Records from 2016 to 2025. Most recent: inspection, 5 May 2025.
Inspection history · 15
5 May 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8129192
25 March 2025
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8097159
25 March 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7884447
16 July 2023
Type not recorded
No type recorded · STATION ST LOUIS · USCG Heartland District (CGD-H) · Activity 7746681
26 April 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7679010
29 March 2022
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7401907
30 March 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7135209
23 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6985998
2 March 2020
Drydock Exam · Administrative Inspection · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6918886
19 April 2019
COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6665957
23 March 2018
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6389074
5 June 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6166671
26 April 2017
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6174758
10 April 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6121264
28 March 2016
DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5841951
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 25 March 2025
Resolved
Each vessel inspected and certificated under the provisions of this subchapter must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the terms of the certificate. The max passenger marking on the netting need replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2025
Resolved 5 May 2025
Resolution: Received picture of new markings.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2025
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Add markings to both fuel shutoff valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2025
Resolved 5 May 2025
Resolution: Received picture of new fuel shutoff labels.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 25 March 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Post new life jacket donning instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2025
Resolved 5 May 2025
Resolution: Received picture of new life jacket donning instructions.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Remove dead end wire under helm.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2025
Resolved 5 May 2025
Resolution: Received picture of wiring under helm, with dead end wires removed or terminated properly.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 25 March 2024
Resolved
At each inspection for certification, the owner/operator shall have the vessel ready for inspection of the condition of the standing and running rigging. The inspection revealed wires in the eye of the outhaul line on the boom were frayed. Repair/renew within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 April 2024
Resolution: Received photos of newly installed outhaul line.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 March 2021
Resolved
Mast has missing cover plate on PORT side which could allow water to enter mast. Cover the opening to the satisfaction of the attending Coast Guard marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 29 April 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 March 2021
Resolved
Sail rail guides have separated from main mast; secure sail rail guides to mast to the satisfaction of the attending Coast Guard marine inspector.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 29 April 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 March 2021
Resolved
Fore stay bridle lower shackle has incorrect pin, replace and mouse to the satisfaction of the attending Coast Guard marine
inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 29 April 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2020
Resolved
Attach float light to ring life buoy as per stated site. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 17 July 2020
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 June 2020
Resolved
Ensure all battery connections are made by permanant means (nuts not wing nuts).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 17 July 2020
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 June 2020
Resolved
Check all rigging hardware and secure with mousing wire as appropriate (shackles, turn buckles etc).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 17 July 2020
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2020
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Inspection found Ports side batteries had wing nuts on the terminals. Replace wing nuts with nuts on battery terminals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2020
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 March 2020
Resolved
Inspection found PORT and STBD side rudders posts loose. Prove to the satisfaction of the Coast Guard marine inspector that the bearings are within manufacture tolerance and/or correct assembly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2020
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 March 2020
Resolved
STBD side engine mounting hardware was found loose. Correct hardware to the satisfaction of the Coast Guard marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2020
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 10 March 2020
Resolved
PORT side upper engine supporting D-ring backing bracket was pulling through the stern transom. Provide repair proposal to the Marine Inspector to original and final repairs to the the satisfaction of the marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2020
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 March 2020
Resolved
PORT and STBD side corners of the stern hull bottom transverse support beam has wood rot and de-lamination. Provide repair proposal to marine inspector and make proper repairs to original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2020
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 10 March 2020
Resolved
Center line longitudinal support beam aft area is showing de-lamination. Make proper repairs to damaged area to original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2020
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 10 March 2020
Resolved
PORT side quarter outboard hull upper area had crack in the gelcoat which penetrated into the fiberglass fabric. Provide repair propose to the marine inspector and make final repairs to the satisfaction of the marine inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2020
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 April 2018
Resolved
11 11199 - Ring buoy was not properly labeled with vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2018
Resolved 4 May 2018
Resolution: Ring buoy properly labeled with vessel name.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 19 April 2018
Resolved
05 05199 - Post Emergency Broadcast Instructions near radio installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2018
Resolved 4 May 2018
Resolution: Emergency broadcast instructions posted.
Fire Fighting › Fire Bucket › Availability
Issued 19 April 2018
Resolved
07 07108 - Provide 3 fire buckets of proper size, properly stenciled, and outfitted with lanyards for retrieval.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2018
Resolved 4 May 2018
Resolution: Three fire buckets placen on board vessel.
Documentation › Markings/Placards › Lifejacket Placard
Issued 19 April 2018
Resolved
11 11199 - Provide lifejacket donning instructions on starboard side stowage box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2018
Resolved 4 May 2018
Resolution: Donning instructions placed in starboard side stowage box.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 May 2017
Resolved
Grab line attached to throwable life ring buoy was beginning to show signs of dry rot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 5 June 2017
Resolution: Received phone call from [name withheld] that this life ring buoy has been replaced.
Lifesaving › Hand Flares › Quantity
Issued 7 April 2016
Resolved
Prove receipt of one missing orange hand flare (or substitute red flare)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 18 April 2016
Resolution: Received confirmation of purchase of missing flare.