Records from 2016 to 2021. Most recent: inspection, 15 August 2021.
Documentation record
Registered dimensions (L × B × D)129.0 ft × 36.0 ft × 11.4 ft
Registered tonnagegross 197 / net 134
ITC dimensions (L × B × D)129.0 ft × 36.0 ft × 11.4 ft
ITC tonnagegross 442 / net 132
BuilderSERVICE MARINE INDUSTRIES INC · MORGAN CITY, LA, UNITED STATES · built 1995
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portEASTPORT, ME
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 28 July 2026 · expires 31 August 2027
Service, as the file records itFishing Tender
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it197 - Regulatory (Subpart C or D), Gross Ton
442 - Convention (Subpart B), Gross Ton
134 - Regulatory (Subpart C or D), Net Ton
132 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Construction/Loadline › Structures › Deck Plating
Issued 28 April 2016
Resolved
Overhead on engine room vent tunnel has wasted frame and deck. Provide repair plan.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Areas replaced with good metal to the satisfaction of MI.
Deck/Cargo › Cargo Stowage › General
Issued 28 April 2016
Resolved
PV valves on methanol tanks have no placards or records of inspection. Drain valves are either plugged with bolts or corrroded. Provide servicable PV valves.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 10 May 2016
Resolution: Proper PV valves installed to the satisfaction of the MI.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 28 April 2016
Resolved
During inspection, full crew was not available for license checks or drills.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 9 May 2025
Lifesaving › Lifefloat › Serviceable
Issued 28 April 2016
Resolved
Lifefloats were found with cracks, delamination and faded paint/retro. One of the lights was not operating. Provide servicable life floats and lights.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: Proper repairs made to life floats.
Stability › Watertight Integrity › General
Issued 28 April 2016
Resolved
Watertight doors and hatches had improper gaskets or ill fitting ones. Check all doors and hatches and repair/replace gaskets as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: Gaskets replaced and hatches adjusted to the satisfaction of the MI.
Electrical › Electric Generation Source (service) › Generator
Issued 28 April 2016
Resolved
Windings on generators need cleaning. Clean as necessary to avoid fire.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: Generator windings cleaned.
Communications › Radio Communications › EPIRB
Issued 28 April 2016
Resolved
EPIRB needs new hydrostatic release. Current one is expired.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: Hydro release replaced with new one.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 28 April 2016
Resolved
Methanol pump on deck needs machinery guard.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Machinery guard put on pump.
Accommodation/Occupational Safety › Potable Water System › General
Issued 28 April 2016
Resolved
STBD potable water piping needs new handle on valve.
Due 28 May 2016
Resolved 12 May 2016
Resolution: New valves installed on both sides of ship.
Engineering › Compressed Air System (start air) › Compressor
Issued 28 April 2016
Resolved
Both air receivers have a MAWP of 200PSI. Gauges max out at 200. Replace with gauges 1.2 to 2.0 times the setting of the relief valve.
Due 28 May 2016
Resolved 12 May 2016
Resolution: New gauges installed with appropriate ranges.
Engineering › Pressure Vessel › Relief Valve
Issued 28 April 2016
Resolved
Repipe temperature relief valve on hot water heater to drain into bilge.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Relief valve piped to bilge.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 April 2016
Resolved
Stern light not working. Repair/replace as needed.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: Stern light repaired (bulb).
Construction/Loadline › Structures › Deck Plating
Issued 28 April 2016
Resolved
Cabinet for bridge rear controls has water damage/wastage and waterlogged plywood. Clean /descale for further inspection.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Area cleaned and descaled and rotted plywood cut away to the satisfaction of the MI.
Lifesaving › Lifebuoys › Serviceable
Issued 28 April 2016
Resolved
Starboard ring buoy has busted plug and is waterlogged. Repair/replace as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: Life buoy replaced.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 28 April 2016
Resolved
Captain could not provide current fire control plan. Provide for inspection
Due 28 May 2016
Resolved 12 May 2016
Resolution: Fire control plan mounted in galley.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 28 April 2016
Resolved
Paint locker currently has no fire protection. Check fire control plan to determine purpose of locker. Amend plan or provide appropriate protection. In addition, repair braces on locker.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Cabinet is not a paint locker. Crew labelled it appropriately. All paint removed.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 28 April 2016
Resolved
Bridge to Bridge Radio Telephony Certificate has expired. Provide current Cert.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Crew provided current cert.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 April 2016
Resolved
Wire runs on main deck for in way of sewage ESD are wasted away. Repair wire run supports
Due 28 May 2016
Resolved 17 June 2016
Resolution: Wire runs installed
Engineering › Fuel Oil Service System › Valve
Issued 28 April 2016
Resolved
Port main engine fuel supply valve has broken handle and stem. Replace as needed.
Due 28 May 2016
Resolved 12 May 2016
Resolution: New valve installed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 28 April 2016
Resolved
Methanol valve on main deck in containment on port side is frozen. Repair/replace as necessary.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 12 May 2016
Resolution: Valve repaired and functioning properly.
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 April 2016
Resolved
Captain could not provide records for drills and training. Additionally need records for EPIRB testing and lifesaving equipment maintenance.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 9 May 2025
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 28 April 2016
Resolved
Captain could not provide transfer procedures. Provide proper transfer procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 12 May 2016
Resolution: Transfer procedures provided and mounted in transfer area in ER.
Navigation › Piloting/Steering › Marine Charts
Issued 28 April 2016
Resolved
Required current navigation pubs and charts not available for inspection. Update charts and provide required nav pubs.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: All new charts and pubs provided.
Electrical › Electric Supply System (service) › Cable
Issued 28 April 2016
Resolved
Reposition ER exhaust fan shut off valve to accessible position outside vent.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Owner demonstrated proper operation of shut offs with out having to access panel box inside of vent enclosure. Additional shutoffs demonstrated in ER panel boards.
Fire Fighting › Firemans Outfit › Axe
Issued 12 April 2016
Resolved
Fire axe on bow has fallen off rotted handle. Replace as needed.
Due 28 May 2016
Resolved 12 May 2016
Resolution: New axe installed.