Records from 1985 to 1994. Most recent: inspection, 5 August 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
5 August 1994
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 871477
2 December 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1159519
14 June 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1148703
14 June 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1157887
21 December 1992
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1135447
12 August 1992
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1245241
6 July 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1268529
7 June 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1240185
4 June 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1231665
15 October 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1228086
13 July 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 901429
13 June 1990
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1228698
15 March 1990
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 918582
1 August 1989
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1193914
15 June 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1343210
16 November 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 893052
24 May 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1352712
5 November 1987
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1021189
11 August 1987
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1029729
13 July 1987
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1017849
22 May 1986
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1297508
4 April 1986
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1305125
28 February 1986
Credit Drydock · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1306191
28 May 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1289616
Engineering
Issued 6 July 1992
Resolved
DOUBLE CLAMP EXHAUST COOLING HOSE ON MAIN PROPULSION ENGINE.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Engineering
Issued 6 July 1992
Resolved
INSTALL FUEL VENT SCREENS FOR BOTH FUEL TANK VENT LINES.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Documentation
Issued 6 July 1992
Resolved
PROVIDE CURRENT FCC STATION LICENSE.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Navigation
Issued 6 July 1992
Resolved
PROVIDE CURRENT CHARTS AND PUBLICATIONS IN ACCORDANCE WITH MSO/GROUP LA-LB [name withheld] DATED 1 JUNE 1992.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Construction/Loadline
Issued 6 July 1992
Resolved
INSTALL A FIXED BILGE SYSTEM WITH A FIXED PUMP.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Lifesaving
Issued 6 July 1992
Resolved
POST EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Documentation
Issued 6 July 1992
Resolved
PROVIDE CURRENT STICKER FOR CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Construction/Loadline
Issued 4 June 1991
Resolved
REMOVE AND TREAT SURFACE ROT IN THE ENGINE COMPARTMENT.
Condition: Unknown
Due 4 June 1991
Resolved 4 June 1991
Unknown
Issued 4 June 1991
Resolved
REMOVE ALL WATER FROM THE BILGES.
Condition: Unknown
Due 4 June 1991
Resolved 4 June 1991
Lifesaving
Issued 13 June 1990
Resolved
CLEAN ALL OIL-SOAKED PFD'S.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Navigation
Issued 13 June 1990
Resolved
PROVIDE COPY OF RULES OF THE ROAD, NAVIGATIONAL CHARTS, AND NAUTICAL PUBLICATIONS IAW 46 CFR 185.20-35.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Engineering
Issued 13 June 1990
Resolved
REPLACE BILGE HOSE WITH COAST GUARD ACCEPTABLE HOSE AND SECURE PUMP.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Engineering
Issued 13 June 1990
Resolved
REPLACE PORT AND STARBOARD FUEL VENT FLAME SCREENS WITH 30 X 30 MESH.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Electrical
Issued 13 June 1990
Resolved
REPAIR LIGHT IN HEAD.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Fire Fighting
Issued 13 June 1990
Resolved
SERVICE 1 B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Navigation
Issued 13 June 1990
Resolved
INSTALL AND PROVE PROPER OPERATION OF 360-DEGREE ALL-AROUND WHITE ANCHOR LIGHT.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Navigation
Issued 13 June 1990
Resolved
REPOSITION MASTHEAD LIGHT FOR BETTER VERTICAL AND HORIZONTAL VISIBILITY.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Accommodation/Occupational Safety
Issued 13 June 1990
Resolved
REPLACE INNER BOW RAILING, STARBOARD SIDE.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Documentation
Issued 15 March 1990
Resolved
RENEW FCC STATION LICENSE AND RADIOTELEPHONY CERTIFICATES.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Construction/Loadline
Issued 15 March 1990
Resolved
PLUG HOLES IN OUTER LAYER OF HULL PLANKING ON STARBOARD SIDE, 12' AFT OF BOW AND 1' BELOW WATERLINE.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Documentation
Issued 15 March 1990
Resolved
RENEW DOCUMENTATION CERTIFICATE.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Construction/Loadline
Issued 15 March 1990
Resolved
MAKE BOTH MAIN DECK HATCHES WATERTIGHT.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Construction/Loadline
Issued 15 March 1990
Resolved
CLEAN AND TREAT DRY ROT ON OVERHEAD TRANSVERSE FRAMES ON PORT AND STARBOARDSIDES OF TRANSMISSION.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Lifesaving
Issued 15 June 1989
Resolved
PROVIDE BATTERY FOR RING LIFE BUOY WATERLIGHT. PROVIDE PRIOR TO OPERATING.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Electrical
Issued 15 June 1989
Resolved
PROPERLY MAKE BRIDGE WIRING JOINTS AND SPLICES IAW 46 CFR 183.05-50(B).
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Lifesaving
Issued 15 June 1989
Resolved
PROVIDE FLOAT-FREE LINK FOR LIFE FLOAT. VESSEL LIMITED TO OPERATIONS IN LESS THAN 100 FEET UNTIL PROVIDED IAW 46 CFR 180.20-1(A)(4).
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Documentation
Issued 15 June 1989
Resolved
UPDATE VESSEL DOCUMENT TO REFLECT NEW ADDRESS.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Electrical
Issued 15 June 1989
Resolved
PROVIDE BATTERY BOXES IAW 46 CFR 183.05-20.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Lifesaving
Issued 15 June 1989
Resolved
PROVIDE RETROREFLECTIVE TAPE FOR 3 ADULT PFD'S. VESSEL OPERATIONS LIMITED TO 19 TOTAL PASSENGERS AND CREW UNTIL COMPLETED.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Documentation
Issued 15 June 1989
Resolved
OBTAIN AND POST STABILITY LETTER.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Electrical
Issued 24 May 1988
Resolved
MAKE REPAIRS TO WIRING AT ENGINE STARTER SWITCH.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Electrical
Issued 24 May 1988
Resolved
REMOVE OR DEAD-END IN A JUNCTION BOX ELECTRICAL CABLES FORWARD PORT SIDE IN E/R.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Lifesaving
Issued 24 May 1988
Resolved
ADJUST RING BUOY STOWAGE SO THAT BUOY MAY BE CAST LOOSE IAW 46 CFR 180.30-10(A).
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Lifesaving
Issued 24 May 1988
Resolved
REMOUNT BUOYANT APPATATUS WATERLIGHT SO THAT IT FLOATS FREE.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Lifesaving
Issued 24 May 1988
Resolved
INSTALL FLOAT-FREE LINK ON BUOYANT APPARATUS IAW 46 CFR 180.20-(A).
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Lifesaving
Issued 24 May 1988
Resolved
PROVIDE 2 ADULT PFD'S.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Fire Fighting
Issued 24 May 1988
Resolved
INSTALL HOSE ON SUCTION SIDE OF HAND BILGE/FIRE PUMP IAW 46 CFR 182.25- 10(E).
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Deck/Cargo
Issued 24 May 1988
Resolved
INSTALL DOUBLE HOSE CLAMPS ON BAIT TANK FILL PEDRO.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Construction/Loadline
Issued 24 May 1988
Resolved
TREAT DRYROT IN E/R OVERHEAD AFT OF HATCH.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Construction/Loadline
Issued 13 July 1987
Resolved
PROVIDE MEANS TO CLOSE EXHAUST VALVE IN STERN LAZARETTE.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Electrical
Issued 13 July 1987
Resolved
REMOVE/REPAIR EXPOSED WIRING IN REST ROOM.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Construction/Loadline
Issued 13 July 1987
Resolved
MAKE VENT OPENING WATERTIGHT IN REST ROOM.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Lifesaving
Issued 13 July 1987
Resolved
PROVIDE 1 ORANGE & 2 RED DISTRESS FLARES.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Lifesaving
Issued 13 July 1987
Resolved
STENCIL LIFE PRESERVER STOWAGE.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Fire Fighting
Issued 13 July 1987
Resolved
PROVIDE SERVICING CERTIFICATE FOR 3 PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Construction/Loadline
Issued 4 April 1986
Resolved
PROVIDE HOSES FOR HAND BILGE PUMP.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Construction/Loadline
Issued 4 April 1986
Resolved
PROVIDE CAPTIVE CHAINS, DOGGING DEVICES, AND MAKE WATERTIGHT, THE THREE DECK HATCHES 1)LOCATED JUST FORWARD OF MAIN ENGINE, 2) OCATED JUST FORWARD OF BAIT TANK, AND 3) TO AFT LAZARETTE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986
Resolved
MARK LOCATION OF LIFEJACKET STOWAGE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986
Resolved
PROVIDE SEPERATE LOCATION FOR CHILD'S LIFEJACKETS.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986
Resolved
REMARK NUMBER PERSONS CAPACITY ON BUOYANT APPARATUS.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Construction/Loadline
Issued 4 April 1986
Resolved
DOUBLE CLMAP ALL RUBBER HOSES TO OVERBOARDS.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Documentation
Issued 4 April 1986
Resolved
PROVIDE VALID FCC RADIO STATION LICENSE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986