Records from 1981 to 2001. Most recent: inspection, 29 May 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
29 May 2001
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 754263
23 May 2001
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 198660
25 July 1995
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1191849
16 April 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 933851
25 March 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 901408
12 March 1991
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1219587
11 February 1991
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1230514
5 February 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 933682
1 October 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 506108
24 September 1990
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1215233
6 September 1990
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 924407
3 September 1990
Deficiency Check · Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1223637
28 August 1990
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 909367
11 July 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1042794
30 June 1989
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1208568
23 February 1989
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 897451
23 February 1989
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1350067
25 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021390
6 February 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021589
6 January 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317917
28 August 1986
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1298369
25 August 1986
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1296882
17 January 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 978450
10 July 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973186
2 June 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973295
11 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1275316
23 September 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964075
9 January 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973799
Navigation
Issued 16 April 1991
Resolved
VESSEL'S RUNNING LIGHTS ARE TO BE FITTED WITH THE PROPER WATAGE LIGHT BULBS.
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Fire Fighting
Issued 6 September 1990
Resolved
PRIOR TO SAILING FROM THE PORT OF HOUSTON, DEMONSTRATE PROPER OPERATION OF THE ENGINE ROOM FORE PUMP.
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Unknown
Issued 6 September 1990
Resolved
MAKE PERMANENT REPAIR TO HOLE IN BULKHEAD BETWEEN THE MACHINE SHOP AND AFTER STEERING.
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Unknown
Issued 28 August 1990
Resolved
PROVIDE ONBOARD A COMPLETE SET OF RULES AND REGULATIONS FOR VESSEL CLASS.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
RESTENCIL FIRE STATION ON FORECASTLE AND FIRE STATION NUMBER 13
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
PROVIDE ONBOARD FOLLOWING NAV. PUBLICATIONS; SAILING DIRECTIONS, NOTICE TO MARINERS, RULES OF THE ROAD.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
PROVIDE BOTH LIFEBOATS WITH A SEA PAINTER AND AUTOMATIC CHECK BALLS. PRIOR TO SAILING FOREIGN.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
MAKE PERMANENT REPAIRS TO TANK TOP LOCATED IN FWD PUMPROOM.
Condition: Unknown
Due 28 November 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 28 August 1990
Resolved
INSTALL GLOBES AND GLOBE GUARDS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
PROVIDE ONBOARD TRAINING MANUAL FOR LIFESAVING AND FIRE-FIGHTING EQUIPMENT PRIOR TO SAILILNG FOREIGN
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
REPAIR LIGHT FOR STBD GYRO REPEATER.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
REPAIR STEAMLINE TO WINCH ON FANTAIL. PRIOR TO SAILING FOREIGN.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
REPAIR SSB RADIO AND OPERATIONALLY TEST. PRIOR TO SAILING FOREIGN.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
REPAIR, REPLACE OR REMOVE COLLISION AVOIDANCE SYSTEM FOR STBD RADAR.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
PLACE APPROPRIATE LIGHT AND WHISTLE ON ALL IMMERSION SUITS PRIOR TO SAILINGFOREIGN.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
REPLACE ALL 10 AMP FUSES WITH 2 AMP FUSES WERE APPROPRIATE, IN MAIN CONTROLPANAL.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
REPAIR DOOR TO ENGINE PAINT LOCKER. PRIOR TO SAILING.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
FIND AND REPAIR GROUNDS IN 115 VDC SYSTEM.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
REPAIR DRAIN LINE IN LOWER ENGINE ROOM BY CRANE GENERATOR.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
MAKE OPERATIONAL LOW PRESSURE EVAPORATOR, PRIOR TO SAILING.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
OPERATIONALLY TEST BOTH LIFEBOATS PRIOR TO SAILING FOREIGN
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
PROVIDE ONBOARD 3 RING BUOY LIGHTS TO BRING TOTAL TO 9.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
PROVIDE ONBOARD 2 RING BUOYS WITH APPROPRIATE LINES.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Unknown
Issued 28 August 1990
Resolved
PROVIDE NAVIGATIONAL LIGHTS WITH APPROPRIATE BULBS. PRIOR TO SAILING FOREIGN
Condition: Unknown
Due 28 November 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 6 February 1987
Resolved
COMPLETE OUTSTANDING WORK ITEMS AND/OR REQUIREMENTS UPON ACTIVATION OR 06FEB89; WORKLIST ATTACHED TO TEMP COI.
Condition: Unknown
Due 6 February 1987
Resolved 6 February 1987
Construction/Loadline
Issued 10 July 1984
Resolved
#5 PORT WING TANK IN AFTER BAY GOUGE OUT AND REWELD FRACTURES IN FRAMES 55 AND 56
Condition: Unknown
Due 10 July 1984
Resolved 10 July 1984
Construction/Loadline
Issued 10 July 1984
Resolved
#5 STBD WING TANK-GOUGE OUT AND REWELD TWO(2) FRACTURES IN DEEP WELL FRAMES
Condition: Unknown
Due 10 July 1984
Resolved 10 July 1984
Construction/Loadline
Issued 10 July 1984
Resolved
#6 STBD WING TANK GOUGE OUT AND REWELD TWO(2) FRACTURES IN DEEP WELL FRAMES
Condition: Unknown
Due 10 July 1984
Resolved 10 July 1984
Construction/Loadline
Issued 10 July 1984
Resolved
#5 PORT WING TANK-WELD PARTITION BULK. THAT IS INBOARD ADJACENT TO CEMENT BALLEST BULK NOT WELDED FOR 6' IN WELD AREA ABOVE THE LIGHTNING HOLE
Condition: Unknown
Due 10 July 1984
Resolved 10 July 1984
Construction/Loadline
Issued 10 July 1984
Resolved
PORT WING TANK-CROP TO GOOD METAL AND REPLACE WARPED SIDE SHELL LONGS #11 AND #12 LOCATED IN 2ND BAY
Condition: Unknown
Due 10 July 1984
Resolved 10 July 1984
Construction/Loadline
Issued 10 July 1984
Resolved
#5 PORT WING TANK-CROP TO GOOD METAL AND REPLACE WASTED SIDE SHELL LONGS #11 AND #10 LOCATED IN WAY OF THE SPLASH BULKHEAD IN THE FWD BAY
Condition: Unknown
Due 10 July 1984
Resolved 10 July 1984