MAURY USCG vessel records Sign in
← All vessels

T-1700

T-1700 is a 1953 tank barge. The Coast Guard has recorded 45 inspections since 1982, most recently in September 1995, along with 10 deficiencies.

Records from 1982 to 1995. Most recent: inspection, 5 September 1995.

Built
1953
Last inspected
5 September 1995
Documentation
Invalid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-42199

Inspections, by type

…with no type recorded27
Years with a record 13 calendar years (1982–1995)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)232.0 ft
Registered tonnagegross 905 / net 905
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · NASHVILLE, TN, UNITED STATES · built 1953
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNot recorded
Trade endorsementsNot recorded
DocumentationInvalid
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it905 - Regulatory (Subpart C or D), Gross Ton
905 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 45

5 September 1995 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1186521
24 January 1995 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 827587
10 January 1994 Damage Survey · Examination of Repairs · Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1163363
23 December 1993 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 642149
29 November 1993 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 148047
5 August 1993 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 845446
2 February 1993 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1137047
17 November 1992 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 534224
18 June 1992 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 539198
10 June 1992 Deficiency Check · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1265027
28 April 1992 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 959091
25 November 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 455203
7 November 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 476531
8 October 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 452337
1 April 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 538466
6 March 1991 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 929807
6 March 1991 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1000700
5 March 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 514187
13 September 1990 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 339326
5 September 1990 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 470810
8 August 1990 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 470608
6 August 1990 Hull Examination · Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 902541
5 January 1990 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 489350
29 September 1989 Examination of Repairs · Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1005961
18 July 1989 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 517117
31 March 1989 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1193992
24 January 1989 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 518101
24 January 1989 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 893949
2 December 1988 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1206847
18 July 1988 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 324568
11 July 1988 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1032399
18 May 1988 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 530218
20 October 1987 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 493315
4 June 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1312159
7 May 1987 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1022866
4 May 1987 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1327728
5 March 1987 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 463145
9 April 1986 Deficiency Check · Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307697
30 March 1986 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 997848
23 July 1985 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1292695
31 May 1985 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1288744
22 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979756
9 September 1984 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 532734
14 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973942
27 March 1982 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 969067

Deficiency record · 10

Construction/Loadline
Issued 10 January 1994 Resolved
PRIOR TO LOADING CARGO, RENEW ALL SIDESHELL PLATING WHICH HAS BEEN IDENTIFIED IN ASHLAND OIL'S GAUGING REPORT DATED 10JAN94, LESS THAN 0.281 INCHES.
Condition: Unknown
Due 31 August 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 28 April 1992 Resolved
AT THE NEXT GASFREE AVAILABILITY, PERMANENTLY AFFIX THE BARGE WARNING SIGN_x001C_TO ITS PROPER LOCATION. MAINTAIN TEMPORARY LASHINGS UNTIL SUCH TIME.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Construction/Loadline
Issued 24 January 1989 Resolved
MAKE PERMANENT REPAIRS TO THE FORWARD PORT SIDE TIMBERHEAD PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 24 January 1989
Resolved 24 January 1989
Construction/Loadline
Issued 4 May 1987 Resolved
REPAINT ALL DRAFT MARKS PRIOR TO LOADING CARGO BUT NOT LATER THAN 31 MAY 87
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Construction/Loadline
Issued 4 May 1987 Resolved
MAKE PERMANENT REPAIRS TO 6" HORIZONTAL FRACTURE IN WAY OF PORT BOW CORNER AT DECK AT NEXT GAS FREE AVAILABILITY BUT NOT LATER THAN 31 OCTOBER 1987.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Deck/Cargo
Issued 4 May 1987 Resolved
RENEW BROKEN VALVE HANDLE IN WAY OF PORT STERN DRIP TANK DRAIN VALVE PRIOR TO 31 MAY 87.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Deck/Cargo
Issued 4 May 1987 Resolved
MAKE PERMANENT REPAIRS TO RIPPED "D" RING MOUNTING ON DECK IN WAY OF STBD STERN DECK WINCH NOT LATER THAN 30 JUN 87.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Deck/Cargo
Issued 4 May 1987 Resolved
RENEW P/V VALVE FLAME SCREENS IN WAY OF #1 PORT C/T, #1 STBD C/T AND #2 PORT C/T PRIOR TO LOADING CARGO BUT NOT LATER THAN 31 MAY 87.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Deck/Cargo
Issued 4 May 1987 Resolved
TIGHTEN/REPACK ALL C/T REACH ROD PACKING GLANDS PRIOR TO LOADING CARGO BUT NOT LATER THAN 31 MAY 87.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Construction/Loadline
Issued 30 March 1986 Resolved
OFFLOAD CARGO AND MAINTAIN TEMPORARY REPAIRS TO THE HOLES IN THE #1 PORT AND THE #3 STBD CARGO TANKS. PRIOR TO RELOADING ANY CARGO OR IN ANY CASE NO LATER THAN 15 APRIL 1986 EFFECT PERMANENT REPAIRS TO THE ABOVE CARGO TANKS.
Condition: Unknown
Due 30 March 1986
Resolved 30 March 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.