BAHIA BELLE

BAHIA BELLE is a 1942 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2017, most recently in February 2025, along with 32 deficiencies and 6 casualty investigations between 2006 and 2022.

Records from 2006 to 2025. Most recent: inspection, 21 February 2025.

Built
1942
Last inspected
21 February 2025
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WAM8246
Flag
UNITED STATES
Maury page id
psix-42080

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded3
Years with a record 9 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)61.5 ft × 24.0 ft × 4.1 ft
Registered tonnagegross 50 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSAN DIEGO CA · built 1942
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 20

21 February 2025 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8082578
27 February 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7896204
8 May 2023 Deficiency Check · Annual Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7694898
31 January 2023 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7629624
21 July 2022 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7513609
21 July 2022 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7513903
25 April 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7438031
25 April 2022 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7443934
23 April 2022 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7444150
2 March 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7404470
15 June 2021 Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7228550
13 June 2021 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7253614
11 January 2021 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7122636
30 November 2020 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7103807
16 September 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7067985
10 March 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6924214
9 January 2019 Hull Examination · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6606861
27 February 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6362477
14 March 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6104435
5 January 2017 Deficiency Check · Hull Examination · Internal Structural Exam · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6066609

Deficiency record · 32

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 May 2023 Resolved
Pre-engineered fixed gas fire extinguishing system must: (3) automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Genset is not connected to fireboy system, ensure genset is connected to fireboy system and shuts down upon activation.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2023
Resolved 9 May 2023
Resolution: Connected GENSET to fireboy controller IAW manufacturers instructions
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 May 2023 Resolved
Each vessel must be provided with bilge pumps IAW 56.50-55 in subchapter F. Risk has been mitigated with portable pumps on board in addition to vessel being limited to Mission Bay. O/O reported Bilge pump was inoperable and being replaced in kind. Verify install and test in presence of an MI
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 May 2023
Resolution: Power Pump replaced; witnessed operational test & dewatered Port Engine space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 July 2022 Resolved
Ships Service Diesel Generator unexpectedly shut down due to overheat from coolant leaks and damaged raw water impeller. Provide Report of findings and generator components serviced and repaired for review to the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2022
Resolved 25 July 2022
Resolution: SoCal Boat Works - pressure tested prime mover w/ no coolant leaks detected. Raw water impeller was worn down and seized which resulted in an overheating of jacket water and subsequent unexpected shutdown as the cause. Raw water impeller replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 July 2022 Resolved
Upon loss of generator power, ships throttle controls became inoperable due to a loss of power. Electrician states throttles are powered directly to a battery charger versus the batteries which loses power upon loss of generator. Submit 1 line electrical diagram of current configuration of throttle wiring in addition to a proposed 1 line diagram of throttle installation to ensure batteries are the source of power of throttle control and will not be subject to loss during a disruption of power.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2022
Resolved 25 July 2022
Resolution: SoCal Boat works licensed Electrician submitted updated 1-line diagram that will be used to re-wire throttles to triple battery bank in E/R deticated to throttle controls in addition to battery charger deticated to charging throttle control batteries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2022 Resolved
Based on objective evidence that the throttle controls have not been installed correctly or operating within manufacturers standards. vessel is required to submit a Qualitative Failure Analysis and Design Verification Testing Procedure obtained by throttle manufacturer to USCG Marine Safety Center for review and approval.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2022
Resolved 25 July 2022
Resolution: Owner rep [name withheld] provided ZF MicroCommander manufacturers installation procedures in addition to testing procedures. Conducted dock trial tests and sea trial tests IAW manufacturers procedures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 April 2022 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Vessel experienced generator shut-down while underway due to loose connection of fuse for fuel pump/injectors. Must conduct trouble-shooting of the entire electrical generation and make necessary repairs to the satisfaction of Coast Guard Marine Inspector prior to getting underway with passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2022
Resolution: Def resolved, received tech report.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 April 2022 Resolved
All vessels shall be provided with suitable steering apparatus. Vessel was intentionally grounded by master upon discovery of generator casualty that impacted sections around rudder stocks. Operator must conduct survey of condition of rudders and all rudder components to the satisfaction of the Coast Guard Marine Inspector prior to getting underway with passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 April 2022 Resolved
Electrical Equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Vessels generator failed and is inoperable. Troubleshoot and repair as needed. Conduct satisfactory operation test in the presence of a USCG marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2022
Resolved 25 April 2022
Resolution: Vessel O/O has repaired generator and inservice inspection was conducted with missle case #7438031.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 March 2022 Resolved
Main deck salon forward and aft smoke detector failed self- test. Repair / replace
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 March 2022
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
Main deck Forward pantry overhead light fixture missing its diffuser.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 March 2022
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2022 Resolved
Port side life ring Buoy lifeline weathered. Replace.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 March 2022
Resolved 18 March 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
Main deck salon Portside wall light sconces; light fixture loose; Install hardware to secure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 March 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
Engine room Portside transformer unit front cover plate missing hardware. Install and secure plate cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 March 2022
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 March 2022 Resolved
Fire main suction supply pipe not properly secured in bracket; Repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 March 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
Fire pump motor controller front cover not missing securing hardware; repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 March 2022
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 March 2022 Resolved
Fire pump discharge pressure gauge; not properly displaying static and dynamic pressure during operational test; Repair / replace gauge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 16 March 2022
Resolution: Replaced PSI gauge and operational test SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
Port and STBD MDE start battery storage cover not secured in place; provide securing means / straps.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 March 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
Port & STBD MDE electrical starter knife switch exposed; not properly enclosed to prevent personnel contact.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2022
Resolved 19 April 2022
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
Port Engine shaft stern tube; electrical junction box not properly secured in place; repair.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 March 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 2 March 2022 Resolved
Saloon deck Port and STBD aft staircase; center rails loose at securing points. Repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 March 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
Saloon deck portside forward wall sconce light fixture loose; repair / replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 March 2022
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
Saloon deck aft special lighting STBD end fixture not properly secured. Repair / replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 March 2022
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 March 2022 Resolved
Saloon deck smoke detector failed self- test; repair / replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 March 2022
Resolution: corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 March 2022 Resolved
Operating station Bilge alarm unit failed during audible test. Repair / replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 March 2022
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 15 June 2021 Resolved
STBD steering ram mount sheared off main longitudinal deck beam support in steering compartment causing a reduction in vessel steering capabilities. Must submit repair proposal for longitudinal deck beam to OCMI for approval, conduct necessary repairs to deck beam, re-mount steering ram and conduct steering tests to the satisfaction of the attending CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2021
Resolution: Verified by attending MIs...[name withheld]
Fire Fighting › Fire Main › Material
Issued 14 March 2017 Resolved
Provide bracket to properly support fire main piping in port engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 14 March 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 March 2017 Resolved
Properly seal electrical junction boxes.
Condition: Improper/Lack of Maintenance
Due 14 April 2017
Resolved 14 March 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 14 March 2017 Resolved
Provide proper install to loose light fixture in the stbd engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 14 March 2017
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 14 March 2017 Resolved
Propvide proper install to battery box covers in both engine rooms.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 14 March 2017
Stability › Unintentional Flooding › General
Issued 5 January 2017 Resolved
Remove excess water and dry chem from E/R Bilges
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 5 January 2017 Resolved
Renew lagging on Stbd engine
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 January 2017 Resolved
Prove proper operation of engines via sea trial with Coast Guard personnel
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2017

Casualty record · 6

22 October 2006Routine · role: Involved in a Marine Casualty · activity 2814705
1 August 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3554077
20 February 2010Routine · role: Involved in a Marine Casualty · activity 3701184
13 June 2021Routine · role: Involved in a Marine Casualty · activity 7253614
25 April 2022Routine · role: Involved in a Marine Casualty · activity 7443934
21 July 2022Routine · role: Involved in a Marine Casualty · activity 7513609
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.