Records from 1985 to 1996. Most recent: inspection, 13 May 1996.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 31
13 May 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1082530
28 July 1994
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1172720
29 June 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 860889
19 July 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1153693
21 June 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1154683
24 March 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1149171
2 March 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 835254
3 December 1992
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135144
15 October 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 940608
15 October 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941544
6 September 1991
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 941988
26 June 1991
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1228560
19 June 1990
COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1222298
9 August 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1210167
9 August 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1346937
13 July 1989
Re-Inspection · Plan Review "T" Boat
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1352305
19 April 1989
Plan Review "T" Boat
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1350714
13 February 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1035618
28 December 1988
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036637
26 May 1988
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1204553
12 November 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1025053
18 August 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1016101
3 August 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1029331
2 June 1987
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1332499
13 August 1986
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1018134
18 July 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1297581
30 June 1986
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 988330
3 December 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 984946
4 November 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1293382
25 June 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1292325
10 June 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1292322
Documentation
Issued 21 June 1993
Resolved
PROVIDE PROOF OF ENROLLMENT IN CHEMICAL TESTING PROGRAM PURSUANT TO 46CFR16.260. THIS REQUIRMENT NEEDS TO BE COMPLETED NOT LATER THAN 01JUL93.
Condition: Unknown
Due 21 June 1993
Resolved 21 June 1993
Documentation
Issued 3 December 1992
Resolved
PROVIDE ADDITIONAL DRAINAGE MEANS FOR WELLDECK. SUBMIT PLANS TO [name withheld] FOR ARRIVAL PRIOR TO INSTALLATION.
Condition: Unknown
Due 3 December 1992
Resolved 3 December 1992
Construction/Loadline
Issued 6 September 1991
Resolved
REPLACE THREE FASTENERS LOCATED ON PORT SIDE OF ENGINE ROOM, TWO AT BASE OFRIBS IN FORWARD MOST PORT SIDE OF ENGINE ROOM, AND ONE IN SECOND STRINGER_x001C_ FROM KEEL ON PORT SIDE, STAIGHT INBOARD FROM OTHER TWO.
Condition: Unknown
Due 12 September 1991
Resolved 12 September 1991
Construction/Loadline
Issued 26 June 1991
Resolved
VESSEL MUST UNDERGO A U/W RIDE PRIOR TO OPERATION.
Condition: Unknown
Due 26 June 1991
Resolved 26 June 1991
Documentation
Issued 26 June 1991
Resolved
VESSEL MUST HAVE MARPOL ANNEX V PLACARD PLACED ON BOARD.
Condition: Unknown
Due 26 June 1991
Resolved 26 June 1991
Engineering
Issued 26 June 1991
Resolved
VESSEL MUST HAVE A OPERATIONAL TEST OF ENGINE CONDUCTED PRIOR TO OPERATION.
Condition: Unknown
Due 26 June 1991
Resolved 26 June 1991
Documentation
Issued 26 June 1991
Resolved
OWNER MUST RENEW MARINE RADIO OPERATOR PERMIT.
Condition: Unknown
Due 26 June 1991
Resolved 26 June 1991
Construction/Loadline
Issued 19 June 1990
Resolved
COMPLETE TEMPORARY REPAIRS AS PROPOSED TO ROTTED AREAS (PT SIDE AMISDHIPS) PRIOR TO PLACING VSL IN WATER. VSL HAS ISOLATED AREAS OF ROT IN PLANK 32 38, 39,AND 42. OWNER PROPOSED TEMPORARY REPAIRS WITH PERMANENT REPAIRS TO BE COMPLETED IN THE FALL. (PLANKS COUNTED FROM STERN)
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990
Construction/Loadline
Issued 19 June 1990
Resolved
MAKE PERMANENT REPAIRS TO ROTTED AREA IN BOTTOM PLANKS ALONG KEEL IN WAY OFENGINEROOM. VLS HAS ISOLATED AREAS OF ROT IN PORT SIDE, PLANKS 32, 38, 39AND 42. (PLANKS COUNTED FROM STERN).
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990
Lifesaving
Issued 13 July 1989
Resolved
RENEW THE PENDANTS ON THE BUOYANT APPARATUS.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Engineering
Issued 13 July 1989
Resolved
PROVIDE A GROUND WIRE IN WAY OF FLEXIBLE HOSE IN THE FUEL FILL.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Construction/Loadline
Issued 13 July 1989
Resolved
PLUG THE UNUSED SEA VALVE FORWARD OF THE MAIN ENGINE.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Navigation
Issued 13 July 1989
Resolved
RENEW THE BROKEN LENS ON THE STARBOARD RUNNING LIGHT.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Engineering
Issued 13 July 1989
Resolved
REPLACE THE NON-APPROVED 3/8" FUEL HOSE IN THE FUEL VENT LINE WITH AN APPROVED FUEL HOSE AT LEAST 5/8" IN DIAMETER.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Lifesaving
Issued 26 May 1988
Resolved
PROVIDE 3 ADDITIONAL ADULT AND 1 CHILD PFD'S.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Documentation
Issued 26 May 1988
Resolved
PROVIDE PROPER DOCUMENTATION FOR VESSEL.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Electrical
Issued 3 August 1987
Resolved
PROVIDE ELECTRICAL BONDING FOR ALL METALLIC THROUGH HULL FITTINGS
Condition: Unknown
Due 3 August 1987
Resolved 3 August 1987
Electrical
Issued 3 August 1987
Resolved
RENEW VESSEL'S ELECTRICAL WIRING SYSTEM SO AS TO CONFORM WITH ELECTRICAL PLANS APPROVED BY [name withheld].
Condition: Unknown
Due 3 August 1987
Resolved 3 August 1987
Construction/Loadline
Issued 3 August 1987
Resolved
PROVIDE CAPTIVE CHAIN FOR THE FORWARD HATCH IN WAY OF THE PASSENGER ACCOMODATION SPACES.
Condition: Unknown
Due 3 August 1987
Resolved 3 August 1987
Construction/Loadline
Issued 2 June 1987
Resolved
PROVIDE SECURING CHAIN AND DEVICES FOR THE FORWARD HATCH COVER IN WAY OF THE PASSENGER SPACES.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Lifesaving
Issued 2 June 1987
Resolved
PROVIDE ON BOARD AN APPROVED COAST GUARD RING BUOY
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Electrical
Issued 2 June 1987
Resolved
PROVIDE ELECTRICAL BONDING FOR ALL METALLIC THROUGH HULL FITTINGS.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Documentation
Issued 2 June 1987
Resolved
RENEW THE FCC STATION LICENSE.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Navigation
Issued 2 June 1987
Resolved
PROVIDE ON BOARD A CURRENT EDITION OF THE U.S. COAST PILOT.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987