Records from 2016 to 2017. Most recent: inspection, 21 January 2017.
Engineering › Diesel Engine (propulsion-direct drive) › Nozzle, Injection (fuel injection)
Issued 8 November 2016
Resolved
1410 Propulsion Main Engine. - The machinery and other pressure vessel, accoiated piping asystems and fittings shall be of adequte design for the service they are intended. PSCO's noted a fuel leak on the high pressure fuel pump on the #2MDE. SOLAS 74a (97)II-1/33.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2016
Resolved 9 November 2016
Resolution: 09NOV16: Received, reviewed and accepted class report from Lloyds stating the outstanding deficiency have been rectified. The class report stated: Ships crew replaced "O' ring on high pressure fuel pump, all test sat.
Engineering › Steam System (main) › Piping
Issued 8 November 2016
Resolved
0899 - Other Accid. prevent.Every steam pipe and every fitting connected there to through which steam may pass shall be so designed, constructed and installed as to withstand the max working stresses that it may be subject to. PSCO's noted a large steam leak on the steam feed line to the hotel water heater. SOLAS 74a(97)II-1/33.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 November 2016
Resolved 9 November 2016
Resolution: 09NOV16: Received, reviewed and accepted class report from Lloyds stating the outstanding deficiency has been rectified. Crew replaced gasket on coupling of steam line with no lea
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 November 2016
Resolved
0745-Fire-Dampers remote control, etc. Fire doors in main vertical zone and stairways enclosures shall be of the self closing type with no more than 40 seconds and no less than 5 Seconds. PSCO's noted numerious Fire Screen Doors that did not close withing this time requirement. SOLAS 74a II-2/30
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 21 January 2017
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
Lifesaving › Lifebuoys › Size
Issued 8 November 2016
Resolved
0650 - Lifebuoys. Every lifebuoy shall: if it is intended to operate the quick release arrangement provided for the self activated somke signal and light, have a mass suffecient to operate quick release arrangment of not less than 4kg. PSCO's observed that both bridge wing lifebouys were 2.5kg. SOLAS 74a (97)III/31.1.7
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 8 November 2016
Resolution: The crew replaced the lifebuoys with the correct size while the Marine Inspectors were still onboard the vessel.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 4 February 2016
Resolved
Main and auxiliary steering gear power units shall have, in the event of a power failure to any one of the steering gear power units, an audible and visual alarm on the navigation bridge. PSCO noted that there is no audible alarm on the navigation bridge. Provide clarification from class. SOLAS 74am; II-1/29.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 15 March 2016
Resolution: Received class report from LLoyd's Register of shipping noting that the condition of class related to the audible alarm has been deleted.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 4 February 2016
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination up to 3.5 degrees. PSCO found numerous doors throughout the ship that did not latch. SOLAS 74am: II-2/30
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 19 February 2016
Resolution: Received Bermuda flag letter attesting to the proper operation of all fire screen doors.