MAURY USCG vessel records Sign in
← All vessels

MIDNIGHT EXPRESS

MIDNIGHT EXPRESS is a 1964 freight ship. The Coast Guard has recorded 43 inspections since 1995, most recently in February 2018, along with 83 deficiencies — 2 with no resolution recorded — and 12 operational controls.

Records from 1995 to 2018. Most recent: inspection, 22 February 2018.

Built
1964
Last inspected
22 February 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8732025 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
422646
Flag
PANAMA
—
Maury page id
psix-422646

Inspections, by type

…with no type recorded24
…past their stated due date2
Years with a record 15 calendar years (1995–2018)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it137 - Regulatory (Subpart C or D), Gross Ton
41 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 43

22 February 2018 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6359283
23 September 2010 CCSSC Examination · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3854287
7 February 2010 PII Safety Exam · CCSSC Examination · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3673314
6 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3658148
18 March 2009 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3435532
31 January 2009 PII Safety Exam · ISPS II Exam · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3403030
23 January 2008 ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3134696
2 July 2007 MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2980923
15 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2856003
15 January 2007 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2856122
18 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2716884
23 May 2006 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2656459
4 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2640356
1 November 2005 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2526050
27 June 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2405110
18 January 2005 Deficiency Check · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2276386
28 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2055781
27 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2059635
25 February 2004 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2013108
10 February 2004 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2003569
13 November 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1947524
5 September 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1898156
25 August 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1886945
17 June 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1820153
17 June 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1820630
2 May 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1784901
2 May 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1785028
29 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1764832
17 March 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1758252
12 February 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1743391
6 November 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1702116
16 September 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1675933
28 August 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1667550
17 October 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 294741
13 September 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 293456
1 March 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 287664
21 August 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 281335
7 August 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 418830
7 June 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 392061
9 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 204731
9 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 530228
9 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 765321
4 April 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 377030

Deficiency record · 83

Personnel › Certificates/Documents/Licenses › License, Master
Issued 21 September 2010 Resolved
Masters license and endorsement were expired. Vessel is not manned in accordance with Safe Manning Certificate. Vessel must be manned in accordance with Safe Manning Certificate prior to departure. CCSS 1.7 STCW 95 I/4 and I/4
Action required: 705 - Other - as specified
Due 23 September 2010
Resolved 30 September 2010
Resolution: New Master was employed on the vessel.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 21 September 2010 Resolved
Vessel need to provide embarkation ladder prior to leaving port. CCSS4.10.1.2
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2010
Resolved 30 September 2010
Resolution: Flag state exempted vessel from rescue boat carriage requirement.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 21 September 2010 No resolution recorded
Vessel need to provide spare charges for every portable fire extinguisher prior to leaving port CCSS 3.6.6
Action required: 15 - Rectify deficiencies by next port
Due 23 November 2010 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 September 2010 Resolved
Remove all non approved bulbs from navigational lighting prior to leaving port. CCSS I.11
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2010
Resolved 30 November 2010
Resolution: Corrected.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 21 September 2010 No resolution recorded
Vessel do not have a rescue boat onboard. Provide prior to leaving port IAW CCSS 4.4.3. Flag issued exemption.
Action required: 15 - Rectify deficiencies by next port
Due 23 September 2010 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Governor
Issued 21 September 2010 Resolved
#2 ship service generator governor control is wire to hold the fuel control to run position. Make permanent repairs to generator to ensure generator will shut down automatically.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2010
Resolved 30 September 2010
Resolution: Corrected.
Construction/Loadline › Structures › Machinery Space Opening
Issued 21 September 2010 Resolved
Engine room ventilation closures are not able to open or close. Make permanent repairs to closure. CCSS 2.7.5
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2010
Resolved 30 September 2010
Resolution: Corrected.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle, Spare
Issued 21 September 2010 Resolved
SCBA must have a spare charge and maintain to the Code. CCSS 3.11.2.2.2
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2010
Resolved 30 September 2010
Resolution: Corrected.
Navigation › Piloting/Steering › Marine Charts
Issued 21 September 2010 Resolved
Vessel need to provide updated charts and publications. CCSS 6.2.6
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2010
Resolved 26 September 2010
Resolution: Provided receipts for required charts and publications
Engineering › Bilge Water Management System › Pump
Issued 21 September 2010 Resolved
Vessel need to install one power driven pump connected to bilge main. CCSS2.18
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2010
Resolved 30 September 2010
Resolution: Pump operational. Unable to operationally test suction/discharge because pump discharged directly overboard.
Stability › Watertight Integrity › General
Issued 21 September 2010 Resolved
All 4 water tight doors on main deck need to meet the water tight requirements IAW CCSS Code for design, operations, installation, and closure. CCSS 2.7.5
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2010
Resolved 30 September 2010
Resolution: Corrected.
Engineering › Lubricating Oil Service System › Flange
Issued 7 February 2010 Resolved
Port side generator is leaking lube oil due to a wasted flange in the lube oil system. Vessel is to repair the the leak withing 30 days.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 March 2010
Resolved 6 May 2010
Resolution: flange has been replaced.
Fire Fighting › International Shore Connection › Flange
Issued 7 February 2010 Resolved
International Shore Connection on board is wasted and missing gasket. Vessel is to replace connection within 30 days.
Action required: 705 - Other - as specified
Due 7 March 2010
Resolved 6 May 2010
Resolution: Company has purchases and new International Shore connection and has it on board.
Communications › Radio Communications › EPIRB
Issued 7 February 2010 Resolved
EPIRB on bridge wing is mounted underneath an over hang. Vessel is to re-mount EPIRB in a float-free position withing 30 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 March 2010
Resolved 6 May 2010
Resolution: recieved photo of new EPRIB placement.
Personnel › Manning/Qualifications › Person in Charge of COW Operations
Issued 7 February 2010 Resolved
Vessel has a valid DOC for danergous cargo. No personnel on board had proof of Dangerous cargo handling training. Vessel is to rpovide proof of Dangerous cargo handling training for atleast on person onboard prior to conducting cargo operations with Dangerous cargo.
Action required: 705 - Other - as specified
Due 7 February 2010
Resolved 1 March 2010
Resolution: recieved proof of tdangerous cargo handling training for Crew member.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 23 January 2008 Resolved
Master of vessel does not have valid STCW endorsement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2008
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 1 November 2005 Resolved
Emergency Fire Pump is not operational. Prove proper operation of emergency fire pump
Due 2 November 2005
Resolved 2 November 2005
Navigation › Piloting/Steering › Swing Meter
Issued 18 January 2005 Resolved
Replace/ Repair rudder angle indicator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2005
Construction/Loadline › Structures › Door
Issued 18 January 2005 Resolved
Hole above watertight door leading to berthing; provide repair proposal to the satisfaction of the flag state.
Due 1 February 2005
Resolved 18 January 2005
Construction/Loadline › Structures › Door
Issued 18 January 2005 Resolved
Hole and wasted below watertight door leading to galley. Provide repair proposal to satisfaction of flag state.
Due 1 February 2005
Resolved 18 January 2005
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 January 2005 Resolved
Door between galley and berthing not an "A" class door. Properly install door meeting "A" class requirements to satisfaction of flag state.
Due 27 June 2005
Resolved 2 November 2005
Fire Fighting › Structural - A Class Divisions › Special Category Spaces
Issued 18 January 2005 Resolved
Access hatch between galley and pilot house not an "A" class boundary. Install "A" class closure to satifaction of flag state.
Due 1 February 2005
Resolved 18 January 2005
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 18 January 2005 Resolved
STBD shaft tube is holed and wasted. Submit repair proposal to Sector Miami via fax.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2005
Resolved 29 April 2005
Resolution: Recieved survey report.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 18 January 2005 Resolved
PORT shaft stern tube is wasted. Provide guaging report to Sector Miami via fax.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2005
Fire Fighting › Fire Pumps › Arrangement
Issued 18 January 2005 Resolved
Pipe coupler for fire pump inlet is covered with fiberglass. Remove coaming and properly repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2005
Construction/Loadline › Structures
Issued 10 February 2004 Resolved
Properly repair mast where welding has been seperated at base support. LEGACY COMPONENT DESC: MAST
Due 17 February 2004
Resolved 26 February 2004
Navigation › Collision/Grounding Avoidance
Issued 10 February 2004 Resolved
Permanently affix deflectors for port and stbd navigation lights. LEGACY COMPONENT DESC: Navigation Lights
Due 17 February 2004
Resolved 26 February 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 10 February 2004 Resolved
Properly repair ladder to flying bridge where it is not secured at the top (AFT END of ladder).
Due 17 February 2004
Resolved 26 February 2004
Electrical › Electric Supply System (service)
Issued 10 February 2004 Resolved
Properly remove or terminate into electrical box all spliced or dead ended wiring throughout engine room.
Due 26 February 2004
Resolved 10 February 2004
Engineering
Issued 25 August 2003 Resolved
Vessel missing remote shut off valve on fuel line. LEGACY COMPONENT DESC: Remote valves for fuel lines
Due 5 September 2003
Resolved 5 September 2003
Lifesaving
Issued 25 August 2003 Resolved
Vessel has expired battery on EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2003
Deck/Cargo › Holds/Tanks
Issued 12 February 2003 Resolved
Replace gasket material for cargo hatch to ensure water tight integrity. LEGACY COMPONENT DESC: Hatch
Due 28 February 2003
Resolved 17 March 2003
Construction/Loadline
Issued 12 February 2003 Resolved
Replace gasket material on Port and Stbd. engine room ventilation openings and ensure watertight integrity.
Due 28 February 2003
Resolved 17 March 2003
Construction/Loadline
Issued 12 February 2003 Resolved
Make proper repairs to Starboard Engine Room hatch and ensure watertight integrity.
Due 28 February 2003
Resolved 12 February 2003
Documentation
Issued 12 February 2003 Resolved
Provide complete surveyors report from vessels latest drydock in January 2003.
Due 28 February 2003
Resolved 17 March 2003
Construction/Loadline
Issued 12 February 2003 Resolved
Make proper repairs to aft bulkhead of deck stores near the bottom of the watertight door. Currently, the bulkhead is wasted through showing daylight inside.
Due 28 February 2003
Resolved 17 March 2003
Engineering
Issued 12 February 2003 Resolved
Provide proper storage container for battery in Engine Room in way of switchboard.
Due 28 February 2003
Resolved 17 March 2003
Construction/Loadline › Structures
Issued 6 November 2002 Resolved
Replace wooden insert on the aft bulkhead of the pilothouse with proper steel insert, in accordance with CCSSC 3.15, to the satisfaction of the Flag State and provide Flag State report attesting that the proper repair was made, prior to January 31, 2003. LEGACY COMPONENT DESC: Superstructure
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 12 February 2003
Resolution: Replaced with steel insert.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 28 August 2002 Resolved
Hydrostatic releases are expired and liferafts are not properly mounted. Replace hydrostatic releases and mount liferafts properly prior to departure.
Due 28 August 2002
Resolved 28 August 2002
Construction/Loadline › Structures
Issued 28 August 2002 Resolved
Repair broken windows on the bridge to the satisfaction of the U.S. Coast Guard prior to 01 Sep 2002. LEGACY COMPONENT DESC: Superstructure
Due 1 September 2002
Resolved 13 September 2002
Construction/Loadline › Structures
Issued 28 August 2002 Resolved
Replace wooden insert on the aft bulkhead of bridge prior to 01 Oct 2002. LEGACY COMPONENT DESC: Superstructure
Action required: 705 - Other - as specified
Due 1 October 2002
Resolved 6 November 2002
Resolution: New requirement issued, spelling out what repair needs to be made.
Electrical › Electrical Distribution System (service)
Issued 28 August 2002 Resolved
Properly wire spotlight located atop the bridge to the satisfaction of the the USCG prior to 01 Sep 2002. LEGACY COMPONENT DESC: Wiring
Due 1 September 2002
Resolved 13 September 2002
Electrical › Electric Supply System (service)
Issued 28 August 2002 Resolved
Secure battery boxes tot he ship's generators prior to 01 Sep 2002. LEGACY COMPONENT DESC: Battery Installation
Due 1 September 2002
Resolved 13 September 2002
Electrical › Lighting (service)
Issued 28 August 2002 Resolved
Repair/replace lighting in aft steering. LEGACY COMPONENT DESC: Lighting Fixture
Due 1 September 2002
Resolved 13 September 2002
Construction/Loadline › Structures
Issued 28 August 2002 Resolved
Make permanent and proper repair to hole in deck between hatches to aft steering and aft void to the satisfaction fo the USCG. LEGACY COMPONENT DESC: Deck Plating
Due 1 September 2002
Resolved 13 September 2002
Construction/Loadline › Penetrations
Issued 28 August 2002 Resolved
Cable run penetration in pilothouse is leaking. Make permanent and proper reapiars. LEGACY COMPONENT DESC: Gasket
Due 1 September 2002
Resolved 13 September 2002
Navigation
Issued 13 September 2001 Resolved
Provide daylight signalling lamp.
Condition: Unknown
Due 18 September 2001
Resolved 13 September 2001
Electrical
Issued 13 September 2001 Resolved
Remove all exposed wiring throughout vessel; specifically the bridge and engine room.
Condition: Unknown
Due 18 September 2001
Resolved 13 September 2001
Lifesaving
Issued 13 September 2001 Resolved
Provide six (6) parachute flares, in accordance with CCSSC 4.13.
Condition: Unknown
Due 18 September 2001
Resolved 13 September 2001
Documentation
Issued 13 September 2001 Resolved
Provide annual inspection certificates for liferafts.
Condition: Unknown
Due 18 September 2001
Resolved 13 September 2001
Lifesaving
Issued 13 September 2001 Resolved
Provide posted operating/launching instructions for liferafts .
Condition: Unknown
Due 18 September 2001
Resolved 13 September 2001
Electrical
Issued 13 September 2001 Resolved
Provide emergency source of electrical power IAW CCSSC 2.34.5.
Condition: Unknown
Due 18 September 2001
Resolved 13 September 2001
Lifesaving
Issued 13 September 2001 Resolved
Conduct satisfactory abandon ship drill.
Condition: Unknown
Due 18 September 2001
Resolved 13 September 2001
Lifesaving
Issued 13 September 2001 Resolved
Remove all stored boxes from engine room.
Condition: Unknown
Due 13 September 2001
Resolved 13 September 2001
Fire Fighting
Issued 13 September 2001 Resolved
Provide bolts for international shore connection.
Condition: Unknown
Due 18 September 2001
Resolved 13 September 2001
Navigation
Issued 13 September 2001 Resolved
Provide operating instructions for steering gear in engine room and line diagram for engine room and bridge.
Condition: Unknown
Due 18 September 2001
Resolved 13 September 2001
Documentation
Issued 13 September 2001 Resolved
Provide annual survey for CCSSC; provide copy of certificate with endorsement.
Condition: Unknown
Due 18 September 2001
Resolved 13 September 2001
Fire Fighting
Issued 13 September 2001 Resolved
Conduct fire and abandon ship drills in the presence of USCG Marine_x001C_ Inspectors, next U.S. port call.
Condition: Unknown
Due 17 October 2001
Resolved 17 October 2001
Documentation
Issued 13 September 2001 Resolved
Provide licenses & crew documents on board.
Condition: Unknown
Due 13 September 2001
Resolved 13 September 2001
Navigation
Issued 13 September 2001 Resolved
Provide corrected charts and sailing directions.
Condition: Unknown
Due 18 September 2001
Resolved 13 September 2001
Documentation
Issued 13 September 2001 Resolved
Provide deviation table prior to next U.S. port.
Condition: Unknown
Due 18 September 2001
Resolved 13 September 2001
Documentation
Issued 13 September 2001 Resolved
Provide Safe manning document for vessel prior to departure.
Condition: Unknown
Due 13 September 2001
Resolved 13 September 2001
Navigation
Issued 21 August 2000 Resolved
Install a retaining pin in the starboard steering ram coupling.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Documentation
Issued 21 August 2000 Resolved
Update Muster List to indicate assignments for what additional emergency gear and equipment will be provided during abandon ship procedures, and by whom.
Condition: Unknown
Due 1 March 2001
Resolved 1 March 2001
Fire Fighting
Issued 21 August 2000 Resolved
Demonstrate adequate communications between all fire team and fire control personnel during a fire drill. Communication was marginal from bridge personnel to the crew, and between the fire party leader and the fire party.
Condition: Unknown
Due 1 March 2001
Resolved 1 March 2001
Lifesaving
Issued 21 August 2000 Resolved
Install a machinery guard for the drive belt on the air compressor located below the steering solenoid switches.
Condition: Unknown
Due 1 March 2001
Resolved 1 March 2001
Documentation
Issued 7 August 1998 Resolved
Provide full compliment of officers in accordance with Safe Maning Document. (In accordance with CCSSC Chapter 1.7)
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Fire Fighting
Issued 7 August 1998 Resolved
Make the emergency fire pump operable. (In accordance with CCSSC Chapter 3.3.7.1)
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Fire Fighting
Issued 7 August 1998 Resolved
Provide proper water pressure for main fire pump. (In accordance with CCSSC Chapter 3.3.1.1)
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Construction/Loadline
Issued 7 August 1998 Resolved
Provide receipts for bilge water diposal.
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Documentation
Issued 7 August 1998 Resolved
Provide Flag State report addressing discrepancy between S.M.D. and CCSSC about manning of machinery space.
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Fire Fighting
Issued 7 August 1998 Resolved
Provide proper fire extinguishing arrangement for U.M.S. (IAW CCSSC Chapter 3.10.4)
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Fire Fighting
Issued 7 August 1998 Resolved
Provide proper fires hoses. (IAW CCSSC Chapter 3.5.4)
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Engineering
Issued 7 August 1998 Resolved
Replace all rubber hoses for fuel with approved non-flammable material. (IAW CCSSC Chapter 3.19.6)
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Documentation
Issued 7 August 1998 Resolved
Provide proper Oil Transfer Procedures, prior to next U.S. bunkering.
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Fire Fighting
Issued 7 August 1998 Resolved
Provide fixed fire detection system for U.M.S. (IAW CCSSC Chapter 3.16.7)
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Deck/Cargo
Issued 4 April 1995 Resolved
PROVIDE STABILITY INFORMATION FOR VSL LOADING OR CONDUCT SALLYING TEST EACHVSL LOADING.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Accommodation/Occupational Safety
Issued 4 April 1995 Resolved
PROVIDE MEDICAL CERTIFICATES FOR ALL CREWMWMBERS.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Engineering
Issued 4 April 1995 Resolved
PROVIDE DOCUMENTATION FROM FLAG ADMINISTRATION OF VSLS TOTAL FUEL CAPACITY OR COMPLY WITH US REGULATIONS FOR VESSELS WITH CAPACITY OF 10,500 GALS OR MORE.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Navigation
Issued 4 April 1995 Resolved
PROVIDE DOCUMENTATION FROM FLAG ADMINISTRATION THAT VSL IS SUFFICIENTLY ANDEFFICIENTLY MANNED PRIOR TO DEPARTURE.
Condition: Unknown
Due 4 April 1995
Resolved 8 April 1995
Navigation
Issued 4 April 1995 Resolved
Provide 6 orange smoke signals.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Construction/Loadline
Issued 4 April 1995 Resolved
PROVIDE LABELS TO BILGE VALVES TO INDICATE WHICH SPAC THEY SERVICE.
Condition: Unknown
Due 4 April 1995
Resolved 8 April 1995
Navigation
Issued 4 April 1995 Resolved
Provide NOAA chart 26320 or equivilent.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995

Ownership record