← All vessels
ATLANTIC TRADER
Freight Ship · Ro-Ro Cargo Ship class · Built 1980s · USCG East District (CGD-E) · Other hulls named ATLANTIC TRADER
ATLANTIC TRADER is a 1988 freight ship. The Coast Guard has recorded 27 inspections since 1998, most recently in June 2006, along with 24 deficiencies and 5 operational controls.
Records from 1998 to 2006. Most recent: inspection, 19 June 2006.
- Built
- 1988
- Last inspected
- 19 June 2006
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8922539 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRAO3
421574
Flag
CYPRUS
—
Maury page id
psix-421574
Inspections, by type
…with no type recorded17
Years with a record
6 calendar years (1998–2006)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it15903 - Convention (Subpart B), Gross Ton
15903 - Regulatory (Subpart C or D), Gross Ton
8105 - Convention (Subpart B), Net Ton
8105 - Regulatory (Subpart C or D), Net Ton
17820 - Dead Weight, Ton
26770 - Displacement, Ton
15903 - Regulatory (Subpart C or D), Gross Ton
8105 - Convention (Subpart B), Net Ton
8105 - Regulatory (Subpart C or D), Net Ton
17820 - Dead Weight, Ton
26770 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
19 June 2006
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2684575
28 April 2006
ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2635489
4 January 2006
Deficiency Check · Random ISPS/MTSA/PSC
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2560517
23 September 2005
MARPOL Annex I Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2499652
20 September 2005
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2497469
18 September 2005
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2498772
14 September 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2492189
28 June 2005
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2406786
20 June 2005
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2396214
18 June 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2394632
17 June 2005
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2393313
1 March 2005
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2301313
1 March 2005
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2301611
28 February 2005
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2316847
7 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2255219
14 October 2004
ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2220627
15 June 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2098889
24 November 2003
Re-Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1953233
12 June 2003
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1815457
3 April 2003
Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1767406
27 June 2001
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 291206
4 June 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 290332
8 April 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 288970
20 March 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 288369
8 December 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 423456
5 December 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 69194
13 September 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 420364
Deficiency record · 24
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 23 September 2005
Resolved
Excessive oil accumulated inside of generator containment and on the surfaces of number 1, 2, and 3 generators.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 20 June 2005
Resolved
Chief Mate just made master and did not have old chief mates license to match documentation of flag state.
Engineering › Steering Gear System › Valve
Issued 20 June 2005
Resolved
When testing gear system relief valves hydraulic fitting to valve no. 12 failed and sprayed fluid throughout steering room.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 20 June 2005
Resolved
When inspected found cooling air ducts taped to main switchboard.
Construction/Loadline › Hull › Hull Plating
Issued 28 February 2005
Resolved
Vessel hull was torn 1 foot by 4 foot opening by an allision between the vessel and pier. Permanent repairs will be made 02 April 2005 in South Africa.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 December 2004
Resolved
The subject vessel wishes to enter the Port of New York on or about December 8, 2004 with an inoperable secondary radar and has arranged to effect repairs prior to departing the Port of New York.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 15 June 2004
Resolved
VESSEL MUST REPAIR LEAKING OIL PIPE IN AUXILIARY GENERATOR ROOM. PIPE IS LEAKING AND LEAKS ARE BEING COLLECTED BY SODA CANS AND FUNNELS.
Accommodation/Occupational Safety › Occupational Safety
Issued 24 November 2003
Resolved
REPLACE WASTED STEP IN FRONT OOF CARPENTER REPAIR SHOP STBD SIDE ON MAIN DECK LEGACY COMPONENT DESC: STEP
Construction/Loadline › Structures
Issued 24 November 2003
Resolved
FRACTURES LOCATED PORT AND STBD SIDE MAIN DECK ENGINE ROOM VENTHOUSE FWD OF DECKHOUSE FRACTURE WHERE BULWARK MEETS VENTHOUSE FWD AND AFT. REPAIR AS ORIGINAL, ALSO FRACTURE PORT SIDE MIDSHIP ON BULWARK FRAME 87, REPAIR AS ORIGINAL LEGACY COMPONENT DESC: FAN HOUSING
Pollution Prevention/Response › Prevention Equipment
Issued 3 April 2003
Resolved
Oily Water Seperator leaking in way of the gasket that seals the seperator. OWS can not be used in the United States or its territorial waters until certified by Class. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Pollution Prevention/Response › Prevention Equipment
Issued 3 April 2003
Resolved
MSD appears to be wasted. Repair to the satisfaction of Class Surveyor. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Construction/Loadline › Hull
Issued 3 April 2003
Resolved
Fracture found in port side coaming at frame 102. Fracture extends vertical into weld and possibly the deck. Class Surveyor to reccomend repairs. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull
Issued 3 April 2003
Resolved
Fracture found at base of port side stiffeners attached to side rail at location frames 119 and 87. Fractures to be repaired. LEGACY COMPONENT DESC: Stiffener
Deck/Cargo › Holds/Tanks
Issued 3 April 2003
Resolved
Knife edge at access hatch to boesnhole is wasted comprimissing watertight integrity. Repair to the satisfaction of Class Surveyor. LEGACY COMPONENT DESC: Hatch
Accommodation/Occupational Safety › Medical/First Aid
Issued 3 April 2003
Resolved
Door to hospital space is corroded and not in good working order. Renew and repair. LEGACY COMPONENT DESC: Hospital Space
Accommodation/Occupational Safety › Medical/First Aid
Issued 3 April 2003
Resolved
Habability of hospital space in overall poor condition. Hospital to be brought up to requirements in ILO 147 LEGACY COMPONENT DESC: Hospital Space
Lifesaving
Issued 20 March 2001
Resolved
VESSELS' LIFERAFTS NEED SERVICING, TEMPORARY RAFTS ONBOARD UNTIL SERVICING IS COMPLETE.
Lifesaving
Issued 20 March 2001
Resolved
LIFE LIGHT ON LIFEBOUY, PORT SIDE AFT DOES NOT LIGHT.
Fire Fighting
Issued 20 March 2001
Resolved
IAW SOLAS 74/78 VESSELS' PORTABLE FIRE EXTINGUISHERS ARE PAST DUE FOR SERVICING.
Lifesaving
Issued 20 March 2001
Resolved
EXPIRED PYROTECHNICS ON BRIDGE.
Lifesaving
Issued 20 March 2001
Resolved
EMERGENCY ESCAPE FROM ENGINE ROOM USED AS STORAGE
Deck/Cargo
Issued 8 December 1998
Resolved
No operations are permitted with ship's cranes until a detailed (UT, radiological, etc.) inspection of the foundation welds have been conducted and class results forwarded to the USCG. (#6 crane failed due to improper welding.)
Construction/Loadline
Issued 8 December 1998
Resolved
Make permanent repairs to the damage to #4 cargo hatch cover panels and stbd wheel guide. Also make required repairs to any damage on the tank topin the cargo hold where affected by the falling crane. Complete prior to departure.
Documentation
Issued 13 September 1998
Resolved
Sefety Equipment Certificate expired, SOLAS 74 (amended), Ch. I, Reg. 12
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.