MAURY USCG vessel records Sign in
← All vessels

BORINQUEN

BORINQUEN is a 1945 freight ship. The Coast Guard has recorded 39 inspections since 1984, most recently in June 1989, along with 17 deficiencies.

Records from 1984 to 1989. Most recent: inspection, 22 June 1989.

Built
1945
Last inspected
22 June 1989
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5224845 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-42205

Inspections, by type

…with no type recorded22
Years with a record 6 calendar years (1984–1989)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 37 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it16977 - Dead Weight, Ton
17189 - Regulatory (Subpart C or D), Gross Ton
13044 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 39

22 June 1989 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1045080
19 January 1989 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 891575
1 November 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1202243
11 October 1988 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1196295
25 February 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1331866
29 January 1988 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1324257
28 January 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1013999
1 December 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1028313
13 November 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1023885
12 November 1987 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1333442
30 October 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019885
23 October 1987 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1335429
16 October 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016912
16 October 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016913
25 September 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1015082
4 September 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1013646
20 August 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339388
14 August 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1011527
14 August 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1340807
25 June 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1009424
24 April 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1324710
20 April 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010805
18 March 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 463042
20 February 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1322425
5 February 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319775
24 January 1987 Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1009866
2 October 1986 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1010012
27 August 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 311104
30 July 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 998095
29 July 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 437803
17 July 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 988574
18 October 1985 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 990451
19 September 1985 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 990617
2 August 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1290569
29 June 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 979986
24 April 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 982901
15 November 1984 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 979056
18 October 1984 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 975827
13 September 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 513289

Deficiency record · 17

Electrical
Issued 23 October 1987 Resolved
REPAIR AND MAKE OPERATIONAL ENGINEROOM BILGE ALARM.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Fire Fighting
Issued 23 October 1987 Resolved
REACTIVE OR INSTALL GENERAL ALRM BELL IN VICINITY OF THE SHAFT ALLEY AT NEXT DRYCOCKING.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987 Resolved
REPLACE AS NECESSARY WARN AND ROTTED SEATS, THWARTS AND WOODEN SUPPORTS IN BOTH PORT AND STARBOARD LIFEBOATS BY NEXT DRYDOCKING.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Engineering
Issued 23 October 1987 Resolved
MAKE PERMANENT REPAIRS TO EVAPORATOR OVERBOARD DISCHARGE.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Fire Fighting
Issued 23 October 1987 Resolved
MAKE PERMANENT REPAIRS TO BRACKET ON FRAME JUST FORWARD AND OUTBOARD OF THE FIRE PUMP AT THE TURN OF THE BILGE.
Condition: Unknown
Due 23 October 1987
Resolved 23 October 1987
Lifesaving
Issued 23 October 1987 Resolved
REPLACE BAILER-PORT LIFEBOAT
Condition: Unknown
Due 1 December 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 23 October 1987 Resolved
REPLACE NAPTHA FIREMAN'S OUTFIT
Condition: Unknown
Due 1 December 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 23 October 1987 Resolved
REPLACE CHEMOX CANNISTER FOR BREATING APPARATUS.
Condition: Unknown
Due 1 December 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 25 September 1987 Resolved
EXAMINE/ OPERATE STARBOARD LIFEBOAT DAVIT TO DETERMINE ACCEPTABILITY OF NEWFALLS AND CHECK RELEASING GEAR ON SAME.
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Lifesaving
Issued 20 August 1987 Resolved
REPLACE PORT AND STARBOARD LIFEBOAT LADDERS.
Condition: Unknown
Due 20 August 1987
Resolved 20 August 1987
Lifesaving
Issued 20 August 1987 Resolved
REPLACE FALLS FOR PORT AND STARBOARD LIFEBOATS.
Condition: Unknown
Due 20 August 1987
Resolved 20 August 1987
Engineering
Issued 14 August 1987 Resolved
REPLACE EVAPORATOR SHELL -- FWD EVAPORATOR --
Condition: Unknown
Due 29 June 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 14 August 1987 Resolved
COMPLETE INTERNAL EXAM ON DC HEATER.
Condition: Unknown
Due 14 August 1987
Resolved 14 August 1987
Electrical
Issued 24 January 1987 Resolved
MAKE PERMANENT REPAIRS TO #2 S/S DC GENERATOR. ACCOMPLISH BY 6 FEBRUARY 1987. VESSEL IS AUTHORIZED TO MAKE ONE TRIP FROM NEW YORK TO SAN JUAN, PR & RETURN WITH TEMPORARY DIESEL/AC GENERATOR INSTALLED. PERMANENT REPAIRS TO#2 S/S GENERATOR TO BE WITNESSED & MEET ACCEPTANCE OF ATTEND. CG INSPECTOR.
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Construction/Loadline
Issued 19 September 1985 Resolved
REPAIR SPRING RETURN ACTION ON ALL LOWER MACHINERY SPACE SOUNDING TUBES.
Condition: Unknown
Due 19 September 1985
Resolved 19 September 1985
Electrical
Issued 19 September 1985 Resolved
REPLACE INSULATION MATTING IN FRONT OF THE MAIN SERVICE BOARD.
Condition: Unknown
Due 19 September 1985
Resolved 19 September 1985
Construction/Loadline
Issued 18 October 1984 Resolved
CROP AND RENEW FIVE WASTED GOOSE NECK VENTS ON THE VESSEL'S STERN.
Condition: Unknown
Due 18 October 1984
Resolved 18 October 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.