MAURY USCG vessel records Sign in
← All vessels

BAY RANGER

BAY RANGER is a freight ship. The Coast Guard has recorded 29 inspections since 1995, most recently in December 2010, along with 28 deficiencies and 6 operational controls.

Records from 1995 to 2010. Most recent: inspection, 27 December 2010.

Built
Not recorded
Last inspected
27 December 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9070723 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
421886
Flag
BAHAMAS, THE
—
Maury page id
psix-421886

Inspections, by type

…with no type recorded15
Years with a record 12 calendar years (1995–2010)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it24550 - Convention (Subpart B), Gross Ton
14450 - Convention (Subpart B), Net Ton
43125 - Dead Weight, Ton
50479 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

27 December 2010 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3916637
23 December 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3913025
22 December 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3914801
30 January 2009 PII Safety Exam · ISPS III Exam · Administrative Inspection · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3398200
27 May 2008 ISPS I Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3218198
26 May 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3219611
23 May 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3214776
7 December 2007 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3111055
18 November 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3100356
16 November 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3099438
30 October 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3089905
19 January 2006 Ballast Water Examination · NPV Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2569598
10 November 2005 ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2532297
10 October 2005 Spot Check · Deficiency Check · PII Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2506493
12 April 2005 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2329665
10 November 2004 MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2235103
5 November 2004 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2235786
25 February 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2014373
20 February 2004 Re-Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2009728
19 February 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2027476
26 December 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1969790
6 November 2003 Type not recorded
No type recorded · Station Georgetown · USCG Southeast District (CGD-SE) · Activity 1943417
23 July 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1855180
22 April 2002 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1604750
7 July 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 430326
4 October 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 420750
21 June 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987
16 June 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 418006
20 May 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 378266

Deficiency record · 28

Lifesaving › Lifeboat Equipment › Food Ration
Issued 27 December 2010 Resolved
Food rations for each person in the lifeboat as permitted to accommodate will be kept in airtight packaging. Vessel has a total of 12 food rations that are no longer airtight packaged. SOLAS 74 (2004 consolidated) CH. III/13.1.4 / LSA CODE IV/4.4.8.12 (40C)
Action required: 705 - Other - as specified
Due 3 January 2011
Resolved 28 December 2010
Resolution: Vessel provided proof of new lifeboat rations and documentation supporting the purchase of 12 new lifeboat rations.
Navigation › Piloting/Steering › Gyro Compass
Issued 22 December 2010 Resolved
VESSEL SUBMITTED LOD FOR INOP GYRO COMPASS. 33CFR164.35(d)/(e)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2010
Resolution: Vessel submitted a Tech Report attesting to the proper repair and operation of the Gyro Compass.
Navigation › Piloting/Steering › Gyro Compass
Issued 18 November 2007 Resolved
Gyro compass is not operational and flag administration has issued authorization for the vessel to sail for one loaded voyage to Columbia , where repairs are to be made.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 December 2007
Resolution: Rcvd class report confirming repairs to the Gyro compass
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 10 November 2004 Resolved
Repair to the satisfaction of attending class surveyor the hydraulic leaks on all of the cargo hold rams. SOLAS 74 amd I/II
Due 30 January 2005
Resolved 12 April 2005
Resolution: Hydraulic leaks have been fixed to the satisfaction of class and PSC boarding officers.
Lifesaving › Lifeboat › Hull
Issued 10 November 2004 Resolved
Repair to the satisfaction of class the patch on the port bow of the starboard lifeboat. SOLAS 74 amd I/II
Due 30 January 2005
Resolved 12 April 2005
Resolution: Repair to the patch located on the starboard lifeboat has been fixed to the satisfaction of class and PSC boarding officers.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 November 2004 Resolved
Replace expired medicines in the vessel's hospital. ILO 147
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 October 2005
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 November 2004 Resolved
Repair to the satisfaction of class the oily water seperator skin valve. While testing the OWS a fast leak was found on the OWS valve stem. SOLAS 74 amd I/II
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2004
Resolution: Class verified repairs had been made in ABS class report: PO563726
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 20 February 2004 Resolved
Hydrolic leak on pistons on cargo hold #4. Cargo hold (Forward port side), #3 cargo hold (Forward STBD), #2 cargo hold (Port Aft). Class to attest to proper repairs. Condition of class issued to overhaul cylinders by 20 May 2004. LEGACY COMPONENT DESC: Hydrolic Piston
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 10 November 2004
Resolution: Cleared, and then re-issued deficiency to be addressed prior to departure from port.
Deck/Cargo › Mooring/Anchoring
Issued 20 February 2004 Resolved
Observed hydrolic leak on windlass. Hydrolic fluid heating tank in baotswains hole. Hydrolic fluid creates slipping hazards IWO ladder. Class tto attest to proper repairs. LEGACY COMPONENT DESC: Winch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 26 February 2004
Resolution: Received class report attesting to the proper repair of heating tank.
Stability › Watertight Integrity
Issued 20 February 2004 Resolved
Boatswain hole hatch door not watertight. Door will not seal properly, and 2nd officer describe half inch of water on deck in baotswain hole after storm. Class to attest to watertight integrity of boatswains hole. LEGACY COMPONENT DESC: Hatch Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2004
Resolved 26 February 2004
Resolution: Received class report attesting to the proper repair of hole hatch door.
Fire Fighting › Fire Main
Issued 20 February 2004 Resolved
Observed water leak from fire main flange IWO of cargo hold #4 on STBD side. Class to attest to proper repairs of fire main. LEGACY COMPONENT DESC: Valves
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 26 February 2004
Resolution: Received class report attesting to the proper repair of fire main flange.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 20 February 2004 Resolved
Observed fire box equipment missing from various locations on deck. Fire hose wrench missing from box located outside deck house on port side. Fire box #7 IWO cargo hold #4 has damaged door & is held closed by rope. Fire box on main deck outside deck house on STBD side missing door & all equip. LEGACY COMPONENT DESC: Fire Box
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 26 February 2004
Resolution: Received class report attesting to the proper repair of fire stations and found stations properly equipped.
Fire Fighting › Fire Main
Issued 20 February 2004 Resolved
Discharge pipe on fire main pump has a soft patch. Remove/repair to the satisfaction of class society. LEGACY COMPONENT DESC: Discharge Pipe
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 February 2004
Resolved 26 February 2004
Resolution: Received class report attesting to the proper repair of discharge pipe.
Engineering › Feedwater/Condensate Water System
Issued 20 February 2004 Resolved
Provision cooling pump discharge pipe hole are leaking. Pump located on lower level of E.R. stbd side. Remove/repair to the satisfaction of class surveyor. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 26 February 2004
Resolution: Received class report attesting to the proper repair of refrigeration cooling pump discharge line.
Engineering › Feedwater/Condensate Water System
Issued 20 February 2004 Resolved
Supply pipe to fresh water heater located over the fresh water heater control panel found fractured & weaping. Renew/repair to the satisfaction of class society surveyor. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 26 February 2004
Resolution: Received class report attesting to the proper repair of supply pipe.
Engineering › Freshwater Generation System
Issued 20 February 2004 Resolved
Supply pipe to fresh water generator found with 2 temp. repairs (doublers). Renew/repair to the satisfaction of class surveyor. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 26 February 2004
Resolution: Received class report attesting to the proper repair of supply pipe.
Engineering › Fuel Oil Service System
Issued 20 February 2004 Resolved
Steam supply by-pass for f/o automatic backwash pipe wasted & leaking. Piping located "C" platform of E/R stbd side inboard of catwalk. Renew/repair to the satisfaction of class surveyor. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 26 February 2004
Resolution: Received class report attesting to the proper repair of steam supply by-pass line.
Engineering › Compressed Air System (start air)
Issued 20 February 2004 Resolved
S/W discharge pipe on air compressor cooler found with temp repairs (lag welds). Class surveyor to recomend repairs. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 26 February 2004
Resolution: Received class report attesting to the proper repair of salt water discharge pipe.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 20 February 2004 Resolved
#3 SSDG L/O cooler has temp repair on aft side of cooler. Class to recommend repairs. LEGACY COMPONENT DESC: Lube oil cooler
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2004
Resolved 26 February 2004
Resolution: Received class report attesting to the proper repair of cooler head.
Lifesaving › Launching Appliances › Davit
Issued 22 April 2002 Resolved
Provide properly operating lauching appliance on #2 lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2002
Resolved 25 April 2002
Lifesaving › Lifeboat › Exhaust Pipe
Issued 22 April 2002 Resolved
provide means to prevent the entry of sea water into the exhaust pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2002
Resolved 25 April 2002
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 22 April 2002 Resolved
Provide proper lifeboat launching instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2002
Resolved 25 April 2002
Fire Fighting › Fire Hoses › Connections
Issued 22 April 2002 Resolved
provide spanner wrenches at fire hose stations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2002
Resolved 25 April 2002
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 April 2002 Resolved
Provide light list for transited areas.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 April 2002
Resolved 25 April 2002
Navigation
Issued 7 July 1999 Resolved
Provide current/corrected Coast Pilot #7 prior to departure from this port.3 3 CFR 164.
Condition: Unknown
Due 19 July 1999
Resolved 7 July 1999
Engineering
Issued 7 July 1999 Resolved
Hydro test all fuel oil transfer lines prior to bunkering in U. S. waters. 33 CFR 156.
Condition: Unknown
Due 2 November 1999
Resolved 2 November 1999
Fire Fighting
Issued 7 July 1999 Resolved
Remove hold back devices from all deck house fire doors prior to next U.S. port after sailing foreign. SOLAS 74 amd II-2/47.
Condition: Unknown
Due 19 July 1999
Resolved 7 July 1999
Electrical
Issued 16 June 1998 Resolved
PROVE PROPER OPERATION OF OWS ALARM AND STOPPING DEVICE. OVERBOARD VALVE TOREMAIN CLOSED AND LOCKED UNTIL CORRECTED.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.