MAURY USCG vessel records Sign in
← All vessels

ZHEMCHUZHNYY BEREG

ZHEMCHUZHNYY BEREG is a 1977 freight ship. The Coast Guard has recorded 3 inspections in 1996, along with 42 deficiencies and 1 operational control.

Records in 1996. Most recent: inspection, 7 October 1996.

Built
1977
Last inspected
7 October 1996
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7712236 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
422343
Flag
RUSSIA
—
Maury page id
psix-422343

Inspections, by type

…with no type recorded3
Years with a record 1 calendar year (1996)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12374 - Regulatory (Subpart C or D), Gross Ton
3967 - Regulatory (Subpart C or D), Net Ton
9583 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

7 October 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 721075
30 September 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 395818
30 September 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 395888

Deficiency record · 42

Engineering
Issued 30 September 1996 Resolved
RENEW AS ORIGINAL THE DETERIORATED SEA WATER PIPE FOR THE MAIN ENGINE LUBE OIL COOLER LOCATED ON THE STBD SIDE LOWER LEVEL OF THE ENGINE ROOM OUTBOARDOF THE MAIN ENGINE._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Accommodation/Occupational Safety
Issued 30 September 1996 Resolved
RENEW/REPAIR ALL WASTED DECK PLATING/DECK SUPPORT FRAMING THROUGHOUT THE LOWER LEVEL OF THE ENGINE ROOM._x001C_ SWEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Engineering
Issued 30 September 1996 Resolved
RENEW AS ORIGINAL THE DETERIORATED SEA WATER COOLING PIPING SERVICING THE #2 GENERATOR LUBE OIL COOLER._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Accommodation/Occupational Safety
Issued 30 September 1996 Resolved
RENEW AS ORIGINAL THE DETERIORATED FRESH WATER PIPING ON THE SEAL TANK LOCATED BELOW THE SEAL WATER TANK ON THE STBD SIDE AFT OF THE #4 GENERATOR._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Engineering
Issued 30 September 1996 Resolved
RENEW AS ORIGINAL THE DETERIORATED 2" FRESH WATER PIPE SERVICING THE BOILERLOCATED ON THE PORT SIDE OF THE GENERATOR FLATS UPPER LEVEL._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Accommodation/Occupational Safety
Issued 30 September 1996 Resolved
RENEW ALL DETERIORATED/MISSING GUARD RAILS LOCATED ON THE AFT FORECASTLE _x001C_ SEE ICLL 66 REG 25
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Accommodation/Occupational Safety
Issued 30 September 1996 Resolved
RENEW/REPAIR ALL DETERIORATED VENTILATORS AND VENT CLOSURES ON THE STBD FORECASTLE (5) FROM FRAME 170-180_x001C_ SEE SOLAS 60 II/38
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 30 September 1996 Resolved
RENEW/REPAIR THE DETERIORATED FWD AND AFT ACCESS HATCHES TO THE #2 EVAPORATOR LOCATED IN THE BOILER ROOM._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 13 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 30 September 1996 Resolved
RENEW/REPAIR THE WASTED DECK PLATING/DECK SUPPORT FRAMING THROUGHOUT THE EMERGENCY FIRE PUMP ROOM._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 30 September 1996 Resolved
RENEW AS ORIGINAL THE DETERIORATED BALLAST WATER PIPING LOCATED ON THE PORTSIDE LOWER LEVEL OF THE ENGINE ROOM ABOVE THE #1 FIRE PUMP._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 13 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 30 September 1996 Resolved
RENEW THE CLOSURE DOGS ON THE WATERTIGHT HATCH LOCATED ON THE PORT SIDE OF THE #2 DECK HOUSE_x001C_ SEE ICLL 66 REG 16
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 30 September 1996 Resolved
RENEW THE WEATHERTIGHT DOOR LOCATED ON THE PORT SIDE OF THE #2 DECK HOUSE._x001C_SEE SOLAS 60 II/17
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 30 September 1996 Resolved
RENEW/REPAIR DAMAGED/BUCKLED SIDE SHELL FRAMING/PLATING LOCATED ON THE PORTSIDE OF THE MAIN DECK IN WAY OF FRAMES 145 THRU 160._x001C_ SEE ICLL 66 REG 25
Condition: Unknown
Due 13 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 30 September 1996 Resolved
SERVICE THE PORTABLE FIRE EXTINGUISHERS LOCATED IN THE #1 DECK HOUSE ELECTRICAL SPACE._x001C_ SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 30 September 1996 Resolved
RENEW/REPAIR THE DETERIORATED WATERTIGHT DOORS IN WAY OF FORKLIFT_x001C_ STORAGE SPACE ON FORECASTLE._x001C_ SEE ICLL 66 REG 12
Condition: Unknown
Due 13 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 30 September 1996 Resolved
RENEW/REPAIR ALL DETERIORATED/MISSING VENTILATION CLOSURES THROUGHOUT THE VESSEL._x001C_ SEE SOLAS 60 II/38
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Electrical
Issued 30 September 1996 Resolved
PROVE THE PROPER OPERATION OF ALL DECK LIGHTING SYSTEMS THROUGHOUT THE VESSEL._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Lifesaving
Issued 30 September 1996 Resolved
PROVIDE 56 LIFEJACKETS IN A SERVICABLE CONDITION._x001C_ SEE SOLAS 74 AMENDED III/19.2
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 30 September 1996 Resolved
REPAIR ALL HOLES AND DETERIORATED AREAS OF THE GALLEY BULKHEAD.
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 30 September 1996 Resolved
REMOVE ALL OIL AND OILY RESIDUE FROM THE ENGINE ROOM BILGES, GENERATOR FLATS, AND MACHINERY THROUGHOUT THE ENGINE ROOM._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 November 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 30 September 1996 Resolved
SURVEY THE MAIN CARGO DECK AND RENEW ALL DETERIORATED DECK PLATING, DECK FRAMING, AND STIFFENERS._x001C_ SEE SOLAS 60 II/36
Condition: Unknown
Due 12 November 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 30 September 1996 Resolved
Renew as original the deteriorated sea water pipe for the air compressor system overboard located on the stbd. side lower level of the engine room outboard and aft of the main engine coolers (next to fire hose reel)'See SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Accommodation/Occupational Safety
Issued 30 September 1996 Resolved
RENEW AS ORIGINAL THE DETERIORATED FRESH WATER PIPING LOCATED BELOW THE FRESH WATER SERVICE TANK ON THE GENERATOR FLATS IN THE ENGINE ROOM._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Fire Fighting
Issued 30 September 1996 Resolved
RENEW THE DETERIORATED FIRE HOSE LOCATED ON THE PORT SIDE MAIN DECK FWD OF THE #4 CARGO HOLD._x001C_ SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Fire Fighting
Issued 30 September 1996 Resolved
RENEW THE DETERIORATED FIRE HOSES LOCATED ON THE PORT AND STBD BOAT DECK._x001C_ SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Fire Fighting
Issued 30 September 1996 Resolved
RENEW THE DETERIORATED FIRE NOZZLE LOCATED ON THE STBD POOP DECK._x001C_ SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Accommodation/Occupational Safety
Issued 30 September 1996 Resolved
RENEW ALL DETERIORATED GUARD RAILS AND SUPPORT BRACKETS LOCATED ON TOP OF THE #2 DECK HOUSE._x001C_ SEE ICLL 66 REG 25
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Fire Fighting
Issued 30 September 1996 Resolved
RENEW VALVE STEM HANDLE FOR THE FIRE STATION LOCATED ON THE CENTERLINE FWD OF THE MAIN SUPERSTRUCTURE._x001C_ SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Fire Fighting
Issued 30 September 1996 Resolved
RENEW/REPAIR THE FROZEN/INOPERABLE FIRE HYDRANT LOCATED ON THE STBD SIDE FWD OF THE MAIN SUPERSTRUCTURE._x001C_ SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Lifesaving
Issued 30 September 1996 Resolved
PROVE THE PROPER OPERATION OF THE PORT LIFEBOAT ENGINE WHILE LIFEBOAT IS INWATER. REPAIR EXHAUST LEAK IN BOAT._x001C_ SEE SOLAS 74 AMENDED III/19.2
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 30 September 1996 Resolved
RENEW THE DETERIORATED WATERTIGHT HATCH IN WAY OF VENTILATION MOTOR ENCLOSURE LOCATED ON TOP OF THE #3 DECK HOUSE._x001C_ SEE SOLAS 60 II/36
Condition: Unknown
Due 13 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 30 September 1996 Resolved
REPAIR THE DETERIORATED BULKHEAD LOCATED ON THE STBD AFT BOAT DECK._x001C_ SEE SOLAS 60 II/36
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Engineering
Issued 30 September 1996 Resolved
PROVE THE PROPER OPERATION OF THE VESSELS OILY WATER SEPERATOR AS PER THE 15PPM REQUIREMENT ON THE VESSELS OIL POLLUTION PREVENTION (IOPP) CERTIFICATE._x001C_ SEE MARPOL 73/78 AX. I/16 AND 33 C.F.R. 155.380(b)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Fire Fighting
Issued 30 September 1996 Resolved
PERFORM A SATISFACTORY FIRE AND ABANDON SHIP DRILL IN THE PRESENCE OF A COAST GUARD INSPECTOR._x001C_ SEE SOLAS 74 AMENDED III/18.3.4-3.9 AND 18.3.10-3.13
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 30 September 1996 Resolved
REPAIR/RENEW THE DETERIORATED VENTILATION PUMP ENCLOSURE LOCATED ON TOP OF THE #3 DECK HOUSE._x001C_ SEE SOLAS 60 II/36
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Engineering
Issued 30 September 1996 Resolved
Renew as original the deteriorated sea water piping for the main engine cooler on the stbd side lower level of the engine room outboard of the #3 fire pump._x001C_ See SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Fire Fighting
Issued 30 September 1996 Resolved
REPAIR/RENEW LEAKING FIREMAIN VALVE FOR SUPPLY TO #3 FIRE PUMP LOCATED ON THE STBD SIDE LOWER LEVEL OF THE ENGINE ROOM FWD OF THE #3 FIRE PUMP BELOW DECK PLATES._x001C_ SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Engineering
Issued 30 September 1996 Resolved
RENEW AS ORIGINAL THE DETERIORATED SEA WATER PIPING FOR THE #2 MAIN SEA WATER PUMP LOCATED ON THE DISCHARGE SIDE FWD OF THE MAIN SEA WATER PUMP STBD SIDE LOWER LEVEL OF THE ENGINE ROOM._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 30 September 1996 Resolved
Repair/renew main sea chest isolation valve located on the stbd side lower level of the engine room on inboard side of sea chest (valve is missing valve stem)_x001C_ see SOLAS 74 Amended I/11(a)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Engineering
Issued 30 September 1996 Resolved
RENEW AS ORIGINAL THE DETERIORATED SEA WATER PIPING FOR AUXILLARY SEA WATERCOOLING LOCATED ON THE STBD SIDE LOWER LEVEL OF THE ENGINE ROOM OUTBOARD OFTHE MAIN ENGINE LUBE OIL COOLERS._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 13 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 30 September 1996 Resolved
INSTALL BLANK FLANGE ON FIRE MAIN PIPING FROM THE #2 FIRE PUMP WHERE SYSTEMHAS BEEN ISOLATED FROM THE COUNTER MEASURE WASH DOWN SYSTEM LOCATED ON THE PORT SIDE LOWER LEVEL OF THE ENGINE ROOM FWD OF THE #1 FIRE PUMP._x001C_ SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996
Deck/Cargo
Issued 30 September 1996 Resolved
RENEW AS ORIGINAL THE DETERIORATED SEA WATER PIPING FOR THE PROVISION AIR COMPRESSORS LOCATED ON THE STBD SIDE LOWER LEVEL OF THE ENGINE ROOM OUTBOARD OF THE MAIN ENGINE LUBE OIL COOLERS GOING TO OVERBOARD VALVE._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 October 1996
Resolved 15 October 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.