Records from 1983 to 1988. Most recent: inspection, 19 July 1988.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 42
19 July 1988
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1032081
15 April 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 460203
24 March 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 990082
10 December 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001933
10 December 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309899
9 December 1987
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1001320
11 September 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 463606
17 August 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1031535
31 July 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029779
27 July 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1006481
22 July 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1023080
15 July 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1029568
11 July 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1326096
2 July 1987
Deficiency Check · Drydock Extension
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1011663
10 June 1987
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029823
21 April 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010026
6 March 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 462258
16 February 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323475
27 October 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325807
19 September 1986
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 501928
16 May 1986
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1304576
13 May 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299629
17 March 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307080
11 March 1986
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 991706
25 February 1986
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 989849
10 January 1986
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 306424
17 December 1985
Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1300829
23 October 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 992088
17 October 1985
Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1297931
2 August 1985
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 527263
25 July 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1288090
15 July 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1290634
15 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287590
5 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 981745
25 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288248
12 October 1984
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1286801
9 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975119
29 September 1984
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 974460
13 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974316
21 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979278
21 May 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1281083
9 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966627
Engineering
Issued 22 July 1987
Resolved
PROVE PROPER OPERATION OF SAFETY VALVES ON #1 AND #2 BOILERS.
Condition: Unknown
Due 22 July 1987
Resolved 22 July 1987
Accommodation/Occupational Safety
Issued 22 July 1987
Resolved
RENEW WASTED BATTERY ROOM EXHAUST VENTILATION DUCT LOCATED IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 22 July 1987
Resolved 22 July 1987
Engineering
Issued 22 July 1987
Resolved
PROVE PROPER OPERATION OF A.C. GENERATOR AIR COMPRESSOR RELIEF VALVE. TO BECOMPLETED.
Condition: Unknown
Due 22 August 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 22 July 1987
Resolved
MAKE PERMANENT REPAIRS TO THE SOFT PATCH ON THE SANITARY PIPING LOCATED IN LOWER LEVEL OF ENGINEROOM, STBD SIDE.
Condition: Unknown
Due 22 July 1987
Resolved 22 July 1987
Engineering
Issued 22 July 1987
Resolved
REPAIR LEAK IN 1/2" STEAM DRAIN LINE FROM NO. 2 GENERATOR.
Condition: Unknown
Due 22 July 1987
Resolved 22 July 1987
Fire Fighting
Issued 22 July 1987
Resolved
PROVE PROPER OPERATION OF AUDIBLE ALARM FOR SMOKE DETECTION SYSTEM PANEL ONBRIDGE.
Condition: Unknown
Due 22 July 1987
Resolved 22 July 1987
Construction/Loadline
Issued 10 June 1987
Resolved
MAKE PERMANENT REPAIRS TO POOP DECK IN WAY OF WASTAGE HOLE AT 12 F CARGO HOLD STARBOARD SIDE.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Construction/Loadline
Issued 10 June 1987
Resolved
MAKE PERMANENT REPAIRS TO FORWARD AND STARBOARD BULKHEADS OF AFTER MOST HOUSE ON POOP DECK.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Construction/Loadline
Issued 10 June 1987
Resolved
PROVIDE GAUGE READINGS FOR POOP DECK STARBOARD SIDE FRAMES 145 THROUGH 175 AVERAGING THREE READINGS PEP PLATE REMOVE ALL RED HAND.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Engineering
Issued 13 May 1986
Resolved
MAKE DC HEATER AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Construction/Loadline
Issued 25 February 1986
Resolved
REPAIR ALL WATER TIGHT DOORS TO OPERABLE CONDITION.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Electrical
Issued 25 February 1986
Resolved
REATTACH DECK LIGHT #5 HATCH PORTSIDE.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Electrical
Issued 25 February 1986
Resolved
INSTALL GENERAL LIGHTING FIXTURE GLOBES AND GUARDS WHERE MISSING IN FORPEAKLOCKER.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
REPAIR VENT PIPE WHERE THREADED AND INSTALL CHECK BALL ASSEMBLY #1 HATCH STBD / AFT.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Accommodation/Occupational Safety
Issued 25 February 1986
Resolved
REPAIR LAUNDRY VENT AND COVER WHERE WASTED, STBD SIDE AFT OF #11 HATCH ON MAIN HOUSE.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
REPAIR VENT COVER PORT SIDE OF AFT HOUSE NEXT TO PAINT LOCKER WTD.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Electrical
Issued 25 February 1986
Resolved
REMOUNT ELECTRICAL SWITCH BOX FOR PORT AFT EMBARKATION LIGHT.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
REPAIR D.B. FRESH WATER VENT PIPE #8 PORT.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
REPLACE MISSING DOG FOR NATURAL VENT COVER #1 HATCH STBD / FWD.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
REPLACE MISSING DOG FOR HATCH COVER #3 PORT FWD.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Engineering
Issued 25 February 1986
Resolved
RPAIR WASTED F.O. VENT,#2 HATCH STBD / AFT.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Engineering
Issued 25 February 1986
Resolved
REPAIR WASTED F.O. VENT, #5 HATCH STBD / AFT.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
REPAIR #5 HATCH COAMING WHERE FRACTURED AND BENT UP, STBD / AFT / CENTER COVER.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
REPAIR STBD AFT COWLED VENT DAMPER TO OPERABLE CONDITION AND REPAIR HANDLE WHERE WASTED. VENT ON FANTAIL.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Engineering
Issued 25 February 1986
Resolved
REPAIR WASTED F.O. VENT, #6 HATCH STBD / AFT.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
REMOVE PAINT FROM ALL GASKET SURFACES ON ALL WTD, HATCHES, VENTS, ECT.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
REPAIR WASTED COWLED VENT, PORT SIDE / AFT.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
REPLACE MISSING DOG #9 HATCH CENTER COVER STBD / AFT.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Engineering
Issued 25 February 1986
Resolved
REPAIR WASTED F.O. VENT, #10 HATCH STBD / AFT.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
REPLACE DOG ON HATCH TO STORES STBD SIDE EMBARKATION AREA WHERE MISSING.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
FABRICATE AND INSTALL MISSING COVER FOR NATURAL VENT ON FANTAIL STBD SIDE JUST AFT OF AFT HOUSE.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Construction/Loadline
Issued 25 February 1986
Resolved
RENEW GLASS IN PORTHOLE IN 12/4 MATES ROOM WHERE BROKEN AND REPLACE GASKET.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Fire Fighting
Issued 15 April 1985
Resolved
PRIOR TO 01MAY85 REPLACE HIGH VELOCITY FOG TIPS ATTACHED TO THE FIRE NOZZLES AT STATIONS #15,19 AND 25 WITH APPROVED FOG TIPS MANUFACTURED IN ACCORDANCE WITH 46 CFR 162.021.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985
Unknown
Issued 15 April 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, PANAMA, DN248241 AND ARE TO BE COMPLIED WITH BY 15MAY85.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985
Accommodation/Occupational Safety
Issued 15 April 1985
Resolved
MAKE PERMANENT REPAIRS TO ROPE LOCKER VENT ON PORTS DEFORECASTLE DECK. REPAIRS TO BE COMPLETED PRIOR TO 25MAY85 TO THE SATISFACTION OF THE COG- NIZANT OFFICER IN CHARGE MARINE INSPECTION AND ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985
Fire Fighting
Issued 15 April 1985
Resolved
MAKE OPERABLE IN ACCORDANCE WITH 46 CFR 96.05. GENERAL ALARM BELL IN PASSAGEWAY OUTSIDE OFFICERS RECREATION ROOM ON MAIN DECK PRIOR TO 15 MAUBS TO THE SATISFACTION OF COGNIZANT OCMI AND ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985
Fire Fighting
Issued 15 April 1985
Resolved
REPAIR, REPLACE OR REMOVE FIRE DETECTION SYSTEM ADDRESSED BY 46 CFR 95.05 PRIOR TO 01MAY85 TO THE SATISFACTION OF THE COGNIZANT OCMI AND ATTENDING MARINE INSPECTOR. IF THE FIRE DETECTION SYSTEM IS REMOVED, THE CO2 SYSTEM ADDRESSED BY 46CFR95.15 WILL BE TESTED TO THE SATISFACTION OF THE INSPECTOR
Condition: Unknown
Due 15 April 1985
Resolved 15 April 1985
Construction/Loadline
Issued 25 March 1985
Resolved
MAKE AVAILABLE FOR INSPECTION IN CONJUNCTION WITH ABS SURVEY ALL HATCH COVERS UPON ARRIVAL IN PORT ELIZABETH NEW JERSEY. MAKE REPAIRS AS REQUIREDBY ATTENDING INSPECTOR; IN NO CASE SHALL THIS INSPECTION START LATER THAN 09APR85.
Condition: Unknown
Due 25 March 1985
Resolved 25 March 1985
Unknown
Issued 9 October 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL PANAMA O.N. 248241.
Condition: Unknown
Due 9 October 1984
Resolved 9 October 1984
Unknown
Issued 9 October 1984
Resolved
MAKE PERMENENT REPAIRS TO THE IOCM RADAR. REPAIRS ARE TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI AND NOT LATER THAN THE VESSEL'S DEPARTURE FROM JACKSONVILLE, FLA.
Condition: Unknown
Due 9 October 1984
Resolved 9 October 1984
Navigation
Issued 29 September 1984
Resolved
10 CM RADAR INOP. REPAIR REQUIRES FABRICATION OF PEDESTAL PART.
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984