Records in 1995. Most recent: inspection, 30 March 1995.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Engineering
Issued 29 March 1995
Resolved
Prior to departing, make repairs to starboard side fuel oil vent line wherefuel oil is leaking into after cargo hold.
Condition: Unknown
Due 29 March 1995
Resolved 6 April 1995
Engineering
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, make proper repairs to fuel oil fill line on starboard side in forward cargo hold. Rubber hose with hose clampsis not satisfactory.
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide documentation from vessel's homeFlag Administration that the ship's service generators are operational under load. 46 C.F.R. 90.25.
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide documentation from vessel's homeFlag Administration that vessel has an installed and functioning bilge system as required 46 C.F.R. 56.50-50.
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide on board current U.S. Coast Pilot (USCP 4) as required by 46 C.F.R. 97.05-05(c).
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide on board up to date charts as required by 46 C.F.R. 97.05-05(a).
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 29 March 1995
Resolved
Prior to departing, properly remove excess oil from engineroom bilges.
Condition: Unknown
Due 29 March 1995
Resolved 6 April 1995
Navigation
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide on board current Inland Navigation Rules as required by 46 C.F.R. 88.5.
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide for review a valid copy of the Flag Administration's 12 December 1994 dry dock survey report.
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide on board current U.S. Coast Guard Light List Vol. III as required by 46 C.F.R. 97.05-5(d).
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide on board current tide tables as required by 46 C.F.R. 97.05-5(f).
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide on board current tidal current tables as required by 46 C.F.R. 97.05-5(g).
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, make vessel available to home Flag Administration for readmeasurement and provide a valid cerificate of registry.
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide a valid crew list as require by 19 U.S.C. 1431._x001C_
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide for review documentation from the vessel's home [name withheld] indicating minimum manning requirements._x001C_
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 29 March 1995
Resolved
Prior to departing, properly remove fuel oil from aft cargo hold bilge wellsump.
Condition: Unknown
Due 29 March 1995
Resolved 21 April 1995
Deck/Cargo
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide documentation from vessel's homeFlag Administration that the vessel has an operational anchoring system.
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide a bilge slops piping outlet on deck incorporating a stop valve and a means to stop each pump as required by 33 C.F.R. 155.420(a)(4&5).
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, properly install the vessel's inflatablelife raft so that it is in a float free arrangement with a weak-link attached to the seapainter as required by 46 C.F.R. 94.10-10.
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, properly mark on the vessel's hull draftmarks as required by 46 C.F.R. 97.40-10.
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 29 March 1995
Resolved
Piror to returning to U.S. waters, provide documentation from vessel's homeFlag Administration indicating that vessel's installed fire pumps are operational. 46 C.F.R. 95.10-5(a).
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 29 March 1995
Resolved
Prior to returning to U.S. waters, provide additional fire stations as required by 46 C.F.R. 95.10-10 (d) and (g).
Condition: Unknown
Due 29 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past