MAURY USCG vessel records Sign in
← All vessels

ATLANTIC TRADER

ATLANTIC TRADER is a 1988 freight ship. The Coast Guard has recorded 27 inspections since 1998, most recently in June 2006, along with 24 deficiencies and 5 operational controls.

Records from 1998 to 2006. Most recent: inspection, 19 June 2006.

Built
1988
Last inspected
19 June 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8922539 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
421574
Flag
CYPRUS
—
Maury page id
psix-421574

Inspections, by type

…with no type recorded17
Years with a record 6 calendar years (1998–2006)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it15903 - Convention (Subpart B), Gross Ton
15903 - Regulatory (Subpart C or D), Gross Ton
8105 - Convention (Subpart B), Net Ton
8105 - Regulatory (Subpart C or D), Net Ton
17820 - Dead Weight, Ton
26770 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

19 June 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2684575
28 April 2006 ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2635489
4 January 2006 Deficiency Check · Random ISPS/MTSA/PSC
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2560517
23 September 2005 MARPOL Annex I Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2499652
20 September 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2497469
18 September 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2498772
14 September 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2492189
28 June 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2406786
20 June 2005 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2396214
18 June 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2394632
17 June 2005 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2393313
1 March 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2301313
1 March 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2301611
28 February 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2316847
7 December 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2255219
14 October 2004 ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2220627
15 June 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2098889
24 November 2003 Re-Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1953233
12 June 2003 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1815457
3 April 2003 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1767406
27 June 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 291206
4 June 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 290332
8 April 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 288970
20 March 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 288369
8 December 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 423456
5 December 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 69194
13 September 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 420364

Deficiency record · 24

Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 23 September 2005 Resolved
Excessive oil accumulated inside of generator containment and on the surfaces of number 1, 2, and 3 generators.
Condition: Improper/Lack of Maintenance
Due 23 October 2005
Resolved 3 January 2006
Resolution: Due to age of vessel, small amounts of oil will leak into containment. Engineers have taken appropriate measures to clean oil during rounds.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 20 June 2005 Resolved
Chief Mate just made master and did not have old chief mates license to match documentation of flag state.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2005
Resolution: Flag state faxed a copy of the chief mates old license which was still valid.
Engineering › Steering Gear System › Valve
Issued 20 June 2005 Resolved
When testing gear system relief valves hydraulic fitting to valve no. 12 failed and sprayed fluid throughout steering room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2005
Resolution: Class went aboard vessel and inspected. Class found that repairs made were satifactory.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 20 June 2005 Resolved
When inspected found cooling air ducts taped to main switchboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2005
Resolution: Engineering removed the ducting and class came aboard and found that the existing a/c system was sufficient.
Construction/Loadline › Hull › Hull Plating
Issued 28 February 2005 Resolved
Vessel hull was torn 1 foot by 4 foot opening by an allision between the vessel and pier. Permanent repairs will be made 02 April 2005 in South Africa.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 April 2005
Resolved 26 April 2005
Resolution: AS PER BV "OCCASIONAL SURVEY HULL AFLOAT FOR INSPECTION & DELETION OF REC. 5.1 REC 5.1 NOW DEALT WITH. DURBAN, SOUTH AFRICA
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 December 2004 Resolved
The subject vessel wishes to enter the Port of New York on or about December 8, 2004 with an inoperable secondary radar and has arranged to effect repairs prior to departing the Port of New York.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 December 2004
Resolved 9 December 2004
Resolution: Vessel sent via fax a sevice report from Sperry Marine [name withheld] stating that the reapairs to the secondary radar were made and that the radar is now in operation.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 15 June 2004 Resolved
VESSEL MUST REPAIR LEAKING OIL PIPE IN AUXILIARY GENERATOR ROOM. PIPE IS LEAKING AND LEAKS ARE BEING COLLECTED BY SODA CANS AND FUNNELS.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2004
Resolved 22 June 2004
Resolution: On 15Jun2004 [name withheld] attested to the satisfactory repair of the lube oil pipe for Aux. engine.
Accommodation/Occupational Safety › Occupational Safety
Issued 24 November 2003 Resolved
REPLACE WASTED STEP IN FRONT OOF CARPENTER REPAIR SHOP STBD SIDE ON MAIN DECK LEGACY COMPONENT DESC: STEP
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 December 2003
Resolved 28 November 2003
Construction/Loadline › Structures
Issued 24 November 2003 Resolved
FRACTURES LOCATED PORT AND STBD SIDE MAIN DECK ENGINE ROOM VENTHOUSE FWD OF DECKHOUSE FRACTURE WHERE BULWARK MEETS VENTHOUSE FWD AND AFT. REPAIR AS ORIGINAL, ALSO FRACTURE PORT SIDE MIDSHIP ON BULWARK FRAME 87, REPAIR AS ORIGINAL LEGACY COMPONENT DESC: FAN HOUSING
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 December 2003
Resolved 28 November 2003
Pollution Prevention/Response › Prevention Equipment
Issued 3 April 2003 Resolved
Oily Water Seperator leaking in way of the gasket that seals the seperator. OWS can not be used in the United States or its territorial waters until certified by Class. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 3 May 2003
Resolved 11 April 2003
Resolution: CLASS SOCIETY SURVEYOR ATTESTED TO PROPER REPAIR.
Pollution Prevention/Response › Prevention Equipment
Issued 3 April 2003 Resolved
MSD appears to be wasted. Repair to the satisfaction of Class Surveyor. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 2 June 2003
Resolution: Rcv''d BV Class Report dated 21May03, MSD renewed.
Construction/Loadline › Hull
Issued 3 April 2003 Resolved
Fracture found in port side coaming at frame 102. Fracture extends vertical into weld and possibly the deck. Class Surveyor to reccomend repairs. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 April 2003
Resolved 11 April 2003
Resolution: CLASS SOCIETY SURVEYOR ATTESTED TO PROPER REPAIR
Construction/Loadline › Hull
Issued 3 April 2003 Resolved
Fracture found at base of port side stiffeners attached to side rail at location frames 119 and 87. Fractures to be repaired. LEGACY COMPONENT DESC: Stiffener
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 May 2003
Resolved 11 April 2003
Resolution: CLASS SOCIETY SURVEYOR ATTESTED TO PROPER REPAIR
Deck/Cargo › Holds/Tanks
Issued 3 April 2003 Resolved
Knife edge at access hatch to boesnhole is wasted comprimissing watertight integrity. Repair to the satisfaction of Class Surveyor. LEGACY COMPONENT DESC: Hatch
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 May 2003
Resolved 11 April 2003
Resolution: CLASS SOCIETY SURVEYOR ATTESTED TO PROPER REPAIR
Accommodation/Occupational Safety › Medical/First Aid
Issued 3 April 2003 Resolved
Door to hospital space is corroded and not in good working order. Renew and repair. LEGACY COMPONENT DESC: Hospital Space
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 May 2003
Resolved 11 April 2003
Resolution: CLASS SOCIETY SURVEYOR ATTESTED TO PROPER REPAIR
Accommodation/Occupational Safety › Medical/First Aid
Issued 3 April 2003 Resolved
Habability of hospital space in overall poor condition. Hospital to be brought up to requirements in ILO 147 LEGACY COMPONENT DESC: Hospital Space
Action required: 705 - Other - as specified
Due 3 May 2003
Resolved 11 April 2003
Resolution: CLASS SOCIETY SURVEYOR ATTESTED TO PROPER REPAIR
Lifesaving
Issued 20 March 2001 Resolved
VESSELS' LIFERAFTS NEED SERVICING, TEMPORARY RAFTS ONBOARD UNTIL SERVICING IS COMPLETE.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 20 March 2001 Resolved
LIFE LIGHT ON LIFEBOUY, PORT SIDE AFT DOES NOT LIGHT.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Fire Fighting
Issued 20 March 2001 Resolved
IAW SOLAS 74/78 VESSELS' PORTABLE FIRE EXTINGUISHERS ARE PAST DUE FOR SERVICING.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Lifesaving
Issued 20 March 2001 Resolved
EXPIRED PYROTECHNICS ON BRIDGE.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Lifesaving
Issued 20 March 2001 Resolved
EMERGENCY ESCAPE FROM ENGINE ROOM USED AS STORAGE
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Deck/Cargo
Issued 8 December 1998 Resolved
No operations are permitted with ship's cranes until a detailed (UT, radiological, etc.) inspection of the foundation welds have been conducted and class results forwarded to the USCG. (#6 crane failed due to improper welding.)
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Construction/Loadline
Issued 8 December 1998 Resolved
Make permanent repairs to the damage to #4 cargo hatch cover panels and stbd wheel guide. Also make required repairs to any damage on the tank topin the cargo hold where affected by the falling crane. Complete prior to departure.
Condition: Unknown
Due 10 December 1998
Resolved 21 December 1998
Documentation
Issued 13 September 1998 Resolved
Sefety Equipment Certificate expired, SOLAS 74 (amended), Ch. I, Reg. 12
Condition: Unknown
Due 13 September 1998
Resolved 28 September 1998

Ownership record