TEXAS TEASE

TEXAS TEASE is a 1995 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 1995, most recently in March 2026, along with 50 deficiencies.

Records from 1995 to 2026. Most recent: inspection, 26 March 2026.

Built
1995
Last inspected
26 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ6473
421560
Flag
UNITED STATES
368339920
Maury page id
psix-421560

Inspections, by type

…with no type recorded1
Years with a record 30 calendar years (1995–2026)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.0 ft × 19.0 ft × 8.0 ft
Registered tonnagegross 66 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNAVIGATOR BOATS · ELMORE, AL, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCORPUS CHRISTI, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Simplified, Gross Ton
52 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP2833MMSI 368339920 · active · compulsorily equipped · granted 31 October 2023, expires 31 October 2033
WCZ6473MMSI 367075140 · expired · compulsorily equipped · granted 29 January 2010, cancelled 4 April 2020 · licensed under a name not among this hull’s recorded names (not shown)
WCY8184MMSI not assigned · expired · compulsorily equipped · granted 23 December 1998, cancelled 28 February 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 46

26 March 2026 Vessel Attendance · Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8302383
12 December 2025 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8282733
18 July 2025 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8188796
25 March 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7884883
27 February 2024 In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7877640
16 February 2024 Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7866721
25 October 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7814378
18 April 2022 In-Service Inspection · Administrative Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7433058
1 April 2022 Administrative Inspection · Drydock Exam · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7425026
10 May 2021 In-Service Inspection · Plan Review "T" Boat · COI Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7194469
30 December 2019 COI Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6880731
7 May 2018 In-Service Inspection · Hull Examination · Internal Structural Exam · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6408338
10 May 2017 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6138629
26 April 2016 COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5858721
29 July 2015 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5200041
18 August 2014 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4958404
17 March 2014 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4817454
27 January 2012 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4233212
20 January 2011 Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3928359
4 February 2010 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3675951
14 January 2009 Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3394525
12 February 2008 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3146694
29 January 2008 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3141341
22 February 2007 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2875758
7 February 2007 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2868401
8 February 2006 Hull Examination · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2581651
26 January 2006 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2573852
9 February 2005 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2289214
12 October 2004 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2218971
9 June 2004 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2093361
22 January 2004 Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1990244
16 January 2003 Administrative Inspection · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1732053
16 January 2002 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1479844
18 September 2001 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1440558
31 January 2001 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1384661
11 January 2000 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 815242
1 October 1999 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1413605
16 September 1999 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1119840
21 January 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1123332
14 December 1998 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1453536
16 January 1998 Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1372090
16 December 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1414909
27 January 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1407815
16 October 1996 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 845428
8 February 1996 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1457319
20 December 1995 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination · Plan Review "T" Boat
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1355611

Deficiency record · 50

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 July 2025 Resolved
The lights prescribed in these Rules shall have an intensity... so as to be visible at the following minimum ranges: In a vessel of 12 meters or more in length but not less 50 meters in length: a sternlight, 2 miles. The vessel's sternlight was inoperable. - 33 CFR 83.22(b)(ii)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 August 2025
Resolution: Vessel rep. provided picture showing sternlight replaced / functioning properly. Picture uploaded to deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 July 2025 Resolved
A vessel on a lakes, bays, and sounds or rivers route must carry: three hand red flare distress signals, and three hand orange smoke distress signals. One of the following may be substituted for any of the hand orange smoke distress signals: a rocket parachute flare, a hand red flare distress signal, a floating orange smoke distress signal. Three of the vessel's distress signals are expired. 46 CFR 180.68(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 20 August 2025
Resolution: Vessel rep. provided picture of new orange smoke distress signals.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 31 July 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel's crew was not able to verify up-to-date electronic charts. 46 CFR 184.420(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 20 August 2025
Resolution: Vessel rep. provided picture of chart update card for the Garmin equipment on board.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 31 July 2025 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation. Vessel operator could not verify that the DSC will be fully functional without a latitude and longitude DSC transmission. 47 CFR 80.905(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 20 August 2025
Resolution: Vessel rep. provided picture showing newly installed VHF radio programmed with lat/long.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 18 July 2025 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Vessel's Master does not hold a valid marine operator permit. 47 CFR 80.159(e)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2025
Resolved 28 August 2025
Resolution: Received satisfactory evidence that Master passed exam and will receive Marine Radio Operator's Permit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 October 2023 Resolved
Radio transmitting and receiving installations or radiotelephones are required on certain vessels carrying passengers. Details...set forth in the regulations of the Federal Communications Commission (47 CFR Chapter 1). "...stations in the maritime service must be licensed by the FCC.." and "...will normally be issued for a term of ten years.." Vessel FCC station license and radiotelephony certificate where both expired. Provide documentation that both certificates have been updated to the satisfaction of U.S. Coast Guard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2023
Resolved 9 November 2023
Resolution: Documentation provided showing updated FCC certificates.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 October 2023 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. The vessel has not requested an inspection more than 3 months after the anniversary date. Contact the local OCMI to schedule and complete the required inspection prior to the carriage of passengers. - 46 CFR 176.500(b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2023
Resolution: Annual inspection completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 December 2019 Resolved
176.502: To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) and your Certificate of Inspection must be endorsed. The current Certificate of Inspection is invalid due to the vessel not completing the required annual inspection. The vessel must complete an annual inspection prior to carrying passengers. Vessel must submit temporary repair proposal for approval to moving the vessel to a shipyard for repairs.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 30 January 2020
Resolved 23 June 2022
Resolution: Vessel has completed repairs as shipyard, and completed COI-REN.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 December 2019 Resolved
Subsequent inspections for certification. (a) An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, and equipment. The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. During exam it was found, (in the fuel tank room aft bilge pocket, center line, starboard side of bilge pocket), that the vessel has a seepage hole that has a constant flow of seawater entering the vessel. Prior to the carriage of passengers vessel must enter dry dock for an ISE and Dry dock Inspection to discover the extent of the damage and submit a repair proposal to the Coast Guard for approval prior to the commencement of any work.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2020
Resolved 12 April 2021
Resolution: Drydock / ISE / Hull Exam completed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 December 2019 Resolved
Subsequent inspections for certification. (a) An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, and equipment. The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. During exam it was found, on the port aft section of vessel hull, that there is extensive damage to the skin of the vessel just above the water line to include structural failure due to extensive damage to the aft port corner of the vessel super structure. Prior to the carriage of passengers vessel must enter dry dock for an ISE and Dry dock Inspection to discover the extent of the damage and submit a repair proposal to the Coast Guard for approval prior to the commencement of any work.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2020
Resolved 12 April 2021
Resolution: Damage survey (Port Hull section) completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 December 2019 Resolved
Fill pipes and sounding pipes must be so arranged that overflow of liquid or vapor cannot escape to the inside of the vessel. During inspection it was discovered the vessel's fuel fill line was leaking into the fuel tank room, port side of tank, filling voids and bilge with fuel. Prior to the carriage of passengers vessel must enter dry dock for an ISE and Dry dock Inspection to discover the extent of the damage and submit a repair proposal to the Coast Guard for approval prior to the commencement of any work.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2020
Resolved 12 April 2021
Resolution: Fuel piping leak inspected; satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 December 2019 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. All equipment, including switches, fuses, lamp-holders, etc., must be suitable for the voltage and current utilized. Receptacle outlets of the type providing a grounded pole or a specific direct current polarity must be of a configuration that will not permit improper connection. All electrical equipment and circuits must be clearly marked and identified. Any cabinet, panel, box, or other enclosure containing more than one source of power must be fitted with a sign warning persons of this condition and identifying the circuits to be disconnected. During inspection it was found various equipment on upper deck was not marine grade equipment (i.e. power strips, bubble machine, fog machine, ect. as well as junction boxes on upper level that were not properly sealed with bare wires extruding from the enclosures. Also to include improper lighting fixture that was either melted or burnt from improper usage on the starboard side of the fuel tank.) Prior to the carriage of passengers vessel must enter dry dock for an ISE and Dry dock and COI Renewal Inspection's to discover the extent of the damage and submit a repair proposal to the Coast Guard for approval prior to the commencement of any work.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2020
Resolved 14 April 2022
Resolution: Vessel has completed a credit drydock.
Engineering › Bilge Water Management System › Piping
Issued 31 May 2018 Resolved
A SUBMERSIBLE ELECTRIC BILGE PUMP DISCHARGE LINE IS REQUIRED A POSITIVE SHUTOFF VALVE AT THE HULL PENETRATION. VESSEL FOR PEAK ELECTRIC BILGE PUMP DOES NOT HAVE A POSITIVE SHUTOFF VALVE INSTALLED.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 25 June 2018
Resolution: Vessel Installed positive stop valve
Construction/Loadline › Hull › Hull Plating
Issued 31 May 2018 Resolved
PROPOSED REPAIRS OR ALTERATIONS SHALL BE APPROVED BY THE COGNIZANT OFFICER IN CHARGE MARINE INSPCTIONS. 1. VESSEL MADE FIBERGLASS REPAIRS TO THEIR PORT QUARTER HULL JUST ABOVE THE WATERLINE. VESSEL REPRESENTATIVE IS TO SUBMIT A PROPOSAL FOR REPAIRS ALREADY COMPLETED TO INCLUDE LAYUP SCHEDULE, RESIGN, SDS FOR RESGN, AND REPAIR PLAN. 2. VESSEL ALTERED THE HULL BY CUTTING OUT ACCESS HOLES AND INSTALLING ACCESS PLATES IN ORDER TO INSTALL SUPPORT PLATES UNDER THE DECK RAILING POSTS. VESSEL REPRESENTATIVE WAS INSTRUCTED TO PROVIDE A REPAIR PROPOSAL TO INCLUDE THE SIZE OF HOLE BEING CUT, LOCATION, AND MEANS OF SEALING THE HOLES ONCE FINISHED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 29 June 2018
Resolution: Vessel completed proper repairs
Construction/Loadline › Penetrations › Pipe Flange
Issued 31 May 2018 Resolved
A PENETRATION IN A WATERTIGHT BULKHEAD MUST BE MADE WATERTIGHT. VESSEL HAS A THROUGH HULL FITTING MADE OF PVC THAT ALLOWS WATER TO DRAIN FROM THEIR MAIN DECK PORT SIDE STORAGE LOCKER OVERBOARD WHICH IS NOT WATERTIGHT. VESSEL REPRESENTATIVE INSTRUCTED TO PROVIDE A REPAIR PROPOSAL TO INSTALL A PROPER PENETRATION FOR THE DRAIN LINE.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 29 June 2018
Resolution: Vessel completed proper repairs
Construction/Loadline › Hull › Bottom Plating
Issued 31 May 2018 Resolved
PROPOSED REPAIRS OR ALTERATIONS SHALL BE APPROVED BY THE COGNIZANT OFFICER IN CHARGE MARINE INSPCTIONS. 1. PORT QUARTER HULL UNDER THE EXHAUST OUTLET HAS DAMAGED FIBERGLASS. VESSEL REPRESENTATIVE WILL PROVIDE A REPAIR PROPOSAL AND LAYUP SCHDULE PRIOR TO ENACTING REPAIRS. 2. PORT QUARTER HULL AT THE END OF THE EXHAUST OUTLET HAS DAMAGED FIBERGLASS. VESSEL REPRESENTATIVE WILL PROVIDE A REPAIR PROPOSAL AND LAYUP SCHEDULE PRIOR TO ENACTING REPAIRS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 29 June 2018
Resolution: Vessel completed proper repairs
Construction/Loadline › Hull › Bottom Plating
Issued 31 May 2018 Resolved
DURING THE EXAMINATION ALL ACCESSIBLE PARTS OF THE VESSEL'S UNDERWATER BODY SHALL BE MADE AVAILABLE FOR EXAMINATION. 1. PORT HULL PLATING BELOW THE WATERLINE HAS MULTIPLE SOFT SPOTS THAT REQUIRE PAINT REMOVAL TO INSPECT FOR FIBERGLASS DAMAGE. AREAS MARKED IN ORANGE CRAYON. 2. STARBOARD HULL PLATING BELOW THE WATERLINE HAS MULTIPLE SOFT SPOTS THAT REQUIRE PAINT REMOVAL TO INSPECT FOR FIBERGLASS DAMAGE. AREAS MARKED IN ORANGE CRAYON. 3. PORT SIDE KEEL PLATING HAS FIBERGLASS PROTECTING MATERIAL MISSING. FIBERGLASS PROTECTIVE MATERIAL NEEDS TO BE REPLACED PRIOR TO BOTTOM PAINT BEING APPLIED. 4. STARBOARD SIDE KEEL PLATING HAS FIBERGLASS PROTECTING MATERIAL MISSING. FIBERGLASS PROTECTIVE MATERIAL NEEDS TO BE REPLACED PRIOR TO BOTTOM PAINT BEING APPLIED.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 29 June 2018
Resolution: Vessel completed proper repairs
Construction/Loadline › Hull › Hull Plating
Issued 25 May 2018 Resolved
02199 - A vessel exposed to salt water more than three months in a twelve month period must undergo a drydock examination and internal structural examination at least once every two years. Vessel's last drydock examination was more than two years ago on 27 April 2016. 46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2018
Resolution: Vessel completed a credited dry dock exam.
Engineering › Bilge Water Management System › Pump
Issued 21 May 2018 Resolved
13104 - All vessels shall be provided with bilge pumps in accordance with table 182.25-10(a). Vessels installed bilge pump does not gain suction and or prime. 46 CFR 182.25-10(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 July 2018
Resolution: Vessel was able to prove proper operation of the bilge pump.
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 May 2018 Resolved
13104 - Visual and audible alarm must be provided at the operating station to indicate high water level in the bilges. Alarm for the forepeak and engine room was not operable. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2018
Resolution: Vessel was able to prove proper operation of the bilge alarms.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 21 May 2018 Resolved
02101 - Each watertight door, an indicator must be installed in the pilothouse and at each other vessel operating station from which the door is not visible. The indicator must show whether the door is open or closed. Vessel’s watertight door located in the engine room indicator is inoperable. 46 CFR 170.270(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2018
Resolution: Vessel was able to prove proper operation of the engine room door indicator located on the bridge.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 21 May 2018 Resolved
11118 - Life jackets must be marked with Type I retroreflective material approved in 46 CFR 164.018. Life jackets are marked with Type II retroreflective material. 46 CFR 185.604(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2018
Resolution: Life jackets were properly marked with Type I retroreflective material approved in 46 CFR 164.018.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 May 2018 Resolved
09233 - Suitable covers, guards or rails shall be installed in way of all exposed hazards. Anchor windlass is accessible to passengers on passenger deck. 46 CFR 177.35-15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2018
Resolution: Vessel repaired machinery guards for the Anchor Windless.
Engineering › Fuel Oil Service System › Valve
Issued 21 May 2018 Resolved
07199 - Fuel shutoff valves shall be marked in at least 1-inch letters indicating the direction of operation. Fuel shutoff valves were not marked with the direction of operation. 46 CFR 185.30-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 2 July 2018
Resolution: Fuel shutoff valves were properly marked in at least 1-inch letters indicating the direction of operation.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 21 May 2018 Resolved
02199 - The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Hailing port is not marked. 46 CFR 185.30-1 46 CFR 67.123(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2018
Resolution: The hailing port of the vessel was properly marked on some clearly visible exterior part of the stern of the vessel.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 21 May 2018 Resolved
02116 - Openings in watertight bulkheads must have means to make them watertight. Vessel has two holes in the watertight bulkhead between the engine room and tank room. 46 CFR 177.13-1 46 CFR 171.114
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2018
Resolution: Vessel properly sealed two holes in the watertight bulkhead between the engine room and tank room.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 May 2018 Resolved
02118 - Railings and bulwarks and their attachment to the hull structure shall be inspected. Discovered crack in FRP at the rail connection to the hull. 46 CFR 176.802(a)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2018
Resolved 2 July 2018
Resolution: Crack in FRP at the rail connection was properly repaired.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 21 May 2018 Resolved
14402 - MSD must be marked with manufacture, name and model number, manufacture date, serial number, whether the device is certified for an inspected vessel, and Type. During internal structural examination (ISE), marine inspector noticed an overboard valve without a handle that does not indicate valve position and noticed a leak at the section where valve connects to & penetrates the hull. Upon further examination, marine inspector could not find identification for the type of MSD installed. 46 CFR 184.704 33 CFR 159.55
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2018
Resolution: MSD was properly marked with manufacture, name and model number, manufacture date, serial number, whether the device is certified for an inspected vessel, and Type.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 21 May 2018 Resolved
13199 - Exhaust piping shall be gas-tight throughout it's length. During internal structural examination (ISE), marine inspector noticed signs of possible leaks on PORT & STBD mufflers and AFT exhaust piping. Vessel representative shall get vessel underway to determine if signs of possible leaks are active and in need of repair. 46 CFR 182.20-20 46 CFR 182.15-20
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2018
Resolution: Engine showed no signs of an exhaust leak.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 March 2014 Resolved
Remove or repair dead end wires in machinery space & steering space. 46CFR183.200
Action required: 705 - Other - as specified
Due 26 March 2014
Resolved 26 March 2014
Resolution: All dead end wires removed.
Fire Fighting › Fire Hoses › Material
Issued 17 March 2014 Resolved
Replace hose for main fire pump due to multiple pinholes in hose. 46CFR181.320
Action required: 705 - Other - as specified
Due 26 March 2014
Resolved 26 March 2014
Resolution: Fire hoses replaced in kind with brand new units.
Stability › Weathertight Integrity › General
Issued 4 February 2010 Resolved
Permanently attach the hatch cover to the steering compartment with a line or chain.
Action required: 705 - Other - as specified
Due 5 March 2010
Resolved 19 April 2010
Resolution: Item corrected.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 4 February 2010 Resolved
Repair or replace the fire/bilge pump located on the stbd MDE.
Action required: 705 - Other - as specified
Due 5 March 2010
Resolved 19 April 2010
Resolution: Fire pump replaced.
Engineering › Fuel Oil Service System › Hose
Issued 4 February 2008 Resolved
Replace double hose clamps missing on both main diesel engines.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 12 February 2008
Resolution: Item corrected.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 4 February 2008 Resolved
Install belt cover on starboard main diesel engine.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 12 February 2008
Resolution: Item corrected.
Electrical › Lighting (service) › Outlet Box
Issued 4 February 2008 Resolved
Replace all cable receptacles with watertight covers.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 12 February 2008
Resolution: Item corrected.
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 February 2007 Resolved
Add sign for the "Remote Emergency Fuel Shutoff Valve".
Action required: 705 - Other - as specified
Due 5 March 2007
Resolved 21 February 2007
Resolution: Sign posted.
Construction/Loadline › Hull › Hull Plating
Issued 7 February 2007 Resolved
Make permanent repairs to the 3" gash in the Starboard Quarter, 2 feet above the waterline.
Action required: 705 - Other - as specified
Due 5 March 2007
Resolved 21 February 2007
Resolution: Hull repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 February 2007 Resolved
Replace the light covers in the forward stateromm and on the 2nd deck.
Action required: 705 - Other - as specified
Due 5 March 2007
Resolved 21 February 2007
Resolution: Light fixtures repaires.
Engineering › Diesel Engine (propulsion-direct drive) › Nozzle, Injection (fuel injection)
Issued 7 February 2007 Resolved
Renew the dry rotted fuel lines on the port and starboard MDE's prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 March 2007
Resolved 21 February 2007
Resolution: 7 fuel lines renewed.
Fire Fighting › Fire Pumps › Pressure
Issued 7 February 2007 Resolved
Add a gauge to the main fire pump.
Action required: 705 - Other - as specified
Due 5 March 2007
Resolved 21 February 2007
Resolution: Gauge added.
Electrical › Electrical Distribution System (service)
Issued 22 January 2004 Resolved
Relocate Electrical breaker box in the STBD closet. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2004
Resolved 8 June 2004
Resolution: Satisfactory located the electrical box disconnect, all sat.
Engineering › Compressed Air System (control) › Compressor
Issued 22 January 2004 Resolved
Relocate A/C compressor unit in the STBD closet.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2004
Resolved 12 October 2004
Resolution: Conducted def check of the relocate A/C compressor, all sat.
Engineering › Freshwater System (cylinder head cooling)
Issued 22 January 2004 Resolved
Replace raw water intake hose for the STBD and port engine. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 16 February 2004
Resolved 8 June 2004
Resolution: Conducted repair check, all sat.
Electrical
Issued 20 December 1995 Resolved
PROVE PROPER OPERATION OF THE GENERATOR FREQUENCY METER LOCATED IN PILOT HOUSE.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Accommodation/Occupational Safety
Issued 20 December 1995 Resolved
PROVIDE CREW LADDER TO TOP OF PILOT HOUSE ALLOW EMERGENCY LAUNCHING OF VSLSLIFEFLOATS.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Navigation
Issued 20 December 1995 Resolved
PROVIDE VALID COMPASS DEVIATION CARD.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Navigation
Issued 20 December 1995 Resolved
ON ARRIVAL AND PRIOR TO CARRING ANY PASSENGERS, CONTACT MSO HOUSTON FOR INSPECTION AFTER ARRIVAL AT HOMEPORT.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Engineering
Issued 20 December 1995 Resolved
PROVE OPERATION OF BOTH MAIN ENGINE OVERSPEED CONTROL DEVICES IAW ABS RULE 34.11.6, FOR MAIN ENGINES OF 300HP OR GREATER.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Accommodation/Occupational Safety
Issued 20 December 1995 Resolved
COMPLETE INSTALLATION AND PROVE PROPER OPERATION OF A/C SYSTEMS.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.