← All vessels
GLOBAL ABIGAIL
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Heartland District (CGD-H) · Other hulls named GLOBAL ABIGAIL
GLOBAL ABIGAIL is a 1995 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 1995, most recently in August 2025, along with 46 deficiencies and 1 casualty investigation in 2013.
Records from 1995 to 2025. Most recent: inspection, 25 August 2025.
- Built
- 1995
- Last inspected
- 25 August 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 46 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2013
Identity
1031030
8977390 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDF9465
422771
Flag
UNITED STATES
366748650, 368475130
Maury page id
psix-422771
Inspections, by type
…with no type recorded2
Years with a record
29 calendar years (1995–2025)
The 46 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)134.7 ft × 28.0 ft × 11.0 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)134.7 ft × 28.0 ft × 11.0 ft
ITC tonnagegross 241 / net 72
BuilderTOUPS WELDING SERVICE INC · PATTERSON, LA, UNITED STATES · built 1995
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 7 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it241 - Convention (Subpart B), Gross Ton
96 - Regulatory (Subpart C or D), Gross Ton
72 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
96 - Regulatory (Subpart C or D), Gross Ton
72 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ9883MMSI 368475130 · active · compulsorily equipped · granted 20 May 2026, expires 20 May 2036
WDF9465MMSI 366748650 · active · compulsorily equipped · granted 8 July 2021, expires 1 October 2031
WCX2736MMSI 366748650 · cancelled · voluntarily equipped · granted 20 January 2007, cancelled 6 January 2011 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 46
25 August 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8217487
8 July 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8179611
27 August 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7977092
8 September 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7787522
1 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7523065
16 November 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7351759
16 June 2021
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7226847
14 June 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7224730
6 February 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7136812
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108370
12 June 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6974579
13 June 2019
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6713268
4 December 2018
Drydock Exam · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6591331
14 September 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6540535
14 August 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6240434
7 December 2016
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6054069
14 June 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5907364
14 September 2015
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5721896
16 June 2014
COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4885911
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200129
13 October 2010
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3869323
1 September 2010
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3839790
25 February 2009
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3438469
1 May 2008
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3196741
23 May 2007
Re-Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2938507
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806495
28 June 2006
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2694056
16 June 2006
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2681548
3 May 2005
Examination of Repairs · Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2344444
14 February 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2292466
14 July 2004
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2132863
2 June 2003
Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1807965
12 May 2003
Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1791590
23 May 2002
COI Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1619816
22 May 2001
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425132
19 May 2000
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1439030
27 May 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381575
29 June 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793269
4 May 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1124462
13 June 1997
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398689
27 January 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1100746
9 December 1996
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1097671
7 June 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 875123
30 April 1996
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1083921
10 June 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 875889
9 June 1995
Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360241
Deficiency record · 46
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 August 2025
Resolved
An interconnected detection and alarm system must:
(1) Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217 (incorporated by reference, see 46 CFR 175.600);
(2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. MI observed berthing area smoke alarms did not interconnect with the bridge panel. Also, galley detection system had audible but no visual alarm.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 August 2024
Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. MI found check valve in fire main system with leak.
46 CFR 181.15-1(c)(old T)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
Unless a splice is made by an insulated pressure wire connector listed by Underwriters Laboratories, Inc., it standard No. 45, Recommended Practice for on Shipboard, may be used. MI found twist lock wire connectors on engine RMP tachs. Port fwd and center MDE.
46 CFR 183.05-50(b)(2)(old T)
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 27 August 2024
Resolved
Installation shall be in accordance with 46 CFR 182.15-15. MI found lagging on exhaust pipes Port engine
FWD/AFT and STBD engine FWD wasted an needed repair.
46 CFR 182.20-15(old T)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
Additional control equipment and measuring instruments shall be provided as necessary to insure satisfactory operation of the generators. MI found "Power Available" lights on main switchboard inoperable.
46 CFR 183.10-5(g)(old T)
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 August 2024
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. MI found remote start solenoid
for center engine's start air inoperable.
46 CFR 182.10-1(a)(old T)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 August 2024
Resolved
New installations of fire protection equipment on and existing vessel...must comply with the regulations in this part. MI found no Inspection report on for fire detection system on vessel.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 September 2023
Resolved
At each inspection the fire fighting equipment shall be inspected. Found wasted piping IVO fire pump, above and below main deck. Repair / replace. OLD T Cite 46CFr 176.25-25(a)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 September 2023
Resolved
Ateach inspection the lifesaving equipment serviceability shall be checked. Found rotted tether line between all lifefloats. Replace. OLD-T cite: 46CFR 176.25-20
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 September 2023
Resolved
At each inspection the fire fighting equipment shall be inspected. Found wasted piping IVO fire pump, above and below main deck. Repair / replace. OLD T Cite 46CFr 176.25-25(a)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 September 2023
Resolved
Ateach inspection the lifesaving equipment serviceability shall be checked. Found name stencils faded on all life floats. Replace. OLD-T cite: 46CFR 176.25-20
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 June 2020
Resolved
Each battery without an expiration date indicated on it or for which operator does not have record of inspection must be replced during an annual inspection; Waterlights were expired; Replace expired waterlights prior to departure; To the satisfaction of OCMI.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 June 2020
Resolved
A vessel that is aground must display appropriate dayshape configuration; Vessel was missing 01 ball dayshape; Acquire 01 ball dayshape NLT 26JUN20; To the satisfaction of the OCMI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 June 2020
Resolved
Inspection and operation of all watertight closures in the hull an decks must be of satisfactory condition; Gasket on watertight door between passenger area and main deck was wasted; Replace gasket prior to departure; To the satisfaction of the OCMI.
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 13 June 2019
Resolved
VHF radio failed to operate on emergency power. Required as per 46 CFR 184.502 and 47 CFR 80.905(a)(3). Owner shall make repairs and provide evidence of VHF operation on emergency power.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2019
Resolved
Main Diesel Engine #4 produce unsatisfactory amounts of exhaust during operation due to suspected deficient fuel injector. Owner shall provide evidence of satisfactory repairs and operation. Old T citation not listed in MISLE data base - 46 CFR 182.05-5(b), selected general New T reference
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 June 2019
Resolved
Quick acting watertight doors between engine compartment, generator compartment, and rudder compartment were not watertight. Owner shall tighten the dogs on the doors to create a watertight seal IAW 46 CFR 177.13-1.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 June 2019
Resolved
Rudder bushings on port and starboard rudder posts were wasted due to lack of maintenance and use. Owner shall replace the wasted bearings for both rudder posts.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 June 2019
Resolved
1-2" of standing oil in bilges underneath and around Main Diesel Engine #3. Owner shall remove fire hazard in bilge by cleaning/removing oil from bilges. Old T cite - 46 CFR 176.25-50(b)
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 13 June 2019
Resolved
Secondary Radar installed on bridge was inoperable. Vessel is not required to have radar installed but due to its installation, Owner shall either make satisfactory repairs or remove equipment. Good marine practice basis - 46 CFR 176.25-1(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 June 2019
Resolved
Two (02) safety relief valves on port side air compressors were missing service tags/proof of servicing. Owner shall provide evidence of testing or replace relief valves IAW 46 CFR 61.10-5(i)(2)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2019
Resolved
Starboard lube oil standpipe was missing ground connection to tank. Owner shall install proper ground for standpipe. Rectify deficiency within 30 days. Due date is 14 July 2019.
Old T cite - 46 CFR 183.01-5(a).
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 August 2017
Resolved
Conduct drills (MOB, Abandon Ship, Fire) with the crew to go underway to the satisfaction of the CG inspector prior to getting underway. Prior to sail.
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 May 2008
Resolved
Vessels bilge alarm indicator in pilothouse combine spaces for visual indicators. Each space shall have seperate indicator in the pilothouse. Install indicators for each space onboard which requires a bilge alarm.
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 May 2008
Resolved
Drills were not conducted because the vessel is cold stacked and crew onboard is not crew that will get underway with vessel. Vessel master and crew shall conduct drills with MI prior to departure.
Lifesaving › Lifefloat › Paddle
Issued 16 June 2006
Resolved
Provide paddle lines for each lifefloat and provide spacers between each lifefloat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 June 2006
Resolved
Provide machinery guards for rotating machinery on the main engines #2 and #4 as required by 46 CFR177.960.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 16 June 2006
Resolved
Replace raw water hose for the #5 engine suction line hose to the heat exchanger as required by 46CFR182.720.
Electrical › Electric Supply System (service) › Cable
Issued 16 June 2006
Resolved
Remove wire nuts from start air solenoid on #3 engine and make proper connection as required by 46CFR183.340.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 16 June 2006
Resolved
Provide cover for electrical receptacle in generator space, aft bulkhead as required by 46CFR176.800.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 June 2006
Resolved
Provide latch for engine room electrical panel as required by 46CFR176.800.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 June 2006
Resolved
Provide guards for lighting globes as required by 46CFR183.410.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 June 2006
Resolved
Clean engine room and generator room bilges as required by 46CFR176.830.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 16 June 2006
Resolved
Provide emergency broadcast placard as required by 46CFR184.506.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 13 May 2003
Resolved
Provide exhaust blankets on main engines.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 May 2003
Resolved
Provide one emergency light installed and directed to forward engine room door.
Stability › Watertight Integrity
Issued 13 May 2003
Resolved
Adjust aft engine room and rudder room watertight doors. LEGACY COMPONENT DESC: Watertight Doors
Lifesaving › Buoyant Apparatus
Issued 13 May 2003
Resolved
Secure lifefloat oars and tag lines. LEGACY COMPONENT DESC: Lifefloats
Engineering › Fuel Oil Service System › Filter
Issued 13 May 2003
Resolved
Provide metal plugs for fuel filters.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 May 2003
Resolved
Provide updated light list.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 May 2003
Resolved
Renew expired items from first aid kit.
Fire Fighting › Means of Escape
Issued 23 May 2002
Resolved
Emergency light located starboard side to be moved other side of support beam. LEGACY COMPONENT DESC: Emergency Lighting
Engineering › Compressed Air System (start air)
Issued 23 May 2002
Resolved
Ensure all connections for air lines to engines are properly clamped. LEGACY COMPONENT DESC: Piping
Fire Fighting › Means of Escape
Issued 23 May 2002
Resolved
Ensure hatch to generator room is marked with Emergency Exit Keep Clear. LEGACY COMPONENT DESC: Escape Route Signs
Engineering › Diesel Engine (propulsion-direct drive)
Issued 23 May 2002
Resolved
Repair oil leak to port engine. LEGACY COMPONENT DESC: Cylinder Liner
Fire Fighting › Means of Escape
Issued 23 May 2002
Resolved
Place Emergency Lighting in Generator Room to luminate egress to emergency escape. LEGACY COMPONENT DESC: Emergency Lighting
Casualty record · 1
20 November 2013Routine · role: Involved in a Marine Casualty · activity 4759484
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
DYLAN JOHN (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.