MAURY USCG vessel records
← All vessels

SOUTHERN MAGNOLIA

Built
1995
Last inspected
13 January 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 January 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI9712
421303
Flag
UNITED STATES
Maury page id
psix-421303

Documentation record

Registered dimensions (L × B × D)64.7 ft × 18.2 ft × 8.4 ft
Registered tonnagegross 66 / net 53
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGEORGE H PELAEZ JR · OCEAN SPRINGS, MS, UNITED STATES · built 1995
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPASS CHRISTIAN, MS
Endorsements, as the file codes themcw_un, fi, rec
DocumentationValid · issued 10 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Simplified, Gross Ton
53 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 25 inspections, each with its date, unit and type; 39 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

THE DIVERSION Passenger (Inspected) · MISLE 658827 · 23 August 2017 · activity 6249388

Inspection history · 25

13 January 2026 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8295804
12 February 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8078687
17 December 2024 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8048581
5 March 2024 Annual Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7874300
1 November 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7824891
28 March 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7646327
9 March 2023 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7648514
28 December 2022 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7613857
1 July 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7653771
17 May 2022 Type not recorded
No type recorded · USCGC RIDLEY (WPB 87328) · USCG Southeast District (CGD-SE) · Activity 7454206
11 March 2022 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7412855
23 August 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7294434
3 February 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7135062
18 December 2020 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7113798
3 February 2020 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6901945
10 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814690
20 February 2019 Internal Structural Exam · Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6629097
28 November 2018 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6588263
6 February 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6350211
23 August 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6249388
15 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6153268
22 February 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6092753
2 January 2017 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6064613
17 August 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5975361
11 January 2016 Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5794920

Deficiency record · 39

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 02 life jackets were found unservicable and destroyed in the inspectors presence.
Action required: 10 - Deficiency Rectified
Due 26 February 2026
Resolved 26 February 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 January 2026 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Battery in waterlight was found to be expired.
Action required: 10 - Deficiency Rectified
Due 26 February 2026
Resolved 26 February 2026
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 March 2024 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Vessel's floating waterlight was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2024
Resolution: provided photo evidence of new light
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 March 2024 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Life float paddles were missing name of vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 29 March 2024
Resolution: provided photo evidence of vessel name marked on life float paddles
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 5 March 2024 Resolved
Employee assistance programs must be conducted for the employer's crew members and supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Supervisor does not have a certificate of completion. Show completed course documentation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 29 March 2024
Resolution: provided photo evidence of DAPI supervisor certificate
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2023 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and suctios for each watertight compartment. Bilge suction in galley failed to operate. Check valves on bilge pipes need to be serviced. 46 CFR 182.25-5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2023
Resolved 30 March 2023
Resolution: Vessel owner sent in pictures of the new check valves installed on the bilge system and videos of the bilge suctions taking suction and operating as intended. Cleared 01 defs for bilge system operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 March 2023 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant. Forward ring life buoy wasted. 46 CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 6 April 2023
Resolution: Vessel owner sent in photos of the new lifebouy meeting CFR requirements.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit withw equivalent contents and instructions. Vessel's first aid kit did not contain valid ammonia inhalants and burn gel was missing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 6 April 2023
Resolution: Vessel owner sent in photos of the new burn cream and ammonia inhalants.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 March 2023 Resolved
A suitable marine type strainer shall be fitted in the fuel supply line in the engine compartment. No special fuel strainers other than those recommended or furnished by the engine manufacturer will be required. Drip pans fitted with flame screens may be required under fuel strainers other than those mounted on the engine. Flame screen on no.1 generator fuel filter is missing. Installation of flame screen required.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 6 April 2023
Resolution: Vessel owner sent in photos of satisfactory installation of a fuel filter flame screen.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 March 2022 Resolved
All vessels must have navigation lights in compliance with applicable sections of the International and Inland Navigation Rules. Navigation lights were not operable. Repair navigation lights. Vessel restricted to day time operations.
Action required: 705 - Other - as specified
Resolved 6 April 2022
Resolution: Rcvd objective evidence of nav lights in operation
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 31 March 2022 Resolved
Each life float must be fitted with a lifeline and pendants meeting the requirements in 46 CFR 160.010. Lifeline and pendants installed on life float were weathered and deteriorated. Replace lifeline and pendants on life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2022
Resolution: Rcvd objective evidence that lifeline and pendants replaced on life float.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 March 2022 Resolved
The use of twist-on type wire nuts is permitted as long as connections are made within an enclosure. Wires in A/C closet with wire nuts found outside junction box. Install open wires in a junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2022
Resolved 6 April 2022
Resolution: Rcvd objective evidence that wiring installed in junction box.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 March 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Numerous electrical power strips are used throughout the vessel. Remove all power strips and surge protectors. Provide plan to permanently install sufficient power charging station for radio bank, ensuring that the equipment and outlets used are suitable for voltage and current utilized.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2022
Resolution: All power strips have been removed from vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 March 2020 Resolved
Each Life Jacket must be marked with Type 1 Retroreflective Material approved in accordance with 46CFR164.018
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 March 2020
Resolution: Provided photo showing satisfactory replacement of SOLAS retroreflective tape, approved.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 March 2020 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions; vsl had expired ammonia inhalant tablets onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 12 March 2020
Resolution: Provided photo of valid ammonia tablets for first aid kit onboard, ALL SAT
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 9 April 2019 Resolved
Repair cracked hull weld (approx. 8" long, average depth of 3/16" in 1/4" plate) in midships bilge space. Submit repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2019
Resolution: Drydocked vessel. Grinded out crack and welded over.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 April 2019 Resolved
Have all crewmembers tested under proper consortium or provide proof that master will receive notification of failed drug/alcohol test from both consortiums.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
Resolution: Captain added all crewmembers to proper consortium. Letter attached.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 April 2019 Resolved
Hardwire ice machine to distribution panel. Remove ice machine plug from watertight outlet in engineroom.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
Resolution: Removed plug from outlet and hardwired ice machine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2019 Resolved
Replace hose connection to STBD generator fuel filter with appropriate flared fitting.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
Resolution: Installed proper flared fitting.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 April 2019 Resolved
Provide three distress flares for each skiff to meet recreational vessel regs. Prior to operating skiffs.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 12 April 2019
Resolution: Purchased proper amount of flares and put them in skiffs.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 12 March 2018 Resolved
No backup Light List or Coast Pilot on board to accompany digital copy. Must provide backup Light List and Coast Pilot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 21 March 2018
Resolution: Provided updated backup copy of Coast Guard Light List and Coast Pilot.
Navigation › Piloting/Steering › Marine Charts
Issued 12 March 2018 Resolved
No backup corrected charts on board to accompany digital copy. Must provide corrected backup charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 21 March 2018
Resolution: Provided updated hard copy of Charts.
Fire Fighting › Fire Bucket › Availability
Issued 12 March 2018 Resolved
Fire Bucket had hole in bottom. Must replace Fire Bucket.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 21 March 2018
Resolution: Provided new fire bucket.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 12 March 2018 Resolved
Fire extinguisher in Galley was wrong size for the space. Must replace Galley fire extinguisher with 40-B.C. size.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 21 March 2018
Resolution: Replaced galley space fire extinguisher with proper size extinguisher.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 27 April 2017 Resolved
Provide DAPI enrollment letter and alcohol testing strips IAW 46 CFR 16.113
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Provided enrollment letter.
Documentation › Logs/Records › Logbook (official)
Issued 27 April 2017 Resolved
Properly document radio checks IAW 46 CFR 184.502 and 47 CFR 80.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Provided proof of radio check logs.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 27 April 2017 Resolved
Install UL 217 compliant independent modular smoke detector near master's berthing area IAW 46 CFR 181.400 and 450.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Installed UL 217 smoke detectors.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 April 2017 Resolved
Install light switch covers in engine room IAW 46 CFR 183.340
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Installed light switch covers.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 27 April 2017 Resolved
Clearly label bilge manifold in engine room IAW 46 CFR 182.510
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Bilge manifold labeled.
Documentation › Markings/Placards › Lifejacket Placard
Issued 27 April 2017 Resolved
Provide life jacket donning instructions placrd by stowage areas IAW 46 CFR 185.516.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: PFD donning instructions posted.
Lifesaving › Lifefloat › Lifeline
Issued 27 April 2017 Resolved
Replace expired life ring buoy light IAW 46 CFR 180.70 and provide 18 ft. water light line for life float and properly secure to it, not to line IAW 46 CFR 180.715
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: New light and line installed.
Deck/Cargo › Holds/Tanks › Weathertight Door
Issued 15 March 2016 Resolved
Weather tight doors need sealed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 7 April 2016
Resolution: Both weather tight doors were resealed.
Engineering › Pressure Vessel › Relief Valve
Issued 15 March 2016 Resolved
Water heater needs 100 psi safety relief valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 7 April 2016
Resolution: !00 psi safety relief valve installed.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 15 March 2016 Resolved
Exhaust hose in laz needs tightened or replaced hose clamp.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 7 April 2016
Resolution: Replaced exhaust clamp installed and tight.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 15 March 2016 Resolved
Appliances need tied down while underway.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 7 April 2016
Resolution: Appliances installed are tied down.
Documentation › Certificates/Documents › Stability Letter
Issued 15 March 2016 Resolved
Change 2nd deck passenger count to match stability letter.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 7 April 2016
Resolution: 2nd deck marked for proper passenger count.
Navigation › Piloting/Steering › Marine Charts
Issued 15 March 2016 Resolved
Update charts, has 2011.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 7 April 2016
Resolution: Purchased new chart.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 15 March 2016 Resolved
Emergency instructions located at each operating station.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 7 April 2016
Resolution: Emergency instructions mounted at both operating stations.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 15 March 2016 Resolved
Medical kit needs updated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 7 April 2016
Resolution: Med kit was updated with new medicine.

Ownership record