Records from 2013 to 2025. Most recent: inspection, 25 August 2025.
Inspection history · 17
25 August 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8217487
8 July 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8179611
27 August 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7977092
8 September 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7787522
1 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7523065
16 November 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7351759
16 June 2021
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7226847
14 June 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7224730
6 February 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7136812
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108370
12 June 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6974579
13 June 2019
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6713268
4 December 2018
Drydock Exam · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6591331
14 September 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6540535
14 August 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6240434
7 December 2016
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6054069
14 June 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5907364
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 August 2025
Resolved
An interconnected detection and alarm system must:
(1) Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217 (incorporated by reference, see 46 CFR 175.600);
(2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. MI observed berthing area smoke alarms did not interconnect with the bridge panel. Also, galley detection system had audible but no visual alarm.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2025
Resolved 6 October 2025
Resolution: Vessel installed interconnected system. MI verified all auidible and visual alarms activated when seperate zones were tested. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 August 2024
Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. MI found check valve in fire main system with leak.
46 CFR 181.15-1(c)(old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 2 September 2024
Resolution: Received pictures. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
Unless a splice is made by an insulated pressure wire connector listed by Underwriters Laboratories, Inc., it standard No. 45, Recommended Practice for on Shipboard, may be used. MI found twist lock wire connectors on engine RMP tachs. Port fwd and center MDE.
46 CFR 183.05-50(b)(2)(old T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 2 September 2024
Resolution: Received pictures. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 27 August 2024
Resolved
Installation shall be in accordance with 46 CFR 182.15-15. MI found lagging on exhaust pipes Port engine
FWD/AFT and STBD engine FWD wasted an needed repair.
46 CFR 182.20-15(old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 2 September 2024
Resolution: Received pictures. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
Additional control equipment and measuring instruments shall be provided as necessary to insure satisfactory operation of the generators. MI found "Power Available" lights on main switchboard inoperable.
46 CFR 183.10-5(g)(old T)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 2 September 2024
Resolution: Received pictures. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 August 2024
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. MI found remote start solenoid
for center engine's start air inoperable.
46 CFR 182.10-1(a)(old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 6 September 2024
Resolution: Received video of proper remote start solenoid operations. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 August 2024
Resolved
New installations of fire protection equipment on and existing vessel...must comply with the regulations in this part. MI found no Inspection report on for fire detection system on vessel.
Action required: 60 - Rectify deficiencies prior to movement
Due 27 September 2024
Resolved 27 August 2024
Resolution: Received report of service by TPO. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 September 2023
Resolved
At each inspection the fire fighting equipment shall be inspected. Found wasted piping IVO fire pump, above and below main deck. Repair / replace. OLD T Cite 46CFr 176.25-25(a)(1)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2023
Resolution: Accepted video evidence of repair / NDT. Reissued additional (705-c) 7 day deficiency requiring MI attendance to witness NDT.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 September 2023
Resolved
Ateach inspection the lifesaving equipment serviceability shall be checked. Found rotted tether line between all lifefloats. Replace. OLD-T cite: 46CFR 176.25-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2023
Resolved 13 September 2023
Resolution: Line replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 September 2023
Resolved
At each inspection the fire fighting equipment shall be inspected. Found wasted piping IVO fire pump, above and below main deck. Repair / replace. OLD T Cite 46CFr 176.25-25(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2023
Resolved 13 September 2023
Resolution: Witnessed repairs and NDT of system.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 September 2023
Resolved
Ateach inspection the lifesaving equipment serviceability shall be checked. Found name stencils faded on all life floats. Replace. OLD-T cite: 46CFR 176.25-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2023
Resolved 13 September 2023
Resolution: Replaced stenciling.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 June 2020
Resolved
Each battery without an expiration date indicated on it or for which operator does not have record of inspection must be replced during an annual inspection; Waterlights were expired; Replace expired waterlights prior to departure; To the satisfaction of OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2020
Resolved 16 June 2020
Resolution: Vessel rep acquired new waterlights for all lifefloats and ring buoy and removed expired waterlights.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 June 2020
Resolved
A vessel that is aground must display appropriate dayshape configuration; Vessel was missing 01 ball dayshape; Acquire 01 ball dayshape NLT 26JUN20; To the satisfaction of the OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2020
Resolved 16 June 2020
Resolution: Vessel rep acquired new ball dayshape.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 June 2020
Resolved
Inspection and operation of all watertight closures in the hull an decks must be of satisfactory condition; Gasket on watertight door between passenger area and main deck was wasted; Replace gasket prior to departure; To the satisfaction of the OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2020
Resolved 16 June 2020
Resolution: Vessel rep reinstalled new gasket material on watertight door.
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 13 June 2019
Resolved
VHF radio failed to operate on emergency power. Required as per 46 CFR 184.502 and 47 CFR 80.905(a)(3). Owner shall make repairs and provide evidence of VHF operation on emergency power.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 3 July 2019
Resolution: Cleared to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2019
Resolved
Main Diesel Engine #4 produce unsatisfactory amounts of exhaust during operation due to suspected deficient fuel injector. Owner shall provide evidence of satisfactory repairs and operation. Old T citation not listed in MISLE data base - 46 CFR 182.05-5(b), selected general New T reference
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 3 July 2019
Resolution: Cleared to satisfaction of MI.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 June 2019
Resolved
Quick acting watertight doors between engine compartment, generator compartment, and rudder compartment were not watertight. Owner shall tighten the dogs on the doors to create a watertight seal IAW 46 CFR 177.13-1.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 3 July 2019
Resolution: Cleared to satisfaction of MI.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 June 2019
Resolved
Rudder bushings on port and starboard rudder posts were wasted due to lack of maintenance and use. Owner shall replace the wasted bearings for both rudder posts.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 3 July 2019
Resolution: Cleared to satisfaction of MI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 June 2019
Resolved
1-2" of standing oil in bilges underneath and around Main Diesel Engine #3. Owner shall remove fire hazard in bilge by cleaning/removing oil from bilges. Old T cite - 46 CFR 176.25-50(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 3 July 2019
Resolution: Cleared to satisfaction of MI.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 13 June 2019
Resolved
Secondary Radar installed on bridge was inoperable. Vessel is not required to have radar installed but due to its installation, Owner shall either make satisfactory repairs or remove equipment. Good marine practice basis - 46 CFR 176.25-1(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 3 July 2019
Resolution: Cleared to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 June 2019
Resolved
Two (02) safety relief valves on port side air compressors were missing service tags/proof of servicing. Owner shall provide evidence of testing or replace relief valves IAW 46 CFR 61.10-5(i)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 3 July 2019
Resolution: Cleared to satisfaction of MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2019
Resolved
Starboard lube oil standpipe was missing ground connection to tank. Owner shall install proper ground for standpipe. Rectify deficiency within 30 days. Due date is 14 July 2019.
Old T cite - 46 CFR 183.01-5(a).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 3 July 2019
Resolution: Cleared to satisfaction of MI.
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 August 2017
Resolved
Conduct drills (MOB, Abandon Ship, Fire) with the crew to go underway to the satisfaction of the CG inspector prior to getting underway. Prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2017
Resolution: Ran abandon ship drill with full crew, all sat.