ODYSSEY III

ODYSSEY III is a 1995 passenger vessel (inspected). The Coast Guard has recorded 91 inspections since 1995, most recently in March 2026, along with 135 deficiencies and 13 casualty investigations between 2007 and 2025.

Records from 1995 to 2026. Most recent: inspection, 18 March 2026.

Built
1995
Last inspected
18 March 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCT5769
421925
Flag
UNITED STATES
367055340
Maury page id
psix-421925

Inspections, by type

…with no type recorded22
Years with a record 31 calendar years (1995–2026)
The 91 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)230.4 ft × 47.0 ft × 10.7 ft
Registered tonnagegross 94 / net 83
ITC dimensions (L × B × D)230.4 ft × 47.0 ft × 10.7 ft
ITC tonnagegross 1,669 / net 504
BuilderSERVICE MARINE INDUSTRIES INC · MORGAN CITY, LA, UNITED STATES · built 1995
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWASHINGTON, DC
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 16 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
1669 - Convention (Subpart B), Gross Ton
83 - Regulatory (Subpart C or D), Net Ton
504 - Convention (Subpart B), Net Ton
1365 - Displacement, Ton
533 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCT5769MMSI 367055340 · active · compulsorily equipped · granted 8 May 2025, expires 24 July 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 91

18 March 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8327854
21 April 2025 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8118650
27 March 2025 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8108967
27 January 2025 Deficiency Check · Examination of Repairs
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8070535
31 May 2024 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7936980
15 May 2024 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7913473
22 April 2024 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7916094
10 January 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7842802
15 November 2023 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7825307
3 November 2023 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7819903
15 May 2023 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7688953
16 April 2023 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7669621
16 April 2023 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7669905
1 March 2023 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7652604
4 February 2022 Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7390770
29 August 2021 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7311141
28 August 2021 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7300971
26 August 2021 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7297238
25 May 2021 Deficiency Check · Annual Inspection · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7212091
17 June 2020 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6998022
1 May 2019 MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6724133
9 January 2019 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6607667
7 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6503643
12 June 2018 Damage Survey · Examination of Repairs
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6443947
12 April 2018 Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6390622
11 April 2018 Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6389304
8 April 2018 Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6389985
7 April 2018 Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6387617
14 March 2018 Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6373062
9 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6322278
21 July 2017 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6269290
18 March 2017 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6107851
22 February 2017 Examination of Repairs
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6092185
13 February 2017 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6087688
2 February 2017 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6082206
24 February 2016 MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5822050
14 September 2015 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5718584
12 September 2015 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5732309
23 October 2014 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5011301
25 March 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4822594
22 February 2012 MTSA/ISPS Verification · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4237741
3 December 2011 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4203695
8 February 2011 MTSA Verification · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3942240
5 March 2010 Annual Inspection · DAPI Audit · Deficiency Check · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3691567
9 March 2009 DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3430502
28 January 2009 Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3401574
23 October 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3350143
20 October 2008 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3354995
20 June 2008 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3242309
12 June 2008 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3234688
7 February 2008 Annual Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3143947
27 October 2007 Examination of Repairs · Construction Oversight · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3088203
27 October 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3088854
8 June 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2955166
13 April 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2907169
12 April 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2906796
5 March 2007 MTSA Verification · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2874869
5 July 2006 Deficiency Check · In-Service Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2706906
20 April 2006 MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2629188
28 February 2006 Spot Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2602198
17 January 2006 Examination of Repairs
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2563548
26 September 2005 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2501073
25 July 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2440363
6 July 2005 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2416767
16 August 2004 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2167310
8 July 2004 MTSA Verification · Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2127284
22 June 2004 Security Plan Review - VSP
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2107109
25 February 2004 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2012891
30 December 2003 Security Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1971652
16 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1971019
29 April 2002 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1610323
31 July 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1441901
31 March 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 99768
19 June 2000 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1435094
13 July 1999 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1461990
26 May 1999 Excursion Permit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 803371
14 May 1999 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 797256
11 March 1999 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 805451
9 October 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 803016
14 July 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1129861
7 July 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 794020
25 September 1997 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1114215
29 April 1997 Re-Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1411481
27 January 1997 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1101206
31 October 1996 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1383360
27 May 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1085491
20 May 1996 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1421136
6 March 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 169239
6 March 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 232209
7 October 1995 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1449901
27 May 1995 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409392

Deficiency record · 135

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2026 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition, safe electrical condition, and fit for the service for which they are intended. Port engine room heater fan was not mounted and was hanging by its wires. 46CFR176-25-15
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 April 2026
Resolution: Received photo of the heater being removed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2026 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition, safe electrical condition, and fit for the service for which they are intended. The #2 steering pump control box was missing a reset button which left an open hole into the box. 46CFR176-25-15
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 April 2026
Resolution: Received photo of the steering controller having a blank installed. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 April 2024 Resolved
Permission for repair or alteration. (a)Repairs or alterations to the hull, machinery, or equipment that effect safety of the vessel must not be made without the approval of the cognizant Officer in Charge Marine Inspection (OCMI) except during emergency. Vessel involved in an allision with sister vessel during mooring evolution. Vessel is authorized temp repair of hole in way of the deck and covering board on the bow. Permanent repairs to be completed no later than 01 Feb 2025. 46CFR 115.700(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2025
Resolved 17 February 2025
Resolution: Verified with Sector NCR/Baltimore this deficiency should have been for the grey tank/bulkhead at frame 34 repair. Witnessed satisfactory repair and NDT.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 November 2023 Resolved
07105 - All doors shall be of a type which are capable of release from the control station and from a position at the door. The release mechanism shall be so designed that the door will automatically close. Four fire screen doors adjacent to the ventilation located forward and aft of the galley on the port and starboard sides would not close when released. The doors must remain closed unless actively in use. Signs must be posted on the doors stating they are to remain closed to prevent them from being propped open. 46 CFR 177.10-5(a) "Old T" 46 CFR 72.05(b)(9)(ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2023
Resolved 11 December 2023
Resolution: Attended vessel to inspect on set of fire doors, received video for the other 3.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 November 2023 Resolved
04103 - Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Two emergency lights in the engine room and one in the galley were inoperable. 46 CFR 120.432
Action required: 10 - Deficiency Rectified
Resolved 3 November 2023
Resolution: Corrected on the spot.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 April 2023 Resolved
46 CFR 120.420 All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel casualty resulted in loss of forward mast and associated lights. Repair as original prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2023
Resolution: O/O erected temporary mast for proper display of nav lights
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 16 April 2023 Resolved
46 CFR 121.404(a) All self-propelled vessels must be fitted with a FCC type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operating station. Repair as original prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2023
Resolution: vessel reinstalled a new radar for operations.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 March 2023 Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated. Areas in engine room in compressor room found missing A-60 insulation. 46CFR116.415(a)(2)(ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 16 March 2023
Resolution: Verified deficiency in person.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 March 2023 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Marine Inspector found dust accumulation in air handler room. 46CFR115.830(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 16 March 2023
Resolution: Verified deficiency in person.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 March 2023 Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Starboard side engine found to be leaking. 46CFR119.430(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 16 March 2023
Resolution: Verified deficiency in person.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 March 2023 Resolved
If individual wires, rather than cables, are used in systems greater than 50 volts, the wire must be in conduit. Marine inspector found the end wires in engine room tachometer junction box and bow prop space. 46CFR120.340(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 16 March 2023
Resolution: Verified deficiency in person.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 March 2023 Resolved
Fuel lines must be annealed tubing of copper, nickel-copper, or copper-nickel having a minimum wall thickness of 0.9 millimeters (0.35 inches) except that: When used, flexible hose must meet the requirements of § 56.60-25 in subchapter F of this chapter. Plastic pipe installations must be in accordance with IMO Resolution A.753(18) and IMO Resolution MSC.313(88). Shaft seal tubing on bow prop is not CG approved hose. 46CFR119.455(a)(1)(iii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 16 March 2023
Resolution: Verified deficiency in person.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 March 2023 Resolved
A door in a stairtower, stairway, and main vertical zone bulkhead must meet the following additional requirements: A door must be of the self-closing type capable of closing against a 3.5 list of the vessel. Fire Screen Door #6 located forward near the galley was unable to self-close. 46CFR116.435(c)(6)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 16 March 2023
Resolution: Verified deficiency in person.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 March 2023 Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of §§ 118.400 and 118.500 must be designed, constructed, installed, and maintained in a manner acceptable to the Commandant. Chiller room heat detector was found to be inoperable. 46CFR118.120(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 16 March 2023
Resolution: Verified deficiency in person.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 1 March 2023 Resolved
Fire dampers must be capable of manual operation from outside the space served, be fitted with an indicator showing whether the damper is open or closed, and be marked with red letters of at least 12.7 millimeters (0.5 inches) in height stating “VENTILATION FIRE DAMPER". All vent fire dampers were found not marked. 46CFR116.610(g)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 16 March 2023
Resolution: Verified deficiency in person.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 March 2023 Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, that provide strength and support equivalent to fixed rails. Deck rails must include a top rail with the minimum height required by this section, and lower courses or equivalent protection as required by this section. Marine inspector found that the handrail wire on the Port forward handrail in way of the rescuer area was missing. 46CFR116.900(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 16 March 2023
Resolution: Verified deficiency in person.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 March 2023 Resolved
A hatch cover must, be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Chain locker hatch line that connects hatch to boat was found missing. 46CFR116.160(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 16 March 2023
Resolution: Verified deficiency in person.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 February 2022 Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated. Aft bulkhead in the engine room has multiple areas that need to have A-60 boundary missing and need to be added.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 9 March 2022
Resolution: Reviewed photos, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2022 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Multiple dead end wires were found on two junction boxes on forward bulkhead of engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 March 2022
Resolution: reviewed photos, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 August 2021 Resolved
Each vessel that relies on electricity to power the vital systems, Communication systems, Navigation equipment and lights must be arranged so that the loads can be energized from two sources of electricity. Vessel has one generator that is inoperable. 46 CDR 120.310
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 September 2021
Resolution: Repairs completed and witnessing of satisfactory operation by Attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 May 2021 Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. The method of opening a means of escape must be obvious, rapid, and of adequate strength. Handles and securing devices must be permanently installed and not capable of being easily removed. The forward/starboard escape hatch from Chiller space can require more than one person to open and there is no locally available means of opening the escape hatch from the accommodation space side. 46 CFR 116.500(i)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 23 June 2021
Resolution: Spring tension was increased, making it easier for one person to open the emergency escape hatch. Means of opening hatch from accomodation space was fabricated and kept IVO of hatch.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 May 2021 Resolved
Each Class 1 door must have quick action closing device operative from both sides of the door. Watertight Class 1 door to Chiller Room misaligned, preventing watertight seal between knife edge and gasket. 46 CFR 177.13-1 (Old T) 46 CFR 170.270(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 23 June 2021
Resolution: Shipyard personnel fabricated new hinges and realigned watertight door, ensuring proper closure and watertight seal.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 May 2021 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Escape hatch from engine room not adequately marked on both sides. 46 CFR 122.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 23 June 2021
Resolution: Emergency Exit markings posted for escape hatch from engine room.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 May 2021 Resolved
The installation and location of portable fire extinguishers must be to the satisfaction of the cognizant [name withheld] fire extinguisher located in Chiller Room not properly mounted. 46 CFR 118.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 23 June 2021
Resolution: Portable fire extinguisher is not properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 May 2021 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operations. All remote fuel shutoff station markings are deteriorated and illegible. 46 CFR 122.608
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 23 June 2021
Resolution: Markings renewed for all emergency fuel shutoff locations.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 May 2021 Resolved
For each watertight door, an indicator must be installed in the operation station and show whether the door is open or closed. Limit switch used on Chiller Room watertight door not adequately installed to accurately show door status at operating station. 46 CFR 177.13-1 (Old T) 46 CFR 170.270(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 23 June 2021
Resolution: Limit switch indicating door open/close status realigned and properly functioning.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 May 2021 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. There is inadequate emergency lighting in Chiller Room. 46 CFR 120.432(a)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 23 June 2021
Resolution: Additional emergency lighting installed in Chiller Room providing adequate emergency lighting to illuminate exit pathways.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 25 May 2021 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Overhead hot water potable water pipe is leaking. 46 CFR 115.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 23 June 2021
Resolution: Leaking section of pipe cropped and renewed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 May 2021 Resolved
The bottoms of doors in "A" Class bulkheads may be undercut not to exceed 1/2 inch above the door sill or top of approved deck coverings. Submit repair proposal to address fire doors #5 and #7, the bottoms of which are undercut in excess of 1/2 inch above the door sill. 46 CFR 177.10-5(a) 46 CFR 72.05-25(b)(6)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 12 August 2021
Resolution: Pictures received showing adequate repair to fire doors #5 and #7 to reduce the undercut less than 1/2 inch above the sill.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 August 2018 Resolved
Vsl is broadcasting: Invalid IMO # and incorrect Name.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 September 2018
Resolved 17 October 2018
Resolution: Vessel met all requirements for AIS broadcasting.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 14 March 2018 Resolved
Fire Pump seal repacked due to excessive leaking.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2018
Resolved 16 March 2018
Resolution: Vessel owner provided proof of new seal packing being installed in Fire Pump (Service Tech report and video of fire pump operating w/no leaks), ALL SAT.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 14 March 2018 Resolved
Prove proper operation of Fire screen doors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 29 March 2018
Resolution: Verified proper operation of ALL fire screen doors, ALL SAT.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 9 December 2017 Resolved
Vessels primary Generator shut down during Underway operation due to E-Stop grounding out; Electrical equipment and installations must be suitable for the roll, pitch and vibration of the vessel underway as directed by 46 CFR 120.220. Vessel restricted from carrying passengers until electrical cables effected by vibration damage is repaired as original and operation test is performed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2017
Resolved 9 December 2017
Resolution: Received technicians report attesting to results of trouble shooting, found chaffed wire on wiring harness, repaired and relocated harness. Performed operational test, all sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 18 March 2017 Resolved
FCC Station License has different call sign than Radio Safety Certificate and Bridge-to-Bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Witnessed matching FCC station license and Radio safety cert
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 March 2017 Resolved
Batteries were expired. Replace batteries with manufacturer's required batteries.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspected new batteries in lifebuoys
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 18 March 2017 Resolved
Replace handle on starboard fire door in beverage refreshment area. Provide proof of operation.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspected installed handle.
Fire Fighting › Structural - B Class Divisions › Machinery Spaces
Issued 18 March 2017 Resolved
Remove 5 gallon bucket of hydraulic oil from steering compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Witnessed that hydraulic oil was removed from compartment.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 18 March 2017 Resolved
IWO engine room, overdue for service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspected serviced portable CO2
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 18 March 2017 Resolved
In steering compartment overdue for servicing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspected portable dry chem in steering compartment.
Navigation › Piloting/Steering › Maneuverability Rating
Issued 18 March 2017 Resolved
Hydraulic reservoir for manual steering is empty, refill as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspected hydraulic reservoir was full.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 18 March 2017 Resolved
Aft mast pump control missing cover; replace
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Witness installation of cover.
Fire Fighting › Combustible Materials › Insulation
Issued 18 March 2017 Resolved
Re-attach lagging on starboard main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspected properly attached exhaust lagging on stbd main eng.
Electrical › Electric Supply System (service) › Battery Charger
Issued 18 March 2017 Resolved
Engine room battery charger feed line is taped; make proper connection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspected wire on batter, found that tape was only installed as chaffing protection.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 March 2017 Resolved
Galley circuit breaker panels must be blanked off where there are no switches.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspected breaker panels for properly installed blanks.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 18 March 2017 Resolved
Clean bilges and engine room deck plates of excessive oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspected eng room bilge and deck plates for cleanliness.
Fire Fighting › Grease Extraction Hood › General
Issued 18 March 2017 Resolved
Clean galley hood system of excessive grease.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspected galley hood for cleanliness
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 18 March 2017 Resolved
Replace galley fire dampner handle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Witnessed properly installed galley fire dampner handles.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 March 2017 Resolved
Properly connect hot box stove in galley in junction box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspected properly connected hot box stove in galley with junction box installed.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 18 March 2017 Resolved
Provide documentation of current fire panel servicing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspected sevice report for fire panel.
Engineering › Steering Gear System › Rudder
Issued 18 March 2017 Resolved
Grease/re-pack rudder post.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspected greased rudder post.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 March 2017 Resolved
Ensure proper operation of exit signs
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Witnessed properly operating exit signs.
Engineering › Generator (propulsion-electric) › Circuit Board
Issued 18 March 2017 Resolved
No. 2 SSDG control panel at generator had excessive smoke. Provide proof of proper operation. Provide tech report.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2017
Resolved 12 June 2017
Resolution: Received service report attesting to satisfactory operation of No.2 SSDDG
Engineering › Fuel Oil Service System › Filter
Issued 18 March 2017 Resolved
Clean filter bowl in bow thruster compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 12 June 2017
Resolution: Inspcted clean fuel bown/ water seaperator in bow thruster compartment.
Construction/Loadline › Hull › Bottom Plating
Issued 2 February 2017 Resolved
Submit written repair proposal to OCMI prior to beginning permanent repairs. All repairs must be completed to the satisfaction of Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2017
Resolved 3 March 2017
Resolution: Ultrasonic Testing conducted in vicinity of puncture. 10' X 5' area cropped and renewed with 3/8" insert. Fit-up, backgouge, and final weld test (vacuum box) witnessed by CGMI.
Construction/Loadline › Hull › Bottom Plating
Issued 2 February 2017 Resolved
Submit gauging report of entire hull to local OCMI, to the satisfaction of Coast Guard Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2017
Resolved 27 February 2017
Resolution: Received Ultrasonic Thickness Testing Report from Colonna's Shipyard, Inc. conducted on 24Feb2017 with 184 shots. Zero wastage readings above allowable tollerances present on report.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 February 2016 Resolved
Port forward life ring float light holder broken, Renew
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 29 February 2016
Resolution: Float light holder replaced.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 February 2016 Resolved
Original COD not onboard. Provide and properly display.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 8 March 2016
Resolution: Current COD on board.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 24 February 2016 Resolved
Fire doors, Portside amidships aft pair not closing properly. Galley fire door No. 5 not closing properly. Adjust and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 24 February 2016
Resolution: Prior to departure examined adjusted doors, SAT.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 February 2016 Resolved
All appliances in galley sitting on movable dollies. Properly secure in appropriate positions under the Gaylord Hood.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 21 March 2016
Resolution: All appliances properly secured.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 24 February 2016 Resolved
Provide service report for Heat/Smoke detectors and testing of manual fire pulls.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 29 February 2016
Resolution: Service report received and verified.
Electrical › Electric Supply System (service) › Cable
Issued 24 February 2016 Resolved
Replace battery cable for Stbd engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 26 February 2016
Resolution: Crew replaced cable and terminal connection.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 24 February 2016 Resolved
Replace SFP in way od STBD bulkhead and Emergency egress Port side in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 29 February 2016
Resolution: SFP replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 February 2016 Resolved
Replace port generator lagging.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 29 February 2016
Resolution: Lagging replaced.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 24 February 2016 Resolved
Stbd fuel oil shutoff cable has loose conduit binding shut-off operation. Remove conduit and re-route cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 29 February 2016
Resolution: Fuel oil shutoff cable cover removed and rerouted.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 24 February 2016 Resolved
Double clamp missing on Port main engine, Replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 29 February 2016
Resolution: Double clamps installed.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 24 February 2016 Resolved
Expansion tank for Port generator has wasted hose, replace and double clamp.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 29 February 2016
Resolution: Hose to expansion tank replaced.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 24 February 2016 Resolved
Engine room has gear adrift and has areas coated with oil. Clean and maintain engine room to prevent fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 29 February 2016
Resolution: Engine room gear adrift and excessive oil removed.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 25 March 2014 Resolved
Main SSDG is INOP. Vessel is allowed to operate on secondary generator, however vessel cannot transit bridges and must maintain comms schedule with SECBALT command center when operating.
Due 1 April 2014
Resolved 26 March 2014
Resolution: Verified generator was operating and carrying ship''''s electrical load. Received service report from Caterpillar technician, indicating adjustment of overspeed trip setting and replacement of shorted fuel shutoff solenoid.
Engineering › Steering Gear System › Rudder Bearing
Issued 3 February 2012 Resolved
Port side rudder post leaking excessive water into the lazarette. Provide repair proposal to the CG [name withheld] for review prior to conducting repairs. Vessel is restricted from carrying passengers until repairs have been conducted and the vessel has been taken back underway with CG marine inspector for review.
Due 14 April 2012
Resolved 15 May 2012
Resolution: Repairs effected, rudder post is still weeping minimal amounts of water, not excessively as in the past, vessel owners plan on pulling the rudder at the next hull exam. Vessel representative was counseled to monitor the space at interval.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 8 February 2011 Resolved
Repair damaged wind shield wiper system or remove.
Action required: 705 - Other - as specified
Due 8 February 2011
Resolved 8 February 2011
Resolution: Wiper was never used and removed prior to departure from vessel.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 8 February 2011 Resolved
Clean out sprinkler pressure vessel and make all three pressure vessels available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2011
Resolved 11 February 2011
Resolution: All 03 pressure vessels were inspected with no deficiencies noted.
Construction/Loadline › Hull › Bottom Plating
Issued 8 February 2011 Resolved
STBD side galley void space between frames 75 and 80, hull plating above generator keel cooler wasted/holed. Provide gauging report for area above all keel coolers showing plate thickness above coolers and hull plate adjacent to keel coolers. Provide temp and permanent repair proposals to OCMI and do not operate with passengers for hire until proposals are received, reviewed and aproved by the.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2011
Resolved 11 February 2011
Resolution: Temporary repair was inspected and approved, gauging results were received and approved along with the permanent repair proposal.
Engineering › Pressure Vessel › Piping
Issued 5 March 2010 Resolved
#1 hot water tank leaking. Could not determine cause. Vsl rep to submit repair proposal.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 1 April 2010
Resolution: Leaking hot water tank removed, piping capped. As the vessel currently has 2 other functioning hot water heaters, this hot water heater will not be replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 February 2008 Resolved
Replace or install guard over roatating fan belt on Port main engine.
Action required: 705 - Other - as specified
Due 21 February 2008
Resolved 7 February 2008
Resolution: Corrected on scene prior to departure from vessel.
Construction/Loadline › Penetrations › Gasket
Issued 7 February 2008 Resolved
Replace gasket on engine room watertight door.
Action required: 705 - Other - as specified
Due 21 February 2008
Resolved 5 March 2008
Resolution: Verified replacement of gasket material.
Construction/Loadline › Penetrations › Gasket
Issued 7 February 2008 Resolved
Replace gaskets on all hatch covers leading to bilge in the galley.
Action required: 705 - Other - as specified
Due 21 February 2008
Resolved 5 March 2008
Resolution: Verified replacement of gasket material.
Fire Fighting › Grease Extraction Hood › General
Issued 7 February 2008 Resolved
Remove and clean behind galley range hood.
Action required: 705 - Other - as specified
Due 21 February 2008
Resolved 5 March 2008
Resolution: Verified galley hood was properly cleaned.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 7 February 2008 Resolved
Submit proposal to address standing water in bilge throughout the vessel. Noted mold and excessive scaling in all areas.
Action required: 705 - Other - as specified
Due 21 February 2008
Resolved 5 March 2008
Resolution: Received written proposal from O/Op.
Electrical › Electrical Distribution System (service) › Switch
Issued 7 February 2008 Resolved
Mount switch in pumproom to keep it from stressing out the electrical wires.
Action required: 705 - Other - as specified
Due 21 February 2008
Resolved 5 March 2008
Resolution: Verified switch was properly mounted.
Construction/Loadline › Hull › Hull Plating
Issued 27 October 2007 Resolved
Vessel has a through crack, approx. 54in. from the main deck leading down approx. 31.5in above the waterline, in way of the bow area leading into the chain locker compromising the vessel's watertight and structural integrity. The main deck is also buckled in an area approx. 185in. from the centerline leading stbd. and approx. 23in from fore to aft.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 23 November 2007
Resolution: Vessel has completed all welding processes in relation to initial damage survey. All applicable welds were hydrostatically tested. All welds tested sat. Powerpoint presentation of the final welding process is in the MISLE activity.
Construction/Loadline › Penetrations › Gasket
Issued 27 October 2007 Resolved
Upon removal of the deck covering there was found to be over 30 gallons of standing water in the chain locker space (forward). Prove weathertight integrity of this space to the satisfaction of the attending USCG marine inspector prior to operation in accordance with 46 CFR 116.1160.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2007
Resolution: Vessel has completed all welding processes in relation to initial damage survey. All applicable welds were hydrostatically tested. All welds tested sat. Powerpoint presentation of the final welding process is in the MISLE activity.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 27 October 2007 Resolved
The propulsion control from the port wing station failed upon mooring the vessel at berth. Vessel is to prove proper operation of the port wing propulsion controls to the satisfaction of the attending USCG Marine Inspector, in accordance with 46 CFR 115.840, prior to operation.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2007
Resolution: Attended vessel, conducted operational test of all conning stations (port and stbd bridge wings and pilot house), tested sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 5 March 2007 Resolved
Have fire service company attest to the proper installation, type and labeling of the horizontally installed CO2 bottles in accordance with NFPA 12/Approved KIDDE installation manual.
Action required: 705 - Other - as specified
Due 19 March 2007
Resolved 21 March 2007
Resolution: O/Op sent fax showing the proper servicing and labeling of the 7 75lbs CO2 bottles.
Construction/Loadline › Hull › Weld
Issued 5 July 2006 Resolved
Port generator exhaust leaking through fractured weld at hull of vessel. Repair as original using certified welder. De-ballast vessel to bring effected area approx. 18" above the waterline. Maintain de-ballast state at all times while passengers are on board. Repairs to be completed to the satisfaction of a USCG marine inspector prior to 8 Jul 06.
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 6 July 2006
Resolution: Attended vessel to inspect repairs to fractured weld at waterline on hull. Witnessed Dye-Pen test. Cleared deficiency listed above.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 1 March 2006 Resolved
33U.S.C.1321(j)(D)(ii)-The NTVRP does not discuss the qualified individual's responsibilities for immediate communication with the NRC and notification of the oil spill removal organization.
Due 1 April 2006
Resolved 15 January 2009
Resolution: NTVRP plan #03697 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 July 2004 Resolved
Emergency lighting fixture in front of generator switchboard inoperable.
Due 8 August 2004
Resolved 15 July 2004
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 8 July 2004 Resolved
Pilot house console lube oil pressure guage for starboard main engine inoperable.
Due 8 August 2004
Resolved 15 July 2004
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 April 2002 Resolved
REPAIR FIRE DOOR STARBOARD SIDE
Due 1 May 2002
Resolved 1 May 2002
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 April 2002 Resolved
RENEW EMERGENCY EXIT LIGHTS MAIN DECK FOWARD.
Due 1 May 2002
Resolved 1 May 2002
Accommodation/Occupational Safety
Issued 31 July 2001 Resolved
FIX BROKEN GLASS ON STERN DOOR (STBD) SIDE OF VESSEL.
Condition: Unknown
Due 12 September 2001
Resolved 13 September 2001
Electrical
Issued 31 July 2001 Resolved
RENEW EMERGENCY LIGHTING INCLUDING EXIT SIGN LIGHTS THROUGHOUT VESSEL (SIX TOTAL).
Condition: Unknown
Due 12 September 2001
Resolved 13 September 2001
Engineering
Issued 31 July 2001 Resolved
TIGHTEN PORT SHAFT PACKING.
Condition: Unknown
Due 12 September 2001
Resolved 13 September 2001
Engineering
Issued 31 July 2001 Resolved
RENEW WATER INTAKE HOSE TO BOW THRUSTER.
Condition: Unknown
Due 12 September 2001
Resolved 13 September 2001
Navigation
Issued 19 June 2000 Resolved
REPAIR HYDRAULIC LEAK ON STEERING PUMP.
Condition: Unknown
Due 19 July 2000
Resolved 5 September 2000
Accommodation/Occupational Safety
Issued 19 June 2000 Resolved
LABEL "EMERGENCY ESCAPE" ON LOCKER ROOM DOORS.
Condition: Unknown
Due 19 July 2000
Resolved 5 September 2000
Navigation
Issued 19 June 2000 Resolved
TIGHTEN PORT RUDDER PACKING.
Condition: Unknown
Due 19 July 2000
Resolved 5 September 2000
Documentation
Issued 14 May 1999 Resolved
PROVIDE FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Engineering
Issued 14 May 1999 Resolved
ADDRESS OIL LEAK IN BOW THRUSTER.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Construction/Loadline
Issued 14 May 1999 Resolved
SUBMIT PROPOSAL TO REPAIR FRACTURED WELD/GUSSET IN LAZARETTE.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Fire Fighting
Issued 14 May 1999 Resolved
PROVIDE LABELS FOR FIRE DOOR RELEASES.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Fire Fighting
Issued 9 October 1998 Resolved
ENSURE CYLINDERS FOR CO2 FIXED FIRE FIGHTING SYSTEM ARE INSTALLED NOT MORE THAN 80 DEGREES FROM THE VERTICAL.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Navigation
Issued 14 July 1998 Resolved
PROVIDE CHART OF OPERATING AREA.
Condition: Unknown
Due 14 August 1998
Resolved 24 July 1998
Electrical
Issued 14 July 1998 Resolved
ENSURE ALL EMERGENCY LIGHTING OPERATES.
Condition: Unknown
Due 21 July 1998
Resolved 24 July 1998
Fire Fighting
Issued 14 July 1998 Resolved
ENSURE ALL VENT CLOSURES OPERATE PROPERLY.
Condition: Unknown
Due 21 July 1998
Resolved 24 July 1998
Construction/Loadline
Issued 14 July 1998 Resolved
PROVIDE GASKET FOR GALLEY ESCAPE SCUTTLE.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Navigation
Issued 14 July 1998 Resolved
PROVIDE WRITTEN PLAN TO ADDRESS LEAKAGE AT RUDDER POSTS PACKING.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Lifesaving
Issued 14 July 1998 Resolved
PROVIDE LISTING OF ALL EMPLOYEES ENROLLED IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 21 July 1998
Resolved 24 July 1998
Engineering
Issued 14 July 1998 Resolved
ADDRESS LEAK IN FUEL LINE FOR BOWTHRUSTER.
Condition: Unknown
Due 15 July 1998
Resolved 24 July 1998
Engineering
Issued 14 July 1998 Resolved
PROVIDE THREADED CAPS FOR 2 VALVES IN FWD FUEL TANK, 1 VALVE IN PORT FUEL TANK, AND 2 VALVES IN STBD FUEL TANK.
Condition: Unknown
Due 21 July 1998
Resolved 24 July 1998
Engineering
Issued 14 July 1998 Resolved
CONDUCT INTERNAL EXAM OF AIR RECEIVERS.
Condition: Unknown
Due 14 August 1998
Resolved 24 July 1998
Electrical
Issued 7 July 1998 Resolved
REPLACE MAIN GENERATOR AND PROVE PROPER OPERATION.
Condition: Unknown
Due 26 July 1998
Resolved 5 August 1998
Electrical
Issued 7 July 1998 Resolved
CONDUCT PERMANENT REPAIRS TO ENGINE ROOM LIGHTING WIRING.
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998
Electrical
Issued 7 July 1998 Resolved
REPAIR #2 GENERATOR.
Condition: Unknown
Due 15 July 1998
Resolved 24 July 1998
Accommodation/Occupational Safety
Issued 7 July 1998 Resolved
REPAIR DOOR LATCH FOR DOOR IN PORT PARTITION BETWEEN AFT DINING ROOM AND AMIDSHIPS DINING ROOM.
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998
Engineering
Issued 29 April 1997 Resolved
Repair oil leaks in port and starboard MDE's gear boxes.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Navigation
Issued 29 April 1997 Resolved
Provide current tide tables.
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Electrical
Issued 29 April 1997 Resolved
Conduct satisfactory test of emergency lighting system.
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Lifesaving
Issued 29 April 1997 Resolved
Provide proper retro-reflective tape on ring buoys._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Accommodation/Occupational Safety
Issued 29 April 1997 Resolved
Clean grill hood and vents prior to carrying passengers.
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Accommodation/Occupational Safety
Issued 29 April 1997 Resolved
Provide control knob for grill.
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Engineering
Issued 29 April 1997 Resolved
Provide proper markings for emergency fuel shut-offs.
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Electrical
Issued 29 April 1997 Resolved
Tighten and clean battery connections as necessary.
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Engineering
Issued 29 April 1997 Resolved
Provide chaffing protection for bow thruster fuel line.
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Lifesaving
Issued 29 April 1997 Resolved
Remove oil from bow thruster room and engine room bilges.
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Electrical
Issued 29 April 1997 Resolved
Conduct operational test of port generator.
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Fire Fighting
Issued 29 April 1997 Resolved
Adjust fire doors as necessary.
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Engineering
Issued 29 April 1997 Resolved
Repair leaking valve for bow thruster fuel line.
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Electrical
Issued 29 April 1997 Resolved
Remove ground from electrical system.
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Accommodation/Occupational Safety
Issued 29 April 1997 Resolved
Provide means to prevent blocking of emergency escape hatches for below deck spaces.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Engineering
Issued 29 April 1997 Resolved
Tighten starboard shaft packing.
Condition: Unknown
Due 12 May 1997
Resolved 29 May 1997
Fire Fighting
Issued 20 May 1996 Resolved
The intake to the fire pump is located too close to the propellers which cause the pump to become airbound when underway. The owner has been given until the vessel's next drydock to relocate the intake._x001C_
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Navigation
Issued 20 May 1996 Resolved
The required mayday placard near the VHF radio is missing._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 24 June 1996
Electrical
Issued 20 May 1996 Resolved
The electrical panel marked "M1" in the engine room had blank spaces with no switch or cover over the spaces._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 24 June 1996
Electrical
Issued 20 May 1996 Resolved
The batteries for the vessel had wing nut connectors._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 24 June 1996
Engineering
Issued 20 May 1996 Resolved
The handle on the port side emergency fuel shut off valve is broken._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 May 1996
Resolved 24 June 1996

Casualty record · 13

12 April 2007Routine · role: Involved in a Marine Casualty · activity 2906796
27 October 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 3088854
6 June 2010Routine · role: Involved in a Marine Casualty · at 14TH STREET TRAIN BRIDGE (UPPER POTOMAC) · activity 3763219
3 December 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4203695
9 March 2012Routine · role: Involved in a Marine Casualty · activity 4262487
5 January 2013Routine · role: Involved in a Marine Casualty · activity 4512083
6 July 2014Routine · role: Involved in a Marine Casualty · 1 injured · activity 4916627
14 September 2015Routine · role: Involved in a Marine Casualty · at 14TH STREET BRIDGE COMPLEX · activity 5718584
21 July 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6269290
28 August 2021Routine · role: Involved in a Marine Casualty · activity 7300971
16 April 2023Routine · role: Involved in a Marine Casualty · at 14TH STREET BRIDGE COMPLEX · activity 7669621
15 May 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7913473
27 March 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8108967
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.