Records from 2016 to 2025. Most recent: inspection, 4 June 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 20
4 June 2025
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8146026
3 April 2024
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7896861
20 December 2023
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7863491
11 December 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7833975
1 June 2023
Drydock Exam · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7711387
3 May 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7443046
21 March 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7415671
21 March 2022
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 7415675
11 June 2021
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7255481
6 April 2021
Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7170228
4 January 2021
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7119162
19 August 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7037584
16 September 2019
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6813246
20 May 2019
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6686474
6 June 2018
Initial Certification · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6427481
9 November 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6304073
25 April 2017
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6123224
12 July 2016
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5939044
31 May 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5892267
19 February 2016
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5830548
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 June 2025
No resolution recorded
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. An Annual Inspection was required to be completed NLT 04/08/2025. Vessel must complete an Annual Inspection with USCG prior to carrying passengers.
46CFR176.500
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2022
Resolved
The floating waterlight did not turn on. Install new battery or replace non-functioning floating waterlight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2022
Resolution: Owner purchased and installed new floating waterlight.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 May 2022
Resolved
Owner/operator must provide the latest MIS report.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2022
Resolution: Operator provided MIS report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2022
Resolved
Vessel missing life jacket donning instructions. Post life jacket donning instructions in conspicuous places.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2022
Resolution: Owner submitted photos indicating instructions have been posted.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 May 2022
Resolved
A vessel must carry either a first aid kit approved under 160.041 or a kit with equivalent contents and instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2022
Resolution: Owner submitted photo indicating deficiency has been corrected. Owner purchased new first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 May 2022
Resolved
Distress flares were not stored in a watertight container. Provide a watertight container for stowage of distress flares.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2022
Resolution: Owner purchased watertight container for stowage of distress flares.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 May 2022
Resolved
Port side fixed rails are damaged. Make proper repairs to fixed rails.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2022
Resolution: Rails repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 May 2022
Resolved
Install missing life stanchions in way of bow.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2022
Resolution: Installed life stanchions.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 May 2022
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel's last COI inspection was on January 8th, 2021. The vessel is not permitted to operate until a satisfactory annual examination has been completed.
46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2022
Resolved 12 May 2022
Resolution: Completed annual inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 March 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. The vessel is restricted to daylight operations until they provide proof all navigation lights are in working order. 46 CFR 183.420
Action required: 705 - Other - as specified
Resolved 12 May 2022
Resolution: observed satisfactory nav lights.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 March 2022
Resolved
Each vessel inspected and certificated under the provisions of this subchapter must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the terms of the certificate. The vessel is required to provide proof to this office they have the proper personnel.
46 CFR 176.100 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2022
Resolution: Verified the vessel is properly manned.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 March 2022
Resolved
A vessel must carry one floating waterlight. The vessel is restricted to daylight operations until they provide proof the life ring's waterlight is functional. 46 CFR 180.70 (d)
Action required: 705 - Other - as specified
Resolved 12 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 September 2019
Resolved
Vessel's certification date is 06June2018. Vessel has not recieved an annual inspection within three months of its anniversary date for certification. - 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2019
Resolved 19 September 2019
Resolution: Completed annual inspection, 00 defs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2018
Resolved
Conduct DAPI supervisor and crew training
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2018
Resolved 10 July 2018
Resolution: Received picture of logs recording training.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2018
Resolved
Replace corroded fire extinguisher bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2018
Resolved 11 June 2018
Resolution: Received picture of new fire extinguisher bracket.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 June 2018
Resolved
Repair cracked weld on aft stanchion.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2018
Resolved 10 July 2018
Resolution: Received picture of welded stanchion.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 6 June 2018
Resolved
Post stability letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2018
Resolved 10 July 2018
Resolution: Received picture of posted stability letter.
Navigation › Piloting/Steering › Marine Charts
Issued 12 July 2016
Resolved
JE01 Provide current charts for area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 4 August 2016
Resolution: Current charts for area of operation were placed onboard vessel.
Lifesaving › Hand Flares › Quantity
Issued 12 July 2016
Resolved
JE02 Provide sufficient hand flares for route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 4 August 2016
Resolution: Sufficient hand flares for route were onboard vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 July 2016
Resolved
JE03 Provide proper first aid kit (burn cream).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 4 August 2016
Resolution: Complete first aid kit was onboard vessel.
Lifesaving › Lifebuoys › Serviceable
Issued 12 July 2016
Resolved
JE04 Install sufficient retro reflective tape on life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 4 August 2016
Resolution: Sufficent retro reflective tape was placed on both sides of ring life buoy.
Engineering › Fuel Oil Service System › Hose
Issued 12 July 2016
Resolved
JE05 Flexible fuel hoses shall meet SAE J1942 and be properly clamped at all connections.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2016
Resolved 21 July 2016
Resolution: Received email photos of correct flex fuel hose properly installed on vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 July 2016
Resolved
JE06 Provide plans / drawings for electrical upgrades. All cables hangers must be approved metalic type.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 29 August 2016
Resolution: Received proper electrical drawing via email from [name withheld].