREENS IN LUBE OIL TANK VENT PIPING PORT/STARBOARD
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Electrical
Issued 6 April 1998
Resolved
MAKE OPERABLE AND PROVE PROPER OPERATION OF MAIN DIESEL ENGINE SHAFT DRIVEND/C GENERATOR
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Electrical
Issued 6 April 1998
Resolved
INSTALL NEW GROUND FAULT LIGHT FOR #1 D/C GENERATOR ON MAIN SWITCHBOARD
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Electrical
Issued 6 April 1998
Resolved
CLEAN OUT ALL METAL OBJECTS FROM EMERGENCY BATTERY TRAY
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Electrical
Issued 6 April 1998
Resolved
REMOVE PORTABLE BATTERY CHARGER FOR A/C GENERATOR & RENEW WITH U/L LISTED MARINE CHARGER
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Accommodation/Occupational Safety
Issued 6 April 1998
Resolved
PROVE PROPER OPERATION OF PRESSURE RELIEF VALVE ON FRESH WATER TANK
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Accommodation/Occupational Safety
Issued 6 April 1998
Resolved
PROVE PROPER MAWP OF AIR RECEIVERS IN ENGINE ROOM
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Accommodation/Occupational Safety
Issued 6 April 1998
Resolved
REPAIR EXHAUST LEAK IN OIL FIRED STOVE EXHAUST VENT IN GALLEY
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Engineering
Issued 6 April 1998
Resolved
REPAIR EXHAUST LEAK ON STARBOARD D/C GENERATOR EXHAUST PIPING
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Lifesaving
Issued 6 April 1998
Resolved
RENEW LINES ON BOTH AFT RING BUOYS
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Fire Fighting
Issued 6 April 1998
Resolved
PROVE PROPER CLOSURE OF #1 & #2 FIRE STATION VALVES
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Accommodation/Occupational Safety
Issued 6 April 1998
Resolved
PROVIDE SCREENS FOR GALLEY PORT HOLES & OVERHEAD VENT
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Engineering
Issued 6 April 1998
Resolved
PROVIDE NEW LAGGING FOR PORT D/C GENERATOR EXHAUST
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Navigation
Issued 6 April 1998
Resolved
PROVE PROPER OPERATION OF NAVIGATION LIGHT PANEL AUDIBLE ALARM
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Lifesaving
Issued 6 April 1998
Resolved
REMOVE BUCKETS FROM ENTRY TO PUMP ROOM STARBOARD SIDE
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Deck/Cargo
Issued 6 April 1998
Resolved
REPAIR PORT ANCHOR BRAKE AND TEST BOTH ANCHORS
Condition: Unknown
Due 6 April 1998
Resolved 7 April 1998
Construction/Loadline
Issued 6 April 1998
Resolved
REPAIR FOREPEAK RAILINGS
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Accommodation/Occupational Safety
Issued 6 April 1998
Resolved
PROVIDE SCREENS FOR ACCOMMODATION SPACES
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Lifesaving
Issued 6 April 1998
Resolved
MAKE PROPER DECK MARKINGS FOR BENZENE PROGRAM AND PROVIDE PROOF OF CERTIFIED MARINE CHEMIST SURVEY
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Accommodation/Occupational Safety
Issued 17 January 1997
Resolved
Prove proper operation of MSD type II or type III._x001C_
Condition: Unknown
Due 17 February 1997
Resolved 31 March 1997
Construction/Loadline
Issued 17 January 1997
Resolved
Crop and renew bent section of forward bulwark._x001C_
Condition: Unknown
Due 17 January 1997
Resolved 17 January 1997
Deck/Cargo
Issued 17 January 1997
Resolved
Mark oil transfer hose "OIL SERVICE ONLY" and "MAWP....psi"_x001C_
Condition: Unknown
Due 17 February 1997
Resolved 31 March 1997
Navigation
Issued 17 January 1997
Resolved
Provide compass deviation card.
Condition: Unknown
Due 17 February 1997
Resolved 31 March 1997
Construction/Loadline
Issued 17 January 1997
Resolved
Provide guard on stern tube bilge pump._x001C_
Condition: Unknown
Due 17 February 1997
Resolved 31 March 1997
Electrical
Issued 17 January 1997
Resolved
Provide metal ties on wiring by MG set in upper engine room._x001C_
Condition: Unknown
Due 17 February 1997
Resolved 31 March 1997
Construction/Loadline
Issued 17 January 1997
Resolved
Prove proper operation of forward bilge pump._x001C_
Condition: Unknown
Due 17 February 1997
Resolved 31 March 1997
Accommodation/Occupational Safety
Issued 17 January 1997
Resolved
Hard wire berthing lighting in [name withheld] room._x001C_
Condition: Unknown
Due 17 February 1997
Resolved 31 March 1997
Electrical
Issued 17 January 1997
Resolved
Properly mount wiring on port bulkhead of fidley using metallic fasteners and clamps.
Condition: Unknown
Due 17 February 1997
Resolved 31 March 1997
Deck/Cargo
Issued 17 January 1997
Resolved
Install anchor chain pike (anti knoting bar).
Condition: Unknown
Due 17 February 1997
Resolved 31 March 1997
Electrical
Issued 26 October 1992
Resolved
PROVE PROPER OPERATION OF AC GENERATOR, DC GENERATOR, AND DC GENERATOR TACHOMETER. THESE ITEMS TO BE COMPLETED TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 26 October 1992
Resolved 26 October 1992
Construction/Loadline
Issued 31 January 1988
Resolved
CROPPED & RENEWED 15'X4' & 12'X4' SECTIONS OF WASTED PLATE (C+D STRAKES) INWAY OF THE PORT SIDE OF THE ENGINE ROOM BETWEEN THE AFT BULKHEAD & 2ND TRANSVERSE FRAME FORWARD OF THE BULKHEAD.
Condition: Unknown
Due 31 January 1988
Resolved 31 January 1988
Construction/Loadline
Issued 31 January 1988
Resolved
PROVIDE A COPY OF THE MARCH 1988 GAUGING REPORT ALONG WITH VESSEL PLANS SHOWING ORIGINAL SCANTLINGS.
Condition: Unknown
Due 31 January 1988
Resolved 31 January 1988
Construction/Loadline
Issued 20 July 1987
Resolved
MAKE THE DOORS WATERTIGHT AND DOGS OPERATIONAL FOR THE FOLLOWING SPACES: A. FORWARD MACHINERY SPACE B. PUMP ROOM (PORT & STBD SIDE)
Condition: Unknown
Due 20 July 1987
Resolved 20 July 1987
Fire Fighting
Issued 16 December 1986
Resolved
PROVIDE SUITABLE FIRE EXTINGUISHING SYSTEM FOR CARGO TANKS (46 CFR 34.05-5 (A)(2)). THIS MAY INCLUDE STEAM SMOTHERING, FIXED FOAM OR CO2 SYSTEM, A DECK FOAM SYSTEM OR INSTALLATION OF A BV EXTINGUISHER.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Fire Fighting
Issued 16 December 1986
Resolved
REPLACE OR HYDROSTATICALLY TEST FIRE EXTINGUISHER 394458 (30 LB. DRY CHEM IN GALLEY) AND FIRE EXTINGUISHER 107153 (10 LB. DRY CHEM IN LOWER ENGINE ROOM).
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Deck/Cargo
Issued 16 December 1986
Resolved
TEST CARGO PIPING TO A MINIMUM OF 225 PSI. PROVIDE U.S. COAST GUARD A COPY OF THE RESULTS. 33 CFR 156.170(C)(4).
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Electrical
Issued 16 December 1986
Resolved
REPLACE HOUSEHOLD TYPE JUNCTION BOXES WITH WATERTIGHT JUNCTION BOXES.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Electrical
Issued 16 December 1986
Resolved
REPLACE SWITCHES/CONTROLLERS THAT ARE NOT DRIPPROOF WITH DRIPPROOF STYLE.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Electrical
Issued 16 December 1986
Resolved
REPLACE HOUSEHOLD STYLE RECEPTABLE WITH MARINE TYPE WATERTIGHT FIXTURES.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Construction/Loadline
Issued 16 December 1986
Resolved
PROVIDE STUFFING TUBES FOR ALL BULKHEAD CABLE PENETRATIONS.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Navigation
Issued 16 December 1986
Resolved
PROVIDE LOCAL RUDDER ANGLE INDICATOR IN AFTER STEERING.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Electrical
Issued 24 February 1986
Resolved
INSTALL COVERS ON TWO ELECTRICAL JUNCTION BOXES IN ENGINE ROOM, ONE FOR BOILER CONTROLS AND ONE FOR LIGHTING SYSTEM.
Condition: Unknown
Due 24 February 1986
Resolved 24 February 1986
Electrical
Issued 24 February 1986
Resolved
RENEW ELECTRICAL MATTING IN REAR OF MAIN SWITCHBOARD IN ENGINE ROOM.
Condition: Unknown
Due 24 February 1986
Resolved 24 February 1986
Fire Fighting
Issued 24 February 1986
Resolved
PLACE ON BOARD 2 SETS OF PROTECTIVER CLOTHING THAT MEET THE REQUIREMENTS OF 46 CFR 35.30-20(C)(7).
Condition: Unknown
Due 24 February 1986
Resolved 24 February 1986
Fire Fighting
Issued 24 February 1986
Resolved
PLACE ON BOARD ONE ADDITIONAL FRESH AIR BREATHING APPARATUS OR SCBA AS REQUIRED BY 46 CFR 35.30-20.
Condition: Unknown
Due 24 February 1986
Resolved 24 February 1986
Electrical
Issued 24 February 1986
Resolved
INSTALL PROTECTIVE GUARD OVER RUNNING INDICATOR LIGHT ON THE D.C.M.G. SET IN ENGINE ROOM.
Condition: Unknown
Due 24 February 1986
Resolved 24 February 1986
Fire Fighting
Issued 24 February 1986
Resolved
INSTALL ON BV FIRE EXTINGUISHER (DOUBLE IF CO2 OR DC) FOR CARGO DECK AREA FIRE PROTECTION COMPLETE BY NEXT GAS FREE BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 24 February 1986
Resolved 24 February 1986