Records from 1984 to 1988. Most recent: inspection, 5 January 1988.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
5 January 1988
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1317474
13 October 1987
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1012338
7 February 1986
COI Inspection · Credit Drydock
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 995963
23 January 1986
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 995280
22 January 1986
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 995276
20 October 1985
Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1297855
19 October 1985
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 304933
10 October 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985837
30 September 1985
Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 992325
24 September 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296104
12 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980011
29 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 981917
28 February 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1285677
15 February 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1283714
8 January 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1283141
9 November 1984
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 298945
Lifesaving
Issued 7 February 1986
Resolved
CONDUCT A WEIGHT TEST ON THE PORT LIFEBOAT DAVIT.
Condition: Unknown
Due 7 February 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 7 February 1986
Resolved
PROVE PROPER OPERATION OF GENERAL ALARM BELLS.
Condition: Unknown
Due 7 February 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 7 February 1986
Resolved
HOLD A FIRE AND LIFEBOAT DRILL AND PROVE PROPER OPERATION OF PORT LIFE BOAT.
Condition: Unknown
Due 7 February 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 7 February 1986
Resolved
PROVE PROPER OPERATION OF THE L.O. GRAVITY TANK, LOW L.O. LEVEL ALARMS.
Condition: Unknown
Due 7 February 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 7 February 1986
Resolved
PROVIDE A COPY OF TEST REPORTS ON LOW SEA SUCT. VALVE REPAIRS.
Condition: Unknown
Due 7 February 1986
Resolved 7 February 1986
Navigation
Issued 7 February 1986
Resolved
PROVE THE PROPER OPERATION OF STEERING GEAR POWER FAILURE ALARM.
Condition: Unknown
Due 7 February 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 7 February 1986
Resolved
PROVE THE PROPER OPERATION OF THE EOT POWER FAILURE ALARM.
Condition: Unknown
Due 7 February 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 7 February 1986
Resolved
PROVE THE PROPER OPERATION OF THE REMOTE F.O. SHUT OFF VALVES.
Condition: Unknown
Due 7 February 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 7 February 1986
Resolved
PROVE THE PROPER OPERATION OF THE DC HEATER RELIEF VALVES.
Condition: Unknown
Due 7 February 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 7 February 1986
Resolved
PROVE THE PROPER OPERATION OF THE RELIEF VALVES ON BOTH H.P. EVAPORATORS.
Condition: Unknown
Due 7 February 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 7 February 1986
Resolved
PROVE THE PARALLEL OPERATION AND REVERSE POWER TRIPS ON #1,#2 DC GENS.
Condition: Unknown
Due 7 February 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 30 September 1985
Resolved
VESSEL REQUIRED TO BE DRYDOCKED WITHIN 10 DAYS, PRIOR TO 11 OCTOBER 1985.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Engineering
Issued 29 March 1985
Resolved
REMOVE DISASSEMBLE, AND THOROUGHLY INSPECTION AND REPAIR THE FORWARD MAIN CIRC LOW SUCTION VALVE.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Construction/Loadline
Issued 15 February 1985
Resolved
REPAIR WATERTIGHT DOOR POSITION INDICATOR FOR SHAFT ALLEY REMOTE OPERATING STATION.
Condition: Unknown
Due 15 February 1985
Resolved 15 February 1985
Electrical
Issued 15 February 1985
Resolved
DEMOSTRATE PUMPING AND SENSING OPERATIONS OF THE MARINE SANTATION DEVICE.
Condition: Unknown
Due 15 February 1985
Resolved 15 February 1985
Engineering
Issued 15 February 1985
Resolved
MAKE PERMANENT REPAIRS TO THE WASTED #8 DOUBLE BOTTOM VENT RISER.
Condition: Unknown
Due 15 February 1985
Resolved 15 February 1985
Electrical
Issued 15 February 1985
Resolved
REPAIR OR REPLACE SWITCHGEAR (HANDLES) FOR HOTEL SERVICE, REFER, CONTAINER CONTROLS (P401 & P402) AND MOTOR GENERATOR CONTROL SYSTEM.
Condition: Unknown
Due 15 February 1985
Resolved 15 February 1985
Electrical
Issued 15 February 1985
Resolved
FIT WHERE MISSING THE CLOSURE DEVICES FOR THE MOTOR CONTROLLER DOORS THROUGHOUT THE ENGINE SPACE.
Condition: Unknown
Due 15 February 1985
Resolved 15 February 1985
Electrical
Issued 15 February 1985
Resolved
PROPERLY FUZE THE DISTRIBUTION PANELS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 15 February 1985
Resolved 15 February 1985
Electrical
Issued 15 February 1985
Resolved
REFIT THE WOOD PROTECTION RAILING TO THE MAIN SWITCHBOARD REAR ACCESS AREA.
Condition: Unknown
Due 15 February 1985
Resolved 15 February 1985
Engineering
Issued 15 February 1985
Resolved
SPRAY SHIELDS WERE MISSING ARE TO BE FITTED TO THE FUEL OIL SYSTEM FLANGES FROM THE PUMP TO THE BOILER HEADERS.
Condition: Unknown
Due 15 February 1985
Resolved 15 February 1985