Records from 1984 to 1987. Most recent: inspection, 22 October 1987.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
22 October 1987
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1015656
15 May 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1024166
16 April 1987
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1013156
4 February 1986
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1293834
26 December 1985
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 993389
12 December 1985
Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 995017
17 July 1985
Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1291973
7 February 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1284513
30 November 1984
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 976026
Documentation
Issued 16 April 1987
Resolved
1. PROVIDE CERTIFICATE OF INSPECTION (COI) AND STABILITY LETTER AND POST ABOARD VESSEL.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Lifesaving
Issued 16 April 1987
Resolved
2. PROVIDE ONE CHILD LIFE PRESERVER.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Lifesaving
Issued 16 April 1987
Resolved
3. PROVIDE TWO WATER LIGHTS- ATTACH ONE TO RING BOUY AND ONE TO LIFE FLOAT.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Fire Fighting
Issued 16 April 1987
Resolved
4. SERVICE ONE BI AND ONE BII DRY CHEMICAL PORTABLE FIRE EXTINGUISHERS THAT ARE DISCHARGED.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Construction/Loadline
Issued 16 April 1987
Resolved
5. PROVIDE HANDLE FOR THROUGH HULL VALVE ON MSD INLET.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Construction/Loadline
Issued 16 April 1987
Resolved
6. DOUBLE CLAMP HOSE ON MSD INLET VALVE.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Electrical
Issued 16 April 1987
Resolved
7. PROVIDE 3 FLASHLIGHTS.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Unknown
Issued 16 April 1987
Resolved
8. PROVIDE HAND BILGE/FIRE PUMP.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Construction/Loadline
Issued 16 April 1987
Resolved
9. CLEAN FURRED WOOD IN ENGINE COMPARTMENT AND ABOVE STARBOARD FUEL TANK.
Condition: Unknown
Due 30 June 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 4 February 1986
Resolved
REPLACE FLAME SCREEN ON STBD FUEL TANK VENT.
Condition: Unknown
Due 4 February 1986
Resolved 4 February 1986
Unknown
Issued 4 February 1986
Resolved
CONDUCT UNDERWAY OPERATIONAL TEST.
Condition: Unknown
Due 4 February 1986
Resolved 4 February 1986
Fire Fighting
Issued 4 February 1986
Resolved
PROVIDE HAND PUMP AND PROVE OPERATION.
Condition: Unknown
Due 4 February 1986
Resolved 4 February 1986
Accommodation/Occupational Safety
Issued 12 December 1985
Resolved
INSTALL LOCKING MECHANISM FOR MSD OVBD.
Condition: Unknown
Due 12 December 1985
Resolved 12 December 1985
Accommodation/Occupational Safety
Issued 12 December 1985
Resolved
PROVE OPERATION OF WYE-GATE VALVE ON MSD.
Condition: Unknown
Due 12 December 1985
Resolved 12 December 1985
Construction/Loadline
Issued 17 July 1985
Resolved
PROVIDE WRITTEN PLANS TO EFFECT REPAIRS TO DAMAGED STBD BOW
Condition: Unknown
Due 17 July 1985
Resolved 17 July 1985
Construction/Loadline
Issued 17 July 1985
Resolved
EFFECT REPAIRS AFTER PLANS APPROVED BY COAST GUARD INSPECTION OFFICE.
Condition: Unknown
Due 17 July 1985
Resolved 17 July 1985
Lifesaving
Issued 7 February 1985
Resolved
RELOCATE BUOYANT APPARATUS, LINE AND LIGHT SO AS TO BE FLOAT FREE.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Engineering
Issued 7 February 1985
Resolved
CLEAN OR REPLACE FLAME SCREENS ON BOTH FUEL TANK VENTS.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985