PAULINE T

PAULINE T is a 1995 fishing tender. The Coast Guard has recorded 32 inspections since 1995, most recently in August 2021, along with 50 deficiencies and 1 casualty investigation in 2021.

Records from 1995 to 2021. Most recent: inspection, 15 August 2021.

Built
1995
Last inspected
15 August 2021
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8792453 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCS2857
421926
Flag
UNITED STATES
366631000
Maury page id
psix-421926

Inspections, by type

…with no type recorded4
Years with a record 22 calendar years (1995–2021)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)129.0 ft × 36.0 ft × 11.4 ft
Registered tonnagegross 197 / net 134
ITC dimensions (L × B × D)129.0 ft × 36.0 ft × 11.4 ft
ITC tonnagegross 442 / net 132
BuilderSERVICE MARINE INDUSTRIES INC · MORGAN CITY, LA, UNITED STATES · built 1995
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portEASTPORT, ME
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 28 July 2026 · expires 31 August 2027
Service, as the file records itFishing Tender
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it197 - Regulatory (Subpart C or D), Gross Ton
442 - Convention (Subpart B), Gross Ton
134 - Regulatory (Subpart C or D), Net Ton
132 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ7036MMSI 366631000 · active · compulsorily equipped · granted 10 August 2017, expires 10 August 2027
WCS2857MMSI 367039650 · expired · voluntarily equipped · granted 24 April 2015, cancelled 12 July 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 32

15 August 2021 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7294278
20 April 2021 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7179079
18 June 2020 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7011471
9 June 2020 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6971734
12 March 2020 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6927947
1 August 2019 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6769309
2 February 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6105203
1 February 2017 MARPOL Annex VI Survey · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6207720
12 April 2016 Deficiency Check · COI Inspection · MTSA Verification · Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5851299
3 May 2012 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4295139
24 November 2010 Drydock Exam · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3896319
15 April 2009 Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3440749
29 July 2008 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3276558
17 July 2007 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2980611
24 April 2006 Cargo Tank Internal · Internal Structural Exam · COI Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2629550
16 August 2005 MTSA Verification · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2465207
14 July 2004 Cargo Tank Internal · Examination of Repairs · Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2132834
30 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1998596
16 July 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1847898
9 August 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1658862
16 March 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1637155
18 May 2001 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397646
29 September 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1053949
29 June 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373085
20 January 2000 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415299
17 May 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429137
8 June 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450164
16 May 1997 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442563
28 September 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2919
11 July 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466975
20 July 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878638
19 May 1995 Inclining Experiment · Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392208

Deficiency record · 50

Construction/Loadline › Structures › Deck Plating
Issued 28 April 2016 Resolved
Overhead on engine room vent tunnel has wasted frame and deck. Provide repair plan.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Areas replaced with good metal to the satisfaction of MI.
Deck/Cargo › Cargo Stowage › General
Issued 28 April 2016 Resolved
PV valves on methanol tanks have no placards or records of inspection. Drain valves are either plugged with bolts or corrroded. Provide servicable PV valves.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 10 May 2016
Resolution: Proper PV valves installed to the satisfaction of the MI.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 28 April 2016 Resolved
During inspection, full crew was not available for license checks or drills.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 9 May 2025
Lifesaving › Lifefloat › Serviceable
Issued 28 April 2016 Resolved
Lifefloats were found with cracks, delamination and faded paint/retro. One of the lights was not operating. Provide servicable life floats and lights.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: Proper repairs made to life floats.
Stability › Watertight Integrity › General
Issued 28 April 2016 Resolved
Watertight doors and hatches had improper gaskets or ill fitting ones. Check all doors and hatches and repair/replace gaskets as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: Gaskets replaced and hatches adjusted to the satisfaction of the MI.
Electrical › Electric Generation Source (service) › Generator
Issued 28 April 2016 Resolved
Windings on generators need cleaning. Clean as necessary to avoid fire.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: Generator windings cleaned.
Communications › Radio Communications › EPIRB
Issued 28 April 2016 Resolved
EPIRB needs new hydrostatic release. Current one is expired.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: Hydro release replaced with new one.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 28 April 2016 Resolved
Methanol pump on deck needs machinery guard.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Machinery guard put on pump.
Accommodation/Occupational Safety › Potable Water System › General
Issued 28 April 2016 Resolved
STBD potable water piping needs new handle on valve.
Due 28 May 2016
Resolved 12 May 2016
Resolution: New valves installed on both sides of ship.
Engineering › Compressed Air System (start air) › Compressor
Issued 28 April 2016 Resolved
Both air receivers have a MAWP of 200PSI. Gauges max out at 200. Replace with gauges 1.2 to 2.0 times the setting of the relief valve.
Due 28 May 2016
Resolved 12 May 2016
Resolution: New gauges installed with appropriate ranges.
Engineering › Pressure Vessel › Relief Valve
Issued 28 April 2016 Resolved
Repipe temperature relief valve on hot water heater to drain into bilge.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Relief valve piped to bilge.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 April 2016 Resolved
Stern light not working. Repair/replace as needed.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: Stern light repaired (bulb).
Construction/Loadline › Structures › Deck Plating
Issued 28 April 2016 Resolved
Cabinet for bridge rear controls has water damage/wastage and waterlogged plywood. Clean /descale for further inspection.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Area cleaned and descaled and rotted plywood cut away to the satisfaction of the MI.
Lifesaving › Lifebuoys › Serviceable
Issued 28 April 2016 Resolved
Starboard ring buoy has busted plug and is waterlogged. Repair/replace as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: Life buoy replaced.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 28 April 2016 Resolved
Captain could not provide current fire control plan. Provide for inspection
Due 28 May 2016
Resolved 12 May 2016
Resolution: Fire control plan mounted in galley.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 28 April 2016 Resolved
Paint locker currently has no fire protection. Check fire control plan to determine purpose of locker. Amend plan or provide appropriate protection. In addition, repair braces on locker.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Cabinet is not a paint locker. Crew labelled it appropriately. All paint removed.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 28 April 2016 Resolved
Bridge to Bridge Radio Telephony Certificate has expired. Provide current Cert.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Crew provided current cert.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 April 2016 Resolved
Wire runs on main deck for in way of sewage ESD are wasted away. Repair wire run supports
Due 28 May 2016
Resolved 17 June 2016
Resolution: Wire runs installed
Engineering › Fuel Oil Service System › Valve
Issued 28 April 2016 Resolved
Port main engine fuel supply valve has broken handle and stem. Replace as needed.
Due 28 May 2016
Resolved 12 May 2016
Resolution: New valve installed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 28 April 2016 Resolved
Methanol valve on main deck in containment on port side is frozen. Repair/replace as necessary.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 12 May 2016
Resolution: Valve repaired and functioning properly.
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 April 2016 Resolved
Captain could not provide records for drills and training. Additionally need records for EPIRB testing and lifesaving equipment maintenance.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 9 May 2025
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 28 April 2016 Resolved
Captain could not provide transfer procedures. Provide proper transfer procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 12 May 2016
Resolution: Transfer procedures provided and mounted in transfer area in ER.
Navigation › Piloting/Steering › Marine Charts
Issued 28 April 2016 Resolved
Required current navigation pubs and charts not available for inspection. Update charts and provide required nav pubs.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2016
Resolved 12 May 2016
Resolution: All new charts and pubs provided.
Electrical › Electric Supply System (service) › Cable
Issued 28 April 2016 Resolved
Reposition ER exhaust fan shut off valve to accessible position outside vent.
Due 28 May 2016
Resolved 12 May 2016
Resolution: Owner demonstrated proper operation of shut offs with out having to access panel box inside of vent enclosure. Additional shutoffs demonstrated in ER panel boards.
Fire Fighting › Firemans Outfit › Axe
Issued 12 April 2016 Resolved
Fire axe on bow has fallen off rotted handle. Replace as needed.
Due 28 May 2016
Resolved 12 May 2016
Resolution: New axe installed.
Lifesaving › Lifefloat › Float-free Link
Issued 17 July 2007 Resolved
Provide new life float weak links for both life floats (tags missing).
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 15 August 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 July 2007 Resolved
Repair exhaust leak on the port main engine, outboard exhaust riser.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 15 August 2007
Resolution: Renewed exhaust ''flex'' due to crack.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Governor
Issued 17 July 2007 Resolved
Repair oil leak on the stbd generator governor.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 15 August 2007
Resolution: Renewed governor gasket.
Fire Fighting › Fire Main › Condition
Issued 17 July 2007 Resolved
Crop and renew wasted fire monitor piping, horizontal run through the Engine Room Passageway. UT the pipe run and renew all wasted sections.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 15 August 2007
Resolution: Renewed monitor piping from ''elbow to elbow'' and elbows were inspected and found to be in good condition.
Navigation › Piloting/Steering › Marine Charts
Issued 24 April 2006 Resolved
Prove that navigation charts are current and corrected.
Due 27 May 2006
Resolved 26 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 April 2006 Resolved
Properly mount wires that are hanging between the pilot house and aft steering station.
Due 27 May 2006
Resolved 26 May 2006
Lifesaving › Lifefloat › Netting
Issued 24 April 2006 Resolved
Properly secure net on STBD side Lifefloat.
Due 27 May 2006
Resolved 26 May 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 April 2006 Resolved
Properly mark lifebuoy on the STBD 02 deck.
Due 27 May 2006
Resolved 26 May 2006
Documentation › Logs/Records › Garbage Recordkeeping
Issued 24 April 2006 Resolved
Provide proof of compliance with 33 CFR 151.63 Reciept shall be recorded for garbage that is discharge at a Port Reception Facility
Due 27 May 2006
Resolved 26 May 2006
Fire Fighting › Fire Main › Condition
Issued 24 April 2006 Resolved
Crop and renew fire monitor piping ( horizontal run)
Due 27 May 2006
Resolved 26 May 2006
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 24 April 2006 Resolved
Prove panel & switchboard breakers are properly labeled & sized IAW with the ships approved one line DWG. (Methanol pump breaker/ fwd engine room panel)
Due 27 May 2006
Resolved 26 May 2006
Navigation › Piloting/Steering
Issued 9 August 2002 Resolved
NO UPDATED 2002 LIGHTLIST PROVIDED. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2002
Resolved 9 August 2002
Documentation › Markings/Placards
Issued 9 August 2002 Resolved
LIFERAFTS NOT MARKED WITH VESSEL NAME. LEGACY COMPONENT DESC: LIFESAVING
Due 9 September 2002
Resolved 9 August 2002
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 9 August 2002 Resolved
NO UPDATED COMPASS DEVIATION CARD AVAILABLE.
Due 9 September 2002
Resolved 9 August 2002
Lifesaving › Lifebuoys › Stowage
Issued 9 August 2002 Resolved
LIFERINGS NOT ARRANGED FOR QUICK RELEASE.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2002
Resolved 9 August 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 9 August 2002 Resolved
LIQUID MUD TRANSFER HOSES NOT ANNUALLY TESTED.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2002
Resolved 9 August 2002
Electrical › Electrical Distribution System (service)
Issued 9 August 2002 Resolved
REPAIR GROUND ON MAIN DISTRIBUTION PANEL. LEGACY COMPONENT DESC: Ground Detection
Due 9 September 2002
Resolved 9 August 2002
Engineering
Issued 29 June 2000 Resolved
01. HARD PIPE MAIN ENGINE(S) LUBE OIL COOLER LINES. NO FLEXIBLE HOSE TO BE LONGER THAN 30".
Condition: Unknown
Due 29 June 2000
Resolved 29 June 2000
Engineering
Issued 16 May 1997 Resolved
INSTALL PROPER OVERSPEED TRIP ON THE PORT MAIN DIESEL ENGINE.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Construction/Loadline
Issued 16 May 1997 Resolved
REPAIR OR REPLACE THE STEERING GEAR BILGE ALARM.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Documentation
Issued 19 May 1995 Resolved
PROVIDE A COPY OF THE VESSEL'S LOADLINE CERTIFICATE TO MSO MORGAN CITY.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Documentation
Issued 19 May 1995 Resolved
PROVIDE A COPY OF THE VESSEL'S DEVIATION CARD TO MSO MORGAN CITY.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Navigation
Issued 19 May 1995 Resolved
PROVIDE A COPY OF THE VESSEL'S RADIO STATION LIC. TO MSO MORGAN CITY.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Documentation
Issued 19 May 1995 Resolved
PROVIDE A COPY OF THE VESSEL'S WASTE MANAGEMENT PLAN TO MSO MORGAN CITY.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Documentation
Issued 19 May 1995 Resolved
PROVIDE A COPY OF APPROVED STABILITY LETTER TO MSO MORGAN CITY.
Condition: Unknown
Due 31 May 1995
Resolved 25 May 1995

Casualty record · 1

15 August 2021Routine · role: Involved in a Marine Casualty · 1 injured · activity 7294278
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.