MAERSK CASSANDRA

MAERSK CASSANDRA is a 1995 tank ship. The Coast Guard has recorded 26 inspections since 1995, most recently in October 2010, along with 7 deficiencies and 3 operational controls.

Records from 1995 to 2010. Most recent: inspection, 21 October 2010.

Built
1995
Last inspected
21 October 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9079183 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
421952
Flag
UNITED KINGDOM
—
Maury page id
psix-421952

Inspections, by type

…with no type recorded11
Years with a record 11 calendar years (1995–2010)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28226 - Convention (Subpart B), Gross Ton
12677 - Convention (Subpart B), Net Ton
46737 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

21 October 2010 COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3878641
14 October 2010 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3869654
19 January 2010 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3666108
28 November 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3370499
29 April 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3194891
15 April 2008 ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3184567
8 March 2007 Ballast Water Examination · ISPS III Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2883733
26 February 2005 COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2299891
18 March 2003 Security Inspection
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 1760755
1 February 2003 MARPOL Annex V Examination · Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1736201
13 August 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1660604
19 February 2002 Security Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1487453
19 February 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1487577
1 February 2002 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1482734
27 January 2000 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 274132
20 January 2000 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 273744
20 January 2000 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1045616
23 August 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 419520
23 August 1998 Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 797012
27 July 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 405863
26 July 1997 Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 781321
24 June 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 392524
24 June 1996 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1456388
27 November 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 384760
18 May 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 378397
18 May 1995 Tank Vessel Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1460792

Deficiency record · 7

Electrical › Electrical Distribution System (service) › Ground Detection
Issued 15 April 2008 Resolved
A ground is detected in the 220V distribution panel. SOLAS 74 (1992 Cons. Ed.) II-1/45
Action required: 15 - Rectify deficiencies by next port
Due 25 April 2008
Resolved 29 April 2008
Resolution: Received proper documentation from Bureau Veritas satisfying requirement.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 April 2008 Resolved
Class A Fire Doors in Engine Room are not self closing. SOLAS 74 (1992 Cons. Ed.) II-2/30
Action required: 15 - Rectify deficiencies by next port
Due 25 April 2008
Resolved 29 April 2008
Resolution: Received proper documentation from Bureau Veritas satisfying requirement.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 15 April 2008 Resolved
Hot spots have been identified on the incinerator, creating a fire hazard.
Action required: 15 - Rectify deficiencies by next port
Due 25 April 2008
Resolved 29 April 2008
Resolution: Received proper documentation from Bureau Veritas satisfying requirement.
Deck/Cargo › Inert Gas System › Venting System
Issued 8 March 2007 Resolved
Cargo tanks #5 and #7 above 8% oxygen. SOLAS 2001 II-2, REG 62.2
Due 8 March 2007
Resolved 8 March 2007
Resolution: Tanks were brought down below 8%.
Documentation
Issued 20 January 2000 Resolved
Painted loadline is below permanent loadline. Permanently and properly mark loadline IAW Loadline Certificate. ICLL, Regulation 8.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Documentation
Issued 24 June 1996 Resolved
No person in charge of cargo operations with documentation of training for the vapor control system(VCS) per 46 CFR 39.10-11. This item must be corrrected before operating the vapor control system.
Condition: Unknown
Due 25 July 1996
Resolved 26 June 1996
Documentation
Issued 24 June 1996 Resolved
No approved Crude Oil Wash Operations and Equipment Manual as per 33 CFR 157.118. This item must be corrected before operation the COW system or loading a cargo requiring use of the system.
Condition: Unknown
Due 25 July 1996
Resolved 26 June 1996

Ownership record