Records from 2016 to 2026. Most recent: inspection, 6 August 2026.
Inspection history · 15
6 August 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8461959
16 July 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8437492
17 July 2025
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8182515
8 July 2024
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7941717
8 July 2024
Administrative Inspection · DAPI Audit
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7960723
19 July 2023
Administrative Inspection · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7744917
19 July 2022
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7510040
12 July 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7263537
10 June 2021
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7215566
16 July 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7019269
28 June 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6729057
17 July 2018
COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6465448
5 March 2018
Liferaft Servicing
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6367190
20 July 2017
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6304408
14 July 2016
Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5939241
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 July 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Both 12V batteries installed on-board from 2019 were no longer serviceable, replace both 12V batteries.
46 CFR 183.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2024
Resolution: Both batteries were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 July 2024
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. The life raft hydrostatic release was installed incorrectly, properly install hydrostatic release unit.
46 CFR 180.130(a)(2)
Action required: 10 - Deficiency Rectified
Resolved 8 July 2024
Resolution: Hydrostatic release was properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2024
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. The stowage container for life jackets was marked for 20 adult life jackets but only 18 adult life jackets are required, update stowage container quantity marking.
46 CFR 185.604(f)
Action required: 10 - Deficiency Rectified
Resolved 8 July 2024
Resolution: Stowage container markings were updated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2024
Resolved
Each life jacket carried on board the vessel must be
marked IAW 46 CFR 185.604: ship's name. The ship's name
was not marked on 02 lifejackets, mark life jackets.
46 CFR 180.71(e)
Action required: 10 - Deficiency Rectified
Resolved 8 July 2024
Resolution: Lifejackets were properly marked.
Engineering › Gasoline Engine (propulsion) › Battery (4 cycle)
Issued 14 July 2016
Resolved
Prove proper operation of port engine prior to operating (46CFR182.01-5).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 2 August 2016
Resolution: Observed sat op of port engine.
Engineering › Gasoline Engine (propulsion) › Hose, Cooling System (4 cycle)
Issued 14 July 2016
Resolved
Make permanent & proper repairs to stbd engine cooling expansion tank prior to operating (46CFR182.01-5).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 26 July 2016
Resolution: Rcvd email w/ pic indicating new expansion tank installed.
Lifesaving › Inflatable Liferafts › Weak Link
Issued 14 July 2016
Resolved
Make proper connection between life raft painter & hydrostatic release unit prior to operating.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 26 July 2016
Resolution: Rcvd email w/ pic indicating proper connection btwn LR & HRU.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 14 July 2016
Resolved
Provide BII portable fire extinguisher prior to operating (46CFR181.30-1).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 26 July 2016
Resolution: Rcvd email w/ pic indicating BII extinguisher mounted.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 July 2016
Resolved
Conduct man overboard & fire drills in presence of marine inspector prior to operating (46CFR176.810).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 2 August 2016
Resolution: Observed sat MOB & fire drill.