Inspection history · 68
10 March 2026
Vessel Attendance · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8324159
25 March 2025
Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8100340
22 February 2024
Annual Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7868996
6 June 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7704328
20 May 2022
Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7455361
16 July 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6741578
7 May 2019
COI Inspection · Drydock Exam · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6672800
9 October 2018
Administrative Inspection · MARPOL Annex VI Survey · Annual Survey · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6558316
23 August 2017
Administrative Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6249239
11 July 2017
Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6205314
22 March 2017
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6109607
20 January 2017
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6077026
13 January 2016
Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5796433
16 December 2014
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5043899
12 December 2014
Welding Related Inspections Qualification Testing · Administrative Inspection · Plan Review (Other than "T") · Internal Structural Exam · Examination of Repairs · Hull Examination · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5039975
27 October 2014
Administrative Inspection · COI Inspection · MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5013703
24 January 2014
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4787754
17 December 2012
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4501485
15 May 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4312014
31 January 2012
Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4236746
18 January 2012
Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4226136
2 December 2010
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3902990
7 January 2010
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3660535
31 March 2009
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3438652
14 October 2008
Deadweight Survey · Inclining Experiment
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3346156
17 July 2008
Plan Review (Other than "T") · Deadweight Survey · Uninspected Other
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3296909
12 June 2008
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3252590
30 October 2007
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3090612
18 September 2007
MARPOL Annex II Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3060753
6 March 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2880613
15 August 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2748757
30 May 2006
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2658811
10 April 2006
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2621537
11 January 2005
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2272698
6 January 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2270060
16 December 2004
Internal Structural Exam · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2246952
23 September 2003
Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1880307
7 June 2002
Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1631071
6 May 2002
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1613509
24 September 2001
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1366607
16 November 2000
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1412204
2 November 1999
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397289
28 July 1999
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1416924
16 December 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1393058
17 October 1997
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1416585
11 April 1997
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385966
4 December 1996
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 876139
24 October 1996
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1448820
1 May 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1083657
3 April 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1077711
23 October 1995
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1079331
25 September 1994
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 861085
12 August 1994
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1455186
18 August 1993
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1440731
5 August 1993
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1405413
21 September 1992
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1439337
4 May 1992
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 947691
7 November 1991
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 939755
25 September 1990
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 899910
25 September 1989
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1305609
6 February 1989
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1210599
4 November 1988
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 891564
1 November 1988
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1202038
12 November 1987
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1022297
20 October 1986
Credit Drydock · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1321331
10 October 1985
Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 991628
3 July 1985
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1295421
19 April 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1290891
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 March 2026
Resolved
The installation of the lighting systems shall be in accordance with the requirements of Subchapter J. Emergency lighting was found insufficient along egress route in lower storage room. Add additional emergency lighting in this space to the satisfaction of the marine inspector.
46 CFR 96.05-1
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2026
Resolved 1 April 2026
Resolution: Vessel added 01 emergency light in lower storage room.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 24 March 2026
Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable Type II or III device that is certified. Secure leak located at the three-way joint on the piping which extends overboard.
33 CFR 159.7
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2026
Resolved 1 April 2026
Resolution: Secured the leak.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 24 March 2026
Resolved
Every ship above 400 Gross Tonnage shall be provided with an Oil Record Book Part 1. The Oil Record Book shall be completed when bunkering of fuel. Vessel had an oil record book however the book was blank and no entries were made reflecting bunkering. Educated rep on properly filling out the book and corrected def on the spot.
MARPOL 1/17.2
Action required: 10 - Deficiency Rectified
Resolved 24 March 2026
Resolution: Educated rep on properly filling out the book and corrected def on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 March 2025
Resolved
Inflatable life rafts shall be stowed in such a manner that they will float free in the event of the vessel sinking. The life raft arrangement at the time of attendance was not float free.
46 CFR 94.15-10(c)(4)
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2025
Resolved 11 April 2025
Resolution: Attending MI’s provided education, and assisted POC in correctly hooking up the raft so that it was in a float-free arrangement.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 25 March 2025
Resolved
The installation of the lighting systems shall be in accordance with the requirements of Subchapter J. Lighting throughout all spaces on the barge was found without bulbs or extinguished to include emergency lighting.
46 CFR 96.05-1
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2025
Resolved 29 April 2025
Resolution: Extinguished lighting to include e-lighting was verified renewed and operational, and an e-light to cover the area where the inflatable life raft would be launched was properly installed.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 25 March 2025
Resolved
Nothing in this subpart shall limit the inspector from making inspections deemed necessary to assure the safety and seaworthiness of the vessel. The following within the tool room must be cropped/renewed and be inspected by a Marine Inspector to include NDT:
- 02 holes on the overhead.
-The wasted section of the fixed drainpipe behind the washing machine.
-Hole in the deck near the washing machine allowing for water from the wasted drainpipe to flow into the space below (storage space).
46 CFR 91.25-50
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2025
Resolved 29 April 2025
Resolution: 02 holes on the overhead in the tool room and the hole in the deck near the washing machine were inserted and found satisfactory. The water piping found leaking during reattendance and dripping into the storage room below was repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2025
Resolved
Each ring buoy of an approved type may be used if it is in serviceable condition. Replace buoy lifelines that are dry rotting, and re-stencil those without/ with faded vessel name & hailing port.
46 CFR 94.43-5(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2025
Resolved 11 April 2025
Resolution: Ring buoy lifelines that had been found dry-rotting were replaced, and buoys called out re-stenciled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2025
Resolved
An electric apparatus must be designed, constructed, and installed to prevent any person from accidentally contacting energized parts. A 220V panel within the upper machinery space was missing a blank and was displaying a ground fault. A breaker panel within the tool room was missing hardware to the front panel.
46 CFR 111.05-3(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2025
Resolved 11 April 2025
Resolution: The 220V panel within the upper machinery space had missing blanks renewed and was no longer displaying a ground fault. The company electrician attended and rectified. The breaker panel in the tool room had missing hardware renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2025
Resolved
Approved portable fire extinguishers should be installed to the satisfaction of the OCMI. Two extinguishers were found with low charge (tool room & upper machinery space) and require recharging. The portable extinguisher bracket was mounted within the lower machinery space with no extinguishers.
46 CFR 95.50-10
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2025
Resolved 11 April 2025
Resolution: The tool room and upper machinery space portable extinguishers were recharged, and the portable extinguisher missing from the lower machinery space was in place.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 25 March 2025
Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable Type II or III device that is certified. Provide documentation/proof that the onboard MSD is a certified Type II device or secure the device in a manner which prevents discharge of sewage within 03 nautical miles from shore.
33 CFR 159.7
Action required: 705 - Other - as specified
Due 25 March 2025
Resolved 29 April 2025
Resolution: Type approval documentation that was providedm and a third-party plumbing company attended and replaced what was found to be 02 inoperable 3-way valves on piping to the unit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 March 2025
Resolved
For transfer of oil to, from, or within each vessel with a capacity of 250 barrels or more each metallic hose, must not leak under static liquid pressure of at least 1.5 times the maximum allowable working pressure, and be tested annually. Last documentation showed hydro test in 2022. Provide proof of recent annual test for 02 hoses on reels used to supply day tanks.
33 CFR 156.100
33 CFR 156.170
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2025
Resolved 11 April 2025
Resolution: Both fuel hoses used to fill day tanks were renewed and have valid hydrostatic tests. Documentation within deficiency documents tab.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2025
Resolved
Each switchboard must have a drip shield and front non-conductive handrails. Main switchboard did not have a drip shield or non-conducting handrails.
46 CFR 111.30-9
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2025
Resolved 29 April 2025
Resolution: A drip shield was put into place over the main switchboard, and a non conductive handrail added.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 11 March 2024
Resolved
Maintain a ballast water management (BWM) plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's BWM strategy and comply with the requirements of this subpart. Vessel lacks BWM plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 March 2026
Resolution: Ballast water management plan onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 June 2022
Resolved
Pressure vessel relief valves hae not been certified. Install relief valves with certifications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 13 June 2022
Resolution: New relief valves were installed with certificates.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 7 June 2022
Resolved
Oil record book was not onboard or being used. Oil record book must be onboard and used IAW 33 CFR 151.25
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 8 June 2022
Resolution: Vessel was issued an oil record book and their fueling evolution was properly logged.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 June 2022
Resolved
Life raft has not had its annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 13 June 2022
Resolution: Life raft annual inspection was completed.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 7 June 2022
Resolved
Immersion suits were dry rotted. If onboard, immersion suits must be in servicable condition.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 7 June 2022
Resolution: Immersion suits were destroyed and removed from the vessel. Vessel is currently working below 32 degrees and is not currently required to have them onboard IAW 46 CFR 199.273.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022
Resolved
Wires in the workshop overhead must be secured to wire runs.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 29 June 2022
Resolution: Wires were properly secured in wire run
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022
Resolved
Non conductive matting must be installed under the generator switchboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 8 June 2022
Resolution: Non conducting deck covering was properly installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2019
Resolved
Multiple fire extinguishers out of range per guauge and not tested on last inspection. Vessel to have extinguishers examined and replaced if needed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2019
Resolved 23 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 May 2019
Resolved
Lagging on spud engine missing or oil soaked. Verify oil leak is secured and lagging is replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2019
Resolved 23 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 16 May 2019
Resolved
Oil filled buckets through the barge. General cleanliness issued. Remove fire hazards from barge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2019
Resolved 23 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 16 May 2019
Resolved
Aft bilge full of water. Clean bilge to verify no flooding.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 16 May 2019
Resolved 16 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2019
Resolved
Outlets and junction boxes not secured properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 23 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2019
Resolved
Ground fault detection not installed on distribution panels.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 23 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2019
Resolved
Emergency lighting not labeled correctly.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 23 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2019
Resolved
Cable runs not secured properly. Plastic wire ties holding cable runs to overhead.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 23 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 October 2018
Resolved
Ensure that all MDEs have approved fuel filters.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2018
Resolved 11 October 2018
Resolution: All fuel filters have been changed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 October 2018
Resolved
Ensure port side generator cable is installed with the proper bend and sheathing protection (chaffing gear) for the cable.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2018
Resolved 11 October 2018
Resolution: The generator cable has been shifted and chaffing gear was added.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2018
Resolved
Ensure that the lighting fixture on exterior STBD side is properly installed to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2018
Resolved 11 October 2018
Resolution: The lighting fixture was completely replaced, including the cable.
Documentation › Logs/Records › Oil Record Book
Issued 13 January 2016
Resolved
Provide the vessel with an Oil Record Book, Part 1, and log any operations listed in MARPOL 73/78, Annex I, Reg. 17.2.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 10 February 2016
Resolution: Provided vessel with an ORB and gave training to crewmembers on proper entries in the logbook.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 13 January 2016
Resolved
Provide fuel tank vent with appropriate containment or portable container of at least 5 U.S. gallons during transfer operations.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 2 February 2016
Resolution: The vent is not required to have containment since it is not for a fuel tank but for a potable water tank.
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 13 January 2016
Resolved
Remove cooking facilities on board the barge or receive new load line assignment in compliance with Chapter III, Load Lines Convention 1969.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Resolution: Vessel personnel removed cooking appliances onboard the barge.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 13 January 2016
Resolved
Conduct hydrostatic test on transfer piping for the 2C fuel tank.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 5 June 2017
Resolution: MI's witnessed the hydrostatic test of the fuel oil transfer pipe (1.50x MAWP, 225PSI on 3" line). No leaks, test sat
Operations/Management › Pollution › Approved Method for Annex VI Compliance
Issued 10 November 2014
Resolved
Each ship of 400 GT and greater must have a Ship Energy Efficiency Management Plan (SEEMP), as per MARPOL Annex VI/22. Vessel does not have a SEEMP. Provide an SEEMP, prior to sailing on an international voyage.
Action required: 705 - Other - as specified
Due 10 December 2014
Resolved 16 December 2014
Resolution: Vessel provided SEEMP that fully meets regulations.
Engineering › Generator (propulsion-electric) › Cable
Issued 27 October 2014
Resolved
Rotating machinery on back side of generator does not have a guard, creating a potentially hazardous situation. Provide proper guard over rotating machinery on generator in accordance with 46 CFR 58.01-20.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 December 2014
Resolved 16 December 2014
Resolution: Guard was fabricated and installed to cover rotating machinery on the generator.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 October 2014
Resolved
Retroreflective material on all PFDs is no longer acceptable. Provide lifejackets with Type I retroreflective material prior to carrying crewmembers onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2014
Resolved 16 December 2014
Resolution: All retroreflective tape on existing PFDs was replaced. Vsl rep also completed a changeout of all lights on PFDs.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 10 October 2014
Resolved
Buoyant Apparatuses are not in correct locations onboard vsl. Retroreflective material has been stenciled on reducing its total surface area. Provide lifebuoy on each end of vsl in accordance with 46 CFR 199.640 (i) (2). Retroreflective tape shall not have markings over it.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2014
Resolved 16 December 2014
Resolution: Retroreflective tape was corrected. Vsl rep ensured appropriate buoyant apparatus were in the correct locations onboard the vsl.
Electrical › Electric Generation Source (service) › Generator
Issued 24 January 2014
Resolved
Barge generator not operating. Parts on order for repair.
Due 24 February 2014
Resolved 24 June 2014
Resolution: Parts installed and generator operating properly.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 15 May 2012
Resolved
Internal inspection appeared to show some pitting and a lot of rust build up on the bottom of the receiver. Hydro or replacement is required.
Action required: 705 - Other - as specified
Resolved 16 May 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 May 2012
Resolved
Batteries missing due to installation the same morning of the inspection.
Due 23 May 2012
Resolved 18 May 2012
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 30 May 2006
Resolved
Permanently mount 2 aft Dry Chemical fire extinguishers.
Due 30 June 2006
Resolved 27 June 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 30 May 2006
Resolved
Permanently mount 1 fwd dry chemical fire extinguisher.
Due 30 June 2006
Resolved 27 June 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 May 2006
Resolved
Replace batteries in all ring buoy lights with approved type.
Due 30 June 2006
Resolved 27 June 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 30 May 2006
Resolved
Replace or service fire extinguisher next to main generator in crane house.
Due 30 May 2006
Resolved 30 May 2006
Engineering › Generator (propulsion/auxiliary-electric) › Junction Box
Issued 30 May 2006
Resolved
Properly mount wires on top of Generator in a junction box.
Due 30 June 2006
Resolved 27 June 2006
Engineering › Pressure Vessel › Pressure Gauge
Issued 30 May 2006
Resolved
Install new gauge with proper range of pressure.
Due 30 June 2006
Resolved 27 June 2006
Engineering › Pressure Vessel › Relief Valve
Issued 30 May 2006
Resolved
Install new relief valve with proper markings for MAWP relief settings
Due 30 June 2006
Resolved 27 June 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2005
Resolved
Install globes and guards to incandescent lighting fixtures as indicated by attending marine inspector.
Action required: 705 - Other - as specified
Due 5 February 2005
Resolved 30 June 2006
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 11 January 2005
Resolved
Install exhaust lagging on exposed exhaust piping for port winch diesel powered prime mover.
Due 5 February 2005
Resolved 30 June 2006
Operations/Management › Drills/Instruction › Fire
Issued 11 January 2005
Resolved
Properly label fuel oil shut-off valves at access hatches and at shut-off valves.
Action required: 705 - Other - as specified
Due 11 February 2005
Resolved 30 June 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 16 December 2004
Resolved
Repair indicated crack to forward center longitudinal frame located in number 1 Starboard void.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2005
Construction/Loadline › Hull › Bracket
Issued 16 December 2004
Resolved
Repair trip bracket that has cracked at aft upper outboard corner of number 1 port void as indicated and marked by attending inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2005
Construction/Loadline › Hull › Longitudinal Frame
Issued 16 December 2004
Resolved
Provide gaging report for all frames and midbody gaging performed for ABS Loadline Survey. Repair of wasted frames is contingent on requested scantling review to be performed by naval architect and approved by MSC. Credit drydock will only be given after issuance of Loadline certificate by the American Bureau of Shipping (ABS).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2006
Engineering › Fuel Oil Storage/Transfer System
Issued 23 September 2003
Resolved
Replace flame screen for fuel/oil day tank. LEGACY COMPONENT DESC: Ventilation
Due 24 October 2003
Resolved 31 October 2003
Electrical › Electrical Distribution System (service)
Issued 23 September 2003
Resolved
Plug holes in main hoist room 440V panels (3) and spud winch gear panel. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Due 24 October 2003
Resolved 31 October 2003
Electrical › Electric Supply System (service)
Issued 23 September 2003
Resolved
Remove water from battery boxes. LEGACY COMPONENT DESC: Battery Installation
Due 24 October 2003
Resolved 31 October 2003
Electrical › Electric Supply System (service)
Issued 23 September 2003
Resolved
Replace welding cable at batteries with marine grade battery cable. LEGACY COMPONENT DESC: Cable
Due 24 October 2003
Resolved 31 October 2003
Electrical › Lighting (service)
Issued 23 September 2003
Resolved
Plug/disconnect empty light sockets in lower storage room in way of wooden platform. LEGACY COMPONENT DESC: Lighting Fixture
Due 24 October 2003
Resolved 31 October 2003
Lifesaving › Lifebuoys
Issued 23 September 2003
Resolved
Remove waterlight or line on all liferings so that both are not on the same lifering. Required one lifering with line, one with light.
Due 24 October 2003
Resolved 31 October 2003
Lifesaving › Lifebuoys
Issued 23 September 2003
Resolved
Add retroreflective tape and vessel name to life ring at bow and at port quarter along forward port side of the house.
Due 24 October 2003
Resolved 31 October 2003
Electrical › Electrical Distribution System (service)
Issued 23 September 2003
Resolved
Add cover to deck service crane junction box. LEGACY COMPONENT DESC: Junction Box
Due 24 October 2003
Resolved 31 October 2003
Electrical › Lighting (service)
Issued 23 September 2003
Resolved
Replace covers and bulbs to empty light sockets in way of anchor winch area. LEGACY COMPONENT DESC: Lighting Fixture
Due 24 October 2003
Resolved 31 October 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 23 September 2003
Resolved
Provide mechanical protection for spud winch engine day tank sight glasses.
Due 24 October 2003
Resolved 31 October 2003
Electrical › Electric Supply System (service)
Issued 23 September 2003
Resolved
Hardwire battery charger for 12V systems in crane control room. LEGACY COMPONENT DESC: Battery Charger
Due 24 October 2003
Resolved 31 October 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 September 2003
Resolved
Remove expired aspirin from medical kit.
Due 23 September 2003
Resolved 23 September 2003
Accommodation/Occupational Safety
Issued 24 October 1996
Resolved
PROPERLY INSTALL MSD FOR THE ACCOMENDATION SPACE. PRIOR TO CORRECTING THIS ITEM THE HEAD MUST BE SECURED WHILE THE BARGE IS WITHIN 3 NM OF LAND.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Electrical
Issued 24 October 1996
Resolved
PERMENATELY INSTALL WIRING FROM BATTERY CHARGERS TO BATTERIES.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Electrical
Issued 24 October 1996
Resolved
PROPERLY LINE ALL BATTERY BOXES WITH CORROSION RESISTANT MATERIAL.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Electrical
Issued 24 October 1996
Resolved
PROPERLY COVER THE SWITCHBOARD FOR THE NAVIGATION LIGHTS IN THE HOIST ROOM.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Electrical
Issued 24 October 1996
Resolved
REMOVE ALL DEADEND WIRES ON THE BARGE ON THE BARGE.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Deck/Cargo
Issued 24 October 1996
Resolved
PLACE PROTECTIVE COVER ON THE FAN FOR THE HYDRAULIC PUMP ON THE PORT SIDE.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Deck/Cargo
Issued 24 October 1996
Resolved
PLACE PROTECTIVE COVER ON THE DC GENERATOR EXCITER MOTOR IN THE HOIST ROOM.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Lifesaving
Issued 24 October 1996
Resolved
REINSTALL WELDING BOTTLES A SAFE DISTANCE FROM THE PAINT LOCKER AND PROPERLY ELEVATE AND SECURE THE BOTTLES.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Lifesaving
Issued 24 October 1996
Resolved
PROVE ANNUAL SERVICING OF INFLATABLE LIFERAFT AND PROPER INSTALLATION ON THE BARGE.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Electrical
Issued 24 October 1996
Resolved
REPLACE ALL PLASTIC ZIP TIE SUPPORTS FOR ELECTRICAL WIRING WITH STEEL METALBANDS.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Documentation
Issued 23 October 1995
Resolved
PROVIDE AN APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN IN ACCORDANCE WITH REGULATION 26 OF THE INTERNATIONAL CONVENTION FOR THE PREVENTION OF POLLUTION FROM SHIPS.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Construction/Loadline
Issued 25 September 1994
Resolved
PROVIDE GAUGING REPORT FOR VESSELS HULL/DECK PLATING.
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Lifesaving
Issued 5 August 1993
Resolved
REPLACE MISSING CG-APPROVED LIGHTS FOR LIFEJACKETS (3) AND SURVIVAL/IMMERSION SUITS (6).
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Electrical
Issued 5 August 1993
Resolved
INSTALL A BLANK IN THE OPEN CIRCUIT BREAKER SPACE FOR THE ELECTRICAL PANEL BOX LOCATED NEXT TO THE CRANE'S PRIME MOVER.
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Accommodation/Occupational Safety
Issued 5 August 1993
Resolved
PROVIDE A PRESSURE GAUGE FOR THE AIR RECEIVER (SERIAL NO. 15803) LOCATED UNDER THE CRANE HOUSE.
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Accommodation/Occupational Safety
Issued 5 August 1993
Resolved
REPLACE MISSING HANDRAIL FOR LADDER IN WAY OF CRANE GANTRY.
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Electrical
Issued 1 November 1988
Resolved
COMPLETE REQUIRED TESTS ON SERVICE GENERATORS, OVER SPEEDS, LO LUBE OIL SHUT DOWNS AND ALL REQUIRED ALARMS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988