Records from 1985 to 2005. Most recent: inspection, 10 January 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
10 January 2005
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2272043
30 June 1995
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 882951
25 March 1992
Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 944816
30 May 1991
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 918426
19 April 1991
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 906552
15 November 1990
Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1243129
20 September 1990
Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 931532
5 September 1990
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1240539
23 August 1990
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1216929
23 August 1990
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1241526
17 August 1990
Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1228378
7 April 1990
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 920944
5 March 1990
Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 912382
21 November 1989
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 909744
15 October 1989
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1042967
8 September 1989
Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 889943
28 July 1989
Damage Survey
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 889335
28 July 1989
Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1195120
28 July 1989
Damage Survey
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1197513
14 June 1989
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1033809
9 June 1989
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1202419
4 January 1985
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 976106
Documentation
Issued 19 April 1991
Resolved
PROVIDE MARPOL ANNEX V POLLUTION PROHIBITION PLACARDS FOR INCINERATOR AREA AND CREWS MESSES.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Engineering
Issued 7 April 1990
Resolved
CONDUCT A HYDROSTATIC TEST AT 1.5 MAWP ON THE AUX. BOILER IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 7 April 1990
Resolved 7 April 1990
Engineering
Issued 7 April 1990
Resolved
PROVE PROPER OPERATION OF THE AUX. BOILER AUTOMATION CONTROLS, SAFETY VALVES AND SAFETY DEVICES.
Condition: Unknown
Due 7 April 1990
Resolved 7 April 1990
Engineering
Issued 7 April 1990
Resolved
MAKE READY FOR INSPECTION, THE FIRESIDES AND WATERSIDES ON THE AUX. BOILER.
Condition: Unknown
Due 7 April 1990
Resolved 7 April 1990
Navigation
Issued 15 October 1989
Resolved
MAKE ENGINE ORDER TELEGRAPH POWER FAILURE ALARM IN PILOTHOUSE OPERABLE.
Condition: Unknown
Due 15 October 1989
Resolved 15 October 1989
Deck/Cargo
Issued 9 June 1989
Resolved
PRIOR TO DEPARTURE FROM FIRST DISCHARGE PORT PROVIDE PROOF OF SATISFACTORY COMPLETION OF CARGO GEAR CERTIFICATION TEST REQUIREMENTS.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Engineering
Issued 9 June 1989
Resolved
PROVIDE FLANGE BLANKET COVERS FOR HIGH PRESSURE STEAM PIPING.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Accommodation/Occupational Safety
Issued 9 June 1989
Resolved
PROVE OPERATION OF PORT BOILER ROOM VENT FAN AND REMOTE SHUTDOWN FOR SAME.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Engineering
Issued 9 June 1989
Resolved
PROVE OPEERATION OF OVERSPEED SHUTDOWN FOR COFFIN FEED STEAM PUMP
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Electrical
Issued 9 June 1989
Resolved
IDENTIFY AND MAKE REPAIRS TO GROUND INDICATION ON FORWARD LIGHTING CIRCUIT.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989