MAURY USCG vessel records Sign in
← All vessels

SAN PEDRO *

SAN PEDRO * is a 1945 freight ship. The Coast Guard has recorded 27 inspections since 1984, most recently in May 2000, along with 50 deficiencies.

Records from 1984 to 2000. Most recent: inspection, 6 May 2000.

Built
1945
Last inspected
6 May 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5224742 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-42204

Inspections, by type

…with no type recorded16
Years with a record 6 calendar years (1984–2000)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it0 - Dead Weight, Ton
17033 - Displacement, Ton
18420 - Regulatory (Subpart C or D), Gross Ton
14422 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 27

6 May 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 122871
6 January 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1317356
7 October 1987 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1013685
6 February 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1010268
6 December 1986 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1004736
6 December 1986 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332565
22 November 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019322
22 October 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1010457
10 October 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1008545
29 August 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 311162
15 August 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 461371
15 August 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986767
1 August 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 996486
23 June 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 996485
21 March 1986 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 993585
14 March 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 996484
14 March 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304886
1 March 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986114
20 February 1986 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 987584
15 February 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1300623
23 January 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 999776
24 June 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1290678
7 June 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 977863
3 June 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286549
2 June 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1295364
18 December 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1284774
7 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974191

Deficiency record · 50

Construction/Loadline
Issued 6 February 1987 Resolved
REMOVE SCALE BUILD-UP ON THE MACHINERY SIDE OF THE VESSEL'S SEA CHESTS FOR FURTHER EXAMINATION AT VESSEL'S NEXT DRYDOCK.
Condition: Unknown
Due 31 July 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 15 February 1986 Resolved
MAKE REPAIRS TO ENGINE BOX IN MOTOR LIFEBOAT TO REGAIN THE ORIGINAL WATER- TIGHT INTEGRITY OF THE ENCLOSURE.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Fire Fighting
Issued 15 February 1986 Resolved
IAW CHAP. II 2, REG. 20 OF THE AMENDMENTS TO THE INTERNATIONAL CONVENTION FOR THE SAFETY OF LIFE AT SEA, 1974, PROVIDE A DUPLICATE SET OF FIRE CON- TROL PLANS OR BOOKLET CONTAINING SUCH INFO AT THE GANGWAY, MAIN DECK, WEATHER. WHTIS INFO SHALL BE STORED IN A PORTABLE WATERTIGHT CONTAINERS.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Fire Fighting
Issued 15 February 1986 Resolved
MOUNT AN APPROVED FIRE EXTINGUISHER BRACKET FOR THE FIRE EXTINGUISHER IN THE BOSUN STORE ROOM.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Fire Fighting
Issued 15 February 1986 Resolved
MAKE REPAIRS TO THE FIRE/FLUSHING PUMP FOUNDATION BY NO LATER THAT 31 JULY 86.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Fire Fighting
Issued 15 February 1986 Resolved
DEMOSTRATE THE PROPER OPERATION OF THE WATERTICHT DOOR REMOTE POSITION INDICATOR BY NO LATER THAN 1 MARCH 86.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Fire Fighting
Issued 15 February 1986 Resolved
PERFORM HYDROSTATIC TEST OF ALL FIRE HOSES.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Fire Fighting
Issued 15 February 1986 Resolved
REPLACE 3 100# CO2 BOTTLES IN MAIN BANK; THE 3 EMPTY BOTTLES ARE CYLINDER NUMBERS 4599, 18055 AND 9160.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Lifesaving
Issued 15 February 1986 Resolved
MAKE PERMANENT REPAIRS TO FORWARD MOST CORNER OF LIFEBOAT WINCH HOUSING, STBD SIDE.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Lifesaving
Issued 15 February 1986 Resolved
PERFORM A SUSPENSION AND RELEASE TEST OF THE STABOARD LIFEBOAT.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Engineering
Issued 15 February 1986 Resolved
MAKE AVAILABLE FOR FIRESIDE, WATERSIDE BOILER VALVE MOUNTINGS OPENED AND THE SETTING AND SEALING OF THE STBD BOILER TO THE [name withheld] NOT LATER THAT 1 MARCH 86.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Engineering
Issued 15 February 1986 Resolved
MAKE AVAILABLE FOR INTERNAL EXAMINATION OF THE MAKE-UP WATER EVAPORATOR BY NO LATER THAN 1 MARCH 86.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Engineering
Issued 15 February 1986 Resolved
EFFECT REPAIRS TO THE EXISTING 20 INCH FORWARD LOW SEA SUCTION VALVE OR INSTALL A REPLACEMENT PRIOR TO 01 MAR 86.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Engineering
Issued 15 February 1986 Resolved
EFFECT REPAIRS TO THE AFT LOW SEA SUCTION VALVE PRIOR TO 15 MARCH 86.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Engineering
Issued 15 February 1986 Resolved
RENEW THE PORT BOILER CORBEL AND AS NECESSARY THE FURNACE FLOORING BY NO LATER THAN 15 MARCH 86.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Engineering
Issued 15 February 1986 Resolved
REMOVE SCALE BUILD-UP ON THE MACHINERY SIDE OF THE VESSELS SEA CHESTS FOR FURTHER EXAMINATION AT THE VESSELS NEXT DRYDOCKING (DUE JULY 86).
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Engineering
Issued 15 February 1986 Resolved
HARD PIPE IS TO BE FITTED IN WAY OF THE PRESENTLY FITTED HOSE ASSY. AT THE BILGE PUMP OVERBOARD/GEAR CASE DE-HYDRATOR LINE CONNECTION.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Engineering
Issued 15 February 1986 Resolved
PROPERLY FIT GEAR BOX VENT LINE HOSE ASSY. TO THE STBD SIDE OF THE MAIN REDUCTION GEAR BOX PRIOR TO 15 MARCH 86.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Engineering
Issued 15 February 1986 Resolved
RENEW THE WASTED CLAMPS AND WASTED FLANGE FASTERNERS BETWEEN THE FORWARD AND AFT LOW SEA SUCTION VALVES PRIOR TO 15 MARCH 86.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Engineering
Issued 15 February 1986 Resolved
MAKE REPAIRS IN WAY OF THE PINHOLE STEAM LINE LEAK ON THE RETURN LINE FROM THE STBD FUEL OIL SETTLER TANK ON THE SHAFT ALLEY/MACHINERY SPACE BULKHEAD PRIOR TO 15 MARCH 86.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Navigation
Issued 15 February 1986 Resolved
MAKE PERMANENT REPAIRS IN WAY OF RED HAND PATCH TO THE SUPPLY LINE IN THE EMERGENCY HAND STEERING PUMP ASSY.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Electrical
Issued 15 February 1986 Resolved
THE DISTRIBUTION PANELS FOR ELECTRICAL CURUIATRY ARE TO BE FITTED WITH THE PROPER SIZE LINE FUSES PRIOR TO 15 MARCH 86.
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Fire Fighting
Issued 15 February 1986 Resolved
MOUNT NEW APPROVED TYPE PORTABLE FIRE EXTINGUISHER BRACKETS AT FIRE STATIONS 29 AND 30 (ENGINE ROOM THROTLE LEVEL STBD SIDE, FWD BEHIND REFER PANEL AND LOWER ENGINE RPOT SIDE, FWD, ABOVE BILGE SUCTION MANIFOLD).
Condition: Unknown
Due 15 February 1986
Resolved 15 February 1986
Lifesaving
Issued 2 June 1985 Resolved
RENEW OR PROVE THE INTEGRITY OF THE #1 LIFEBOAT RELEASING GEAR BY MEANS 0F A 100% DEADWEIGHT TEST AS PER 46 CFR 94.35-5 (B).
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Lifesaving
Issued 2 June 1985 Resolved
OUTFIT THE 1 LIFEBOAT WITH THE REQUIRED EQUIPMENT CONTAINED IN 46 CFR 94.20-10.
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Lifesaving
Issued 2 June 1985 Resolved
MAKE SUITABLE FOR USE THE PROVISION AND EQUIPMENT LOCKERS IN THE #1 LIFEBOAT.
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Lifesaving
Issued 2 June 1985 Resolved
RENEW THE SEA PAINTERS IN THE #1 AND #2 LIFEBOATS AS PER 46 CFR 94.120-15 (Z)
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Lifesaving
Issued 2 June 1985 Resolved
RENEW THE PORT AND STBD DAVIT LIFELINES AS PER 46 CFR 94.25-10 (B).
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Lifesaving
Issued 2 June 1985 Resolved
RENEW THE #1 AND #2 LIFEBOAT ROWLOCK CHAINS AS PER 46 CFR 94.20-15 (CC)
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Lifesaving
Issued 2 June 1985 Resolved
CHANGE THE FUEL IN THE #2 LIFEBOAT AS REQUIRED BY 46 CFR 97.15-45(D).
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Lifesaving
Issued 2 June 1985 Resolved
RENEW THE BROKEN FIRE EXTINGUISHER BRACKET FOR THE AFT FIRE EXTINGUISHER FOR THE #2 LIFEBOAT.
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Fire Fighting
Issued 2 June 1985 Resolved
CONDUCT A FLOW TEST OF THE CARGO HOLD FIXED CO2 EXTINGUISHING PIPING SYSTEMWITH A SUITABLE TEST MEDIUM AS REFQUIRED BY 46 CFR 91.25-20 (A) (3).
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Electrical
Issued 2 June 1985 Resolved
RENEW ALL MISSING GUARDS , GLOBES AND BURNED OUT INCANDESANT LIGHTS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Navigation
Issued 2 June 1985 Resolved
PROVIDE ON BOARD ALL NOTICES TO MARINERS AND UPDATE AFFECTIVE CHARTS AND PUBLICATIONS SINCE ISSUE 23-84 AL PER 46 CFR 97.05.
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Lifesaving
Issued 2 June 1985 Resolved
PROVIDE ON TWO (2) ADDITIONAL APPROVED AUTOMATIC ELECTRIC WATER LIGHTS AS PER 46 CFR 94.43-5 (B).
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Lifesaving
Issued 2 June 1985 Resolved
PROVIDE ON BOARD SIX (6) APPROVED RING LIFE BUOYS AS PER 46 CFR 94.43-5 (A)AND DISTRIBUTE AS PER 46 CFR 94.43-10.
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Documentation
Issued 2 June 1985 Resolved
RENEW THE CARGO SHIP SAFETY RADIOTELEGRAPHY CERTIFICATE AL REQUIRED BY 46 CFR 91.60-40 (C).
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Navigation
Issued 2 June 1985 Resolved
RENEW THE WASTED SOUND-POWERED TELEPHONE JUNCTION BOX LOCATED ON THE #2 LIFEBOAT DECK AS PER 46 CFR 113.30-25(B).
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Construction/Loadline
Issued 2 June 1985 Resolved
RENEW THE DAMAGE CARGO HATCH GASKET FOR THE #4 PORT FORWARD HATCH.
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Construction/Loadline
Issued 2 June 1985 Resolved
RENEW ALL ANTENNA WIRES FROM ALL STATEROOMS WHICH ARE INSTALLED THROUGH THE PORT LIGHT FRAME BOLTEDF RING AND REINSTALL THE BOLTS.
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Construction/Loadline
Issued 2 June 1985 Resolved
MAKE PROPERLY OPERABLE ALL PORT LIGHT AND DEADLIGHT COVER DOG BOLTS IN ALL SPACES EQUIPPED WITH SAME.
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Electrical
Issued 2 June 1985 Resolved
CROP AND RENEW THE WASTED EMERGENCY GENERATOR EXHAUST PIPE FROM THE PORT BOAT DECK.
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Construction/Loadline
Issued 2 June 1985 Resolved
CROP AND RENEW THE WASTED HAND RAILS THROUGH OUT VESSEL AS PER 46 CFR 92.25-5.
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Construction/Loadline
Issued 2 June 1985 Resolved
RENEW THE #1 CARGO HOLD MANHOLE SCUTTLE.
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Electrical
Issued 2 June 1985 Resolved
PROERLY HOOK-UP THE DRYER ELECERICAL CONNECTION BOX IN THE OFFICER,S LAUNDRY ROOM.
Condition: Unknown
Due 2 June 1985
Resolved 2 June 1985
Engineering
Issued 7 March 1984 Resolved
PRESENT DC HEATER FOR INTERNAL INSPECTION PRIOR TO 31 MAY 1984.
Condition: Unknown
Due 7 March 1984
Resolved 7 March 1984
Unknown
Issued 7 March 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL SAN PEDRO DN248238.
Condition: Unknown
Due 7 March 1984
Resolved 7 March 1984
Unknown
Issued 7 March 1984 Resolved
PRESENT STARBOARD BOILER FOR FIRESIDE WATERSIDE AND EXTERNAL INSPECTION PRIOR TO 31 MAY L984.
Condition: Unknown
Due 7 March 1984
Resolved 7 March 1984
Lifesaving
Issued 7 March 1984 Resolved
CONDUCT WEIGHT TEST OF STARBOARD LIFEBOAT.
Condition: Unknown
Due 7 March 1984
Resolved 7 March 1984
Engineering
Issued 7 March 1984 Resolved
PRESENT FORWARD AND AFT EVAPORATORS FOR INTERNAL INSPECTION PRIOR TO 31 MAY 1984.
Condition: Unknown
Due 7 March 1984
Resolved 7 March 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.