Records from 1985 to 2023. Most recent: inspection, 19 July 2023.
Inspection history · 70
19 July 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7746470
17 July 2023
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7744503
28 October 2022
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7587221
28 June 2022
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7480012
22 September 2021
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7317784
23 September 2020
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7063678
6 December 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6868781
13 September 2019
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6811287
24 July 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6760832
6 September 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6533597
15 August 2018
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6513052
31 May 2018
Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6480950
15 June 2017
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6221090
1 June 2017
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6220737
18 May 2017
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6144052
22 August 2016
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5979737
13 July 2016
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5979981
28 August 2014
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4968607
18 June 2014
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4892093
14 May 2014
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4858653
19 May 2012
COI Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4315354
26 July 2011
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4096839
21 April 2009
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3469511
5 April 2009
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3446535
3 October 2008
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3353578
9 June 2008
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3231475
2 May 2008
Deficiency Check · Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3199301
11 April 2008
Examination of Repairs · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3219397
31 March 2008
Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3175596
28 March 2007
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2896913
15 August 2006
Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2749013
27 April 2006
Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2635445
5 May 2005
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2350146
16 April 2004
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2045380
23 April 2003
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1779559
10 April 2002
COI Inspection · Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1603566
28 June 2001
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1472707
21 May 2001
Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1068315
20 April 2000
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1369697
19 April 1999
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 804029
19 April 1999
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1421644
29 April 1998
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 790309
29 October 1997
Plan Review "T" Boat
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 781010
22 April 1997
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1091591
22 April 1996
Hull Examination · COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1077949
12 April 1996
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1080047
29 November 1995
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 882420
14 November 1995
Damage Survey
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 874840
11 November 1995
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 31841
12 September 1995
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1190497
30 May 1995
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 872875
12 April 1995
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 840027
10 February 1995
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 144209
16 May 1994
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 859885
14 April 1994
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 856561
22 February 1994
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 112605
16 April 1993
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1145199
16 April 1992
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1011180
16 May 1991
Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1219950
18 April 1991
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1230304
3 March 1991
Damage Survey
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 996203
20 April 1990
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 925276
22 April 1989
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1035372
2 August 1988
Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1344297
22 April 1988
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1342722
22 September 1987
Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1007749
24 April 1987
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1025122
6 August 1986
Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1307690
29 April 1986
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1308423
23 May 1985
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 983852
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 28 June 2022
Resolved
Up-river mid-body main deck fractured at base of bit, must be repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 5 July 2022
Resolution: repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 28 June 2022
Resolved
MOB davit cable frayed, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 5 July 2022
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 June 2022
Resolved
Mainland side MDE has minor oil leak on fuel injection pump. Lead mechanic will monitor weekly and train vessel crew how to monitor daily. Any degradation will be immediately reported to local OCMI.
Action required: 705 - Other - as specified
Due 28 October 2022
Resolved 25 October 2023
Resolution: Vessel is laid up, out of service, relocated to MSU Chicago fleet. See Inspection Activity 7746470 for details.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 22 September 2021
Resolved
Found MDE's with multiple oil leaks plus oil and coolant accumulated in the bilge. Found dry portions of the bilge to have heavy scale accumulation which could potentially clog bilge suction feet. Clean engines and investigate source of oil leaks. Remove oil, coolant, and rust scale from bilges to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2021
Resolved 5 October 2021
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 September 2020
Resolved
Port life ring plug is missing and grab line is not authorized. Replace ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 20 October 2020
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 July 2019
Resolved
Make permanent repairs to mainland side rake void structural members as marked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 6 December 2019
Resolution: Cropped and renewed effected metal.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 August 2018
Resolved
Provide proper marine type mounting bracket for Portable Fire Extinguisher next to main engineroom entrance on main deck , downriver side, before 29AUG2018, to satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 27 August 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 August 2018
Resolved
Access hatch to island end rudder room is not attached to the vessel, to be corrected before 29AUG2018, to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 27 August 2018
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 18 May 2017
Resolved
Clean oil, water, and debris from engine room bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 1 June 2017
Engineering › Fuel Oil Service System › Piping
Issued 18 May 2017
Resolved
Prior to operating ship service generator, determine source of fuel oil leaks, repair same and demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 1 June 2017
Engineering › Steering Gear System › Pump
Issued 18 May 2017
Resolved
Provide adequate support for hydraulic suction piping for Island end steering pump.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 1 June 2017
Electrical › Electric Supply System (service) › Cable
Issued 18 May 2017
Resolved
Power supply for 12 volt vital systems must be provided from two sources or a battery that is charged by the propulsion engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 15 June 2017
Electrical › Electric Supply System (service) › Cable
Issued 18 May 2017
Resolved
Provide voltmeter and ammeter for the AC electrical supply system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 15 June 2017
Stability › Watertight Integrity › General
Issued 18 May 2017
Resolved
Make engine hatch watertight over Mainland end main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 1 June 2017
Stability › Watertight Integrity › General
Issued 18 May 2017
Resolved
Replace deteriorated access scuttle for island end steering space by next drydocking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2018
Resolved 13 July 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 May 2017
Resolved
Secure batteries against shifting, secure battery boxes and covers on main engine cranking batteries.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 1 June 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 May 2017
Resolved
Clean corrosion from terminals on main engince cranking batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 1 June 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 May 2017
Resolved
Repair frayed propulsion system control cables/terminal ends in wheelhouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 1 June 2017
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 18 May 2017
Resolved
Provide current copy of inland navigation rules.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 1 June 2017
Navigation › Piloting/Steering › Marine Charts
Issued 18 May 2017
Resolved
Provide current charts for navigating area.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 1 June 2017
Resolution: cancelled
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 18 May 2017
Resolved
Post employee assistance program information in clear sight of employees.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 1 June 2017
Resolution: posted at employee break area and time clock in building on island landing.
Deck/Cargo › Cargo Stowage › General
Issued 18 May 2017
Resolved
Post signage for the carriage of hazardous materials on deck.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 15 June 2017
Documentation › Markings/Placards › Warning Signs
Issued 18 May 2017
Resolved
Post signage that requires pedestrians to be seated at all times within the designated passenger seating area.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 15 June 2017
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 18 May 2017
Resolved
The crew failed to demonstate adequate knowledge of the vessel and procedures for bilge pumping, recovery of helpless person from the water, and firefighting. Conduct required training and drill for all aspects of the emergency instructions and provide records of same.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 1 June 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 May 2017
Resolved
Demonstrate satisfactory drills for fire, man overboard recovery, abandon ship, dewatering.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 1 June 2017
Stability › Watertight Integrity › General
Issued 18 May 2017
Resolved
Replace missing dog adjusting screws on main engineroorm access watertight scuttle and demonstrate watertightness.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 1 June 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 May 2017
Resolved
Wipe excessive oil and dust residues from machinery, wiring, and other appurtenances in the machinery spaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 1 June 2017
Construction/Loadline › Structures › Rake
Issued 13 July 2016
Resolved
Wastage and broken welds in forward most void on main land side. Submit repair plan to repair marked areas for approval of OCMI.
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 18 May 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 July 2016
Resolved
Replace damaged child lifejackets (4 condemended). Restricted to 90 pax until replaced)
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 22 August 2016
Resolution: New life jackets placed on board
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 July 2016
Resolved
Post current most COI in wheel house
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 22 August 2016
Resolution: Latest certificate mounted on board
Engineering › Lubricating Oil Service System › Gauge
Issued 13 July 2016
Resolved
repair oil pressure gauge on island side of helm.
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 22 August 2016
Resolution: Oil gauge wiring and gauge replaced and works properly
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 13 July 2016
Resolved
Repair cable at mainland side throttle control at steering stand
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 18 May 2017
Electrical › Electric Supply System (service) › Battery Conductor
Issued 14 May 2014
Resolved
Provide means of disconnect for positive leads on main engine cranking battery banks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 18 June 2014
Electrical › Electric Generation Source (service) › Conductor
Issued 14 May 2014
Resolved
Provide means of disconnect for positive leads at generator engine cranking battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 18 June 2014
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 14 May 2014
Resolved
Provide overcurrent protection for positive conductors in engineroom and wheelhouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 18 June 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2014
Resolved
Provide metallic supports for wiring throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 18 June 2014
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 May 2014
Resolved
Electrical components in vehicle loading ramp system must be watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2014
Resolved 12 September 2014
Electrical › Electrical Distribution System (service) › Conductor
Issued 14 May 2014
Resolved
Provide an insulated netral conductor from source to the wheelhouse AC distribution panel to prevent accidental electrical shock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2014
Resolved 18 June 2014
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 14 May 2014
Resolved
Relocate 2 of the B-II fire extinguishers from inside the engineroom to a location outside and readily accessible to main deck entrances to the engine room. One B-II extinguisher must be kept below decks readily available to the engine room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 18 June 2014
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 14 May 2014
Resolved
Insulate all dry exhaust systems for all engines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2014
Resolved 12 September 2014
Fire Fighting › Means of Escape › Escape Route Signs
Issued 14 May 2014
Resolved
Engineroom escape must be marked "EMERGENCY EXIT - KEEP CLEAR"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2014
Resolved 18 June 2014
Engineering › Fuel Oil Service System › Valve
Issued 14 May 2014
Resolved
Remote fuel shut off vlaves must be marked with purpose and direction of closure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2014
Resolved 18 June 2014
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 14 May 2014
Resolved
Make fuel tank for Barbeau end secure in the tank bracket.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2014
Resolution: Tank was properly mounted and supported.
Construction/Loadline › Penetrations › Pipe Flange
Issued 14 May 2014
Resolved
Make all penetrations in the watertight bulkhead between engine rooms water tight.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 18 June 2014
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 May 2014
Resolved
One adult size and deteriorated, removed same from service, adequate number and type remain aboard.
Condition: Improper/Lack of Maintenance
Due 23 May 2014
Resolved 23 May 2014
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 May 2014
Resolved
Retroreflective markings faded on one child size PFD, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 23 May 2014
Resolved 23 May 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 May 2012
Resolved
Permanently wire air compressor into electrical system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 1 June 2012
Resolution: Air compressor was properly wired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 May 2012
Resolved
Remove wire nut and properly connect sensor wire to engine in the Neebish side engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 1 June 2012
Resolution: Proper connections were made.
Electrical › Electric Supply System (service) › Cable
Issued 19 May 2012
Resolved
Make repair to grounding connector in Neebish Engne Room battery box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 1 June 2012
Resolution: Grounding connector was repaired.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 19 May 2012
Resolved
Provide fire extinguisher servicing report.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 1 June 2012
Resolution: Servicing report was provided
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 May 2012
Resolved
Replace line from the lifering to the lifering light located adjacent to the pilot house.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2012
Resolution: Line was replaced with proper length and type.
Stability › Watertight Integrity › General
Issued 19 May 2012
Resolved
Make repairs to watertight bulkhead between engine rooms.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 1 June 2012
Resolution: Watertight integrity was repaired
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 May 2012
Resolved
Vessel operated with passengers with an expired Certificate of Inspection
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2012
Resolution: COI Inspection was conducted and a new COI was issued to the vessel.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 June 2008
Resolved
Repair/replace water light t oensure a leak free seal as per 46 CFR 180.70
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 14 June 2008
Resolution: New light installed.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 9 June 2008
Resolved
Replace crackes widow in bridge IAW 46 CFR 177.1070.
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 3 October 2008
Resolution: New window installed.
Fire Fighting › Fire Hoses › Condition
Issued 9 June 2008
Resolved
Replace fire hose due to numerous pin hole peaks as per 46 CFR 181.320.
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 14 October 2008
Resolution: New 50'' fire hose installed.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 2 May 2008
Resolved
Make all voids available for inspection prior to departure from DDX.
Action required: 705 - Other - as specified
Due 23 May 2008
Resolved 5 May 2008
Resolution: All internals inspected to satisfaction of attending marine inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 2 May 2008
Resolved
Provide report of bottom gauging results (UT shots) to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2008
Resolved 5 May 2008
Resolution: Report/results submitted. See attached documents.
Construction/Loadline › Penetrations › Gasket
Issued 2 May 2008
Resolved
Replace worn gasket material on all hatches as per 46 CFR 179.360 (a). 01Oct08 EUPTA informed SSM that all hatches are being replaced. Extended due date to 15Nov08.
Action required: 705 - Other - as specified
Due 15 November 2008
Resolved 8 April 2010
Resolution: New watertight hatches installed in vessels deck.
Construction/Loadline › Hull › Bottom Plating
Issued 31 March 2008
Resolved
Make permanent repairs to outboard strake IVO port side engine room escape hatch prior to the carriage of passengers during normal operation.
Action required: 705 - Other - as specified
Resolved 23 May 2008
Resolution: Vessel repaided during dry dock. See documents in DDX exam for crop and renew specifics.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 March 2007
Resolved
MAKE TRANSVERSE BULKHEADS WATERTIGHT ON NEEBISH SIDE OF FERRY BETWEEN THE STEERING COMPARTMENT AND FUEL TANK COMPARTMENT IN ACCORDANCE W/ 46CFR179.320(a)
Due 28 April 2007
Resolved 10 April 2007
Resolution: Plugged and welded bulkhead
Engineering › Lubricating Oil Service System › Hose
Issued 28 March 2007
Resolved
INSTALL CHAFFING GEAR ON OIL PRESSURE INDICATOR GAUGE ON BOTH NEEBISH AND BARBEAU MDE'S
Due 28 April 2007
Resolved 10 April 2007
Resolution: chaffing gear installed
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 March 2007
Resolved
STARBOARD RUNNING LIGHT ON BAREAU SIDE EXTINGUISHED. MAKE REPAIRS TO STARBOARD RUNNING LIGHT AND MAKE OPERATIONAL.
Due 28 April 2007
Resolved 29 April 2007
Resolution: REPLACED BULB AND TESTED LIGHT.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 28 March 2007
Resolved
REPLACE/ RENEW ALTERNATOR BELTS ON NEEBISH SIDE MDE.
Due 28 April 2007
Resolved 10 April 2007
Resolution: Replaced v-belts
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 August 2006
Resolved
Install retro-reflective tape on main deck life ring buoy IAW 46 CFR 180.70.
Condition: Unknown
Due 15 September 2006
Resolved 18 August 2006
Lifesaving › Lifebuoys
Issued 10 April 2002
Resolved
Replace deteriorated lifeline on main deck ring life buoy, using dark-colored or certified UV-resistant buoyant line. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Due 24 April 2002
Resolved 30 April 2002
Electrical › Electrical Distribution System (service)
Issued 10 April 2002
Resolved
Bundle and support electrical wiring on both main diesel engines, as to reduce risk of wires being chafed or entangled in engine accessories. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 24 April 2002
Resolved 30 April 2002
Electrical › Electrical Distribution System (service)
Issued 10 April 2002
Resolved
In all spaces below the main deck, bundle electrical wiring and install metallic supports no more than 24" apart. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 24 April 2002
Resolved 30 April 2002
Engineering › Fuel Oil Service System
Issued 10 April 2002
Resolved
Mark both remote fuel oil shut off valves for purpose and direction of closure. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 24 April 2002
Resolved 30 April 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 April 2002
Resolved
Provide a complete first aid kit. LEGACY COMPONENT DESC: Kit
Condition: Improper/Lack of Maintenance
Due 24 April 2002
Resolved 30 April 2002
Fire Fighting › Fire Main
Issued 10 April 2002
Resolved
Install check valves in discharge outlet piping for both engine-driven fire and bilge pumps, as dictated by good marine practice. LEGACY COMPONENT DESC: Valves
Condition: Design Flaw
Due 24 April 2002
Resolved 30 April 2002
Operations/Management › Drills/Instruction
Issued 10 April 2002
Resolved
Conduct crew training for emergency situations and provided written records of this training as required by 46 CFR Part 185, Sections .520 and .524. LEGACY COMPONENT DESC: Records
Condition: Improper/Lack of Maintenance
Due 10 May 2002
Resolved 23 April 2003
Operations/Management › Drills/Instruction
Issued 10 April 2002
Resolved
Conduct emergency drills for man-overboard and fire scenarios in the presence of a marine inspector, after conducting training and providing records as outlined in 46 CFR 185.520 and .524. See item #7 issued this date. LEGACY COMPONENT DESC: Emergency Drills
Due 10 May 2002
Resolved 23 April 2003
Navigation › Collision/Grounding Avoidance
Issued 10 April 2002
Resolved
Install a signaling whistle that is audible for a distance of at least 1 nautical mile and meets the standards described in Section 86.05(b) of Annex III of the Navigation Rules. LEGACY COMPONENT DESC: Ships Whistle
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 30 April 2002
Navigation
Issued 28 June 2001
Resolved
RUDDER QUADRANT DANGEROUSLY LOOSE FROM RUDDER STOCK, EXCESSIVE PLAY IN RUDDER ON ISLAND END. WORN KEY RPELACED, TESTED SATISFACTORY DURING INSPECTION.
Condition: Unknown
Due 8 August 2001
Resolved 8 August 2001
Electrical
Issued 28 June 2001
Resolved
MODIFY ELECTRICAL POWER SUPPLY TO PREVENT SHORE TIE CROSS-CONNECTION TO SHIP-SERVICE GENERATOR, ACCORDING TO PLANS APPROVED BY THE OCMI, PRIOR TO THE COMPLAINCE DATE. MEANWHILE, GENERATOR SHALL NOT BE OPERATED WITHOUT EXPRESS APPROVAL BY THE OCMI ON A CASE-BY-CASE BASIS.
Condition: Unknown
Due 28 July 2001
Resolved 8 August 2001
Construction/Loadline
Issued 28 June 2001
Resolved
PROVIDE SATISFACTORY PORTABLE BILGE PUMP, PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 28 July 2001
Resolved 8 August 2001
Electrical
Issued 28 June 2001
Resolved
PROVIDE CIRCUIT PROTECTION (FUSES) IN RADIO ELECTRICAL POWER SUPPLY CIRCUITS BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 28 July 2001
Resolved 8 August 2001
Navigation
Issued 28 June 2001
Resolved
REPAIR LEAKY DIRECTIONAL CONTROL VALVES IN HYDRAULIC SYSTEMS FOR BOTH STEERING RUDDERS BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 28 July 2001
Resolved 8 August 2001
Navigation
Issued 20 April 2000
Resolved
Replace steering ram bushing and remove excess movement for the island end of vessel prior to the compliance date.
Condition: Unknown
Due 15 May 2000
Resolved 1 June 2000
Deck/Cargo
Issued 20 April 2000
Resolved
Replace lowering cable for the island end loading ramp prior to the complaince date.
Condition: Unknown
Due 15 May 2000
Resolved 1 June 2000
Engineering
Issued 20 April 2000
Resolved
Mark direction of closure for the fuel shut-off valves (2) prior to the compliance date.
Condition: Unknown
Due 15 May 2000
Resolved 1 June 2000
Engineering
Issued 20 April 2000
Resolved
Replace control cable connections for both MDE's control cables prior to the compliance date.
Condition: Unknown
Due 15 May 2000
Resolved 1 June 2000
Lifesaving
Issued 20 April 2000
Resolved
Conduct a man-overboard drill prior to the compliance date.
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000
Electrical
Issued 19 April 1999
Resolved
REORGANIZE ELECTRICAL WIRING AND RE-FASTEN SAME PROPERLY IN ENGINEROOMS, INWAY OF ENGINEROOM ENTRANCE, AND IN WHEELHOUSE CONTROL CONSOLE BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 19 April 1999
Resolved 19 April 1999
Navigation
Issued 19 April 1999
Resolved
COMPLETE INSTALLATION OF PROPER MASTHEAD ANS STERN LIGHTS BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 19 April 1999
Resolved 19 April 1999
Lifesaving
Issued 19 April 1999
Resolved
PROVIDE BUOYANT LIFELINES ON RING LIFEBUOYS IN REPLACEMENT OF NYLON LINES BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 23 April 1999
Resolved 23 April 1999
Electrical
Issued 19 April 1999
Resolved
REPAIR MAIN ENGINE STARTING CABLE FOR "WEST END" MAIN ENGINE BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 19 April 1999
Resolved 19 April 1999
Navigation
Issued 29 November 1995
Resolved
Perform design modifications to current rudder installation to reduce further posibility of sheared rudder posts. Have proposed modification drawings approved and stamped by a licensed professional engineer, and install modifications at next scheduled credit drydock exam.
Condition: Unknown
Due 29 November 1995
Resolved 29 November 1995
Navigation
Issued 14 November 1995
Resolved
Perform design modifications to current rudder installation to reduce further possibility of sheared rudder posts. Have proposed modification drawings approved and stamped by a licensed professional engineer, and install modifications at next scheduled credit drydock exam.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Unknown
Issued 14 November 1995
Resolved
Fabricate and install a freeboard/draft indicating device that will allow freeboards and/or drafts to be read by operating personnel prior to departing the dock.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Construction/Loadline
Issued 12 April 1995
Resolved
Repair fractured welds between underdeck transverse frames and main deck plating
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Navigation
Issued 14 April 1994
Resolved
Provide sidelights that meet the requirements of the Inland Rules of the Road.
Condition: Unknown
Due 14 April 1994
Resolved 14 April 1994
Construction/Loadline
Issued 14 April 1994
Resolved
Repair all fractured underdeck transverse frames as marked by Coast Guard Inspector.
Condition: Unknown
Due 14 April 1994
Resolved 14 April 1994
Construction/Loadline
Issued 14 April 1994
Resolved
Repair fractures on main deck in way of access hatches at both ends of vessel.
Condition: Unknown
Due 14 April 1994
Resolved 14 April 1994
Construction/Loadline
Issued 14 April 1994
Resolved
Repair hole in main deck in way of overhead of #2 end fuel compartment.
Condition: Unknown
Due 14 April 1994
Resolved 14 April 1994
Engineering
Issued 18 April 1991
Resolved
Provide bilge suction capability for second compartments aft.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Engineering
Issued 18 April 1991
Resolved
Provide check valves in all bilge suction lines.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991