Records from 1985 to 1989. Most recent: inspection, 1 November 1989.
Documentation record
Registered dimensions (L × B × D)61.5 ft × 14.9 ft × 8.6 ft
Registered tonnagegross 64 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJULIUS PETERSEN · NYACK, NY, UNITED STATES · built 1946
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portVIRGINIA BEACH, VA
Trade endorsementsRecreational
DocumentationNo Operation - PM · issued 10 July 1991
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Net Ton
64 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
1 November 1989
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 975769
23 March 1989
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1038774
19 May 1988
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1341442
22 April 1988
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1032584
8 May 1987
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1334387
7 May 1987
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1022968
5 May 1987
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1328023
9 April 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1328557
19 September 1986
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1020842
27 March 1986
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1305055
10 July 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1285973
21 March 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 984166
Construction/Loadline
Issued 23 March 1989
Resolved
MAKE THE BULKHEAD BETWEEN THE ENGINEROOM AND CREW BERTH VAPOR TIGHT.
Condition: Unknown
Due 23 March 1989
Resolved 23 March 1989
Construction/Loadline
Issued 23 March 1989
Resolved
FIX THE STEP ON THE LADDER TO THE HEAD.
Condition: Unknown
Due 23 March 1989
Resolved 23 March 1989
Construction/Loadline
Issued 22 April 1988
Resolved
PROPERLY REPAIR DAMAGED FLOOR AND FRAME STIFFENERS IN FOREPEAK.
Condition: Unknown
Due 22 April 1988
Resolved 22 April 1988
Unknown
Issued 5 May 1987
Resolved
PROPERLY MARK THE EMERGENCY ESCAPE FROM THE ACCOMADATION AREA.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Electrical
Issued 5 May 1987
Resolved
REPAIR THE EMERGENCY LIGHTS IN THE PILOTHOUSE AND ACCOMADATION AREA.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Fire Fighting
Issued 5 May 1987
Resolved
SERVICE THE DISCHARGED BI FIRE EXTINGUISHER IN THE ACCOMADATIONS AREA AND THE BII FIRE EXTINGUISHER IN THE MACHINERY SPACE.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Lifesaving
Issued 5 May 1987
Resolved
PROVIDE AN APPROVED TYPE LIFE RING TO REPLACE THE ONE PRESENTLY INSTALLED ON THE VESSEL.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Fire Fighting
Issued 5 May 1987
Resolved
PROVIDE A HAND PORTABLE FIRE PUMP OF AT LEAST 5 GPM CAPACITY EQUIPPED WITH SUFFICIENT SUCTION AND DISCHARGE HOSES.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Electrical
Issued 5 May 1987
Resolved
REPAIR OR REPLACE THE INDEPENDENT SHIP'S SERVICE GENERATOR AND PROVE PROPEROPERATION OF SAME.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Lifesaving
Issued 5 May 1987
Resolved
PROVIDE FOUR ADULT APPROVED LIFEJACKETS. THE VESSEL IS NOT TO CARRY MORE THAN 45 ADULT PASSENGERS UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Navigation
Issued 5 May 1987
Resolved
PROVIDE OPERATION OF ALL ELECTRONIC NAVAGATION AND RADIO EQUIPMENT. INFORMCOAST GUARD INSPECTOR AS TO WHY POWER WAS LOST ON THESE SYSTEMS.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Construction/Loadline
Issued 5 May 1987
Resolved
REPAIR OR REPLACE THE PORT MAIN ENGINE COOLING WATER SUCTION THROUGH HULL FITTING (SEACOCK).
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Construction/Loadline
Issued 5 May 1987
Resolved
MAKE AVAILABLE FOR INSPECTION ALL THROUGH HULL FITTINGS AND SEA VALVES FOR POSSIBLE WASTAGE FROM ELECTROLISIS.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Electrical
Issued 5 May 1987
Resolved
PROVIDE A SUITABLE COVER FOR THE BATTERY BOX IN THE ENGINEROOM. THE COVER MUST CONFORM TO REGULATIONS; I.E. VENT HOLES IN COVER.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Lifesaving
Issued 5 May 1987
Resolved
PROVIDE 100' PAINTER ON THE BUOYANT APPRATUS AND LIFEFLOAT.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987