← All vessels
FROST 2
FROST 2 is a 1979 freight ship. The Coast Guard has recorded 23 inspections since 1995, most recently in February 2010, along with 22 deficiencies and 3 operational controls.
Records from 1995 to 2010. Most recent: inspection, 9 February 2010.
- Built
- 1979
- Last inspected
- 9 February 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 22 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7932654 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELQZ6
422222
Flag
RUSSIA
—
Maury page id
psix-422222
Inspections, by type
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Documentation record
Tonnage as PSIX records it12363 - Convention (Subpart B), Gross Ton
4065 - Convention (Subpart B), Net Ton
10112 - Dead Weight, Ton
17356 - Displacement, Ton
4065 - Convention (Subpart B), Net Ton
10112 - Dead Weight, Ton
17356 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 23
9 February 2010
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3677457
4 February 2010
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3756555
22 January 2010
Type not recorded
No type recorded · USCGC PELICAN (WPB 87327) · USCG Heartland District (CGD-H) · Activity 3670998
19 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3666262
17 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3665352
9 January 2009
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3384061
11 April 2008
ISPS III Exam · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3178111
31 January 2008
Ballast Water Examination · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3137086
26 November 2007
ISPS III Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3104330
26 June 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2974368
9 April 2007
Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2901567
6 February 2007
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2867905
4 April 2006
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2616625
10 January 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2564092
6 May 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2351235
15 April 2005
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2334410
15 April 2005
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2334427
26 January 2005
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2279768
18 March 2003
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1756239
7 October 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1686122
8 July 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 430325
17 September 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 457410
15 November 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 384768
Deficiency record · 22
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 11 April 2008
Resolved
Fuel oil and lube oil transfer lines were not tested hydrostatically to 1.5 times the maximum allowable working pressure. The vessel is prohibited from conducting bunkering operations in U.S. waters until bunkering lines have been properly tested at 5.25 BAR.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 11 April 2008
Resolved
The third officer, Vitaly Pakhomov's Liberian flag state endorsement incorrectly states that he holds a Chief Mate license.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 26 November 2007
Resolved
The vessel is not in compliance with its Minimum Safe Manning Certificate. The Second Officer, Third Officer and Chief Engineer do not have Liberian endorsements or receipts of application. Without C/E, 2/O, and 3/O the vessel does not meet the requirements of their Minimum Safe Manning. STCW Reg. I/4, I/10, I/14
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 26 November 2007
Resolved
Procedures for ensuring mariners have appropriate of competence and/or endorsements do not appear to be properly implemented at the company level or ship level. SOLAS 74 XI/3, ISM A/3, A/5, A/6 - Recommend external audit of company/ship procedures of recruitment/staffing.
Fire Fighting › Fire Pumps › Pumpshaft
Issued 26 November 2007
Resolved
Steady leak around shaft seal of the number 2 fire pump during operation. SOLAS 60 Reg I/11. To the satisfacton of Class.
Construction/Loadline › Structures › Deck Plating
Issued 26 November 2007
Resolved
Severe deck wastage starboard of the main diesel engine, above lube oil cooler. (Reefer compressor space deck) SOLAS 60 Reg I/11. Correct to the satisfaction of Class.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 26 November 2007
Resolved
No "Discharge of Oil Prohibited" placard is posted at a conspicuous space in each machinery space or at the bilge and ballast pump control station as required by 33 CFR. To the satisfaction of the Coast Guard.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (air intake)
Issued 9 April 2007
Resolved
The sea water cooling discharge pipe for the auxiliary engine has a temporary patch.
Engineering › Diesel Engine (propulsion-direct drive) › Piston
Issued 9 April 2007
Resolved
The injector cooling system pipe for the main engine has two temporary patches above the piston cooling pump.
Fire Fighting › Fire Hydrants › Condition
Issued 4 April 2006
Resolved
Fire Hydrant in forward of the ship before forecastle is blocked and no water is passing threw.Vessel is to repair the Hydran
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 4 April 2006
Resolved
Vessels fire control plan has CO2 battery and CO2 release stations marked. but there is no CO2 systems on the vessel, Fire plan needs to be corrected
Construction/Loadline › Hull › Side Shell
Issued 2 May 2005
Resolved
While in Charleston SC, The assist tugs line snapped causing the vessel to hit the pier
Navigation › Piloting/Steering › Gyro Compass
Issued 15 April 2005
Resolved
Vessel's main gyrocompass is inoperable. Vessel was authorized an LOD.
Construction/Loadline › Structures › Deck Plating
Issued 26 January 2005
Resolved
Several deck plates in boiler room (engine room) severely cracked and/or wasted. Deck plates need to be replaced to satisfaction of class. Cite: ILO147 Solas 74 1/11
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 January 2005
Resolved
Electrical cables leading into steering gear room encased in cement/wood block. Provide permanent means of ensuring watertight integrity in accordance with SOLAS 74 II-1 Reg 13.b to the satisfaction of classification society
Fire Fighting › Fire Main › Condition
Issued 26 January 2005
Resolved
1" diameter hole on starboard side forward section of fire main.to the satisfaction of the coast guard
Engineering › Bilge Water Management System › Piping
Issued 26 January 2005
Resolved
Leaks on the bilge water discharge pipe. Repair or replaced pipe as new in accordance with SOLAS 74 (amended) II-1 Reg 21
Construction/Loadline › Structures › Door
Issued 26 January 2005
Resolved
Knife edge (coaming) on emergency fire pump hatchway (door). Repair and demonstrate to the satisfaction of class watertight integrity
Deck/Cargo › Holds/Tanks › Coaming
Issued 26 January 2005
Resolved
Coaming on cargo holds hatches are wasted. Demonstrate to satisfaction of class watertight integrity.
Engineering › Generator (propulsion-electric)
Issued 7 October 2002
Resolved
Repair all exhaust manifolds on all generators (1-4) prior to 07 Dec 02. To the satisfaction of Classification Society. LEGACY COMPONENT DESC: Exhaust Manifolds
Accommodation/Occupational Safety › Potable Water System
Issued 7 October 2002
Resolved
Repair/Renew as original, leaking hot water pump. Pump is port side of #1 SSDG. Class Society to attest of repairs and location of pump, as pump is located next to electrical switch board. Correct no later than 07 Dec. 02. LEGACY COMPONENT DESC: Hot Water Pump
Pollution Prevention/Response › Prevention Equipment
Issued 7 October 2002
Resolved
Prior to conducting bunkering operations in U.S. waters, provide proper containment around all F/O and L/O vents, connections, and transfer points, as per 33CFR155.320. LEGACY COMPONENT DESC: Containment
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.